• Title/Summary/Keyword: Air pollutants concentration

Search Result 613, Processing Time 0.025 seconds

Monitoring of Particulate Matter and Analysis of Black Carbon and Some Particle Containing Toxic Trace in the City of Yaoundé, Cameroon

  • Tchuente, Siaka Y.F.;Saidou, Saidou;Yakum, N.Y.;Kenmoe, N.X.;Abdourahimi, Abdourahimi
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.120-128
    • /
    • 2013
  • The concentration and composition of particulate matter (PM) in the atmosphere can directly reflect the environmental pollution. The atmospheric pollution in some Cameroonian cities is increasing with the industrial development and urbanization. Air pollution is inherently complex, containing PM of varied size and composition. This PM exists as a dynamic cloud interacting with sunlight and is modified by the meteorology. The reflectometer and the EDXRF spectrometry are applied to determine the concentration of some specific elements at four sites in the city of Yaound$\acute{e}$. The particular aim of the present work is to put in place data base on air pollution in urban area and elaborate regulations on the emissions issued to industrial and vehicle activities. This study provides an overview of the concentration of black carbon and some specific elements in the air, which have impacts on human health. The measurement was done by distinguishing the size of particle. So that, the particle with aerodynamic diameter between $2.5-10{\mu}m$ (so-called coarse particle) and aerodynamic diameter < $2.5{\mu}m$ (so-called fine particle) were considered to obtain more information about levels of the inhalable fraction of the location. The results obtained in four locations of the city of Yaound$\acute{e}$ show that the black carbon concentration is very considerable, the element sulfur is a major pollutant and the concentration of fine particle is very greater. The results obtained of fine and coarse filters range from $5-17{\mu}g/m^3$ and $10-18{\mu}g/m^3$ for the black carbon. S, Cu, Zn, Pb, Cd, As, Se and Hg are the specific findings of this work. The pollutants with a greater concentration are S, Pb, and Zn. These later seem to be non-uniformly, non-regular in some location and high compared to other countries. This work allows us to make a potential relation between pollutants and emission sources. In this framework, some suggestions have been proposed to reduce emissions for an improvement of the air quality in the environment and thus, the one of the city of Yaound$\acute{e}$.

Air Quality Improvement Scenario for China during the 13th Five-Year Plan Period

  • Tang, Qian;Lei, Yu;Chen, Xiaojun;Xue, Wenbo
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.33-36
    • /
    • 2017
  • China is suffering from severe air pollution especially fine $PM_{2.5}$ pollution. In 2015, the annual average $PM_{2.5}$ concentration of the 338 municipal cities was $50{\mu}g/m^3$, 78% cities at or above the prefectural level failed to comply with the $PM_{2.5}$ concentration standards. The $13^{th}$ Five-Year Plan for National Economic and Social Development set the goal that the annual average concentration of $PM_{2.5}$ in the municipal cities which failed to attain the ambient air quality standards shall be decreased by 18% by 2020 (CCCPC, 2016). In this study, an air pollution control scenario during the $13^{th}$ Five-Year Plan period was proposed and the $SO_2$, $NO_x$ and PM emission reductions in response to different measures in 31 provincial-level regions mainland China by 2020 were estimated. The air quality in the target year (2020) was simulated using the WRF-CMAQ model. The results showed that by 2020, the emissions of $SO_2$, $NO_x$ and primary PM in mainland China will be reduced by 4.19 million tons, 3.94 million tons and 4.41 million tons, a drop of 23%, 21% and 25% respectively compared with that in 2015, and the annual average concentration of $PM_{2.5}$ will decrease by 19%. Coal-fired power plant contributes the most pollutant emission reduction.

Effects of Building-roof Cooling on Scalar Dispersion in Urban Street Canyons (도시 협곡에서 건물 지붕 냉각이 스칼라 물질 확산에 미치는 영향)

  • Park, Soo-Jin;Kim, Jae-Jin
    • Atmosphere
    • /
    • v.24 no.3
    • /
    • pp.331-341
    • /
    • 2014
  • In this study, the effects of building-roof cooling on scalar dispersion in three-dimensional street canyons are investigated using a computational fluid dynamics (CFD) model. For this, surface temperature of building roof is systematically changed and non-reactive pollutants are released from street bottom in urban street canyons with the aspect ratio of 1. The characteristics of flow, air temperature, and non-reactive pollutant dispersion in the control experiment are analyzed first. Then, the effects of building-roof cooling are investigated by comparing the results with those in the control experiment. In the control experiment, a portal vortex which is a secondary flow induced by ambient air flow is formed in each street canyon. Averaged air temperature is higher inside the street canyon than in both sides of the street canyon, because warmer air is coming into the street canyon from the roof level. However, air temperature near the street bottom is lower inside the street canyon due to the inflow of cooler air from both sides of the street canyon. As building-roof temperature decreases, wind speed at the roof level increases and portal vortex becomes intensified (that is, downdraft, reverse flow, and updraft becomes stronger). Building-roof cooling contributes to the reduction of average concentration of the non-reactive pollutants and average air temperature in the street canyon. The results imply that building-roof cooling has positive effects on improvement of thermal environment and air quality in urban areas.

An Analysis on the Actual Condition of Indoor Air Quality in Rural House (농촌지역 노후주택의 실내공기환경 실태분석 연구)

  • Park, Roun;Cho, Sukyeong;Kim, Sangbum
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.9-17
    • /
    • 2020
  • The ratio of the deterioration housing in rural area was 29.6%, but it was 18.3% in urban area based on a 2018 survey. In consideration of the point, this study aims to analyze the actual condition of indoor air quality in rural houses to provide basic data for improving the indoor air environment. It was investigated 15housings of Hongseong-gun, Chungchengnam-do. To investigate the correlation between indoor air quality and housing type, both the field survey of housing type and precision diagnosis of concentration of indoor air pollutants such as HCHO, TVOC, Fine dust(PM-10, PM-2.5), CO2, Radon. The results of this study are as follows. First, according to the average value of each element of rural old housing, the construction year was distributed in 1939~2004, and 12households(80%) living in houses older than 30years have passed for about 46years. As for the housing area, more than 12houses(80%) of 60㎡ or more and 3 houses (20%) of less than 60㎡ were often living in relatively small-scale housing. Second, as a result of measuring indoor air pollutants in rural houses, substances exceeding the standard values were found in HCHO, TVOC, CO2. Third, in the case of Fine dust and Radon, none of such factors were exceeded the standard. Fourth, there was no significant difference in indoor air quality depending on housing type in rural houses. This paper is expected to contribute to the regional development projects and effective implementation of rural policies.

A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites (환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구)

  • Lee, Jeong Joo;Lee, Ju Sang;Kim, Shin Do
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF

Effective Control of Indoor Air Pollutant using VAV/BPFS (VAV/BPFS를 이용한 실내공기 오염물질의 효율적 제어)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.327-334
    • /
    • 1998
  • The oil crisis of the 1970s and the rise in oil prices motivated people to implement energy conservation strategies. Buildings were fitted with additional Insulation and reduced ventilation rates. The reduction of mechanical and natural ventilation rate led to Increases In Indoor pollutant concentrations which result- ed In Increased health risks from Indoor exposure to pollutants. The variable-air-volume /bypass fitration system/VAV/BPFS) is a variation of the conventional VAV systems, The VAV/BPFS is an electronically controlled system that provides costegectlve thermal comfort and acceptable indoor air quality Under controlled conditions In a chamber, a series experiments were performed to compare the ability of a VAV/BPFS to remove Indoor aerosol concentration and to reduce energy consumption no that ability of conventional VAV system. Results show that the VAV/BPFS Increases the effective ventilation rate and removes indoor air pollutant, and maintains acceptable indoor air Quality without sacrificing energy consumption.

  • PDF

The Study on the Level of Air Pollution at Four Department Stores in Pusan Area (부산지역 4개 백화점의 공기오염도에 관한 조사연구)

  • Moon, D.H.;Rhee, HW.;Lee, C.U.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.164-180
    • /
    • 1991
  • For the purpose of contributing to the promotion of health of the employees working at the same kind of department store or similar type of business and the people utilizing them and preparing the basic data for the establishment of mangagement measure by assessing the level of air pollusion at indoor and outodoor of four department store among the distribution service business in Pusan area, authors measured the concentration of sulfur dioxide, nitrogen dioxide, formaldehyde and total suspanded particle according to the measuring height of variable at indoor and outodoor from Aug. 1990. to sep. an. d Jan, 1991 to Feb.: for each two months in summer and winter, and studied by dividing the variable factor into atmospheric factor (temperature, humidity and air velociy) The results are as follows ; 1. The mean concentration of air pollutants at indoor to total subjects was nitrogen dioxide 31.1ppb, sulfur dioxide 51.7ppb, formaldehyde 162.lppb and total suspanded particle $67.7{\mu}g/m^3$, and it was higher in winter than in summer (P>0.05) 2. The mean concentration of formaldehyde to total subjects was higher indoors than outdoors (P<0.001), in case of nitrogen dioxide there was no significant difference and sulfur dioxide and total suspanded particle were higher outdoors than indoors (P<0.05) 3. The concentration of nitrogen dioxide and sulfur dioxide proved to be a adverse correlation, reducing with height. 4. According to the result questioned about the exposure concentration of pollutant and the general symptom caused by the pollutant, nitorgen dioxide and symptom proved to be a positive correlation (P<0.09).

  • PDF

Characteristics of VOCs Emission According Interior Finish Materials and Working Phases of New Apartments (신축 아파트의 실내 마감재 변경 및 시공단계별 휘발성유기화합물 발생 특성)

  • Pang, Seung-Ki;Cho, Woo-Jin;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.486-492
    • /
    • 2006
  • In this research, IAQ is measured to evaluate the emission performance of VOCs in three new apartment houses finished by totally EFMs (Environmental Friendly Material), partially installed EFMs and general materials. Among various VOCs, Target pollutants for the IAQ measurement are benzene, ethylbenzene, toluene, xylene, 1,4-Dichlorobenzene and formaldehyde. The measurement is conducted one day after each interior finishing material is worked over by construction schedule. The result of this research concluded that (1) Except toluene, the concentration levels of each pollutant did not exceed the national IAQ standards in all test residences, (2) As the interior finishing work schedule, A toluene level peaked when the furniture installing was ended. (3) The toluene concentration level of the house installed general interior materials as the non-EFMs furniture was one and half higher than other houses. Consequently, installing. the furniture made by EFMs is one of effective methods to improve the IAQ for new apartment houses.

Analysis of the Correlation between Urban High Temperature Phenomenon and Air Pollution during Summer in Daegu

  • An, Eun-Ji;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.28 no.10
    • /
    • pp.831-840
    • /
    • 2019
  • Recently, summer high temperature events caused by climate change and urban heat island phenomenon have become a serious social problem around the world. Urban areas have low albedo and huge heat storage, resulting in higher temperatures and longer lasting characteristics. To effectively consider the urban heat island measures, it is important to quantitatively grasp the impact of urban high temperatures on the society. Until now, the study of urban heat island phenomenon had been carried out focusing only on the effects of urban high temperature on human health (such as heat stroke and sleep disturbance). In this study, we focus on the effect of urban heat island phenomenon on air pollution. In particular, the relationship between high temperature phenomena in urban areas during summer and the concentration of photochemical oxidant is investigated. High concentrations of ozone during summer are confirmed to coincide with a day when the causative substances (NO2,VOCs) are high in urban areas during the early morning hours. Further, it is noted that the night urban heat island intensity is large.. Finally, although the concentration of other air pollutants has been decreasing in the long term, the concentration of photochemical oxidant gradually increases in Daegu.

Estimation of Personal Exposure to Air Pollutants for Workers Using Time Activity Pattern and Air Concentration of Microenvironments (시간활동 양상과 국소환경 농도를 이용한 근로자의 유해 공기오염물질 노출 예측)

  • Lee, Hyunsoo;Lee, Seokyong;Lee, Byoungjun;Heo, Jung;Kim, Sunshin;Yang, Wonho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.436-445
    • /
    • 2014
  • Objectives: Time-activity studies have become an integral part of comprehensive exposure assessment and personal exposure modeling. The aims of this study were to estimate exposure levels to nitrogen dioxide($NO_2$) and volatile organic compounds(VOCs), and to compare estimated exposures by using time-activity patterns and indoor air concentrations. Methods: The major microenvironments for office workers were selected using the Time-Use Survey conducted by the National Statistical Office in Korea in 2009. A total of 9,194 and 6,130 workers were recruited for weekdays and weekends, respectively, from the Time-Use Survey. It appears that workers were spending about 50% of their time in the house and about 30% of their time in other indoor areas during the weekdays. In addition, we analyzed the time-activity patterns of 20 office workers and indoor air concentrations in Daegu using a questionnaire and time-activity diary. Estimated exposures were compared with measured concentrations using the time-weighted average analysis of air pollutants. Conclusions: According to the time-activity pattern for the office workers, time spent in the residence indoors during the summer and winter have been shown as $11.12{\pm}2.20$ hours and $12.48{\pm}1.77$ hours, respectively, which indicates higher hours in the winter. Time spent in the office in the summer has been shown to be 1.5 hours higher than in the winter. The target pollutants demonstrate a positive correlation ($R^2=0.076{\sim}0.553$)in the personal exposure results derived from direct measurement and estimated personal exposure concentrations by applying the time activity pattern, as well as measured concentration of the partial environment to the TWA model. However, these correlations were not statistically significant. This may be explained by the difference being caused by other indoor environments, such as a bar, cafe, or diner.