• 제목/요약/키워드: Air pollutant

검색결과 826건 처리시간 0.022초

항공기 엔진에 의한 대기오염 (Air Pollution by Airplane Engines)

  • 김대식
    • 기술사
    • /
    • 제32권5호
    • /
    • pp.118-125
    • /
    • 1999
  • Air pollutant emissions from airplane engines are estimated about 2 to 4 % of mobile source of USA and European countries which is not a large portion of current air pollution. But the passengers and airfreights are continuously increasing 5 to 7% annually and potential demands of air transportation services come to present, it could effect air pollutant emissions of USA will increase within 15 years. In case of our country, there has been continuous increase of air transportation service due to considerable economic growth in recent years and increase of air pollutant emissions of major international airports has followed. Rapid increase of air transportation due to launching of Inchon International Airport could effect air pollution dominantly. By this circumstance environmental specialist as well as mass communication raised necessity of air pollutant emission regulation from airplane engines. It is estimated that air pollutant emissions from airplane engines in our country is 2.7% of automobile sources, 10,809 ton, which is the same level as USA and European countries. It is increased by 12,2% compared to air pollutant emissions during 1996 and it will be increased more than a half of current air pollutant emission within 15 years due to our country's economic condition. Therefore implementation of airplane engine emissions regulation as well as test standards and accumulation of technology about characteristics of airplane engine emission and reduction method are needed. And continuous estimation of air pollutant emission from airplane engines and monitoring of increment as well as development of countermeasures by long term are necessary.

  • PDF

실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구 (The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제11권E호
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

Exploiting Neural Network for Temporal Multi-variate Air Quality and Pollutant Prediction

  • Khan, Muneeb A.;Kim, Hyun-chul;Park, Heemin
    • 한국멀티미디어학회논문지
    • /
    • 제25권2호
    • /
    • pp.440-449
    • /
    • 2022
  • In recent years, the air pollution and Air Quality Index (AQI) has been a pivotal point for researchers due to its effect on human health. Various research has been done in predicting the AQI but most of these studies, either lack dense temporal data or cover one or two air pollutant elements. In this paper, a hybrid Convolutional Neural approach integrated with recurrent neural network architecture (CNN-LSTM), is presented to find air pollution inference using a multivariate air pollutant elements dataset. The aim of this research is to design a robust and real-time air pollutant forecasting system by exploiting a neural network. The proposed approach is implemented on a 24-month dataset from Seoul, Republic of Korea. The predicted results are cross-validated with the real dataset and compared with the state-of-the-art techniques to evaluate its robustness and performance. The proposed model outperforms SVM, SVM-Polynomial, ANN, and RF models with 60.17%, 68.99%, 14.6%, and 6.29%, respectively. The model performs SVM and SVM-Polynomial in predicting O3 by 78.04% and 83.79%, respectively. Overall performance of the model is measured in terms of Mean Absolute Error (MAE), Mean Absolute Percentage Error (MAPE) and the Root Mean Square Error (RMSE).

도로환경요인이 도로변 대기오염에 미치는 영향분석 (Effects of Road and Traffic Characteristics on Roadside Air Pollution)

  • 조혜진;최동용
    • 대한교통학회지
    • /
    • 제27권6호
    • /
    • pp.139-146
    • /
    • 2009
  • 대기오염 물질배출량 중 도로이동오염원에 의한 배출량은 다른 오염원에 비해 월등히 높은 편이나 관련연구가 미흡한 실정이다. 본 연구에서는 교통량, 속도 및 기타기상 조건의 실시간 자료와 도로기하구조와 같은 도로특성인자를 반영하여, 대기오염 물질 배출에 도로환경요인이 미치는 영향을 분석하였다. 서울시의 실시간 대기오염 데이터와 교통량, 도로관련 데이터를 수집하여 대기오염 물질별 오염배출량 예측 회귀모형식을 구축하였다. 본 연구에서 얻어진 결과를 요약하면 다음과 같다. 첫째, 교통량이 증가할수록 오염물질의 측정량은 증가하며, 속도가 증가할수록 측정량은 감소한다. 둘째, 풍속, 온도, 습도가 증가할수록 측정량은 감소한다. 셋째, 교차로 형태가 복잡할수록 측정량은 감소한다. 예측모형을 검증하기 위하여 예측치와 실측치 데이터를 비교 분석한 결과 총 7곳의 도로변대기오염 측정망 중 실측치와 예측치가 가장 부합하는 측정망은 청계 4가 측정망인 것으로 나타났다. 본 연구는 실시간 대기오염배출량 데이터와 교통량 데이터, 도로환경 특성데이터를 이용하여 예측모형을 구축하여 현실적인 도로환경요인이 대기질에 미치는 영향을 설명하였다는 데 의의가 있다.

Analysis of High Concentration Diffusion Pattern by Air Pollutions in Port Industry Interfaces

  • Je-Ho Hwang;Sang-Hyung Park;So-Hyun Yun;Si-Hyun Kim
    • Journal of Korea Trade
    • /
    • 제26권3호
    • /
    • pp.117-136
    • /
    • 2022
  • Purpose - Port is vital for international trade accounting for approximately 80% of world cargo transportation in the global trade sector. Air pollutants emitted owing to the related industry interfaces developed around the port spread throughout the dense population region can have harmful effects on the nearby residents. This study aims to analyze high-concentration diffusion pattern by air pollutants, considering the main management periods by air pollutants. Design/methodology - Employing the concentration criteria per main air pollutant, the analyses of concentration change patterns per air pollutant, wind characteristics that directly affected the air pollutant diffusion, distribution types per air pollutant, and high-concentration diffusion patterns by season according to time changes were conducted. Findings - The substances that caused harmful levels of air pollution in the hinterland living zone of the Busan New Port were PM_10, PM_2.5, and NO_2. Furthermore, the intensive management periods were as follows: For PM_10, 24-h (spring), 12:00-16:00 (summer), 12:00-16:00 (summer), 20:00-12:00 (fall), and 24:00-20:00 (winter), and for PM_2.5, 24-h (all four seasons), and for NO_2, 23:00-04:00 (spring), 23:00-08:00 (summer), and 20:00-08:00 (fall), and 23:00-04:00 (winter). Originality/value - Research finding indicates that regular monitoring and countermeasures to reduce air pollution for each air pollutant makes it possible to achieve effective air quality control in the port and hinterland living zones.

오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획 (Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations)

  • 김지영;이승희;김태연
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

중소도시에 위치한 집단 열 공급시설에서 배출되는 대기오염물에 의한 주변 대기질의 영향 조사 및 예측 (The Ivestigation and Estimate of Influence on Air Quality by the Exhaust of Air Pollutant from Facility of the District Heating Located in Small City)

  • 연익준;김광렬
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.1-10
    • /
    • 2003
  • This study was aimed to investigate the influence on the vicinity by air pollutant generated from facility of the district heating located in local small town. We selected the seven areas arround the surroundings of facility of the district heating, compared the air quality evaluated before and after operations of the facility, and estimated the diffusion of air pollutant exhausted from the facility using a ISC model. The result was that the concentration of TSP before and after operations of the facility was 89${\sim}$94${\mu}$g/m$^3$,and 72${\sim}$81${\mu}$g/m$^3$, respectively and the latter showed a decline in concentration. Also, there was no relationship between straight distance from the facility of the district heating and the concentration of TSP. This result was applicable to cases of PM-10 and SO$_2$. We also investigated the influence on the air around the neighbored area by air pollutant produced from facility of the district heating using ISCLT3 model. The adding-concentrations of TSP, SO$_2$,NO$_2$, and CO were 0.0019${\sim}$0.00183${\mu}$g/m$^3$, 0.0029${\sim}$0.5648ppb, 0.2924${\sim}$l.9837ppb,and 0.0087${\sim}$0.0590ppb, respectively. It is predicted that each concentration is added to pollutant exhausted from facility of the district heating and is about 1/100${\sim}$1/180,000 of present air quality. This has a tiny influence on general air quality. According to this analysis, the concentration of air pollutant is less effected to pollutants expected by the facility of the district heating than other pollutants emitted from mobil source or industrial complex, and etc.

격리병실내 급배기구 위치에 따른 오염물 제거효율 비교 (Comparison of pollutant removal efficiency according to the locations of the supply and exhaust)

  • 원안나
    • 도시과학
    • /
    • 제9권2호
    • /
    • pp.13-20
    • /
    • 2020
  • The Recently, several countries have been affected by respiratory diseases, resulting in renewed research interest in their prevention and control. One such example was the 2015 outbreak of Middle East Respiratory Syndrome (MERS) in South Korea and COVID-19. In this study, we performed experiments and simulations based on concentration decay using CO2 as the tracer gas to elucidate the pollutant-removal efficiency for different inlet and exhaust locations and outdoor air-supply ratios. The wall inlet exhibited a higher pollutant-removal efficiency, owing to the upward movement of the air from the lower zone to the upper one. In conclusion, it is recommended that a total air-conditioning plan for isolation rooms be established as well as efficient system operation for pollutant removal and air-flow control to prevent the transmission of infections from the patients to others.

서울.수도권 지역 주요 대기오염물질 배출원 자료 현황 분석 (Analysis of the Present State of Air Pollutant Emission Data for the Greater Seoul Area)

  • 김진영;김영성;김용표
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.813-826
    • /
    • 1999
  • To understand the present status of air pollutant emission data for the greater Seoul area, existing air pollutant emission data were analyzed and compared. For the criteria pollutants, estimation methods of emissions from point, line, and area sources adopted in the previous studies were analyzed and their results were compared. Two sets of VOC emission estimation were also compared and analyzed. There exists a large discrepancy among previous emission data due to the differences in the scope of emission sources and the estimation method including emission factors employed in each estimation. Applications of previous air pollutant emission studies for air quality modeling and related problems were discussed.

  • PDF

공동주택에서 환기장치류 가동특성에 따른 실내공기질 변화특성에 관한 연구 (The Effects to Indoor Air Quality as Ventilation System Operation in Apartment House Using CFD Simulation)

  • 김석근;이정재
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.142-148
    • /
    • 2007
  • The purpose of this study is to suggest the effective ventilation strategies and control methods that can minimize energy cost maintaining acceptable IAQ level in apartment house. The effects of the air-cleaning and heat-recovery ventilation system on IAQ under various operating conditions are investigated based on the experimental and CFD analyzed results. The results can be summarized as follows. (1) When a ventilator is not operated, the concentration of several pollutants may highly show in the house even though environment-friendly building materials are applied. Therefore, a mechanical ventilation system is required to obtain proper ventilation. (2) The pollutant concentration is noticeably deceased under air-cleaning/ventilation mode of air-clinic system, however, pollutant of kitchen is stagnant, because fresh air is not carried into the kitchen. (3) When air-clinic system is only equipped at master bedroom and living room, the system does not effectively deliver fresh air throughout the whole house, and then high pollutant concentration is obtained in each room. In contrast the average pollutant concentration meets the guideline when air-clinic system is installed at each room. (4) The air-cleaning/ventilation mode significantly affects on room ventilation in comparison with ventilation mode only.