• 제목/요약/키워드: Air flowrate

검색결과 130건 처리시간 0.022초

주방환기용 그리스 필터의 형상설계에 관한 수치해석 (A Numerical Study on the Design of a Grease Filter for Kitchen Ventilation)

  • 김기정;배귀남;김영일;허남건
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.619-629
    • /
    • 2003
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. Since the inertial impaction is a dominant particle removal mechanism of the grease filter, the performance of the filter is greatly affected by the geometry. This numerical study has been conducted to investigate the effect of geometry on the performance of grease filters for four models having nominal flowrate of 100 m$^3$/h. Four models were designed by changing the shape of impaction surface, the length of eyelid, and the number of eyelids of the grease filter. The flow field and particle trajectories in the grease filter with a flow chamber were simulated using the commercial code of STAR-CD. The difference of air velocity and pressure distributions among four models was discussed in detail. The collection efficiency curves and the pressure drops of four models were also compared. It was found that the grease filter model with flat top surfaces shows highest performance among four models, having high particle collection efficiency and relatively low pressure drop. The cutoff diameter of this model representing 50-% collection efficiency is about 7.1 ${\mu}{\textrm}{m}$ for water droplets at 100 m$^3$/h.

SPIV 기법을 이용한 비접촉 그리퍼에 의해 공중부양된 유연판의 3차원 변형 특성 측정 (Measurements of 3-D Deflection Characteristics of a Flexible Plate Levitated by Non-Contact Grippers Using SPIV Method)

  • 김재우;김준현;이영훈;성재용
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.54-62
    • /
    • 2021
  • This study has investigated the 3-D deflection characteristics of a flexible plate levitated by non-contact grippers using SPIV method. The measuring instrument consisted of a flexible plate located under four non-contact grippers and two cameras at the bottom of a transparent acrylic plate. Measurements were made on two materials (PVC and PC) for the plate with 50×50 cm2 area and 1 mm thickness. The deflection characteristics and flatness vary depending on the plate material, the gripper position and the air flow supplied to the gripper. For the material of PVC, the overall defection is convex. As the gripper position goes outward from the plate center, the upmost bending point also moves to the outside of the plate with the flatness increasing. However, the air flow rate does not affect the deflection pattern except for the small increase of flatness. For the material of PC, the shape of deflection changes from convex to concave as the gripper position goes out. The flatness is the highest at the point of transition from convex to concave, but the air flowrate has little effect on the flatness.

하수처리장의 포기조 최적 DO 농도 산정 및 공기송풍량 자동제어를 통한 에너지 절감 효과 도출 (A Study on Energy Saving Effect from Automatic Control of Air Flowrate and Estimation of Optimal DO Concentration in Oxic Reactor of Wastewater Treatment Plant)

  • 김민한;지승희;장정희
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.49-56
    • /
    • 2014
  • 생물학적 하수처리공정에서 안정적인 방류수질 확보와 처리 비용을 적게 하는 것은 매우 중요하다. 하지만 유입수 유량 및 성분 농도의 변화와 미생물의 비선형적인 동특성, 기타 환경 요인에 의해서 최적의 운전 제어를 하기가 쉽지 않기 때문에, 기존의 하수처리장에서는 필요한 양 이상의 폭기 및 화학물질을 과량 주입하는 방법 등을 사용하였다. 본 연구에서는 포기조에서 미생물에 필요한 용존산 소농도를 유지함과 동시에 과폭기로 인한 전력 비용을 감소할 수 있는 최적 제어 방법을 제안하였다. 최적 제어를 위하여 실시간 미생물 호흡률 측정기(Oxygen uptake rate, OUR)을 이용하여 측정하였고, 실시간 호흡률 측정값을 바탕으로 현재 미생물에 필요한 최적 DO 농도를 제안하였으며, 이에 따라 공기송풍기가 자동제어될 수 있도록 구성하였다. 최적 제어 방법을 통하여 하수처리장 포기조의 공기 송풍량에 소요되는 전력비용을 절감할 수 있었다.

흡입관 열교환기를 이용한 탄화수소계 냉매용 냉동사이클의 성능 분석 (Performance Analysis of Refrigeration Cycle of Hydrocarbon Refrigerant using Suction-Line Heat Exchanger)

  • 구학근
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2195-2201
    • /
    • 2009
  • 본 논문은 R290, R600a, R1270과 같은 탄화수소계 냉매를 사용하는 냉동사이클의 효율에 대한 흡입관 열교환기의 영향을 고려하였다. 이러한 흡입관 열교환기는 냉동시스템의 성능을 향상시킬 수도 있지만, 성능을 저하시킬 수도 있다. 본 논문에서는 흡입관 열교환기를 가진 냉동사이클의 성능 특성을 파악하기 위해서 정상상태의 수학적 모델을 사용하였다. 그리고 탄화수소계 냉매유량, 흡입관 열교환기의 내관 직경, 길이, 유용도 등과 같은 운전조건의 영향을 분석하였다. 연구결과는 흡입관 열교환기의 내관 직경, 길이, 유용도, 탄화수소계 냉매의 질량유량은 냉동사이클의 상대냉동능력지수, 냉동능력, 압축일량에 영향을 미치는 것을 알 수 있었다. 따라서 이러한 영향을 상세히 파악하여, 흡입관 열교환기를 설치한 탄화수소계 냉매용 증기압축식 냉동사이클을 설계할 필요가 있다.

해수냉난방용 판형 열교환기의 최적설계를 위한 수치적 연구 (Numerical Study for the Optimal Design of Plate Heat Exchanger Using at Seawater Air Conditioning)

  • 김현주;정영권;이호생;윤정인;손창효
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.29-35
    • /
    • 2014
  • Plate heat exchanger are being applied in the field of OTEC (ocean thermal energy conversion) and SWAC (seawater air conditioning) system. This study is to analyze numerically the heat transfer and pressure drop characteristics by using solid works flow simulation in order to offer optimum design data of plate heat exchanger. Plater heat exchanger proposed in this study is four types. The geometric design parameters of plate heat exchanger are a channel space, a flow orientation, a plate array, the flowrate of working fluid and so on. The main results for numerical analysis of plate heat exchangers are summarized as follows. Heat transfer performance for the channel space of 2.4 mm shows the highest value compared to other spaces. And, the Type 4 plate heat exchanger in Table 2 is the highest performance. From the pressure drop characteristics of plate heat exchanger, the channel space of 3.2 mm shows the lowest value. And Type 1 plate heat exchanger in Table 2 is the lowest pressure drop.

변압기 냉각 특성 해석 (Cooling Characteristic Analysis of Transformer's Radiator)

  • 김현재;양시원;김원석;권기영;이민제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1920-1925
    • /
    • 2007
  • A transformer is a device that changes the current and voltage by electricity induced between coil and core steel, and it is composed of metals and insulating materials. In the core of the transformer, the thermal load is generated by electric loss and the high temperature can make the break of insulating. So we must cool down the temperature of transformer by external radiators. According to cooling fan's usage, there are two cooling types, OA(Oil Natural Air Natural) and FA(Oil Natural Air Forced). For this study, we used Fluent 6.2 and analyzed the cooling characteristic of radiator. we calculated 1-fin of detail modeling that is similar to honeycomb structure and multi-fin(18-fin) calculation for OA and FA types. For the sensitivity study, we have different positions(side, under) of cooling fans for forced convection of FA type. The calculation results were compared with the measurement data which obtained from 135.45/69kV ultra transformer flowrate and temperature test. The aim of the study is to assess the Fluent code prediction on the radiator calculation and to use the data for optimizing transformer radiator design.

  • PDF

리튬브로마이드 수용액 유하액막의 흡수과정에 대한 근사 해법 : 증기 유동의 영향 (Approximate solutions on the absorption process of an aqueous LiBr falling film : effects of vapor flow)

  • 김병주;이찬우
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.144-152
    • /
    • 1997
  • Film absorption involves simultaneous heat and mass transfer in the vapor-liquid system. In the present work, the absorption process of water vapor by an aqueous soluton of LiBr flowing inside of the vertical tube was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the heat and mass transfer rate. Particularly the effects of vapor flow conditions on the absorption process were investigated in terms of the vapor Reynolds number. As the vapor Reynolds number increased, the shear stress at the vapor-solution interface also increased. Consequently solution film became thinner at higher vapor flowrate under the co-currentflow condition. Thinner film was capable of higher heat transfer to the wall and leaded to higher absorption rate of the water vapor into the solution film.

  • PDF

금속매쉬에서 천연가스/공기 표면연소의 화염안정성에 관한 실험적 연구 (An Experimental Study on the Flame Stability of Natural Gas/Air Mixture on the Metal Mesh)

  • 유현석;이현찬;이중성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.49-53
    • /
    • 2001
  • A conventional flame type gas combustion major portion of heat is transferred to the body by convection due to small radiant ability of the gas flame. Increasing the radiation component of heat flux in the combustion zone allows to augment the efficiency of gas utilization. Such effect can be reached by using radiative gas burner applied to metal mesh combustion. Basically the gas radiant burner consists of metallic mesh of high heat resisting steels. In terms of this regards, we have made the burner consisted of metal mesh and measured the radiative flame stability of natural gas/air mixture on the metal mesh burner. The pressure loss through the metal mesh is defined by pressure-velocity slope. The more increased the pressure-velocity slope of the metal mesh is, the wider the stable zone of radiave flame on the metal mesh burner is. And the augmentation of mixture flowrate through the metal mesh make narrow the permissible range of equivalence ratio.

  • PDF

부분적 예혼합 LPG/공기 화염에서 음향자진이 NOx 배출에 미치는 영향 (Effects of Acoustic Excitation on NOx Emission in Partially Premixed LPG/Air Flames)

  • 장준영;박성호;김태권
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.77-84
    • /
    • 2002
  • Measurements of NO and NOx emission of laminar partially premixed LPG/air flames with and without acoustic excitation are reported. The NOx emission at the tailpipe of a combustion chamber is determined by chemiluminescent analyser. The NOx measurements are taken in flames with several different center tube equivalance ratio( ø$\sub$o/), and overall equivalace ratio(ø$\sub$o/) for a fixed fuel flowrate. The NOx emission decrease to reach a minimum value at an optimum ø$\sub$c/ 2. Theø$\sub$c/ 2 flame gives a compromise of thermal NO and prompt NO mechanism. In the case of excitation. the visual shape of the flame is changed from laminar flame to turbulent-like flame. With increasing levels of excitation amplitude, an optimum value of the NO and NOx emission exists. A shorter flame caused by the enhanced upstream mixing due to acoustic excitation results in the reduction of NO and NOx emission in the present flames. The reduction of flame length affects the shorter residence time of center tube mixture, and significantly influences the NOx reduction.

상용차용 캐빈냉방기의 전산 열유동 해석 (Computational Thermal Flow Analysis of a Cabin Cooler for a Commercial Vehicle)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제16권2호
    • /
    • pp.17-23
    • /
    • 2012
  • The steady three-dimensional computational thermal flow analysis using standard k-${\varepsilon}$ turbulence model was carried out to investigate the heat transfer characteristics of a cabin cooler for a commercial vehicle. The heat exchanging method of this cabin cooler is to use the cooling effect of a thermoelectric module. In view of the results so far achieved, the air system resistance of a cabin cooler is about 12.4 Pa as a static pressure, and then the operating point of a cross-flow fan considering in this study is formed in the comparatively low flowrate region. The air temperature difference obtained from the cold part of an thermoelectric module is about $26^{\circ}C$, and the cooling water temperature difference obtained from the hot part of an thermoelectric module is about $3.5^{\circ}C$.