• 제목/요약/키워드: Air pollutants concentration

검색결과 613건 처리시간 0.025초

국내 배경지역 대기 미세먼지의 기류 이동경로별 조성변화: 2013년 측정 (Composition Variation of Atmospheric Fine Particulate Matters in Accordance with Air Mass Transport Pathways at Background Site of Korea in 2013)

  • 고희정;임은하;송정민;김원형;강창희;이해영;이철규
    • 한국대기환경학회지
    • /
    • 제31권1호
    • /
    • pp.15-27
    • /
    • 2015
  • The collection of fine particulate matter samples was made at Gosan site of Jeju Island, one of the background sites of Korea, during a year of 2013, and their water-soluble ionic species were analyzed in order to examine the chemical compositions and pollution characteristics. The concentrations of $nss-SO_4{^{2-}}$, $NH_4{^{+}}$, $NO_3{^{-}}$, and $K^+$ had occupied 66.0% of water-soluble ionic species in $PM_{10}$, especially 94.3% in $PM_{2.5}$ fine mode, however the $nss-Ca^{2+}$ and $Na^+$ showed high concentrations in $PM_{10-2.5}$ coarse mode. $NO_3{^-}/nss-SO_4{^{2-}}$ concentration ratios in $PM_{10}$ and $PM_{10-2.5}$ were 0.30 and 0.13, showing less significant effect from automobile and local pollution sources. The sulfate and nitrate compounds were presumed to be long-range transported to Gosan area by the relatively high SOR and NOR values. The trajectory cluster analysis showed the higher concentrations of the major secondary pollutants ($nss-SO_4{^{2-}}$, $NO_3{^{-}}$, $NH_4{^{+}}$) and $nss-Ca^{2+}$ when the air masses had moved from China continent and Korean peninsula into Gosan area.

방전 플라스마에 의한 CFC-12($CCl_2F_2$)의 분해 (Decomposition of CFC-12($CCl_2F_2$) by Discharge Plasma)

  • 강현춘;우인성;황명환;안형환;이한섭;조정국;강안수
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.93-100
    • /
    • 1999
  • Decomposition efficiency, power consumption, and applied voltage of CFC(Chlorofluorocatbon) were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of CFC-12 with various electric frequencies(5~50kHz). flow rates (100~1,000mL/min), initial concentrations(100~1,000ppm), electrode materials(W, Cu, Al). electrode thickness(1, 2, 3mm) and reference gases($N_2$, $O_2$, air) were measured and the products were analyzed with FT-IR. Experimental results showed that at the frequency of 10kHz, the highest decomposition efficiency of 92.7% for CFC-12 were observed at the power consumptions of 29.6W. respectively, and that decomposition efficiency decreased with increasing frequency above 20kHz and decomposition efficiency per unit power were 3.13%/W for CFC-12. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3m. As the electrode material, decomposition efficiency was in order that tungsten(W), copper(Cu), aluminum (Al). Decomposition of CFC-12 in the reference gas of $N_2$ showed the highest efficiency among three reference gases, and then the effect of reference gas on the decomposition efficiency decreased in order of air and $O_2$. The optimum power for the maximum decomposition efficiency was 25.3W for CFC.

  • PDF

Spatial analysis of $PM_{10}$ and cardiovascular mortality in the Seoul metropolitan area

  • Lim, Yu-Ra;Bae, Hyun-Joo;Lim, Youn-Hee;Yu, Seungdo;Kim, Geun-Bae;Cho, Yong-Sung
    • Environmental Analysis Health and Toxicology
    • /
    • 제29권
    • /
    • pp.5.1-5.7
    • /
    • 2014
  • Objectives Numerous studies have revealed the adverse health effects of acute and chronic exposure to particulate matter less than $10{\mu}m$ in aerodynamic diameter ($PM_{10}$). The aim of the present study was to examine the spatial distribution of $PM_{10}$ concentrations and cardiovascular mortality and to investigate the spatial correlation between $PM_{10}$ and cardiovascular mortality using spatial scan statistic (SaTScan) and a regression model. Methods From 2008 to 2010, the spatial distribution of $PM_{10}$ in the Seoul metropolitan area was examined via kriging. In addition, a group of cardiovascular mortality cases was analyzed using SaTScan-based cluster exploration. Geographically weighted regression (GWR) was applied to investigate the correlation between $PM_{10}$ concentrations and cardiovascular mortality. Results An examination of the regional distribution of the cardiovascular mortality was higher in provincial districts (gu) belonging to Incheon and the northern part of Gyeonggi-do than in other regions. In a comparison of $PM_{10}$ concentrations and mortality cluster (MC) regions, all those belonging to MC 1 and MC 2 were found to belong to particulate matter (PM) 1 and PM 2 with high concentrations of air pollutants. In addition, the GWR showed that $PM_{10}$ has a statistically significant relation to cardiovascular mortality. Conclusions To investigate the relation between air pollution and health impact, spatial analyses can be utilized based on kriging, cluster exploration, and GWR for a more systematic and quantitative analysis. It has been proven that cardiovascular mortality is spatially related to the concentration of $PM_{10}$.

Photocatalysis of Low Concentration of Gaseous-Phase Benzene Using Visible-Light Irradiated N-doped and S-doped Titanium Dioxide

  • Jo, Wan-Kuen;Kim, Jong-Tae
    • Environmental Engineering Research
    • /
    • 제13권4호
    • /
    • pp.171-176
    • /
    • 2008
  • Studies on visible-light-driven photocatalysis of air pollutants at indoor air quality (IAQ) levels have been limited. Current study investigated visible-light derived photocatalysis with N-doped and S-doped titanium dioxide ($TiO_2$) for the control of benzene at indoor levels. Two preparation processes were employed for each of the two types of photocatalyst: urea-Degussa P-25 $TiO_2$ and titania-colloid methods for the N-doped $TiO_2$; and titanium isopropoxid- and tetraisopropoxide-thiourea methods for the S-doped $TiO_2$. Furthermore, two coating methods (EDTA- and acetylacetone-dissolving methods) were tested for both the N-doped and S-doped $TiO_2$. The two coating methods exhibited different photocatalytic degradation efficiency for the N-doped photocatalysts, whereas they did not exhibit any difference for the S-doped photocatalysts. In addition, the two doping processes showed different photocatalytic degradation efficiency for both the S-doped and N-doped photocatalysts. For both the N-doped and S-doped $TiO_2$, the photocatalytic oxidation (PCO) efficiency increased as the hydraulic diameter (HD) decreased. The degradation efficiency determined via a PCO system with visible-light induced $TiO_2$ was lower than that with UV-light induced unmodified $TiO_2$, which was obtained from previous studies. Nevertheless, it is noteworthy that for the photocatalytic annular reactor with the HD of 0.5 cm, PCO efficiency increased up to 52% for the N-doped $TiO_2$ and 60% for the S-doped $TiO_2$. Consequently, when combined with the advantage of visible light use over UV light use, it is suggested that with appropriate HD conditions, the visible-light-assisted photocatalytic systems can also become an important tool for improving IAQ.

A Study on Cost-effective Treatment of Wastewater and Odor Reduction for Southeast Asian Market Entry

  • Jung, Min-Jae;Kim, Yong-Do;Kwon, Lee-Seung;Lee, Woo-Sic;Kwon, Woo-Taeg
    • 산경연구논집
    • /
    • 제9권12호
    • /
    • pp.23-29
    • /
    • 2018
  • Purpose - The purpose of this study is to apply a cost effective ultrasonic odor reduction method that generated micro-bubbles using ejector to the Southeast Asian wastewater market. Research design, data, and methodology - A leather maker located in Ansan-city, Gyunggi-do, South Korea was sampled from the collection tank to select experimental materials. Experimental setup consisted of circulating water tank-air ejector-ultrasonic device, and circulating wastewater. Sample analysis was performed by CODcr, T-N, T-P, and turbidity by the National Environmental Science Institute. Results - Experimental results show that it is most effective in removing odors when the frequency range of ultrasonic wave is 60~80 Khz and the output is 200 W. It showed that the concentration of complex odor dropped from a maximum of 14,422 times to a minimum of 120 times. Also, analysis of ammonia and hydrogen sulfide in specific odor substances has shown that they were reduced from 1.5 ppm to 0.4 ppm and from 0.6 ppm to 0.1 ppm, respectively. Conclusions - It is possible to shorten more than 12 hours in the treatment of micro-organisms. It can be seen that the processing time of odor after ultrasonic treatment in the pre-treatment facility is reduced by 25% when compared to the resultant micro-organisms after the chemical treatment, that is, the time of the bio-treatment of micro-organisms. Based on the results, it was confirmed that the pre-treatment method using the ultrasonic and the air ejector device of the experiment shows the effect of reducing the water pollutants and odor more effectively in a relatively short time than the conventional advanced oxidation method.

Assessment of the Nitrate Radical Chemistry and Chemical Composition on Jeju Island during the Asian Pollution Period in the Spring of 2001

  • Shon, Zang-Ho;Kim, Ki-Hyun;Keith N. Bower;Lee, Gangwoong;Kim, Jiyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E3호
    • /
    • pp.137-148
    • /
    • 2003
  • In this study, we examined the influence of long-range transport of dust particles and air pollutants on the photochemistry of NO$_3$on Jeju Island, Korea (33.17 N, 126.10$^{\circ}$E) during the Asian Dust-Storm (ADS) period of April 2001. Three ADS events were observed during the periods of 10∼12, 13∼14, and 25∼26 April. Average concentration level of nighttime NO$_3$on Jeju Island during the ADS period was estimated to be about 2 x 10$^{8}$ molecules cm$^{-3}$ ( - 9 pptv). Decreases in NO$_3$levels during the ADS period was likely to be determined mainly by the enhancement of the $N_2$O$_{5}$ heterogeneous reaction on dust aerosol surfaces. The reaction of N20s on aerosol surfaces was a more important sink for nighttime N03 during the ADS due to the significant loading of dust particles. The reaction of $N_2$O$_{5}$ with NMHCs and the gas-phase reaction of N20s with water vapor were both significant loss mechanisms during the study period, especially during the NADS. However, dry deposition of these oxidized nitrogen species and a heterogeneous reaction of NO$_3$were of no importance. Short-term observations of $O_3$, NO$_2$, DMS, and SO$_2$in the MBL indicated that concentrations of most of these chemical species were different between the ADS and non - Asian - Dust-Storm (NADS) periods, implying that their levels were affected sensitively by the differences in air mass trajectories.

자동 베이크 아웃 시스템을 이용한 휘발성유기화합물 및 포름알데히드 저감효과 (Reduction Effect of VOCs and Formaldehyde Using Auto Bake-Out System)

  • 김형진;이갑수;조진규;이준범;노형래;윤홍수
    • 공업화학
    • /
    • 제22권3호
    • /
    • pp.291-295
    • /
    • 2011
  • 초등학교의 신축된 실내체육관을 대상으로 자동 개폐장치를 이용하여 실내의 휘발성유기화합물 및 포름알데히드 농도 저감효과를 평가하기 위하여 5일간 베이크 아웃을 진행하였다. 베이크 아웃을 실시한 결과 베이크 아웃 실시 전의 농도에 비해 벤젠의 경우 38.2%, 톨루엔은 64.2%, 에틸벤젠은 86.3%, 자일렌은 80.2%, 스티렌은 71.5%의 저감률을 보였으며, 환경부의 신축공동주택의 실내공기질 기준치를 만족하는 것으로 나타났다. 총휘발성유기화합물의 저감률은 67.0%이었으며 포름알데히드의 경우 24.7%의 저감률을 보여 자동 개폐장치를 이용한 베이크 아웃이 실내오염물질을 제거하는 데 유용함을 확인하였으며, 자동 베이크 아웃 시스템을 이용할 경우 효과적인 베이크 아웃이 가능함을 확인하였다.

대형 주물공정 용접작업장의 건강 위해인자 및 환기 개선 (Health Risk Factors and Ventilation Improvements in Welding Operation at Large-sized Casting Process)

  • 정종현;정유진;이상만;이정희;손병현;임현술
    • 청정기술
    • /
    • 제20권2호
    • /
    • pp.171-178
    • /
    • 2014
  • 이 연구에서는 대형 주물공정 용접작업장 근로자들의 건강보호 및 작업환경 개선을 위해 위해인자 조사 및 분석작업을 수행하였다. 또한, 대상 작업장의 작업환경을 개선하기 위해 측정 및 전산유체해석 모델링을 수행한 후 효과적인 환기방법을 제안하였다. 대형 주물공정 용접작업장 근로자들의 건강 위해인자를 조사한 결과, A사는 산화철분진, B사와 C사는 용접흄, D사는 용접 흄과 산화철분진이 주오염원인 것으로 확인되었다. 작업자 호흡영역에서의 흄 농도는 $0.05{\sim}4.37mg/m^3$이었고, 용접작업장 공기 중 흄 농도는 $0.13{\sim}7.54mg/m^3$이었다. 또한, 용접작업 시 최적의 환기방법을 제안하기 위해 측정 및 전산유체해석 모사를 수행한 결과, 배기공정의 경우에는 배기 덕트를 용접점에 근접시켜 국소배기를 실시하는 것이 효과적인 것으로 나타났다. 급기공정의 경우에는 개구부 끝 부분에서 급기를 하며 급기용 팬은 작업 공간 외부에 설치하는 것이 효과적일 것으로 나타났다. 향후 대형 주물공정 용접작업장의 터널형 반밀폐 공간에 대한 환기방법을 표준화한다면 주물산업 및 조선업 등에 종사하는 용접 근로자들의 건강보호 및 작업환경 개선에 매우 효과적일 것으로 판단된다.

기상현상에 따른 제주지역 TSP의 이온조성 변화 특성 (Variation Characteristics of TSP Ionic Compositions by Meteorological Phenomena in Jeju Island)

  • 고희정;김원형;이승훈;부준오;강창희;허철구
    • 한국대기환경학회지
    • /
    • 제27권6호
    • /
    • pp.723-733
    • /
    • 2011
  • The ionic compositions were analyzed from the TSP samples collected at Gosan site in Jeju Island between 2000 and 2008, in order to examine the characteristics of atmospheric aerosols in accordance with the meteorological conditions. For the Asian Dust influence on the ionic compositions, the concentration ratios of $NH_4{^+}$, nss-${SO_4}^{2-}$, $NO_3{^-}$, and $K^+$ were about 1.2~2.3 during Asian Dust over Non-Asian Dust periods, noticeably that of nss-$Ca^{2+}$ was 6.8. Meanwhile the concentrations of nss-${SO_4}^{2-}$, $NO_3{^-}$, and $NH_4{^+}$ have increased as 1.8~4.4 times during the haze event periods, and 1.0~1.6 times during the fog and mist events. The ion balance has resulted that the anionic concentrations are relatively lower than the cationic concentrations, and the discrepancy appears more decidedly as a strong Asian Dust effect. The ammonium ion balance has shown that it exists as a mixture of $NH_4HSO_4$ and $(NH_4)_2SO_4$. The concentration ratios of nss-${SO_4}^{2-}/NO_3{^-}$ for Asian Dust, haze, fog-mist, and non-event periods were respectively 1.8, 5.9, 4.6, and 2.9, which were higher values compared to those in urban areas of China as well as other domestic regions. Especially, the high ratios of sulfur oxides could be presumed by the fact that the longrange transport of air pollutants from Asia continent might affect the atmospheric aerosols of Jeju Island.

GEV 분포를 이용한 대구·경북 지역 일산화탄소 농도 추정 (The estimation of CO concentration in Daegu-Gyeongbuk area using GEV distribution)

  • 류수락;엄은진;권태용;윤상후
    • Journal of the Korean Data and Information Science Society
    • /
    • 제27권4호
    • /
    • pp.1001-1012
    • /
    • 2016
  • 대기오염물질이 인간의 건강에 악영향을 미치는 사실은 잘 알려져 있다. 유엔 환경 계획 (united nations environment program; UNEP) 보고서에 따르면, 미세먼지와 일산화탄소 오염물질로 연간 전 세계에서 430만 명이 목숨을 잃었다. 일산화탄소는 탄소와 산소로 구성된 화합물로 가정에서 생성되는 독성 가스 중 가장 위험한 가스이다. 연구를 위하여 2004년부터 2013년까지 10년간 대구 경북 지역의 대기오염관측소에서 관측된 1시간, 6시간, 12시간, 24시간 평균 일산화탄소 농도 자료를 사용하였다. 일반화 극단치 분포의 모수는 최우추정법과 L-적률추정법을 통해 추정하였고 적합도 검정을 수행하였다. 본 연구의 표본 수가 크지 않으므로 L-적률추정법이 최대우도법에 비해 모수추정에 적합하였다. 또한, 5년, 10년, 20년, 40년 재현수준을 추정하여 대구 경북 지역 일산화탄소 위험지역을 살펴보았다.