• Title/Summary/Keyword: Air hearing

Search Result 79, Processing Time 0.029 seconds

Association between hearing loss and high-sensitivity C-reactive protein: the Kangbuk Samsung Cohort Study

  • Jihoon Kim;Yesung Lee;Eunhye Seo;Daehoon Kim;Jaehong Lee;Youshik Jeong;Seonghyun Kwon;Jinsook Jeong;Woncheol Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.38.1-38.10
    • /
    • 2023
  • Background: Hearing loss (HL) is linked to an elevated risk of cardiovascular diseases (CVDs). The pathogeneses of HL and CVD commonly involve inflammatory responses. Previous studies investigated elevated levels of inflammatory biomarkers in subjects with HL, however, their findings did not demonstrate statistical significance. In our cross-sectional and longitudinal study, we investigated the correlation between HL and increased high-sensitivity C-reactive protein (hsCRP) levels to determine how HL is associated with CVDs. Methods: We conducted a cross-sectional study with workers aged over 18 years who underwent health check-ups at our institution between 2012 and 2018 (n = 566,507), followed by conducting a longitudinal study of workers aged > 18 who underwent health checkups at least twice at our institution between 2012 and 2018 (n = 173,794). The definition of HL was as an average threshold of ≥ 20 dB in pure-tone air conduction at 0.5, 1.0, and 2.0 kHz in both ears. The incidence of increased hsCRP levels throughout the follow-up period was defined as a level exceeding 3 mg/L. Logistic regression and generalized estimating equations were performed to estimate the risk of increased hsCRP levels according to the occurrence of HL in groups stratified by age. Results: In the cross-sectional study, the multivariate-adjusted odds ratio (OR) was 1.17 (95% confidence interval [CI]: 1.02-1.34); the OR was 0.99 (95% CI: 0.80-1.22) in those under 40 and 1.28 (1.08-1.53) in those over 40. In the longitudinal study, the multivariable-adjusted OR was 1.05 (95% CI: 0.92-1.19); the OR was 1.10 (95% CI: 0.90-1.35) in those under 40 and 1.20 (1.01-1.43) in those over 40. Conclusions: This cross-sectional and longitudinal study identified an association between HL and increased hsCRP levels in workers aged over 40 years.

The Clinical Considerations of Serous Otitis Media and Ventilation Tube (삼출성중이염과 중이내 통기관 유치술의 임상적 고찰)

  • 김영명;박인용;장태영;심형보
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.14.2-15
    • /
    • 1982
  • Serous otitis media (SOM) is one of the most common otologic diseases which was first discribed by Politzer in 1869. Currentely, among many methods introduced to treat SOM, ventilation tube insertion is considered to be the most popular and standard method being used. However due to complication of it, there remains many disputable various problems. In order to review the clinical aspect of SOM and search for the effects and safety of ventilation tube, we studied 97 SOM patients, who had performed V-tube from Jan. 1981 to Feb. 1982 at ENT dept. of Severance Hospital. Analizing the clinical symptoms, age distribution, associated disease, otoscopic findings of ear drum, degree of hearing loss, hearing gain after insertion of V-tube and complications, following results were obtained. 1) As a subjective symptom, among 29 cases all patients had hearing loss, 19 cases (65.6%) had tinnitus, 12 cases (44.4%) had autophony and 10 cases (34.5%) of the patients had sensation of ear fullness. 2) In age distribution, 6 to 10 year old group was most numerous up to 42 cases (43.3%) and 20 years and over was 23 cases (23.5%) 3) In adult group SOM tend to be involved unilaterally whereas young child group had tendency involving bilaterally. 4) 49 cases (50.05%) were associated with tonsillitis and adenoid vegetation, 15 cases (15.5%) were associated with sinusitis, 4 cases (4.1%) had nasal allergy. 5) In preoperative otoscopic findings, 62 ears (47.7%) had retraction, 37 ears (23.6%) had bulging, 34 ears (21.7%) had color change, and 29 ears (19.7%) had no significant findings. 6) In characteristics of middle ear fluid, child group was tend to have mucinous content (84.2%) while adult group had serous content (62.5%). 7) Average preoperative air-bone gap of pure tone was 25.3 dB. 8) 24 ears (72.7%) had over 10 dB of postoperative hearing gain and average hearing gain was 17.2 dB. 9) There were 44 ears (28.1%) of complications. Among them 37 ears (23.6%) had infection, 3 ears had atelectasis, 2 ears had granulation tissue, 2 ears had permanent perforations. 10) Among 37 ears suffered from post-op. infection, 19 ears (51.4%) had initial infection just after insertion of ventilation tube, 18 ears (48.6%) were infected during the course of post-ventilation tube. Of 37 infected ears, 26 ears (70.3%) responded to conservative care, while 11 ears (29.7%) was cured after removal of ventilation tube.

  • PDF

The Korea's indiscretion in maritime-terrorism and the counter plan (한국 해양테러의 실태 및 대응방안)

  • Park, Jun-seok;Park, Yu-Deuk;Kim, Gi-sang
    • Journal of the Society of Disaster Information
    • /
    • v.3 no.2
    • /
    • pp.79-93
    • /
    • 2007
  • With international urgence of terror situation, many methods of terror techniques and skills are appearing and more intense and threatening terror is braking out not only in the air(plane), but also in the sea(ship). Korea is surrounded by 3 sides of sea and is a proud maritime nation that should advance to foreign country through the sea because South Korea and North Korea are confronting. Korea depend on the maritime transportation, 99.7% of exporting, importing material resources. Therefore, acquisition of the marine safety has the great affect on national security and economical life. On the high tension of situation about threat and possibility of maritime terroism, the potential ways of the improvement policy for counter-tactics against big maritime terror are the following. First, we should construct clear and well-organized network for accurate information about maritime terrorism Second, we should have the information of all domestic, foreign passenger's ships Third, national important facilities such as atomic energy plant, thermo-electric power plant, shipyard need policies to manage all emergency situation Fourth, government authorities should improve tactic abilitities by competing with support and budget inside of nation as well as outside of nation. To develop big maritime terror of our country, we will have to hold cooperative training & tactics contest of big maritime terror by cooperating educational industry organization with similar institute, improve the ability of members of big terror and acquire tactics information by excavating and exchanging a new technique through tactics seminar and public hearing.

  • PDF

A Study on Actual Condition of the Noise in a Factory (일 제조업체의 작업장 소음실태에 관한 연구)

  • Shin Soo Ok
    • Journal of Korean Public Health Nursing
    • /
    • v.9 no.2
    • /
    • pp.43-51
    • /
    • 1995
  • Many poeple has been engaged in industry is aware of the dangers from exposure to high intensity nose levels. The exposure to high intensity noise is encountered in a large number of situations. Laws governing the safety and health of employed people being to create a suitable working environment and eliminate unsafety practices and processes. Work areas should be designed and laid out so that they are satisfactory both from the environmental and safety points of view. In this connection safety also implies that noise is kept at a level which is not likety to cause hearing damage. This study was performed to measure the noise of press and assembly process in an automobile factory. and suggested the method of noise control. Consequently the effect ways of reducing level in working environment are as follows; 1. Changes to machines which would reduce noise generation. 2. Alteration of equipment to avoid impact in machinery and handing materials. 3. Enclosure of noisy machines or machine parts. 4. Mounting of attenuators on gas and air outlets as well as ventilation ducts. 5. Erection of sound absorbing screens. linings. and baffles in work areas. 6. The personal ear protectors can be chosen to protect the workers.

  • PDF

Analysis for the Reduction of Tonal Noise in the Centrifugal Fan for the Ship Considering Structural and Electromagnetic Characteristics of the Fan-Motor System (팬-모터의 구조 및 전자기적 특성을 고려한 선박용 원심 팬의 순음 저감 분석)

  • Han, Hyung-Suk;Jang, Cheon-Ik;Lee, Sang-Gu;Koo, Ja-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.359-367
    • /
    • 2008
  • The maximum sound pressure level in a ship is restricted by the international standard such as MIL-Std. 740-1 in order to protect hearing ability for the crew on a ship. Especially, the noise of a fan system is restricted by the maximum level of the sound power according to the military specification such as MIL-F-1900A. In this paper, the reduction of tonal noise for the fan-motor system on a ship is described related to the electrical as well as structural problems. For the electrical problems, the difference of the magnetic flux caused by the variation of the air-gap is described related to the bad concentricity of the motor housing and the shaft-bearing. And for the structural problem, the resonance of the fan motor system is described.

  • PDF

A Study on subtitle synchronization calibration to enhance hearing-impaired persons' viewing convenience of e-sports contents or game streamer contents (청각장애인의 이스포츠 중계방송 및 게임 스트리머 콘텐츠 시청 편의성 증대를 위한 자막 동기화 보정 연구)

  • Shin, Dong-Hwan;Kim, Jeong-Soo;Kim, Chang-Won
    • Journal of Korea Game Society
    • /
    • v.19 no.1
    • /
    • pp.73-84
    • /
    • 2019
  • This study is intended to suggest ways to improve the quality of the service of subtitles provided for the convenience of viewing for deaf people on e-sports broadcast content and game streamer content. Generally, subtitling files of broadcast content are manually written on air by stenographers, so a delay of 3 to 5 seconds is inevitable compared to the original content. Therefore, the present study proposed the formation of an automatic synchronization calibration system using speech recognition technology. In addition, a content application experiment using this system was conducted, and the final result confirmed that the time of synchronization error of subtitling data could be reduced to less than 1 second.

Is Ossiculoplasty Necessary in Canal Wall Down Mastoidectomy? Comparison of Clinical Outcomes Between Type 0 Tympanoplasty and Ossiculoplasty

  • Suh, Michelle J.;Park, Jin-A;Yi, Hee Jun;Song, Chan Il
    • Journal of Audiology & Otology
    • /
    • v.25 no.2
    • /
    • pp.104-109
    • /
    • 2021
  • Background and Objectives: To assess whether the audiological and clinical outcomes of type 0 tympanoplasty (T0) performed using cartilage were comparable with those of ossiculoplasty in patients who underwent canal wall down mastoidectomy (CWDM). Subjects and Methods: This study included patients who had chronic otitis media with cholesteatoma and underwent CWDM with ossiculoplasty involving partial ossicular replacement prosthesis (PORP), total ossicular replacement prosthesis (TORP), or T0. Anatomical success rates and hearing outcomes were analyzed. Results: Seventy-two patients were included in this study; 29 of them underwent CWDM with T0, 27 underwent CWDM with PORP, while 16 underwent CWDM with TORP. The difference in mean improvement in the air-bone gap (ABG) between the groups was not significant. The differences in the rates of ABG closure to ≤10 dB HL (p=0.030) and ≤20 dB HL (p=0.029) were significant. There were significant differences in improvements in the ABG at 3 kHz among the PORP, TORP, and T0 groups. Conclusions: The audiological outcomes of CWDM with ossiculoplasty seemed to be better than those of CWDM with T0 with no significant difference in the incidence of complications following ossiculoplasty and T0.

Is Ossiculoplasty Necessary in Canal Wall Down Mastoidectomy? Comparison of Clinical Outcomes Between Type 0 Tympanoplasty and Ossiculoplasty

  • Suh, Michelle J.;Park, Jin-A;Yi, Hee Jun;Song, Chan Il
    • Korean Journal of Audiology
    • /
    • v.25 no.2
    • /
    • pp.104-109
    • /
    • 2021
  • Background and Objectives: To assess whether the audiological and clinical outcomes of type 0 tympanoplasty (T0) performed using cartilage were comparable with those of ossiculoplasty in patients who underwent canal wall down mastoidectomy (CWDM). Subjects and Methods: This study included patients who had chronic otitis media with cholesteatoma and underwent CWDM with ossiculoplasty involving partial ossicular replacement prosthesis (PORP), total ossicular replacement prosthesis (TORP), or T0. Anatomical success rates and hearing outcomes were analyzed. Results: Seventy-two patients were included in this study; 29 of them underwent CWDM with T0, 27 underwent CWDM with PORP, while 16 underwent CWDM with TORP. The difference in mean improvement in the air-bone gap (ABG) between the groups was not significant. The differences in the rates of ABG closure to ≤10 dB HL (p=0.030) and ≤20 dB HL (p=0.029) were significant. There were significant differences in improvements in the ABG at 3 kHz among the PORP, TORP, and T0 groups. Conclusions: The audiological outcomes of CWDM with ossiculoplasty seemed to be better than those of CWDM with T0 with no significant difference in the incidence of complications following ossiculoplasty and T0.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Journal of Audiology & Otology
    • /
    • v.23 no.3
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Korean Journal of Audiology
    • /
    • v.23 no.3
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.