• 제목/요약/키워드: Air hearing

검색결과 79건 처리시간 0.028초

군용 비행장에서 청력손실의 위험요소 분석 (Risk Analysis of Hearing Loss in the Air Base)

  • 김선경;이승현;김동수
    • 한국군사과학기술학회지
    • /
    • 제15권2호
    • /
    • pp.186-192
    • /
    • 2012
  • Noise is a major cause of hearing loss in the air base. There are lots of risk factors of hearing loss including noise, and hearing loss can be accelerated by combined effects of these risk factors. Here in, we reviewed risk factors of hearing loss, and analysed key risk factors inducing hearing loss in the air base. Risk factors exacerbating hearing loss with noise were mainly investigated in this research because noise could not be an avoidable risk factor in the air base. Analysed data will contribute to make green environment minimizing hearing loss of pilots and supporting personnels in the air base.

군대 청력 보호구(귀마개) 사용 및 착용 안전효과 실태조사 (The Research of Safety Effects by using a Hearing Protection(Ear Plug) in the Military)

  • 황성호;주묘경;박재범
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.103-106
    • /
    • 2013
  • During a military service, noise has unusual characteristics, and constitutes a serious hazard to hearing of military servicemen. The purpose of this study is to understand the use of hearing protection and to assess the safety effects of hearing protection by using a ear plug in military. A total of 208(the army : 101, an air force : 107) serviceman were studied utilizing a questionnaire to know how many serviceman use the hearing protection and a total of 202(the army : 110, an air force : 92) serviceman were also studied using a ear fit validation device to assess the safety effects of hearing protection by using a ear plug. The results showed that the army have low used of hearing protection than an air force because of the low frequency of the noise exposure in the army. Personal attenuation rate was increased with 8 dB after fitting education. Therefore, it is recommended that use of proper hearing protection and fitting education was more suitable for military servicemen who were being exposed of the noise in domestic military.

전정구형낭 청력에 관한 연구 (A Study on Vestibulosaccular Hearing)

  • 허승덕
    • 말소리와 음성과학
    • /
    • 제4권3호
    • /
    • pp.179-186
    • /
    • 2012
  • The aims of this study are to consider auditory physiological characteristics and to confirm audiological evaluation and interpretation in regards to cases of sensorineural hearing loss that observe an abnormal AB gap. Vestibulosaccular hearing occurs when there is an abnormally large air-bone gap (AB gap) in sensorineural hearing loss, also known as pure cochlear conductive hearing loss. Generally, an AB gap is caused by damage to the external and/or middle ear. In conductive hearing loss, loss of air condition hearing occurs due to a loss of resonance in the outer ear and/or impedance mismatching in the middle ear. Most of these types of hearing loss can be treated medically and surgically. However, there is no medical treatment for an AB gap in sensorineural hearing loss and hearing loss can worsen gradually or suddenly. In addition, many studies have reported that head trauma makes hearing loss even more serious. Therefore, in order to differentiate between conductive hearing losses, it is important to check whether or not there is an enlarged vestibular aqueduct by means of temporal bone computerized tomography and/or magnetic resonance imaging.

Multiple Ossicular Dislocation Including Stapediovestibular Dislocation Presenting with Conductive Hearing Loss

  • Lee, Geonho;Kim, Yoonjoong;Kim, Bong Jik
    • Journal of Audiology & Otology
    • /
    • 제25권3호
    • /
    • pp.159-162
    • /
    • 2021
  • Temporal bone trauma can cause hearing loss and in case of prolonged conductive hearing loss, traumatic ossicular injury should be considered. Separation of the incudostapedial joint is the most common lesion, and stapediovestibular dislocation is relatively rare but can easily cause perilymphatic fistula. Here, we report a very rare case of external stapediovestibular dislocation after trauma, ending up with successful surgical outcome. A 27-year-old man with non-progressive hearing loss on the right side since childhood visited the clinic. Audiogram showed a conductive hearing loss with air-bone gap of 55 dB on the right side. Temporal bone CT revealed the disruption of ossicular chain. An exploratory tympanotomy identified multiple ossicular disruptions including external stapediovestibular dislocation with shiny fibrous membrane sealing the oval window. Ossicular chain reconstruction was performed using the total ossicular replacement prosthesis of titanium. A postoperative audiogram showed a recovery of air-bone gap less than 10 dB. To the best of our knowledge, this is the first case of external long-standing stapediovestibular dislocation, with oval window completely sealed with fibrous membrane, ending up with successful hearing recovery by surgery. This case would help dealing with such condition which can be encountered in the clinic.

Multiple Ossicular Dislocation Including Stapediovestibular Dislocation Presenting with Conductive Hearing Loss

  • Lee, Geonho;Kim, Yoonjoong;Kim, Bong Jik
    • 대한청각학회지
    • /
    • 제25권3호
    • /
    • pp.159-162
    • /
    • 2021
  • Temporal bone trauma can cause hearing loss and in case of prolonged conductive hearing loss, traumatic ossicular injury should be considered. Separation of the incudostapedial joint is the most common lesion, and stapediovestibular dislocation is relatively rare but can easily cause perilymphatic fistula. Here, we report a very rare case of external stapediovestibular dislocation after trauma, ending up with successful surgical outcome. A 27-year-old man with non-progressive hearing loss on the right side since childhood visited the clinic. Audiogram showed a conductive hearing loss with air-bone gap of 55 dB on the right side. Temporal bone CT revealed the disruption of ossicular chain. An exploratory tympanotomy identified multiple ossicular disruptions including external stapediovestibular dislocation with shiny fibrous membrane sealing the oval window. Ossicular chain reconstruction was performed using the total ossicular replacement prosthesis of titanium. A postoperative audiogram showed a recovery of air-bone gap less than 10 dB. To the best of our knowledge, this is the first case of external long-standing stapediovestibular dislocation, with oval window completely sealed with fibrous membrane, ending up with successful hearing recovery by surgery. This case would help dealing with such condition which can be encountered in the clinic.

BONE CONDUCTION TELEPHONE FOR THE HEARING IMPAIRED

  • Kang, Kyeongok;Kang, Seonghoon
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.1064-1069
    • /
    • 1994
  • In order to realize the function of human interface of telecommunications whose objective is to interchange useful information among persons, we developed a bone conduction telephone with which hearing impaired persons with conductive or noise-induced hearing loss and presbycusis can communicate with each other without any other additional devices such as hearing aids. The bone conduction telephone we developed has chatacteristics as follows : (i) a hearing impaired person and a normal hearing person can communicate by bone and air conduction hearings, respectively, using only this telephone set because, as its receiver, it uses a bone conduction vibrator with which we can realize such function with the voice coil and damper of a small speaker unit, the vibrating plate, etc., (ii) it has tone control function compensating hearing losses of hearing impaired persons according to their hearing loss/frequency chatacteristics. Using the tone control function together with a received volume control, it has the received volume range of 20dB in loudness rating; and (iii) it has the function of three emergency calls and a bell lamp as the visual display of a received call.

  • PDF

정원창 구동기의 진동체 성능 평가를 위한 내이 물리모델 (A Physical Cochlear Model for Transducer Performance Evaluation of Implantable Hearing Aid with Round Window Driver)

  • 신동호;임형규;정의성;성기웅;이정현;조진호
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.150-155
    • /
    • 2013
  • Recently, various hearing aids are developed to overcome hearing loss. There are available hearing aids, such as air conduction hearing aid, implantable middle ear hearing aid and so on. But air conduction hearing aid is inconvenience caused by howling, and ossicle chain driving type implantable middle ear hearing aid has some week point due to problem of possible nercobiosis of coupling spot along incus long process. In recent years, in order to improve these shortcomings round window (RW) driving hearing aid has been paying attention. In this paper, the physical cochlear model is proposed for a performance evaluation of the RW driving hearing aids of a transducer. In order to verify an experiment proposed on a performance of physical cochlear model, the transducer which has ossicles characteristics is used. By measuring and comparing the frequency characteristics of transducer with ossicles and human temporal bone, performance of physical cochlear model was verified. As from the result of experiment, it is expected that an implemented cochlear model is useful for evaluating characteristics of RW transducer.

고속 스핀들용 공기 베어링의 열 특성에 관한 연구 (A Study on Thermal Characteristics of Air Bearing System for High-Speed Spindle)

  • 이득우;이종렬;김보언;안지훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.1021-1026
    • /
    • 2000
  • The thermal characteristics of high-speed air spindle system with built-in motor are studied. Experiment and finite element method analysis obtain temperature rise and temperature distribution of housing. For the analysis three-dimensional model is built and temperature rise and distribution in thermal steady state are computed for each rotational frequency. Generally. It is said that the heat generation of air bearing is negligible. But it is certain that the heat generation of air bearing can not be negligible especially in high-speed conditions Frequency response test for air spindle system is executed. In case that the heat generation of air spindle system is high, natural frequency of the system becomes lower when it reaches thermal steady-state and it means that the stiffness of air hearing becomes smaller due to the change of bearing clearance. It is shown that the temperature rise of all spindle system causes thermal expansion md induces the variation of hearing clearance. In consequence the st illness of air bearing becomes smaller.

  • PDF

성인 남성에서 흡연이 기도청력역치에 미치는 영향 (Effect of cigarette smoking on air-conduction hearing threshold level in adult men)

  • 김진석;예민해;천병렬;우극현;강윤식;김건엽;이영숙
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권2호
    • /
    • pp.285-292
    • /
    • 1998
  • 흡연과 기도청력역치와의 연관성을 알아보기 위하여 1996년 1월 1일에서 1997년 7월 31일 사이에 종합 건강진단을 받기 위하여 내원한 성인 남성 1,887명을 연구대상으로 선정하였다. 주파수대별 순음기도청력 검사, 이완기 혈압, 총콜레스테롤, 공복혈당, 혈구용적치 그리고 비만도를 검사하였다. 설문지를 이용하여 연령, 직업, 흡연상태를 조사하였다. 흡연군이 비흡연군에 비하여 250 Hz, 500 Hz, 1000 Hz 그리고 4000 Hz 주파수에서 기도청력역치가 유의하게 높았다(p<0.05). 저주파수영역 평균청력 중간주파수영역 평균청력, 고주파수영역 평균청력에서 흡연군이 유의하게 기도청력역치가 높았다(p<0.05). 다중회귀분석 결과, 흡연상태는 연령, 직업, 이완기 혈압, 공복혈당, 총콜레스테롤, 혈구용적치, 비만도의 영향을 조정 한 후에도 유의한 변수였으며(p<0.05), 연령이 많고, 생산직이고, 혈구용적치가 높고 비만할수록 유의한 청력저하가 관찰되었다(p<0.05). 그러나 이완기혈압, 총콜레스테롤 그리고 공복혈당은 청력저하와 유의한 관련성이 없었다. 이상의 결과를 볼 때, 흡연은 성인 남성의 청력저하와 연관성이 있었다.

  • PDF

Safety and efficacy of transcutaneous bone conduction implant surgery for hearing improvement in microtia patients with bilateral hearing impairment

  • Cheon, Jeong Hyun;Lee, Hyung Chul;Im, Gi Jung;Park, Jung Youl;Park, Chul
    • Archives of Plastic Surgery
    • /
    • 제46권6호
    • /
    • pp.525-534
    • /
    • 2019
  • Background In microtia patients with bilateral hearing impairment, hearing improvement is crucial for language development and performance. External auditory canal reconstruction (EACR) has been performed to improve hearing, but often results in complications. We performed transcutaneous bone conduction implant (TBCI) surgery in these patients. This study aimed to evaluate the safety and efficacy of TBCI surgery. Methods A retrospective review was performed of five patients who underwent auricular reconstruction and TBCI surgery and 12 patients who underwent EACR between March 2007 and August 2018. Hearing improvement was measured based on the air-bone gap values using pure-tone audiometry over a 6-week postoperative period. We reviewed other studies on hearing improvement using EACR and compared the findings with our results. The surgical techniques for TBCI were reviewed through case analyses. Results Postoperative hearing outcomes showed a significant improvement, with a mean gain of 34.1 dB in the TBCI cohort and 14.1 dB in the EACR cohort. Both gains were statistically significant; however, the TBCI cohort showed much larger gains. Only three of the 12 patients who underwent EACR achieved hearing gains of more than 20 dB, which is consistent with previous studies. All patients who underwent TBCI surgery demonstrated hearing gains of more than 20 dB and experienced no device-related complications. Conclusions TBCI is a safe and effective method of promoting hearing gains in microtia patients with bilateral hearing impairment. TBCI surgery provided better hearing outcomes than EACR and could be performed along with various auricular reconstruction techniques using virgin mastoid skin.