• Title/Summary/Keyword: Air pollutants concentration

Search Result 613, Processing Time 0.03 seconds

Air Quality Impact Analysis for Point Sources Using Three-Dimensional Numerical Models (삼차원 수치모델을 이용한 점오염원의 대기환경영향 평가)

  • 김영성;오현선;김진영;강성대;조규탁;홍지형
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.4
    • /
    • pp.331-345
    • /
    • 2001
  • The increase of carbon monoxide in the ambient air due to the emissions from point sources without control was estimated using three -dimensional numerical models. The target area was Ulsan where one of the largest industrial complexes was located. As a typical example using numerical models for air quality impact analysis of criteria pollutants that will determine whether the air quality standards would be exceeded or not, the following approaches were suggested. They include: (1) investigation of pre-existing atmospheric conditions, (2) identification of major factors causing high concentrations, (3) selection of episode days. (4) preparation of three-dimensional meteorological data, (5) confirmation of agreement between measured and predicted concentrations in the emission conditions of episode days, and (6) estimation of the impact due to changes of the emission conditions. In the present work, daily meteorological conditions for the specific period were classified into four clusters of distinctive features, and the episode days were selected individually from each cluster. Emphasis was placed on the selection of episodes representing meteorological conditions conducive to high concentrations especially for point sources that were sensitive to the wind direction variations.

  • PDF

The Effect of 2008 Beijing Olympic on Korean Air Quality (2008년 북경 올림픽이 한반도 대기질에 미치는 영향)

  • Song, Hyung-Do;Choi, Jin-Soo;Hong, Sung-Chel;Chang, lim-Seok;Kim, Jung-Soo;Lee, Suk-Jo
    • Journal of Environmental Science International
    • /
    • v.18 no.6
    • /
    • pp.655-665
    • /
    • 2009
  • This study aims to identify the impacts of air quality in the Korean Peninsula according to the China's environmental policies in preparation of the Beijing 2008 Olympic Games. The measurement of emission variations in China, aircraft measurement, and modelling were carried out. The reduction measures in Beijing, China and its emission changes resulted in $30{\sim}65%$ in decrease out of the total emissions within the Beijing region, whereas when it comes to the whole nation of China, the reduction rate was about $4{\sim}9%$. Comparing the concentration of the air pollutants in Seoul and Ganghwa in August 2008 during around the period of Beijing Olympic Games with one in $2004{\sim}2007$ showed that the $SO_2$ concentrations in the past was above 5ppb, while the concentration in the 2008 olympic period was 4ppb and below. The NOx at the Seokmori site in Ganghwa tended to be lower in concentration in 2008 than in between $2004{\sim}2007$. As for $O_3$ and $PM_{2.5}$, the concentration tended to be rather low since August 11. The air current track that showed during the period of aircraft measurement presented to be flowed into Korea through the Northeast part of China and the coast of Bohai Bay, while the concentrations of $SO_2$. NOx, and $O_3$ over the west sea on August 20 and 24 were 0.54 (0.28ppb), 0.86 (1.84ppb), and 54.0 (41.5ppb) respectively, similar or lower than the ones measured in the past in the similar current patterns. The modelling result showed similar patterns to the data of aircraft measurement, in particular in $SO_2$. Overall, the reduction measures in Beijing, China affected directly and indirectly the air quality in the Korean peninsular, but the impact was not significant as it was momentary and limited to the intended area.

A Comparative Study on the Ambient Air Quality Standard Strength among Korea, the U.S.A. and the EU (우리나라, 미국 및 유럽의 대기환경기준 강도에 관한 비교 연구)

  • Park, Min-Bin;Lee, Tae-Jung;Lee, Eun-Sun;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.6
    • /
    • pp.559-574
    • /
    • 2016
  • Based on air quality monitoring data ('10~'14) of Suwon City provided by the Korean Department of Environment, a fundamental statistic for 5 criteria pollutants such as $SO_2$, CO, $NO_2$, $O_3$, and $PM_{10}$ was initially investigated. The purpose of this paper was to review the ambient air quality standards(AAQS) of Korea, the U.S.A. and the EU and further to assess the degree of standard strength by the achievability of the AAQS comparing each national standard. Since the level and the way of standards for each air pollutant are various among countries, it is difficult to determine the degree of relative attainment using the same set of data above. Further when all the areas having bad air quality for a specific pollutant are classified as non-attainment case, it is more difficult to assess the degree of standard strength. Thus we introduced a new concept called the average concentration distance (ACD) to quantitatively estimate the strength. As results, the Korean 1-hr $NO_2$ AAQS is slightly stronger than the US standard and weaker than the EU standard. The Korean $O_3$ standard is strongest; however, the Korean $PM_{10}$ standard is weakest. Furthermore the equivalent levels of 8-hr $O_3$ standards in the U.S.A. and the EU were respectively estimated as 97.5 and 95.7 percentiles of the Korean standard with maintaining the existing standard of 60 ppb.

Research about room air quality of department store underground parking lot (백화점 지하 주차장의 실내 공기질에 관한 연구)

  • Kim Ki-Tae;Yang Sung-Su;Son Bu-Soon;Jeon Young-Taek;Jang Bong-Ki;Lee Jong-Dae
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.44-51
    • /
    • 2006
  • This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.

Effects of local circulation on transport of air pollutants and occurrence of high concentration in industrial area (공단지역의 국지순환이 대기오염물질의 수송과 고농도 발생에 미치는 영향)

  • 임윤규;김유근;오인보
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.411-412
    • /
    • 2003
  • 일반적으로 공단지역의 경우 대기 중으로 배출된 다량의 대기오염물질이 대기정체 조건 하에 국지적으로 축적되어 고농도 현상이 나타나게 된다. 하지만 국지순환이 뚜렷이 나타나는 지역의 경우 대기오염물질의 지역적 수송현상을 경험하게 되며 풍하측 고농도현상이 빈번히 나타나게 된다. 이러한 대기오염물질 수송현상은 연안에 인접한 공단지역에서 보다 뚜렷이 나타나는데, 이것은 육풍 효과에 의해 바다로 밀려간 기괴내의 대기오염물질이 수면의 낮은 침적에 의해 (Entwistle et al, 1997) 일정 농도로 유지되고 다시 해풍에 의해 기괴가 내륙으로 수송되기 때문이다. (중략)

  • PDF

A Study on the Gasification of Combustible Waste (가연성 폐기물의 가스화에 관한 연구)

  • 정준화
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.89-95
    • /
    • 1990
  • This study was investigated to the energy recovery by the pyrolysis of waste tyre. the pyrolysis of the waste tyre was made by using the pyrolysis chamber for the gasification and the combustion chamber for the combustion of the pyrolysis gas. In batch system, the amount of waste tyre was put 150kg in the pyrolysis chamber and the proper air flow rate for the stable production of the pyrolysis gas was 0.95Nm$^{3}$ /min. the production time of the pyrolysis gas was stable above 210minutes, and the stable production rate was above 3.8Nm$^{3}$ /min. The production temperature of pyrolysis gas was 170$^{\circ}$C and combustion temperature of pyrolysis gas was 1,000$^{\circ}$C. The combustible component of washing gas in pyrolysis gas of waste tyre was CO, CH$_{4}$, $C_{2}H_{6}$ and $C_{3}H_{8}$, and total amount was 22.7%. Heat value of condensed material was 9,804Kcal/kg. The average concentration of air pollutants between cyclone and scrubber was CO 420.4ppm, SO$_{x}$ 349.8ppm. NO$_{x}$ 68.Sppm, HCl 24.4ppm and Dust 240.0g / Nm$^{3}$, respectively.

  • PDF

A Study on the Development of Air Pollution Model Applicable to the Complex Terrain (복잡지형에서의 대기순환모델에 관한 연구)

  • Yoon J. Y.;Yi S. C.;Hong M. S.
    • Journal of computational fluids engineering
    • /
    • v.2 no.1
    • /
    • pp.109-116
    • /
    • 1997
  • The objective of this paper is to develop a computational model for the prediction of the pollutant spread from a mass source over a complex terrain. The model comprises a two-dimensional, steady state flow model and a concentration model which employs the results of the computed flow field. The computational model is applied to predict the spread of pollutants for Sanbon city, and the two cases have been compard with the results of SF/sub 6/ trace experiments.

  • PDF

Concentration Characteristics of Acidic Air Pollutants in the Summer and Winter Seasons (여름과 겨울철 산성오염 물질 농도 특성)

  • 이학성;강병욱;정용승;이지영;김재섭
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.127-129
    • /
    • 2000
  • 산성오염물질과 미세입자($PM_{2.5}$)는 인체 및 생태계에 많은 악 영향을 미치고 있다. 특히 미세입자와 미세입자의 주성분인 ${SO_4}^{2-}$, ${NO_3}^{-}$, ${NH_4}^{+}$, 원소탄소(EC), 유기탄소(OC)는 호흡기 계통의 질병 및 시정장애에 커다란 영향을 미치는 것으로 알려지고 있다(Pope et al., 1995; Reichhardt, 1995; Chow et al., 1993; Conner et al., 1991; Spongier et al., 1990). 미세입자는 연소과정에서 직접 배출되거나 대기 중에서 응집, 휘발성 물질의 응축, 가스에서 입자로의 전환 등에 의하여 이차 입자상 물질로 생성된다(Seinfeld, 1986). (중략)

  • PDF

A study of decomposition of sulfur oxides using Calcium hydroxide catalyst by plasma reactions (Ca(OH)2촉매를 이용한 플라즈마 반응에 의한 황산화물의 제거에 관한 연구)

  • Kim, Da Young;Woo, In Sung;Lee, Sun Hee;Kim, Do Hyeon;Kim, Byeong Cheol
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.547-560
    • /
    • 2013
  • In this study, the air pollutant removal such as sulfur oxides was studied. A combination of the plasma discharge in the reactor by the reaction surface discharge reactor Calcium hydroxides catalytic reactor and air pollutants, hazardous gas SOx, changes in gas concentration, change in frequency, the thickness of the electrode, kinds of electrodes and the addition of simulated composite catalyst composed of a variety of gases, including decomposition experiments were performed by varying the process parameters. The experimental results showed the removal efficiency of 98% in the decomposition of sulfur oxides removal experiment when Calcium hydroxides catalysts and the tungsten(W) electrodes were used. It was increased 3% more than if you do not have the catalytic. If added to methane gas was added the removal efficiency increased decomposition.

  • PDF

Reduction Methods of Indoor hiy Quality on the Subway Station using by Ventilation (환기를 이용한 지하 역 실내 공기질 개선 방안)

  • 박덕신;정병철;조준호;정우성
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.139-146
    • /
    • 2001
  • Modern people stay at indoor places about 90% of a day. Radon-222 is a gas produced radioactive decay of the element radium. And, radon is one of the major indoor air pollutants moves into the underground space through various routes and is considered to cause lung c hurting the lung tissues, In this study, we measured the subway radon level at 9 stations o According to test results, we can figure out the concentration of radon by lines, times, and m points. So, it was found that ventilation conditions are the most important factors in the su quality. Finally, we suggested effective and economic management methods of air pollution subway.

  • PDF