• Title/Summary/Keyword: Air pollutants concentration

Search Result 613, Processing Time 0.028 seconds

A Study for Spatial Distribution of Principal Pollutants in Daegu Area Using Air Pollution Monitoring Network Data (도시대기측정망 자료를 이용한 대구지역 대기오염물질의 공간분포에 관한 연구)

  • Ju, Jae-Hee;Hwang, In-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.545-557
    • /
    • 2011
  • The objective of this study was to estimate the trends of each pollutant using the air pollution monitoring networks data from January 2005 to December 2008 in Daegu area. Also, the spatial characteristics of each pollutant were determined using the Pearson correlation coefficients and COD (coefficients of divergence). In this study, the trends of hourly, monthly, seasonal, and total average concentrations of each pollutant for the 10 sites were analyzed. The Ihyeon site showed highest concentration for the $SO_2$, $NO_2$, and PM10}. In the case of $O_3$, the Jisan site showed highest concentration among the other sites. Also, industrial area presented highest concentration for the $SO_2$, CO, and PM10. On the other hand, $NO_2$ showed highest in commercial area. The IDW (inverse distance weighting) method was used to estimate characteristics of spatial distribution. The results provide identify spatial distribution for each pollutant. Also, the Pearson correlation coefficients and COD values provide spatial variability among the monitoring sites. The COD of each pollutant showed very low values for all of the sites pairs. On the other hand, the Pearson correlation coefficients showed high values for all of the sites pairs. Finally, analysis of spatial variability can be used to characterize the spatial uniformity and similarity of concentrations from each pollutant.

Evaluation of Contribution Rate of PM Concentrations for Regional Emission Inventories in Korean Peninsula Using Brute-force Sensitivity Analysis (Brute-force 방법을 이용한 한반도 미세먼지 농도에 대한 배출원의 기여도 산출 연구)

  • Lee, Soon-Hwan;Lee, Kang-Yeol
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1525-1540
    • /
    • 2015
  • In order to clarify the contribution rate of PM concentration due to regional emission distribution, Brute force analysis were carried out using numerical estimated PM data from WRF-CMAQ. The emission from Kyeongki region including Seoul metropolitan is the largest contribution of PM concentration than that from other regions except for emission of trans-country and source itself. Contribution rate of self emission is also the largest at Kyeongki region and its rate reach on over 95 %. And the rate at Gangwon region also higher than any region due to synoptic wind pattern. Due to synoptic wind direction at high PM episode, pollutants at downwind area along from west to east and from north to south tends to mix intensively and its composition is also complicated. Although the uncertainty of initial concentration of PM, the contribution of regional PM concentration tend to depend on the meteorological condition including intensity of synoptic and mesoscale wind and PM emission pattern over upwind region.

The Influences of Concentration Distribution and Movement of Air Pollutants by Sea Breeze and Mist around Onsan Industrial Complex (온산공업단지 주변의 박무와 해풍발생이 대기오염물질의 이동 및 농도분포에 미치는 영향)

  • Lee, Hyung-Don;Lee, Gou-Hong;Kim, In-Deuk;Kang, Ji-Soon;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.95-104
    • /
    • 2013
  • Onsan Industrial Complex located in a nearby the Ulsan Petrochemical Complex and in the east of the coast. For this reason, air pollution substances emitted by Onsan Industrial Complex especially tend to have an effect on meteorological factors such as sea breeze. In this study, we assessed the frequency of sea breeze and mist using the meteorological data, and analyzed potential temperature and upper wind condition for assessment of atmospheric pollution concentration influenced by meteorological phenomena in a nearby the Onsan industrial complex. From an analysis results, when mist and sea breeze happened, each higher concentration phenomenon of $PM_{10}$ and $SO_2$ appeared each 57.2%, 71.8% and 46.6%, 57.7% respectively. Hence, we confirmed that meteorological phenomena such as mist and sea breeze had an effect on high concentration of air pollution substances in the research area. Analytical result of meteorological data in upper layer using potential temperature and wind condition, we confirmed that advection of air pollution substances emitted in Ulsan Petrochemical Complex by sea breeze have an effect on high concentration in Onsan Industrial Complex and nearby the residential area. In particular;concentration in Onsan Industrial Complex were higher than the average concentration by a factor of more than over 1.5 times when sea breeze by stable condition in atmospheric layer appeared.

Concentration and Gas-particle Partition of PCDDs/Fs and dl-PCBs in the Ambient Air of Ansan Area (안산지역 대기 중 다이옥신 및 dl-PCBs의 오염특성 조사)

  • Heo, Jong-Won;Kim, Dong-Gi;Song, Il-Seok;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.517-532
    • /
    • 2010
  • After establishment of Banwol industrial complex in 1987, Ansan city becomes the largest industrial sector development in Gyeonggi-do, Korea. As the population and industrial activity grow over this region, toxic air pollutants, particularly POPs (Persistent Organic Pollutants) from various emission sources have been major public concerns. Air samples for POPs monitoring were collected at the industrial sites ($A_2$), residential sites ($B_1$, $B_2$), commercial site (C), and rural/remote site (D) of the area of Ansan during 2008 with a prolonged industrial sampling site $A_1$ from 2001 to 2008. All samples were analysed for 2,3,7,8 substituted-polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) and dioxin like polychlorinatd diphenyls (dl-PCBs). In site $A_1$, a steady decline of their concentrations from 2003 to 2008 was observed due to the reinforced emission guideline from waste incinerators. The average concentration of the PCDD/Fs and dl-PCBs ranged between 0.118 pg-TEQ/$m^3$ (rural/remote site D) and 0.532 pg-TEQ/$m^3$ (industrial area $A_2$). These level were generally consistent with previous studies in Gyeonggi-do, while higher than other places. Most of PCDD/Fs congener were partitioned into particle phase, whereas dl-PCBs were partitioned into gas phase. The logarithm of gas-particle partition coefficient $K_P$ of dl-PCBs and PCDD/Fs were well correlated with sub-cooled liquid vapor pressure $P_L$. The slope $m_T$ of log $K_P$ versus log $P_L$ for PCDD/Fs (-1.22) and dl-PCBs (-1.02) in industrial area ($A_2$) were high compared to other residential/commercial area. It suggests that this area was likely influenced by the direct emission source of PCDD/Fs and dl-PCBs. To simulate the partition of PCDD/Fs and dl-PCBs between gas and particle phase, Junge-Pankow model ($P_L$-base) and $K_{oa}$ model were applied. It was found that J-P model was more suitable than the $K_{oa}$ model in this study.

An Analysis of Indoor Air Quality and Risk Assessment for One-room Housing around the University in the Post-Corona Era (포스트 코로나 시대의 대학교 주변 원룸형 주택에 대한 실내 공기질 분석 및 위해성 평가)

  • Bao, Wei;Jung, Jaeyoun;Jeong, Insoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.3
    • /
    • pp.23-30
    • /
    • 2022
  • In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO2 concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO2, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E-4, and the ECR figure in September was 3.65E-4, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E-4, six times higher than R7 measured in October, and 1.87E-4 in July, four times higher than R9.

Unambiguous Identification of Fugitive Pollutants and Determination of Annual Emission Flux as Diurnal Monitoring Mode

  • Chang, Shih-Yi;Tso, Tai-Ly;Lo, Jiunn-Gung;Huang, Jer-Luen;Lin, Cheng Ming
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.731-738
    • /
    • 1995
  • Toxic air pollutants are investigated in a petrochemical industrial park in Taiwan by using a movable open path FTIR. The results show the qualitative and quantitative analysis of emission gases from plants, and also provide the emission rate of different compounds. More than twenty compounds under usual operation are found from this industrial park. The concentration variation with time can be correlated exactly with wind direction. It means that by changing the measuring points, the source of emission can be unambiguously identified. An EPA proved PAL model is applied to estimate the emission rate of either a point or an area source. Local atmospheric stability is determined by releasing the $SF_6$ tracer. The origins of errors come mainly from the uncertainty of source's configuration and the variation of meteorological condition. Through the continuous measurement (half an hour base in this study) of OP-FTIR sensor, the maximum value of emission rate and the annual amount of emission can be derived. The emission rate of the measured toxic gases are derived by the model technique and the results show that the emission amount are in the order of ten to hundred tons per year.

  • PDF

Effect of Electrode Process Variables in case of Decomposition of $NO_{x}$ by SPCP (연면방전에 의한 질소산화물의 분해시 전극 공정변수에 대한 영향)

  • 안형환;강현춘
    • Journal of the Korea Safety Management & Science
    • /
    • v.1 no.1
    • /
    • pp.241-258
    • /
    • 1999
  • For hazardous air pollutants(HAP) such as NO and $NO_{2}$ decomposition efficiency, power consumption, and applied voltage were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of HAP with various electric frequencies(5~50 kHz), flow rates(100~1,000 mL/min), initial concentrations(100~1,000 ppm), electrode materials(W, Cu, Al), electrode thickness(1, 2, 3 mm) and number of electrode windings(7, 9, 11) were measured. Experimental results showed that for the frequency of 10 kHz, the highest decomposition efficiency of 94.3 % for NO and 84.7 % for $NO_{2}$ were observed at the power consumptions of 19.8 and 20W respectively and that decomposition efficiency decreased with increasing frequency above 20 kHz. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3 mm in this experiment. As the electrode material, decomposition efficiency was in order : tungsten(W), copper(Cu), aluminum(Al).

  • PDF

Characteristics and Management of Particulate Matter(PM2.5) Emission on Cooking Condition (주방 조리시 미세먼지(PM2.5) 배출 특성과 관리방안)

  • Lee, Myeonggu;Jeong, Myeongjin;Kang, Minji
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.325-329
    • /
    • 2018
  • There are many pollutants in the residential space due to building materials, ventilation, cooking, etc. Among them, particulate matter is a primary carcinogen and very harmfull to the human body, it occurs mostly in cooking. Therefore, in order to manage the indoor air quality well, it is necessary to evaluate the relationship between the concentration of particulate matter generated during cooking and ventilation method. In this study, we propose a management method and particulate matte which occurs during the kitchen cooking by measuring and analyzing the concenteation change of particulate matter(PM2.5) according to the type of food and the ventilation method.

Collection characteristics of wet-type rotating porous disk system for air pollutants removal of marine diesel engines (박용디젤기관의 대기오염 저감을 위한 습식 회전형 다공성 디스크 시스템의 집진특성)

  • Yoa, Seok-Jun;Jang, Chang-Ik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.318-325
    • /
    • 2014
  • The main object of this study is to investigate the collection characteristics of wet-type rotating porous disk system experimentally. The experiment is carried out to analyze the pressure drop and collection efficiency for the present system with the experimental parameters such as system inlet velocity, stage number, tube diameter, inlet concentration, etc. In results, for the present system, at 5 stage and ${\upsilon}_{in}=1.8m/s$, the pressure drop becomes significantly lower as $64mmH_2O$ in comparison with that of the conventional wet type scrubber (Venturi scrubber, over $250mmH_2O$). The collection efficiencies increase with higher inlet velocity showing 92, 95.7, 98.4%, while $SO_2$ removal efficiencies decrease with increment of inlet velocity as 80, 65, 50% at ${\upsilon}_{in}=1.08$, 1.44, 1.8 m/s and tube diameter $D_t=10mm$, respectively. The present system is to be considered as an effective compact system for a simultaneous removal of particle/gas phase pollutants from marine diesel engines.

Infant target facilities and facilities for children in elementary school Comparison and Improvement of Indoor Air Quality for Research (영유아 대상 시설의 실내공기질 특성 비교 및 개선방안에 대한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.591-601
    • /
    • 2013
  • In modern society, we are living indoor at 80 - 90 % or more of the day, therefore most people are exposed to unconscious indoor air pollutants by various causes. When mother and infant, whose level of immunity are weak, are exposed to polluted indoor air, respiratory diseases and atopy can occur by the growth of bacteria. Therefore, appropriate indoor air quality management is important especially at nursery, elementary school and postpartum clinic etc. In this study, we compared the characteristics of the indoor air qualities of primary school facilities and infant facilities. In this study, seasonal effects were investigated. Also the effects of individual activity area were studied for indoor air quality. During summer season(May-August), the air qualities of each 16 elementary school and nursery school were investigated. During winter season(October-december), the air qualities of each 10 elementary school and nursery school were investigated. As a result, during winter season in 10 of 16 nursery school, $CO_2$ concentration exceeded regulation level of 1000 ppm. This resulted from the operation of heating system and poor ventilation. Also the air quality of all parameters during winter season were worse than during summer, maybe due to poor ventilation. Except HCHO, the concentrations of other parameters were higher in nursery school. This seems to result from relatively low individual activity area of nursery school than elementary school. From this research, more strong regulation for ventilation and installation of air purifier should be implemented.