• 제목/요약/키워드: Air particles

검색결과 1,540건 처리시간 0.038초

Particle Size Distribution of Heavy Metals in the Urban Air of Seoul, Korea

  • Sohn, Dong-Hun;Heo, Moon-Young;Kang, Choon-Won
    • Archives of Pharmacal Research
    • /
    • 제12권3호
    • /
    • pp.214-218
    • /
    • 1989
  • Atmospheric particulate matters (A. P. M. ) were collected on quartz-fiber filters from March 1985 to May 1986, using the Andersen high-volume air sampler and contents of six heavy metals (Fe, Mn, Cu, Zn, Pb Ni) in the A. P. M. were determined by atomic absorption spectrophotometry. These heavy metals were divided into the three groups with respect to their particle size distribution. Fe and Mn were mainly associated with coarse particles (diameter > 2.0 $\mu$m), but Pb and Ni were related fine particles (diameter < 2.0 $\mu$m). Cu and Zn had mized size distributions in both of them. In the seasonal variation of heavy metals, the contents of Fe and Mn in spring and Ni and Pb in winter were higher than any other season. There were high mutual correlation between Fe and Mn coarse particles, and between Pb and Ni in fine particles.

  • PDF

필터여재의 성능평가 (Performance Test of Air Filter Media)

  • 안강호;배귀남
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.417-426
    • /
    • 1994
  • Filter media performance was evaluated using monodisperse NaCl particles with Differential Mobility Analyzer and Ultrafine Condensation Particle Counter. Low or medium performance filters show that the most penetrating particles size(MPPS) is around $0.3{\mu}m$ in diameter and is shifted to smaller sizes as the filter face velocity increases. However, HEPA and ULPA filters show MPPS is around $0.15{\mu}m$ in diameter and is also shifted to $0.1{\mu}m$ in diameter as the face velocity increases. In case of electret filter, the MPPS is found around $0.04{\mu}m$ region for Boltzmann charge equilibrium particles. There is a tendency of strong collection efficiency decrease for large particles as the face velocity increases on the contrary to the other filters. One of the medium performance filter efficiency was compared with filtration theory and the good agreetment was found in the experimental range.

  • PDF

도심 내 버스정류장 부근의 에어로졸 입자 크기 및 형상 관찰 (A Study on the Shapes of Aerosol Particles at a Bus Stop in the Eastern Part of Seoul)

  • 정상빈;허기준;신창훈;조원경;이병욱
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.109-114
    • /
    • 2016
  • People in metropolitan cities can be exposed to particulate air pollutants at public transportation systems such as bus stops. In this study, we sampled aerosol particles with an impactor at a bus stop. We analyzed the shapes of these particles with an optical microscope. It was estimated that fibers, silicons, byproducts of combustion, and pollens existed in the air environments at the bus stop with analysis of shapes of sampled particles.

단열 페인트 첨가제로써 중공형 실리카 나노입자의 크기에 따른 효과 (Size Effect of Hollow Silica Nanoparticles as Paint Additives for Thermal Insulation)

  • 김지수;김영훈
    • 청정기술
    • /
    • 제28권1호
    • /
    • pp.18-23
    • /
    • 2022
  • 에너지 절약을 위한 연구 중 단열 기술 분야에서는 공기의 낮은 열전도도를 활용한 연구가 이뤄지고 있으며 널리 상용화 되고 있다. 본 연구에서는 입자 내부에 공기층을 갖는 중공형(hollow) 형태의 실리카 나노 입자를 제조하여 공기층 크기가 단열 성능에 미치는 영향에 대해 고찰하였다. Polystyrene 주형법을 이용하여 졸-겔공정을 통해 속이 빈 중공형 실리카 나노 입자(Hollow silica nanoparticles)를 제조하였고, 입자를 5 wt %로 도료에 첨가한 후 열전달 실험을 통해 단열 성능을 확인하였다. 기존 페인트에 입자를 혼합하여 약 15 %이상의 단열효율을 나타냈으며, 내부 공기층의 크기가 큰 입자가 작은 입자에 비해 5% 높은 단열 성능을 나타냈다. 이번 연구를 통해 내부 크기에 따른 단열효과의 차이를 보여줌으로써, 중공형 형태의 입자를 첨가제나 도료 제조에 사용하는 경우 단열효과를 높이기 위해 매질 내에서 입자가 공기층을 최대로 이룰 수 있도록 입자의 크기를 고려해야함을 제시한다.

배리어 유전체 방전을 이용한 전기 집진부에서의 나노 입자 집진 효율 (Collection Efficiency of Nano Particles by Electrostatic Precipitator using Dielectric Barrier Discharge)

  • 강석훈;지준호;변정훈;황정호
    • 대한기계학회논문집B
    • /
    • 제27권11호
    • /
    • pp.1542-1547
    • /
    • 2003
  • Although dielectric barrier discharge (DBD) in air has been applied to a wider range of aftertreatment processes for HAPs (Hazardous Air Pollutants), due to its high electron density and energy, its potential use as precharging dust particles is not well known. In this work, we measured size distributions of bimodal aerosol particles and estimated collection efficiency of the particles by an electrostatic precipitator (ESP) using DBD as particle charger. To examine the particle collection with DBD charger, nano size particles of NaCl(20∼100nm) and DOS (50∼500nm) were generated by a tube furnace and an atomizer, respectively. For experimental conditions of 60㎐, 11㎸ and 60 lpm, the particle collection efficiency for the hybrid system was over 85%, based on the number of particles captured.

전기 수력학적 방법을 이용한 미세 입자의 하전 특성에 관한연구 (Study on the Fine Particle Charging Characteristics with the Electrohydrodynamic Atomization)

  • 안진홍;김광영;윤진욱;안강호
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.289-294
    • /
    • 2001
  • A well defined electro-spraying and electro-static precipitator(ESP) experiment is carried out to investigate the charging characteristics of the submicron particles and the monodisperse particles. The basic idea is that the highly charged electro-sprayed droplets will be produced into the gas when the Coulombic repulsive force on the surface is higher than the surface tension of the spraying liquid. During this process many highly charged smaller droplets or ions, if the droplets are completely dried out, will be produced in the space. These charged species will be attached ion the particles and then eventually charge the particles. These charged particles will be easily collected with ESP. The experimental results show that the atomizer generated particles with geometric mean diameter (GMD) of 62nm are charged more than 90% even at the mean face velocity of 2.5m/s at the charging zone.

  • PDF

DBD(Dielectric Barrier Discharge)에 의해 하전된 나노입자의 양극성 대전량 분포 (Bipolar Charge Distribution of Nano Particles Passing through the Dielectric Barrier Discharge Reactor)

  • 지준호;강석훈;변정훈;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1684-1689
    • /
    • 2003
  • Dielectric Barrier Discharges (DBD) in oxygen and air are well established for the production of large quantities of ozone and are more recently being applied to a wider range of after treatment processes for HAPs(Hazardous Air Pollutants). The potential use as a charger for particle collection are not well known. In this work, we measured charge distribution of nanometer or submicron sized particles passing through the dielectric barrier discharge reactor. The bipolar charge characteristics of particles passing DBD reactor were investigated. Fluorometric method using uranine particles and a fluorometer was employed to examine the bipolar charging characteristics of the charged particles by DBD reactor. Finally, the charge distributions of particles were determined from the electrical mobility classification using DMA.

  • PDF

배리어 유전체 방전을 이용한 전기 집진부에서의 나노 입자 집진 효율 (Collection Efficiency of Nano Particles by Electrostatic Precipitator using Dielectric Barrier Discharge)

  • 강석훈;변정훈;지준호;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1435-1440
    • /
    • 2003
  • Although Dielectric Barrier Discharge (DBD) in air has been applied to a wider range of aftertreatment processes for HAPs(Hazardous Air Pollutants), due to its high electron density and energy, its potential use as precharging dust particles is not well known. In this work, we measured size distributions of bimodal aerosol particles and estimated collection efficiency of the particles by electrostatic precipitator(ESP) using DBD as particle charger. To examine the particle collection with DBD charger, nano size particles of NaCl($20{\sim}100$ nm) and DOS($50{\sim}800$ nm) were generated by tube furnace and atomizer, respectively. For experimental conditions of 60 Hz, 11 kV, and 60 lpm, the particle collection efficiency for the hybrid system comprising DBD charger and ESP was over 85 %, based on the number of particles captured.

  • PDF

굵은골재의 편장석 함유량이 콘크리트의 성능에 미치는 영향 (Effect of Flat and Elongated Particles in Coarse Aggregates on Properties of Concrete)

  • 원종필;조용진;박광수;신수균
    • 한국농공학회논문집
    • /
    • 제46권2호
    • /
    • pp.49-57
    • /
    • 2004
  • Generally, the properties of aggregate greatly affect the physical and mechanical properties of concrete. Flat and elongated particles in coarse aggregates, for some construction uses, may interfere with consolidation and be difficult to place. In this study, an experiment to evaluate properties of flat and elongated particles as coarse aggregate in concrete was conducted. The experiments include slump test, air content test and compressive strength test. The test result of slump and change of slump was rapidly decreased by percentage of flat and elongated particles. But it had not a trend by increasing percentage of flat and elongated particles. Compressive strength of hardened concrete does not make any differences in comparison.

MOFIA에 의한 두개 입자/기포간 상호작용에 관한 연구 (Characterization of Interaction between Two Particles/Bubbles Flow with Moving Object Flow Image Analyzer System)

  • 최해만;문자수명;송정강일
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.110-116
    • /
    • 2005
  • This paper deals with interaction between two bubbles or particles and flow around them, visualized by a moving object flow image analyzer(MOFIA) consisting of a three-dimensional (3D) moving object image analyzer(MOIA) and two-dimensional particle image velocimetry(PIV). The experiments were carried out for rising bubbles or particles of various densities, sizes, and/or shapes in stagnant water in a vertical pipe. In the MOFIA employed, 3D-MOIA was used to measure particles or bubbles motion and PIV was used to measure fluid flow, The experimental results showed that the interaction was characterized by the shape, size and density of two particles or bubbles.