• Title/Summary/Keyword: Air hearing

Search Result 79, Processing Time 0.026 seconds

Propose Tonal Noise Evaluation Method for Air-conditioner based on Customer's Sensory Evaluation (소비자 감성 평가에 의한 에어컨 Tonal Noise 평가 방법 제안)

  • Lee, Jin-Kyung;Lee, Jea-Won;Joo, Jae-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.154-157
    • /
    • 2005
  • Generally, noise from a indoor air conditioner has been measured by overall sound pressure level, dB. Customers evaluation, however, of the noise from an air conditioners should not be depend on the only overall level but also the sensory feeling. Moreover, in this sensory evaluation, irregular, time-varying and uneven sounds which are difficult to describe itself by overall level are more affectable. Unfortunately however the formal evaluation method for this kinds of noise is not determined yet. In this research, the evaluation method for tonal noise, which is one of the unmeasurable sounds by overall level, is proposed to evaluate its acceptability based on the consumer's sense of hearing. To consider the consumer's sense, several times of Jury evaluation are carried out. The proposed approach could be applied to the other sound, which acoustical characteristics are similar to the tonal noise .

  • PDF

Motivational methods to increase in-field use of personal protective equipment (산업현장에서의 재해예방용 안전기구사용증대를 위한 방법)

  • 박민용
    • Proceedings of the ESK Conference
    • /
    • 1993.10a
    • /
    • pp.15-19
    • /
    • 1993
  • Numerous motivational methodologies were analyzed with respect to improvement of the use of personal protective equipment (PPE) in the industrial field. Common industrial protective devices under consideration included hearing protection devices, respiratory protection devices, eye and face protection devices, etc. It was found that several of such methods could readily be implemented in the real world to protect workers from hazardous industrial sterssors, such as intense noises, toxic air contaminants, and other dangerous industrial objects (e,g., chemicals). Current research issues and recommendations for future research are addressed.

  • PDF

Effects of Hearing Protection Methods and Noise Directions on Bone-Conduction Sensitivity (청력보호구 종류와 소음 방향에 따른 골전도 민감도의 영향)

  • Han, Woojae;Yu, Jyaehyoung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.423-429
    • /
    • 2013
  • The present study aimed to find the most sensitive placement of the skull to perceive speech through the bone vibrator in various protection methods while being exposed to noise. Twenty young normal-hearing adults (10 male and 10 female) participated in the study. As stimulus, Korean spondee words were presented via one of five skull locations (i.e., jaw angle, condyle, temple, mastoid, and vertex), while the participants wore one of four protection methods (i.e., ear form, ear plug, ear muff, and ear form and muff together) against white noise in one of four noise directions (i.e., 0, 90, 180, 270 degrees). The results showed: 1) there was a significant difference among the five skull locations with condyle being the most sensitive placement; 2) there was a significant difference among the four protection methods, with the ear form plus ear muff condition (or dual protection) providing the lowest threshold; 3) when exposed to noise from 90 degrees, the significantly lowest threshold was found; 4) there was no significant difference in results by gender. The pattern of results suggests that the communicative condition via the condyle bone conduction and the dual protection of the air conduction under any noise direction might be ideal for preventing noise-induced hearing loss, although further studies should be undertaken in this area.

The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress (군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향)

  • Han, Sang-Hwan;Cho, Soo-Hun;Koh, Kyung-Shim;Kwon, Ho-Jang;Ha, Mi-Na;Ju, Yeong-Su;Shin, Myung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF

Microscopic versus Endoscopic Inlay Butterfly Cartilage Tympanoplasty

  • Lee, Se A;Kang, Hyun Tag;Lee, Yun Ji;Kim, Bo Gyung;Lee, Jong Dae
    • Journal of Audiology & Otology
    • /
    • v.23 no.3
    • /
    • pp.140-144
    • /
    • 2019
  • Background and Objectives: Inlay butterfly cartilage tympanoplasty makes the graft easy, and reduces operating time. The present study aimed to investigate the outcomes of microscopic versus endoscopic inlay butterfly cartilage tympanoplasty. Subjects and Methods: In this retrospective study, the outcomes of 63 patients who underwent inlay butterfly cartilage tympanoplasty with small to medium chronic tympanic membrane perforation were evaluated. Twenty-four patients underwent conventional microscopic tympanoplasty and 39 underwent endoscopic tympanoplasty. The outcomes were analyzed in terms of the hearing gain and graft success rate. Results: The surgical success rate was 95.8% in the patients who underwent conventional microscopic tympanoplasty and 92.3% in those who underwent endoscopic tympanoplasty. In both groups of patients, the postoperative air-bone gap (ABG) was significantly lower than the preoperative ABG. There were no significant differences between the preoperative and postoperative ABG values in either group. Conclusions: Endoscopic inlay tympanoplasty using the butterfly cartilage technique appears to be an effective alternative to microscopic tympanoplasty and results in excellent hearing.

Microscopic versus Endoscopic Inlay Butterfly Cartilage Tympanoplasty

  • Lee, Se A;Kang, Hyun Tag;Lee, Yun Ji;Kim, Bo Gyung;Lee, Jong Dae
    • Korean Journal of Audiology
    • /
    • v.23 no.3
    • /
    • pp.140-144
    • /
    • 2019
  • Background and Objectives: Inlay butterfly cartilage tympanoplasty makes the graft easy, and reduces operating time. The present study aimed to investigate the outcomes of microscopic versus endoscopic inlay butterfly cartilage tympanoplasty. Subjects and Methods: In this retrospective study, the outcomes of 63 patients who underwent inlay butterfly cartilage tympanoplasty with small to medium chronic tympanic membrane perforation were evaluated. Twenty-four patients underwent conventional microscopic tympanoplasty and 39 underwent endoscopic tympanoplasty. The outcomes were analyzed in terms of the hearing gain and graft success rate. Results: The surgical success rate was 95.8% in the patients who underwent conventional microscopic tympanoplasty and 92.3% in those who underwent endoscopic tympanoplasty. In both groups of patients, the postoperative air-bone gap (ABG) was significantly lower than the preoperative ABG. There were no significant differences between the preoperative and postoperative ABG values in either group. Conclusions: Endoscopic inlay tympanoplasty using the butterfly cartilage technique appears to be an effective alternative to microscopic tympanoplasty and results in excellent hearing.

Load/unload Dynamics of Slider on Ramp for Various Ramp Shapes (램프 형상에 대한 램프 상의 로드/언로드 동특성 해석)

  • Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil;Lee, Yong-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1248-1254
    • /
    • 2005
  • L/UL(Load/unload) mechanism has been widely used in SFF(Small form factor) HDD because L/UL technology has many advantages such as an increase of areal density, reduction of power consumption and improvement of shock resistance. In this system, the most important design goal is no slider-disk contact and fast air-hearing breaking during L/UL process. To do so, we should consider many design parameters related to L/UL system. The ramp shape is the most dominant component among parameters which dramatically affect the L/UL performance. This paper makes an advanced ramp model using ANSYS/LS-DYNA. Through this FE model, this paper investigates the effect of initial ramp slope and location of air-bearing breaking. From the experiment for three different ramps, we also verify that experimental results agree with simulation results. We conclude that the ramp design should have small ramp slope at the moment which a suspension tap contacts with ramp and large ramp slope after air-bearing breaking in order to improve L/UL Performance.

Experimental Analysis Using Taguchi Method on the Resonator in the Rotary Compressor for Air Conditioner (다구찌 법을 이용한 에어컨용 회전압축기 공명기에 관한 실험적 연구)

  • 이병찬;김진동
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.1
    • /
    • pp.3-9
    • /
    • 2004
  • This paper introduces the experimental analysis of the resonator in the rolling piston type compressor for air conditioner. The resonator located between cylinder and hearing is a major factor in the noise reduction of the rotary compressor. Several shapes for the resonator which can be built in the space limitations are derived. Then optimal resonator type for the noise reduction is determined by noise tests. 6 design parameters of the type are found and optimal level for each design factor is deduced from Taguchi method.

Risk Perception Associated with Noise Exposure on Pilots & Ground-crews in the Korean Air Force (공군 작업자들의 소음 폭로와 관련된 위험인지)

  • 강윤성;박상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.610-615
    • /
    • 2002
  • This study is to evaluate the risk perception of noise of the ground-crews in the Korean airbases who exposed to noise of jet plane. 1148 ground-crews and 231 pilots of 2 airbases participated in this study. The questionnaires of risk perception with visual analogue scale were completed by the participants. For comparison, the perception of other risks such as beef contaminated with dioxin, AIDS, lung cancer, otitis media, shigellosis, driving, drinking, and smoking were also included in the questionnaire of risk perception. The results of this study suggested the necessity of risk communication about noise and activation of effective hearing conservation program in the Korean air-force.

  • PDF

Influence of stress and pure tone audiometry on noise-exposed dental laboratory technicians by dental instrument (치과기공 소음 노출이 치기공과 학생의 스트레스와 순음청력에 미치는 영향)

  • Yon, Jung-Min;Lee, Ju-Hee;Kim, Dae-Hyun;Lee, Og-Kyoung
    • Journal of Digital Convergence
    • /
    • v.14 no.4
    • /
    • pp.363-370
    • /
    • 2016
  • Noise is unwanted sound that is the reason of the stress and hearing loss. The current study attempted to estimate whether the noise of dental laboratory affected stress and pure tone audiometry (PTA) of dental laboratory technicians (DLTs) using heart rate variability, air and bone conduction audiometry. The age, heights, and weights of DLTs were resembled control. Standard deviation of normal to normal interval such as stress resistance and normalized HF of DLTs were significantly decreased, but heart rates, normalized LF, and LF/HF ratio of DLTs were significantly increased compared with control. In air conduction audiometry of DLTs, significant increments of thresholds encountered in 125, 250, 500, 1000, 2000, 3000, 4000, and 6000 Hz in the right ears and 125, 250, 500, 1000, and 2000 Hz in the left ears. Thresholds of bone conduction audiometry in both ears were significantly increased in 250, 500, 1000, 2000, and 4000 Hz. The findings in this study provide that stress and hearing loss observed in noise-exposed DLTs at dental laboratory. Therefore, proper safety precautions should be carried out at dental laboratory.