• Title/Summary/Keyword: Air pollutants concentration

Search Result 617, Processing Time 0.313 seconds

Hydrogen Peroxide Concentrations in Air in Seoul (서울시 대기 중 $H_2O_2$의 농도)

  • 강충민;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.61-68
    • /
    • 2000
  • Gas-phase hydrogen peroxide(H2O2) concentrations were measured to investigate it's distribution in the ambient air in downtown Seoul(Kwanghwamum and Mullae-dong). These measurements were made during four season, from April 30, 1998 to January 29, 1999, using Cold Trap and HPLC. Measurements were also made of other photochemical oxidants and trace gases(O3, NO2, CO and SO2) and meteorological parameters(relative humidity, temperature, solar radiation and wind speed). The mean of all observations was 0.10 ppbv and the range measured was below the level of detection(>0.01 ppbv) to 0.47ppbv. The higher seasonal mean concentrations showed during the summer(0.21 ppbv) and concentrations of H2O2 showed a diurnal variation with maximum concentrations in the afternoon(12:30∼14:00). The results from the corrrelation analysis showed that the concentration of gaseous H2O2 is strongly dependent on the other air pollutants(NO2, CO and O3) and meteorological parameters(relative humidity, temperature and solar radiation.)

  • PDF

A Study on the Emission Estimate of Pollutants in Pusan (부산지역에서의 오염물 배출량 산정에 관한 연구)

  • 김유근;이화운;전병일;방종선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.361-367
    • /
    • 1996
  • In order to accurately predict air pollution concentration according to reduction of air pollutant emission, a numerical model is needed. And the total emission amount of air pollutants should be estimated to explain the air pollution phenomena. The characteristics of the emission amount from area, line, and point sources in Pusan were studied by using emission data during one year (1992). The result showed that the annual total emission amount of pollutant is about 299,744 tons in Pusan. The emission consists of 31.8% of $SO_2$, 48.4% of CO, 4.6% of HC, 11.0% of NOx and 4.1% of TSP, as well as 52.1% of line, 24.1% of area and 23.7% of point sources. The result also showed that emission amount becomes larger in winter than that of the others.

  • PDF

The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation (다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사)

  • Joen, Jeong-In;Lee, Hye-Won;Choi, Hyun-Jin;Jeon, Hyung-Jin;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

Case Study of Hazardous Air Pollutant Concentrations in Residential Areas nearby Small and Medium scale Shipbuilding Companies (중소규모 조선소 인근 주거지역의 유해대기오염물질 농도에 대한 사례연구)

  • Chung, Jae-Woo;Lee, Myoung-Eun
    • Journal of Environmental Science International
    • /
    • v.18 no.5
    • /
    • pp.517-525
    • /
    • 2009
  • We measured ambient concentrations of hazardous air pollutants such as volatile organic compounds (VOCs) and aldehydes in residential areas nearby small and medium scale shipbuilding companies. The VOC concentrations were higher during the normal operation periods than vacation at which almost all operations were shutdown. Concentrations of VOCs was higher, as the sampling site was nearer from shipbuilding companies. The major components of VOCs were m,p-xylene, ethylbenzene, o-xylene, toluene, and 1,3,5-trimethylbenzene which had been found as major VOC compounds emitted from painting processes of shipbuilding in the previous studies. The major components of aldehydes analyzed were benzaldehyde, acrolein, formaldehyde, and acetaldehyde. The concentration of aldehydes was highest at the furthest sampling point from shipbuilding companies because the formation of aldehyde compounds could be occurred by the secondary chemical reactions of VOCs. The results of this study shows a proper counterplan need to be established for the reduction of hazardous air pollutants emitted from small and medium scale shipping companies.

Methodology of Application to Air Quality Model to Evaluate the Results of the Enforcement Plan in Seoul Metropolitan Area (수도권 지역의 대기환경관리 시행계획 추진결과 평가를 위한 대기질 모델링 적용 방법)

  • Yoo, Chul;Lee, Dae-Gyun;Lee, Yong-Mi;Lee, Mi-Hyang;Hong, Ji-Hyung;Lee, Seok-Jo
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1647-1661
    • /
    • 2011
  • The Government had devised legislation of Special Act and drew up guidelines for improving air quality in Seoul Metropolitan area. In 2007 local government of Seoul, Incheon and Gyeonggi conducted the results of application policy by reduced air pollutants emission for the first time. Although there was reduction of air pollutant emission in each local government, it was ineffective as expected using air pollution monitoring database. Therefore we worked out a way to prepare modeling input data using the results of enforcement plan. And we simulated surface $NO_2$ and PM10 before and after decrease in air pollutants emission and examine reduction effects of air pollution according to enforcement regulation except other influence, by using MM5-SMOKE-CMAQ system. Each local government calculated the amount of emission reduction under application policy, and we developed to prepare input data so as to apply to SMOKE system using emission reduction of enforcement plan. Distribution factor of emission reduction were classified into detailed source and fuel codes using code mapping method in order to allocate the decreased emission. The code mapping method also included a way to allocate spatial distribution by CAPSS distribution. According to predicted result using the reduction of NOx emission, $NO_2$ concentration was decreased from 19.1 ppb to 18.0 ppb in Seoul. In Gyeonggi and Incheon $NO^2$ concentrations were down to 0.65 ppb and 0.68 ppb after application of enforcement plan. PM10 concentration was reduced from 18.2 ${\mu}g/m^3$ to 17.5 ${\mu}g/m^3$ in Seoul. In Gyeonggi PM10 concentration was down to 0.51 ${\mu}g/m^3$ and in Incheon PM10 concentration was decreased about 0.47 ${\mu}g/m^3$ which was the lower concentration than any other cities.

A Study on Evaluation of IAQ in Dwelling House (주거건축의 IAQ에 관한 연구)

  • 박미진
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.108-112
    • /
    • 1997
  • Recently, the use of Dwelling House has been expanded due to the rapid urbainzation and congestion of population in City. Indoor Air Quality in apartment houses was investigated by measuring pollutants such as $CO_2$ gas, dust concentration. In this study, the mesurements of indoor air environment were performed in Dwelling house in Seoul area to investigate indoor air environment and the relation of air contaminative and the response level. Indoor air contamination and living environment of the occupants have been compared & analyzed with practical investigation of IAQ in Seoul, Korea and Tokyo, Japan.

  • PDF

A Study on the Removal Efficiency of Harmful Pollutants in the Cooking Chamber (조리실내의 유해오염물질 제거율에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.149-156
    • /
    • 2016
  • The purpose of this study is to reduce the contaminants (total volatile organic compounds (TVOCs), fine particle, odor and total airborne bacteria) during cooking process in cooking chamber, and to decrease the health damage in indoor space that has bad work environment. In order to solve the shortcomings of existing air purifiers and remove all kinds of pollutants effectively, this study focused on the development of indoor air purifiers which are made of bar type. Bio-ceramics filter which combines activated carbon and loess. The air cleaners developed with 4 measuring items including TVOCs, particulate matter, complex odor and total airborne bacteria were measured comparing their pre-service test to their post-service test after a period of time. The measured results showed higher removal efficiency of 91.02% as the concentration of TVOCs was reduced from $2,500{\mu}g/m^3$ to $223{\mu}g/m^3$. Second, the particulate matter removal ratio was 97.51% efficient with average concentration of $26.68{\mu}g/m^3$. Third, the odor showed 95.20% reduction as air dilution ratio averaged out at 144. Last, total airborne bacteria was eliminated by over 94% showing the changeable concentration from $787{\sim}814CFU/m^3$ to $47{\sim}40CFU/m^3$. In addition, the removal rate of harmful pollutants is excellent, and it is expected that the environment of the existing poor cooking room will be greatly improved by using the developed air purifier in combination with the ventilation device and the stove hood.

Analysis of Meteorological Characteristics related to Changes in Atmospheric Environment on Jeju Island during 2010-2012 (최근(2010~2012년) 제주지역 대기환경 변화에 관한 기상특성 분석)

  • Song, Sang-Keun;Han, Seung-Bum;Kim, Suk-Woo
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1889-1907
    • /
    • 2014
  • The characteristics of meteorological conditions related to changes in atmospheric environment on Jeju Island were investigated during recent years (2010-2012). This analysis was performed using the hourly observed data of meteorological variables (air temperature, wind speed and direction) and air pollutants ($O_3$, $PM_{10}$, $SO_2$, $NO_2$, and CO). Out of 5 pollutants, $O_3$ and $PM_{10}$ concentrations have frequently exceeded national environmental standards in the study area during the study period, with relatively higher concentrations than the others. The concentrations of $O_3$ and $PM_{10}$ in 2010 and 2011 were somewhat higher than those in 2012, and their highest concentrations were mostly observed in spring followed by fall. Nighttime $O_3$ concentrations (with relatively high concentration levels) were almost similar to its daytime concentrations, due to less $O_3$ titration by very low NO concentrations in the target area and in part to $O_3$ increase resulting from atmospheric transport processes. The transport effect related to the concentration variations of $O_3$ and $PM_{10}$ was also clarified in correlation between these pollutants and meteorological variables, e.g. the high exceedance frequency of concentration criteria with strong wind speed and the high concentrations with the westerly/northwesterly winds (e.g., transport from the polluted regions of China). The overall results of this study suggest that the changes in atmospheric environment in the study area were likely to be caused by the transport effect (horizontal and vertical) due to the meteorological conditions rather than the contribution of local emission sources.

Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology (대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구)

  • Park, Duck Shin;Kwon, Soon Bark;Cho, Young Min;Jang, Seong Ki;Jeon, Jae Sik;Park, Eun Young
    • Particle and aerosol research
    • /
    • v.6 no.1
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.

3-D Numerical Prediction Modeling of Air Pollution in Coastal Urban Region -(I) An Effect Prediction for Deposition Phenomenon affecting on Air Quality (연안도시지역에서 대기오염의 3차원 수치예측모델링 -(I) 침적현상이 대기질에 미치는 영향예측)

  • 원경미;이화운
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.625-638
    • /
    • 1999
  • Air quality modeling for coastal urban region has been composed of a complex system including meteorological, chemical and physical processes and emission characteristics in complex terrain. In this study, we studied about an effect prediction for deposition phenomenon affecting on air quality in Pusan metopolitan metropolitan city. In air quality modeling including ship sources, a situation considered deposition process habe better result than not considered when compared with observed value. Air pollutants emitted into urban air during the daytime nearly removed through urban atmosphere polluted. Also these phenomena correlated concentration variation connent with sea/land breezes and terrain effect. Therefore we conclude that the concentration was low at daytime when deposition flux is high, and deposition effect on industrial complex and Dongrae region is considerable in particular.

  • PDF