• 제목/요약/키워드: Air particulates

검색결과 125건 처리시간 0.028초

병원 수술실에서의 복강경 수술 중 실내공기질 평가 (Evaluation of Indoor Air Quality in a Hospital Operating Room During Laparoscopic Surgery)

  • 최동희;강동화
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제30권3호
    • /
    • pp.67-74
    • /
    • 2024
  • Purpose: The identification and quantification of indoor airborne contaminants, including bio-aerosols, particulates, and gaseous contaminants, are crucial for maintaining acceptable indoor air quality for hospital operating rooms (ORs). Laparoscopic surgery has become widely accepted for various surgical procedures due to its rapid recovery rate and the low risk associated with small incisions compared to conventional open surgery. The objective of this study is to investigate the indoor air quality in hospital ORs and to identify indoor airborne contaminants generated during laparoscopic surgery. Methods: Measurements of an indoor environment, including temperature, humidity and air quality, were performed in an OR before and during a laparoscopic surgery. Indoor airborne contaminants, including volatile organic compounds (VOCs), formaldehyde, carbon monoxide (CO), carbon dioxide (CO2), sulfur dioxide (SO2), nitrogen dioxide (NO2), suspended indoor particles, and airborne bacteria, were measured simultaneously. Results: The study determined that the concentrations of indoor air particles and airborne bacteria increased during the surgery but were within acceptable levels. However, the concentration of CO2, reached a high level of 1,791 ppm due to the CO2 gas required for maintaining the pneumoperitoneum during the surgery. Implications: The results emphasized the use of ventilation and filtration in a laparoscopic surgery room to lower the concentration of filterable and non-filterable contaminants.

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at kwangju Area

  • Son Bu-Soon;Song Mi-Ra;Yang Won-Ho;Park Jong-An
    • 한국환경과학회지
    • /
    • 제15권2호
    • /
    • pp.101-106
    • /
    • 2006
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals that are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCs and particulate matter $(PM_{10})$ during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and $PM_{10}$ were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. The measured mean concentrations of respiratory particulates were $30.5ng/m^3$ in indoor, $30.5ng/m^3$ in outdoor and $44.0ng/m^3$ on personal levels. The personal concentration was found higher than indoor and outdoor concentrations. The heavy metals mean concentrations were shown as indoor (Na>Zn>Cr), outdoor (Cr>Zn>Pb), and personal (Na>Cr>Zn) levels. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor and outdoor sources. Therefore, proper management should be taken to improve the indoor air quality in beauty shops.

경남 김해지역의 동계 대기중 중금속 분포와 특성 (Study on the Distribution and Characteristics of Heavy Metals in Ambient Air of Kimhae, Kyongnam of Wintertime)

  • 정성욱;전병일
    • 한국환경과학회지
    • /
    • 제5권4호
    • /
    • pp.453-462
    • /
    • 1996
  • This study was conducted to evaluate the level of atmospheric heavy metals and the relationship of that concentration with weather conditions. This research monitored the concentration of Total Suspended Particulates (TSP) at every three hours by using High Volume Air Sampler from December 24th, of 1995 to Febuary 20th, 1996 in Kimhae area, which recently became a rapidly growing residential and industrial sitc. The items such as air-temperature, relative humidity, radition, wind speed, and wind direction were monitored by using Atmospheric Weather System at the same time. From the collected TSP, the concentration of heavy metals were analyzed by using the Atomic Absorption Spcetrophotometry. The mean concentration of TSP was 110.4 $\mu\textrm{g}$/$m^3$, and the mean concentration of lead (Pb), copper(Cu), chromium (Cr), manganese (Mn), cadmium (Cd), were 0.837 $\mu\textrm{g}$/$m^3$, 0486 $\mu\textrm{g}$/$m^3$, 0.264$\mu\textrm{g}$/$m^3$). The concentration of Pb and Mn was higher in the moring and that of Cu, Cr and Cd was higher in the afternoon and the evening. Regarding the relationship between the concentration of pollutants and weather condition, the-concentration TSP revealed positive correlation with temperature, humidity, wind speed, but negative correlation with tradition (p<0.01). The concentration of Mn revealed positive correlation with temperature and humidity, but negative correlation with wind speed (p<0.01). And the the concentration of pollutants and weather condition revealed higher correlation within the same time period. In summary, the paralleled mornitoring of air conditions and weather condition should be recommended to. get the correct informations concerning the pollution and to prevent the deterioration of air conditions.

  • PDF

도시 대기중 중금속에 관한 연구 -서울시 신촌지역을 중심으로- (Heavy Metals in Ambient Air at Shinchon Area in Seoul)

  • 정용;장재연;주의조
    • 한국대기환경학회지
    • /
    • 제3권2호
    • /
    • pp.18-26
    • /
    • 1987
  • In order to investigate the character of air pollution by heavy metals and to elucidate the possible sources in Seoul city, this study was performed to measure the concentrations of heavy metals of total suspended particulate and air pollutants such as $SO_2, NO_2, CO, CH_4$, Non-methane hydrocarbon, ozone at the residential-traffic area (shinchon dong) in January and February, 1986. The results are as follows: 1. $SO_2$ and TSP concentration were 135ppb and 167 $\mug/m^3$ in average, respectively. 2. While concentrations of heavy metals such as Fe, Cu, Pb in the ambient air seems gradually decreasing annually, Ni compound has been shown the tendency of increasing. 3. Among heavy metals in TSP analysed, the iron was detected at the highest level, 0.905% and the cadimium was the lowest 0.004% in average, respectively. 4. V, Fe and Zn compounds in air were observed to be highly correlated with their correlation coefficients(r) higher than 0.7. Pb compound was highly correlated to the levels of Zn and Fe, however relatively less correlated to V compound. 5. Among concentrations of heavy metals in the particulates, V and Ni compounds were highly correlated with coefficient(r) of 0.8587; the cause might be imagined by the fact of releasing from combustion of fuel oil. Fe, Pb and Zn compounds were highly correlated $SO_2$ concentration. It might be explained that they were released by combustion of coal. 6. The level of $SO_2$ was highly correlated to most of heavy metals: especially correlation coefficient(r) to Pb compound was 0.9081. Pb compound was also highly correlated to NO, CO and TSP. TSP showed higher correlation to Pb and Cd compounds than to V and Ni compounds. It might be assumed that particulate was mainly produced by combusting coal from space heating and by exhausting gasoline and diesel oil from transportation rather than by burning fuel oil.

  • PDF

공기조화기 장착용 축상유입식 싸이클론의 압력손실에 대한 수치해석 및 실험적 연구 (Numerical and experimental study on the pressure dorp of axial-flow cyclone in the air handling unit)

  • 권순박;박덕신;조영민;김세영;김명준;김호중;김태성
    • 한국입자에어로졸학회지
    • /
    • 제5권2호
    • /
    • pp.37-43
    • /
    • 2009
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator are used in the air handling unit (AHU) of subway stations. However, those systems are prone to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts might malfunction due to the high load of particulates unless the filter medium is periodically replaced. In this study, the use of axial-flow cyclone was proposed for particulate filter unit in the AHU for its low operation and maintenance cost. Novel shape of axial-flow cyclone was designed by using computational fluid dynamics (CFD). The shape of vortex vane was optimized in terms of pressure drop and tangential velocity. In addition, CFD analysis was validated experimentally through the pressure drop measurement of mock-up model. We found that pressure drop and tangential velocity of fluid through the axia-flow cyclone was significantly affected by the rotating degree of vortex vane and the numerical prediction of pressure drop agreed well with experimental measurement.

  • PDF

黃砂現象時 粉塵의 粒度分布와 化學組成에 關한 硏究 (A Study on the Size Distribution and Chemical Component of Suspended Particulate during the Period of Sandy Dust Phenomena)

  • 이민희;한의정;신찬기;한진석
    • 한국대기환경학회지
    • /
    • 제4권2호
    • /
    • pp.57-66
    • /
    • 1988
  • Sandy dust phenomena was observed from April 19 to 23, 1988 in Seoul and suspended particulate was collected by Andersen air sampler during this period. The samples were analyzed for 16 components $(SO_n^{2-}, NO_3^-, Cl^-, PO_4^{3-}, NH_4^+, F^-, Al, Fe, K, Cu, Mn, Na, Pb, Mg, Ca, Cd)$. The conclusions are as follwes: 1. Total suspended particulate concentation during the period of sandy dust phenomena was 489 $\mug/m^3$ (ordinary times: 140-125 $mug/m^3$) 2. The water - soluble ion component concentration of suspended particulate during the period of sandy dust phenomena was few and the metal concentration of that was more than that of ordinary times. 3. The cumulative frequency distribution of suspended particulates in logarithmic diagram did not show similar to normal log distribution during the period of sandy dust phenomena. 4. $SO_4^{2-}, NO_3^-, Cl^-, and PO_4^{3-}$ was onsided to coarse particle, and $NH_4^+$ and F to fine particle in the size distribution of water - soluble ion components during the period of sandy dust phenomena. 5. Metal concentration was high and Al, Fe, Cu, Mn, Na, Mg, and Ca was onsided to coarse particle, and K, Pb, and Cd to fine particle in the size distribution of metal components. 6. During the period of sandy dust phenomena the quantity of respirable particle (< 1 $\mum$) was about 3 times and that of metal components were about 2 - 11 times than that of ordinary times. 7. The concentrations of $NO_3^-, Cl^-, NH_4^+$ at ordinary times were 1.1 - 4 time than that of the period of sandy dust phenomena.

  • PDF

고온 고압 집진을 위한 역세정 유동장의 특성에 관한 연구 (A Study on the Reverse Cleaning Flow Characteristics for High Temperature and High Pressure Filtration)

  • 김장우;정진도;김은권
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.25-31
    • /
    • 2003
  • Ceramic filter has been demonstrated as an attractive system to improve the thermal efficiency and to reduce the effluent pollutants. Removal of particulates from the hot gas stream is very important in air pollution control. In particular, the elimination of the particulate matters discharged from a gas turbine at high temperature can prevent the corrosion inside the IGCC. In this study, a Lab. scale test and numerical simulation were carried out to comprehend the relationship between pulse jet pressure and recovery of pressure drop and to characterize the reverse cleaning flow through a ceramic fil-ter element under high temperature and high pressure. When the pulse-jet pressures were 2, 3 and 4 kg/$ extrm{cm}^2$, the cleaning effect increase of about 10~30% by recovery of pressure drop caused by pulse pressure. Cleaning effect at 45$0^{\circ}C$ was greater than that at 55$0^{\circ}C$ or 650$^{\circ}$ for the same pulse pressure. According to the result of the present simulation, high pressure has been formed in terminal and central regions in our models and temperature distribution caused by pulse air is to be uniform comparatively on inner surface of filter.

황사의 사례분석과 한반도 유입량 (On the occurrence of yellow sand and atmospheric loadings)

  • 정용승;윤마병
    • 한국대기환경학회지
    • /
    • 제10권4호
    • /
    • pp.233-244
    • /
    • 1994
  • The phenomenon of yellow sand (dust clouds) occurred in Korea during the spring of 1993 and 1994 is studied in detail. In total 6 cases including 15 days of yellow sand were observed in 1993 and the annual number of these events was found to increased. Examinations in this study include meteorological charts satellite imagery, pilot reports (PIREP) of Korea Air Force, and air concentrations of total suspended particulates(TSP). We present on estimation of total atmospheric loadings based on the observation and theory. According to the PIREP, in general the dust clouds travelled in the lower troposphere up to the level 5km. The visibility within the clouds was in the range of 3-8km The area covered by yellow sand in an event exceeded 0.4 M $\textrm{km}^2$ . According to trajectory analyses, dust clouds invaded Korea in April and May 1993 were landed in the sink area after 2~4 days travelling for 2,000~3,000km from a source region. Estimates of total atmospheric loadings of a dust cloud for April 23~24 in 1993 were 1.5 M ton. In addition, 7 dust storms were also reported in synoptic observations in NW China and Mongolia during the spring in 1994. The yellow sand was not reported with meteorological observations in Korea, however pilots reported significant dust clouds over the Yellow Sea on 8 and 13 April and 20 May 1994.

  • PDF

지하철 구내의 대기 중 $SO_2$, TSP 농도와 대기 허용기준에 관한 연구 (A Study on Airborne Concentrations of $SO_2$, TSP and Air Quality Standards of a Subway Stations)

  • 김성천
    • 한국환경보건학회지
    • /
    • 제19권1호
    • /
    • pp.37-43
    • /
    • 1993
  • The airborne concentrations of Sulfur Dioxide and Total Suspended Particulates were investigated in 4 subway lines in Seoul at early summer, 1990 and early summer, 1991. The results of the study were as follows: 1. The airborne concentrations of SO$_2$ and TSP were 0.022 ppm, 445.7 $\mu$g/m$^3$ respectively. And percents of over annual air quality standard of WHO was that SO$_2$ and TSP were 41.7%, 100% respectively. 2. Airborne SO$_2$ concentrations by subway lines were that line 1 was 0.025 ppm, line 2 was 0.023 ppm, line 3 was 0.020 ppm, and line 4 was 0.017 ppm. And TSP concentrations by subway lines were that line 2 was 533.8 $\mu$g/m$^3$, line 1 was 516.5 $\mu$g/m$^3$, line 4 was 371.6 $\mu$g/m$^3$, and line 3 was 369.3 $\mu$g/m$^3$ 3. Annual variation of concentration of TSP was not significant statistically (t=0.327), and that of SO$_2$, in 1990 was slightly higher than that in 1991 (t=1.433, p<0.1). 4. Coefficients of correlation between TSP and SO$_2$ by years were that early summer, 1990 was r=0.277 (p>0.1), and early summer, 1991 was r=0.32 (p>0.1).

  • PDF

Effects of Driving Conditions on Diesel Exhaust Particulates

  • Lim, Jae-Hyun;Lim, Cheol-Soo;Kim, Jong-Choon;Seo, Choong-Youl;Lim, Yun-Sung;Ryu, Joung-Ho;Jung, Sung-Woon;Yu, Liya E.;Kostetski, Yu. Yu.
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2007년도 추계학술대회 논문집
    • /
    • pp.61-62
    • /
    • 2007
  • See Full Text

  • PDF