• Title/Summary/Keyword: Air pollutants concentration

Search Result 613, Processing Time 0.029 seconds

A Study on the Improvement of Indoor Air Quality in Apartment Buildings (공동주택의 실내공기환경 개선에 관한 연구)

  • Lee, S.H.;Park, J.C.;Rhee, E.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.397-412
    • /
    • 1996
  • This study aims to present the fundamental strategies to improve the Indoor Air Quality (IAQ) in apartment buildings. To investigate the concentration of indoor air pollutants such as radon, formaldehyde, and VOCs, both the document survey and the field measurement were conducted. In addition, to identify the source of the air pollutants, the laboratory experiment was carried out for various building materials. Finally, the minimum period to be reserved befor3e building occupation to ensure healthy IAQ, which largely depends on the ventilation rates, was simulated using a simple compuer program. The results of this study can be summarized as follows: 1. In case of newly-constructed apartment houses, concentrations of formaldehyde, VOCs and radon were found to exceed the standard. Meanwhile, at existing apartment houses, concentrations of VOCs, particularly toluene and xylene, highly exceeded the standasrd level. Concentrations of formaldehyde and radon, however, had been lowered according to the duration of occupation. 2. The laboratory experiment of concentration of pollutants per square meter of building material surface area showed that radon gas was much emitted from the gypsumboard; formaldehyde from flooring and wallpaper; and VOCs from paints and kitchen furnishings. The emission rates of formaldehyde and VOCs were proportional to air temperature. 3. According to the simulation of the minimum period to be reserved before occupation, newly-constructed airtight houses required about 190-200 days, and naturally ventialted houses with fully-open-windows required about 20-45days, in order to keep the level of radon gas lower than standard. Therefore, with the current practice, the date of occupation should be delayed for about 15 days.

  • PDF

Meteorological Field Generation Method for CALPUFF Model

  • Park, Ji-Hoon;Park, Geun-Yeong
    • Journal of Integrative Natural Science
    • /
    • v.11 no.1
    • /
    • pp.30-38
    • /
    • 2018
  • CALPUFF is one of the recommended air pollution models by EPA with AERMOD. It has been used to simulate the ambient concentration of critical air pollutants as well as non-critical pollutants such as persistent organic matters and the organic materials causing odor. In this model, the air pollutants go through dispersion, transportation, chemical reaction, and deposition process. These mechanisms are significantly influenced by meteorological condition. This study produces the meteorological field in three different methods for the simulation of $SO_2$ using CALPUFF: 1) CALMET model by using both ground-level and aerological observation, 2) CALMET model by using MM5 results with NCEP/NCAR reanalyzed data, 3) CALMET model by using MM5 results in which FDDA is applied with NCEP/NCAR reanalyzed data as well as the meteorological data of Korea Meteorological Administration. As a result of CALPUFF model, the resolved concentration of $SO_2$ showed different behaviors in three cases. For the first case, the fluctuation of SO2 concentration was frequently observed while the fluctuation is reduced in the second and third cases. In addition, the maximum concentration of $SO_2$ in the first case was about 2~3 times higher than the second case, and about 4~6 times higher than the third case. These results can be caused by the accuracy of the resolved meteorological field. It is inferred that the meteorological field of the first case could be less accurate than other two cases. These results show that the use of correct meteorological data can improve the result of dispersion model. Moreover, the contribution of various sources such as point, line, and area sources on the ambient concentration of air pollutant can be roughly estimated from the sensitivity analysis.

Study on the Characteristics of Concentrations and Compositions in $PM_{10}$ in Kunsan City (군산 지역에서 $PM_{10}$의 농도 및 성분 특성에 관한 연구)

  • 김성천;송재종;임성호;강달선
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.18-24
    • /
    • 2000
  • The collection of PM10 samples were collected by a PM10 hi-vol. air sampler from June, 1998 through May, 1999 in Kunsan located at western coastal region of Korea. We obtained 84 samples during sampling period. Samples were analyzed to quantify the concentration of ionic and metallic components such as SO42-, NO3-, Cl-, NH4+, K+, Na+, Mg2+, Zn, Cd, Cr, Pb and Fe. Seasonal variations of the concentrations by wind directions of each component were studied. We found that PM10 concentration had the highest level in winter and the lowest level in summer. When the wind direction is from west to east, the concentration of most ionic and metallic species were higher compared to reverse direction. That implied the effect of air pollutants from industrial area. Also, substantial amount of Na+ and Cl- were observed, which was assumed to the effect from the sea.

  • PDF

Numerical Simulation of $NO_2$Concentration considering SST Effects (SST 효과를 고려한 계절별 $NO_2$농도 수치모의)

  • 원경미;이화운;김유근
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.187-194
    • /
    • 2001
  • For the purpose of predicting air pollutants concentration in Pusan coastal urban, we used an Eulerian model of flow and dispersion/chemistry/deposition process considering SST effects which estimate through POM. The results of air quality model including emission from various sources show that the seasonal variation pattern of respective pollutants was affected by the seasonal SST fields and local circulation. Horizontal deviation of diurnal SST was 2.5~4K, especially large gradients in coastal region. Through numerical simulation of wind fields we predicted that local circulation prevailed during daytime in summer and nighttime in winter. So high concentration distribution showed toward inland in spring and summer seasons, while high concentration distribution showed at inland near coast in autumn and winter.

  • PDF

Analysis on the Effects of Particular Matter Distribution on the Number of Outpatient Visits for Allergic Rhinitis (지역별 미세먼지 농도의 알레르기비염 외래이용에 대한 영향 분석)

  • Park, Ju Hyun;Park, Young Yong;Lee, Eunjoo;Lee, Kwang-Soo
    • Health Policy and Management
    • /
    • v.30 no.1
    • /
    • pp.50-61
    • /
    • 2020
  • Background: This study aims to analyze the effects of air pollutants, such as particular matter, to the number of outpatient visits for allergic rhinitis in eup, myeon, and dong administrative boundaries. Methods: Dependent variable was the number of outpatient visits for allergic rhinitis per 10,000 people by region. Independent variables were air pollutants such as PM10, PM2.5, SO2, O3, CO2, NO2, and temperature that estimated by using Kriging analysis in all eup, myeon, and dong boundaries. Panel analysis was applied for the analysis to prove the relation between outpatient visits and the concentration of air pollutants. Results: Analysis results showed that particular matter concentration varied by regions and season. Panel analysis showed that outpatient visits for allergic rhinitis had positive relationships with PM10, PM2.5, SO2, O3, and CO2 in all panel models. Conclusion: Regional variation of particular matter concentration should be considered in establishing regional policies for allergic rhinitis.

3-D Numerical Prediction Modeling of Air Pollution in Coastal Urban Region - II. Movement and Diffusion Prediction of Air Pollutants - (연안도시지역에서 대기오염의 3차원 수치예측모델링 -II. 대기오염물질의 이동과 화산예측-)

  • gyeong-Mee Won;Hwa-Woon Lee
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.343-350
    • /
    • 2001
  • To investigate air quality away from the coastal urban source region, we used a hybrid Eulerian - Lagrangian method which can describe the formation, transport, transform and deposition processes in complex terrain, with inclusion of shipping sources that were considered to be important emission in the coastal urban region. The result of the Eulerian advection - diffusion prediction was quite similar to that of the Lagrangian particle diffusion prediction. It showed that pollutants emitted from Sasang and Janglim industrial complexes can affect Hwamyeong and the coastal, respectively. During the daytime the concentration was low due to large deposition flux and terrain effect.

  • PDF

A Study of Air Pollutants Dry Deposition (대기오염물질의 건성침적에 관한 연구)

  • Lee, Chi-Young;Kang, Dong-Ku
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.64-68
    • /
    • 2003
  • Measurement of dried deposition for air pollutant was investigated in Gwang-ju Health college area for a year. The average value of air pollutants was investigated three times a month. Measured heavy metals and concentration of mass are not corelated. Heavy metals were thrown up air as state of large particles and they were moved by wind. Deposition of heavy metals and deposition velocities were high in the order of Fe > n > Cu > Pb > Cr and Pb > Fe > Cr > Zn > Cu, respectively. The pattems of deposition velocity of heavy metals for a year were much the same as each other except that Pb is faster than others.

Relationship between Thermal Low and Long-Range Transport of Air Pollutants (대기오염물질의 장거리 수송과 열적저기압의 관계)

  • 이화운;김유근;김해동;정우식;현명숙
    • Journal of Environmental Science International
    • /
    • v.10 no.2
    • /
    • pp.143-151
    • /
    • 2001
  • The atmospheric conditions and the transport mechanism of long-range transport of air pollutants from coastal area to inland area were investigated using regular meteorological data and air pollution data obtatined from the southeastern area of Korea. Daytime temperature over the inland area(Taegu) was higher than that over the coastal area(Pusan) and the temperature difference of about 5~6$^{\circ}C$ when the thermal low most fully developed and the sea level pressure over Taegu was lower than that over Pusan by about 4~5hPa at that time. Therefore this low pressure appeared to the thermally induced low. Air mass polluted from the coastal area during the morning period was transported inland area, at first by the sea breeze and by the large scale wind system toward the thermal low generated in the mountainous inland region. This was explained by the fact that the concentration of air pollutants over Taegu increased throughtout the late afternoon.

  • PDF

A Field Survey on the Characteristics of Air Pollutants Emission from Commercial Charcoal Kiln (숯가마에서 발생하는 대기오염물질의 배출특성에 관한 현장조사 연구)

  • Park, Seong-Kyu;Choi, Sang-Jin;Kim, Jin-Yun;Park, Gun-Jin;Hwang, Ui-Hyun;Lee, Jeong-Joo;Kim, Tae-Sik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.601-614
    • /
    • 2013
  • The commercial charcoal kiln was projected the largest source of biomass burning sector in Korea. Commercial charcoal kiln was operated to emit air pollutants into the air without any air pollution prevention equipment. The object of this field survey was to understand characteristics of air pollutants concentration and emission factors and to provide preliminary data for effective processor from oak charcoal manufacturing process. As result of field survey, TSP, $PM_{10}$ and $PM_{2.5}$ concentration from charcoal kiln were 400~37,000 $mg/m^3$. These values were over the 100 $mg/m^3$ in TSP, this value was effluent quality standard of Clean Air Conservation Act. The average concentration of CO, $SO_2$ and TVOC were 2~5%. 0~110 ppm and 820~10,000 ppm respectively. The emission factors were 42.4 g-PM/kg-oak in TSP, 40.3 g-PM/kg-oak in $PM_{10}$, 38.2 g-PM/kg-oak in $PM_{2.5}$, 182.5 g-CO/kg-oak, 1.0 g-NO/kg-oak, $SO_2$ 0.2 g-$SO_2/kg$-oak and 104.4 g-TVOC/kg-oak. The part of commercial charcoal kiln had air pollution prevention equipment but it was difficult to work properly. Much wood tar excreted in exhaust emissions from oak charcoal manufacturing process. This wood tar was cause of many troubles sticking in the air pollutant prevention equipment. For handling particulate matters and gaseous air pollutants from oak charcoal manufacturing process in biomass burning, air pollutant prevention equipment design and management needs preprocessor for removal wood tar.

Survey on Air Pollution in Underground Commercial Floor of Pusan Areas (부산지역 지하상가의 대기오염도에 관한 조사 연구)

  • 이채언;문덕환;조병만;김준연;배기철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.22-32
    • /
    • 1989
  • In order to assess the level of atmospheric pollution and to contribute the health improve ment of residents in Pusan, the authors measured the $CO, SO_2, NO_2, TSP, Noise, Pb, Cd, Cr and V$ level at 3 place by time from Jan. 1988 to Feb. 1988. THe places were Kukje, Daehyeon, Pujeon underground commercial floor. The results were as follows; 1. The range of concentration of air pollutants (1) CO : 0.5 - 3.0 ppm (2) $SO_2$ : 0.012 - 0.360 ppm (3) $NO_2$ : 0.018 - 0.089 ppm (4) TSP : 30 - 330 $\mug/m^3$ (5) Pb : 0.219 - 3.116 $\mug/m^3$ (6) Cd : 0.000 - 0.070 $\mug/m^3$ (7) Cr : 0.378 - 4.098 $\mug/m^3$ (8) V : 0.000 - 1.010 $\mug/m^3$ (9) Noise : 47 - 77 dB(A) 2. The level of all air pollutants were higher in the afternoon or night than in the morning. 3. The mean concentration of $SO_2$ in all places exceede the ambient air quality standard of $SO_2$,.

  • PDF