• 제목/요약/키워드: Air pollutants concentration

검색결과 615건 처리시간 0.027초

1997~2005년 제주시 지역 강수의 산성화 및 중화 특성 연구 (Study on Acidification and Neutralization Characteristics of Precipitation in JejuCity between 1997 and 2005)

  • 강창희;홍상범;김원형;고희정;이순봉;송정민
    • 한국대기환경학회지
    • /
    • 제22권4호
    • /
    • pp.487-498
    • /
    • 2006
  • Total 438 precipitation samples were collected in Jeju City between 1997 and 2005, and their major ionic components were analyzed. The comparison tests using ion balance, electric conductivity and acid fraction were performed. It was found their correlation coefficients were in the range of 0.977$\sim$0.994, indicating the good quality of collected dam. The volume-weighted mean pH and electric conductivity were 4.8 and 23.0 $\mu$S/cm, respectively. with the ionic strength of 0.23$\pm$0.20 mM. The marine ($Na^+$, $Mg^{2+}$, and $CI^-$), anthropogenic (nss$SO_4{2-}$, $NO_3^-$, and $NH_4^+$) and soil (nss-$Ca^{2+}$) species have contributed to the ionic components of precipitation samples with 43$\sim$74%, 16$\sim$37% and $\sim$5%, respectively. The seasonal variations of $NO_3^-$ and nss-$SO_4^{2-}$ showed a distinct seasonality with higher concentrations in winter than summer, indicating an increase of fossil fuel consumption and a possibility of long-range transport of those pollutants from continental area along the dominant winter westerly. The levels of nss-$Ca^{2+}$ also were appeared the highest in winter and increased comparatively in spring season. possibly due to the soil influences including the Asian Dust. The acidification contribution of nss-$SO_4^{2-}$ and $NO_3^-$ showed 88$\sim$96%, and the free acidity was in the range of 6.0$\sim$40.1%. Interestingly, the backward trajectories for the case of upper 10% nss-$SO_4^{2-}$ and $NO_3^-$ levels have passed through the China continent before their arrival to Jeju. The precipitation of pH below 4.5 has been occurred frequently when the trajectory's path lied over the China continents. On the other hand, the air masses from the North Pacific area were characterized by lower 10% of nss-$SO_4^{2-}$- and $NO_3^-$ concentration, which demonstrated that air mass from the North Pacific was the cleanest among air masses moved to Jeju.

Monte-Carlo 모의실험을 이용한 초·중·고등학교의 환기부족 평가 (Evaluation of Ventilation Deficiecy in Elementary, Middle, and High Schools using Monte Carlo Simulation)

  • 최영태;박진현;김은채;류현수;김동준;민기홍;정다영;우병렬;조만수;양원호
    • 한국환경보건학회지
    • /
    • 제46권6호
    • /
    • pp.627-635
    • /
    • 2020
  • Objectives: Indoor air quality has become more important aspeople spend most of their times indoors. Since students spend most of their times at home or at school, they are more likely to be exposed to indoor air pollutants. Ventilation in school classrooms can affect health and learning performance. In this study, ventilation deficiency was evaluated in school classrooms using Monte Carlo simulation. Methods: This study used sensor-based monitoring for six months to measure carbon dioxide (CO2) concentrations in classrooms in elementary, middle, and high schools. The volume of the classroom and the number of students were investigated, and the students' body surface area was used to calculate the CO2 emission rate. The distribution of ventilation rates was estimated by measured CO2 concentration and a mass-balance model using Monte Carlo simulation. Results: In the elementary, middle, and high schools, the average CO2 concentrations exceeded 1000 ppm, indicating that the ventilation rates were insufficient. The ventilation rates were deficient from July to August and in December, but showed relatively high ventilation rates in October. Forty-three percent of elementary schools, 56% of middle schools, and 62% of high schools showed insufficient ventilation rates. Conclusions: The ventilation rates calculated in elementary, middle and high schools were found to be quite insufficient. Therefore, proper management is needed to overcome the lack of ventilation and improve air quality.

TDLAS를 이용한 LPG/공기 화염 연소가스의 실시간 CO 농도 측정에 관한 연구 (An Experimental Study on Real Time CO Concentration Measurement of Combustion Gas in LPG/Air Flame Using TDLAS)

  • 소성현;박대근;박지연;송아란;정낙원;유미연;황정호;이창엽
    • 청정기술
    • /
    • 제25권4호
    • /
    • pp.316-323
    • /
    • 2019
  • 대기 오염 물질 저감과 연소 효율 증가를 위해서 연소 환경 내 일산화탄소를 정밀하게 측정하는 것은 필수적인 요소이다. 일산화탄소(carbon monoxide, CO)는 불완전 연소 때 급격히 증가하며 질소산화물(nitrogen oxide, NOx)과 Trade-off 관계로 오염 물질 배출량과 불완전 연소 반응에 기여하는 중요한 가스종이다. 특히, 대형 연소 시스템 중 열처리로의 경우, 강판 표면위 산화층 형성을 억제하기 위해 과잉 연료 조건에서 환원 분위기로 운전이 진행된다. 이는 많은 양의 미연분 일산화탄소가 배출되는 원인이기도 하다. 하지만 연소 환경 내에서 일산화탄소 농도는 불균일한 연소 반응과 열악한 측정 환경으로 인하여 실시간 측정이 어렵다. 이러한 문제점을 극복하기 위해서 광학적 측정 방식인 파장 가변형 다이오드 레이저 흡수 분광법(tunable diode laser absorption spectroscopy, TDLAS)이 각광을 받고 있다. TDLAS 기법은 열악한 현장 측정, 빠른 응답성, 비접촉식 방식으로 연소 환경 내 특정 가스종 농도 측정에 적합하다. 본 연구는 과잉 연료 조건에서 당량비 제어를 위한 연소시스템을 제작하였으며 연소 배기가스 생성을 위해 LPG/공기 화염을 이용하였다. 당량비 변화에 따른 CO 농도 측정은 TDLAS와 Voigt 함수 기반 시뮬레이션으로 분석하였다. 또한 연소 생성물로부터 간섭이 없는 CO 광 흡수 영역 확보를 위해 근적외선 영역의 4300.6 cm-1을 선택하여 실험을 진행하였다.

Chemical Characteristics of Precipitation in Quercus Forests in Korea and Japan

  • Kim, Min Sik;Takenaka, Chisato;Park, Ho Taek;Chun, Kun Woo
    • 한국산림과학회지
    • /
    • 제96권5호
    • /
    • pp.503-509
    • /
    • 2007
  • The major objective of this study was to analyze the difference of the chemical characteristics of acid deposition in Quercus forests in Korea and Japan. The pH values of rainfall at the experimental forest of Kangwon National University (KS site) were higher than those at the Foresta Hills in Japan (JP site), and all chemical contents of throughfall and stemflow were much higher than those of rainfall in Quercus forest stands at the KS and JP site. The pH values, $Ca^{2+}$, $NO_3{^-}$ and $SO{_4}^{2-}$ concentration of throughfall and stemflow at the KS site showed seasonal variation. While at the JP site, the same pattern was shown in the pH values of throughfall and stemflow, however, did not show any difference among seasons. Also, the annual input of all nutrients in these two contrasting forests varied seasonally. These results can be used to predict the amounts of air pollutant that are washed off and leached by the rainfall and Yellow Sand (Asian dust), including NOx and SOx acid pollutants transported easterly from China in the spring. Therefore, it is necessary to quantify the inputs of dry and wet deposition throughout a full year to gain a more complete understanding of the effects of acid deposition on the nutrient cycles in these forest ecosystems.

Characterization of Particulate Emissions from Biodiesel using High Resolution Time of Flight Aerosol Mass Spectrometer

  • Choi, Yongjoo;Choi, Jinsoo;Park, Taehyun;Kang, Seokwon;Lee, Taehyoung
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권1호
    • /
    • pp.78-85
    • /
    • 2015
  • In the past several decades, biofuels have emerged as candidates to help mitigate the issues of global warming, fossil fuel depletion and, in some cases, atmospheric pollution. To date, the only biofuels that have achieved any significant penetration in the global transportation sector are ethanol and biodiesel. The global consumption of biodiesel was rapidly increased from 2005. The goal of this study was to examine the chemical composition on particulate pollutant emissions from a diesel engine operating on several different biodiesels. Tests were performed on non-road diesel engine. Experiments were performed on 5 different fuel blends at 2 different engine loading conditions (50% and 75%). 5 different fuel blends were ultra-low sulfur diesel (ULSD, 100%), soy biodiesel (Blend 20% and Blend 100%) and canola biodiesel (Blend 20% and Blend 100%). The chemical properties of particulate pollutants were characterized using an Aerodyne High Resolution Time of Flight Aerosol Mass Spectrometer (HR-ToF-AMS). Organic matter and nitrate were generally the most abundant aerosol components and exhibited maximum concentration of $1207{\mu}g/m^3$ and $30{\mu}g/m^3$, respectively. On average, the oxidized fragment families ($C_xH_yO_1{^+}$, and $C_xH_yO_z{^+}$) account for ~13% of the three family sum, while ~87% comes from the $C_xH_y{^+}$ family. The two peaks of $C_2H_3O_2$ (m/z 59.01) and $C_3H_7O$ (m/z 59.04) located at approximately m/z 59 could be used to identify atmospheric particulate matter directly to biodiesel exhaust, as distinguished from that created by petroleum diesel in the AMS data.

조합환기 방식 터널의 환기기 운전 단계에 관한 연구 (The study of operation mode of ventilation system in the longitudinal ventilation system tunnel)

  • 유지오;신현준;이동호;이용화
    • 한국터널지하공간학회 논문집
    • /
    • 제4권4호
    • /
    • pp.343-353
    • /
    • 2002
  • 최근들어 장대터널이 증가하여 환기시스템의 환기기 용량이 증대하게 되면서 환기방식이 다양화 되어 환기기 운전동력등 터널준공 후 유지관리의 중요성이 부각되게 되었다. 따라서 환기기 운전단계나 환기기 운전모드에 대한 연구의 필요성이 증대하여 본 연구에서는 기 개발된 일교통량의 변화 및 환기기 가동상태에 따라 비정상상태로 터널 환기를 해석할 수 있는 동적 시뮬레이션 프로그램에 의해서 집진기 방식과 수직갱방식에 대한 운전동력을 평가하여 최적운전 모드를 제안하였다.

  • PDF

이어도 해양과학기지 PM2.5의 이온과 탄소 조성 특성 (Ionic Compositions and Carbonaceous Matter of PM2.5 at Ieodo Ocean Research Station)

  • 한지현;김자한;강은하;이미혜;심재설
    • 한국대기환경학회지
    • /
    • 제29권6호
    • /
    • pp.701-712
    • /
    • 2013
  • The purpose of this study is to determine concentrations and compositions of $PM_{2.5}$ and their characteristic variations at Ieodo Ocean Research Station in the East China Sea and to examine the influence of air pollutants transported from Asia continents. $O_3$ and meteorological parameters were measured since June 2003 and $PM_{2.5}$ filter samples were collected from June 2004 to June 2008. In total, 244 samples were analyzed for water soluble ions and carbonaceous compounds. The mean mass concentration of $PM_{2.5}$ and $O_3$ were $21.8{\pm}14.9{\mu}g/m^3$ and $51.6{\pm}16.1$ ppb, respectively. The average concentrations (mass fractions) of sulfate and ammonium were $6.26{\mu}g/m^3$ (28.74%) and $1.59{\mu}g/m^3$ (7.31%), respectively. Nitrate was considered to be lost through evaporation due to long stay at the station. The mean concentrations of EC and OC were $1.01{\mu}g/m^3$ and $2.34{\mu}g/m^3$, respectively, from June 2006 to June 2008. The average OC/EC ratio was 2.31. The organic matter converted from OC by multiplying 2.1 and elemental carbon constituted 22.60% and 4.66% of $PM_{2.5}$ mass, respectively.

부산시 남부하수처리시설과 인근 하천에서 발생하는 악취물질 확산 특성 (Dispersion Characteristics of Odorous Elements from Nambu Wastewater Treatment Plant and a Nearby Streams in Busan)

  • 문성만;이형돈;조상원;강동효;박해식;오광중
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.953-962
    • /
    • 2011
  • The covered stream of cities are considered an odor source. Also, the public do not want a wastewater treatment plant(WWTP) near their properties due to the emission of odor emanating from such sources, although they play an important role in urban development. The purpose of this study is to analyze the pattern distribution of the odorous compounds from the Nambu WWTP and Youngho stream in Busan. odor sampled four times were analyzed by instrumental analysis method and indirect olfactory method. The kinds of offensive odorous compounds examined are acetaldehyde, propion aldehyde, hydrogen sulfide, methyl mercaptan, dimethyl sulfide and ammonia. Also, Concentration of air pollutants has been calculated by ISCST3 models. At the result of this study, The Nambu WWTP releases sulfur compounds. And the major odorous were hydrogen sulfide (1,475 ppb) and acetaldehyde (95 ppb) at Youngho stream. The stink which residents feel will point out the Nambu WWTP mainly if the odor is removed with the improvement of a Youngho stream. Accordingly, we should pay more attention to appropriate components to processes in odor reducing plan at Nambu WWTP.

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.85-88
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PARs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRT AP) of Europe. A method of the gas chromatographic-mass spectrometric (GC-MS) determination of PARs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PARs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PARs sewage sludge samples varied from 2.44 to 4.82 ${\mu}g$/g. Concentration of emission carcinogen PARs(PARcarc), such as Benzo(a)anthracene, Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(a)pyrene, Dibenzo(a, h)anthracene and Indeno(1, 2, 3-cd)pyrene ranged from 0.62 to 1.03 ${\mu}g$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PARs and $\sum$PAHcarc from sewage treatment plants had several pathway each by-products. In the ocean dumping, PAHs and $\sum$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year. In recycle, PAHs and $\sum$PAHcarc emissions were 98.36 kg/year and 428.87 kg/year. In the landfill, PAHs and $\sum$PAHcarc emissions were 190.40 kg/year and 830.21 kg/year. In the incineration, PAHs and $\sum$PAHcarc emission were 33.10 kg/year and 830.21 kg/year. (In case of incineration, the whole provisions of PARs and $\sum$PAHcarc contained to flowed in sludge was supposed to be exhausted to environment through exhaust after incineration.)

  • PDF

PEMS를 이용한 소형 경유차의 실주행 NOx 배출특성 평가 (Estimation of Real-Driving NOx Emission Characteristics from Light-Duty Diesel Vehicles with PEMS)

  • 박연재;권상일;박준홍;이재영
    • 한국대기환경학회지
    • /
    • 제31권6호
    • /
    • pp.562-572
    • /
    • 2015
  • $NO_x$ emissions from diesel vehicles have been regarded as a main cause of high $NO_2$ concentration in metropolitan area. Recent studies have shown that the on-road $NO_x$ emissions of diesel vehicles are quite higher than the emission limits specified with the pre-defined test method for emission certification. To reduce air pollutants effectively, the discrepancy of emissions in certification and real-driving conditions should be tackled. In this study, the real-driving emissions have been estimated with portable emission measurement system (PEMS). The results of this study have shown that the on-road $NO_x$ emissions from diesel vehicles have been decreased as the introduction of stricter emission regulation, EURO-6, but additional reduction should be still required and robust technologies should be applied to control $NO_x$ in real-driving conditions. RDE-LDV (Real Driving Emission - Light Duty Vehicles) test method being developed in the European Union can represent excessive on-road $NO_x$ emissions of diesel vehicles as applied emission technologies and can be a solution to remove discrepant $NO_x$ emissions between certification and Korean real-driving conditions. Among the $NO_x$ reduction technologies for EURO-6 diesel vehicles, selective catalytic reduction (SCR) system has shown the better performance than lean $NO_x$ trap (LNT) system to control on-road $NO_x$ emissions. Implementing RDE-LDV will require vehicle manufacturers to adopt the more effective $NO_x$ reduction technology in real driving conditions.