• Title/Summary/Keyword: Air pollutants concentration

Search Result 617, Processing Time 0.032 seconds

Wastewater Treatment Process Study for Used Diaper Recycling (사용 후 기저귀 재활용을 위한 폐수처리방안 연구)

  • Kim, Kyung Shin;Lee, Ho Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.2
    • /
    • pp.24-33
    • /
    • 2015
  • This study aims to suggest wastewater treatment options for diaper recycling by identifying characteristic analysis of wastewater from diaper recycling process and efficiency evaluation of wastewater treatment units. The wastewater characteristic analysis showed that the concentration of organic pollutants and ionic materials were very high comparing to seawater. Through the investigation of similar wastewater treatment, six treatment units were identified to reduce pollutants. It is found UF(ultra-filtration), DAF(dissolved air flotation), fenton oxidation, electro-coagulation and chemical-coagulation are effective in reducing organic pollutants while membrane system and ion exchanger are effective in reducing ionic materials. Even though the target of water quality should be secured in terms of managing organic pollutants level, the application of treatment unit for reducing ionic material needs lots of considerations. This result suggests that reuse of pulping wastewater after controlling organic pollutants is better than direct discharge of pulping wastewater. To select the appropriate wastewater treatment unit, an economic analysis about operation condition, wastewater flow, cost, efficiency should be considered.

Characteristics of VOCs and Formaldehyde Emitted from Floorings (바닥재로부터 방출되는 휘발성유기화합물과 폼알데하이드 특성)

  • Park, Hyun-Ju;Jang, Seong-Ki;Seo, Soo-Yun;Lim, Jun-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.1
    • /
    • pp.38-45
    • /
    • 2009
  • Since the seventies and the oil crisis, energy-saving measures have led to a reduction in the ventilation of room. The use of synthetic materials which emit various chemical substances had led to an increase in the concentration of indoor pollutants. "Sick building syndrome (SBS)" and "Sick house syndrome (SHS)" are worldwide problems. Also, the number of complaints about indoor air pollution caused by VOCs (Volatile organic compound) and HCHO (Formaldehyde) has increased. It is important that evaluating and understanding emission of indoor air pollutant from building materials. The object of this study was to evaluate emission test method for flooring such as wood based flooring, carpet tile, rubber tile, PVC sheet and tile, and to determine emission of TVOC and form-aldehyde. The quantity of TVOC and carbonyl compounds emission were sampled and measured by Tenax TA and gas chromatography/mass spectrometry (GC/MSD), 2,4-DNPH cartrige with ozone scrubber and high performance liquid from flooring. The TVOC concentration emitted from carpet tile was ($7.419\;mg/m^2 h$) the highest among 5 groups of test materials. In wood based flooring and PVC tile, the emitted concentration of toluene was high. And the dodecane emission was highest in carpet. The concentration of TVOC decreased by an increase in emission test period. After 7 days, the concentration of TVOC from floorings were about 50% below of the concentration at the first day. TVOC emission from wood based flooring, carpet tile, rubber tile, PVC sheet and tile were decreased in 28 days and remained steady after about 15 days. The concentration of formaldehyde emission from floorings showed extremely low.

Effect of the Photolysis rate and Initial concentration for the Pollutants on modelled Ozone concentration (반응속도상수와 오염물질의 초기 농도가 오존농도 예측에 미치는 영향)

  • 이화운;김유근;원경미;김희정
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.422-423
    • /
    • 1999
  • 최근 저유황 연료유의 공급과 청정연료의 사용 등으로 인해 1차 오염물질은 점차 줄어드는 추세에 있는 반면, 늘어나는 자동차와 급속한 산업화로 산업시설에서 배출되는 질소산화물과 탄화수소류, 휘발성 유기화합물(VOC) 등이 복잡한 광화학 반응을 통해 2차 오염물질을 생성함으로 대기오염의 문제가 심각하다.(중략)

  • PDF

Characteristics of Volatile Organic Compounds from Newly Produced Building - Apartment House

  • Lee, Jeong-Joo;Kim, Jeong-Ho;Kim, Shin-Do
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.06a
    • /
    • pp.223-226
    • /
    • 2004
  • Building materials emit high concentration volatile organic compounds(VOCs), formaldehyde(HCHO) and other hazardous air pollutants(HAPs) to indoor environment. Average value of VOCs and HCHO emission concentration were $3,770\;{\mu}g/m^3$, $430\;{\mu}g/m^3$ in newly buildings, respectively. VOCs and HCHO emission characteristic are high emission level at initial time and decreased in course of time.

  • PDF

A Study on Concentration Analysis for Decreasing Air Pollutants (대기오염물질 저감을 위한 농도분석에 관한 연구)

  • Kim, Yun-Seon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.28-33
    • /
    • 2007
  • Often Regular Measurement Target 32 Spots which are distributed at Seo-gu in Incheon Metropolitan and Odour Emission Target 100 Factories based on the task instruction of Ministry of Environment in Korea were selected by considering to atmosphere phenomena and regional characteristics etc. This paper aims at building the Decreasing Prediction System of Odour which is capable of comparing and examining the concentration distribution by odour compounds, the distribution maps of odour diffusion and the contribution degree of sphere of influence, which is discharged from these above spots and factories.

The Effect of Traffic Volume on the Air Quality at Monitoring Sites in Gwangju (광주광역시 대기오염측정소 주변 교통량이 대기질에 미치는 영향)

  • Lee, Dae-Haeng;An, Sang-Su;Song, Hyeong-Myeong;Park, Ok-Hyun;Park, Kang-Soo;Seo, Gwang-Yeob;Cho, Young-Gwan;Kim, Eun-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.3
    • /
    • pp.204-214
    • /
    • 2014
  • Objectives: Vehicular emissions are one of the main sources of air pollution in urban areas. Correlation analysis was conducted between air pollutants and traffic volume in order to identify causes of air pollution in Gwangju. Methods: Using traffic volumes and air quality monitoring data from 2002 to 2012 from nine stations (seven urban areas, two roadside areas), especially at three sites where traffic volumes were high, the correlation coefficients were obtained between air pollutants as PM-10 (particulate matter), $NO_2$, $SO_2$, CO and $O_3$ at the stations and traffic volumes near the air monitoring stations. Results: Due to traffic volume and distance between the station and the traffic road, concentrations of pollutants at roadside areas were higher than at urban areas, with the exception of $O_3$. The concentration of $O_3$ showed statistically significance with those of other gas materials as $NO_2$, $SO_2$, and CO in winter (p<0.001) and spring (p<0.05). During the period of October 7 to 20, 2012, excluding periods of yellow dust, smog and rainy season, the ratio of $NO/(NO+NO_2)$ showed the highest value 0.57 and 0.40 at Unam and Chipyeong of two roadside stations, followed by 0.35 at Nongseong with vehicular effects. The correlation coefficient between traffic volume and $O_3$, CO, $NO_2$ became higher when the data on mist and haze days were excluded, than when all hourly data were used in that period, at the three sites of Unam, Chipyeong, and Nongseong. Conclusions: Air quality showed a considerable effect from vehicles at roadside areas compared to in urban areas. Air pollutant diminishment strategies need to be aggressively adopted in order to protect atmospheric environment.

Characteristics of a Wet Air Cleaning System for Removal of Air Pollutants (습식 공기청정장치의 공기오염물질 제거 특성)

  • Bae, Gwi-Nam;Kim, Yong Pyo;Baik, Nam Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.21-31
    • /
    • 2000
  • Performance characteristics of a wet air cleaning system were investigated experimentally, and discussed in relation with physicochemical properties of the target pollutants. The system is composed of an air cleaner, a separator, and a medium filter. Removal efficiency of the system was measured for ambient particles and gaseous air pollutants: $SO_2$, NO, $NO_2$, HCHO, and $NH_3$. For particle removal test, particles were introduced into the system through a fan, and the particle size distribution was measured at three locations by using two laser particle counters. Particle removal efficiency for each system component was obtained from the particle size distribution. It was found that the separator primarily removed coarse particles greater than $5{\mu}m$ in diameter, and that the medium filter mainly removed fine particles less than $5{\mu}m$ in diameter. For gas removal test, air with gaseous air pollutant was injected into the outlet of the fan, and the concentration was measured both at the upstream of the air cleaner and at the downstream of the separator. It was found that the gaseous species with high Henry's law coefficients, such as $SO_2$, HCHO, and $NH_3$, showed high removal efficiency, but the gaseous species with low Henry's law coefficients, such as NO and $NO_2$, showed low removal efficiencies. It was also found that negative ions were generated from the air cleaner.

  • PDF

Health and Environmental Risk Assessment of Pollutants in Pohang (포항지역 오염물질 보건.환경 위해성 평가 -미세먼지의 발생특성 및 농도분포를 중심으로-)

  • Jung, Jong-Hyeon;Choi, Won-Joon;Leem, Heon-Ho;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2719-2726
    • /
    • 2010
  • The purpose of this study was to investigate the scientific basic grounds for the assessment of health and environmental diseases resulting from air pollutants in Pohang. For this study, we investigated pollutants, weather characteristics and concentration distribution of fine particles ($PM_10$) yearly and each season, using data from Air Quality Monitoring Stations. The properties of concentration distribution and seasonal fluctuation of $PM_10$ were studied qualitatively and quantitatively using CALPUFF, air dispersion model. The average concentration of $PM_10$ for each season was spring($75.7{\mu}g/m^3$)>summer($56.8{\mu}g/m^3$)>winter($53.6{\mu}g/m^3$)>fall( $52.7{\mu}g/m^3$). In the case of spring, high concentrations appear due to the Asian dust frequently occurring. The contributions of $PM_10$ classified by the types of pollution source in Pohang were point source 62%>mobile source 33%>area source 5%. An important point is that 97% of emissions were produced from the iron manufacture in steel industry. Therefore, it is necessary to control the emission sources of pollutants and to construct an observation system at Pohang steel industrial complex from now on. It’s time to control the risk factors for health and environmental disease to protect the health of resident in Pohang and its neighboring areas.

A Study on the Relationship of Air Pollution and It's Health Effect (대기오염과 건강영향의 관련성에 관한 연구)

  • 김윤신;전준민;신찬기
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.1
    • /
    • pp.38-52
    • /
    • 1994
  • This study examines three different relation effects of air pollution on health in Seoul city during 1988-90 : an effect on respiratory disease mortality, the frequency of hospital in- patients for asthma, and jogging in the morning. The results seemed likely to show positive association between respiratory mortality and asthma in- patients and ozone concentration. It also suggested that jogging as morning exercise was not recommended in the morning because of the highest concentration of major pollutants in the morning 7 : 00-8'00 a.m ). The epidemiological and statistical investigation of air pollution on health effects to be studied in further detail since these findings have provided some limited conclusions.

  • PDF

Distribution of Airborne Fungi in the Public Facilities (다중이용시설 내 공기 중의 진균 분포)

  • Koh, Yeon-Ja;Gong, Young-Woo;Lee, Jae-Mann;Go, Jong-Myoung;Kim, Yong-Hee;JeGal, Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.4
    • /
    • pp.77-85
    • /
    • 2007
  • Recently, there is increasing interest in indoor air pollution. Fungal spores are one of the pollutants that is the causes of hypersensitivity reactions, bronchial asthma, allergic rhinitis. This study was performed to assess the levels of fungi concentration in public facilities and airborne fungi were collected with the air sampler using DRBC(Dichloran rose bengal chloramphenicol) agar. It was found that airborne fungi concentration were related to the humidity and the people movement. 10 genera of fungi was isolated and identified and the most common culturable fungi were Penicillium, Cladosporium, and Aspergillus.