• 제목/요약/키워드: Air flowrate

검색결과 129건 처리시간 0.023초

CFX를 이용한 내부순환모드에서의 자동차 내부 유동특성 연구 (A study on Flow Characteristic inside Passenger's Compartment under Recirculation Cool vent mode using CFX)

  • 김윤기;양장식;김경천;지호성
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.25-30
    • /
    • 2010
  • The flow characteristics under recirculation cool vent mode is numerically studied using commercial fluid dynamic code(CFX). For the reliable analysis, real vehicle and human FE model is employed in grid generation process. The geometrical location and shape of panel vent, and exhaust vent is set as that of real vehicle model. The flowrate of the working fluid is determined as 330CMH which is equivalent to 70 percent of maximum capacity of HVAC system. The high velocity regions are formed around 4 each panel vent. Because of the non-symmetrically located exhaust, non-uniform flow and partial backflow near the door trim is observed. Streaklines start from each panel vent show the flow pattern of the airflow in the passenger's compartment very well.

석탄가스화기기로부터 발생된 저발열량 합성가스의 엔진연료 적용 연구 (Applicability to Engine Fuel of Low Caloric Synthetic Gas from Coal Gasification)

  • 장준영;김태권;유영돈;윤용승
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.595-600
    • /
    • 2003
  • This paper presents the applicability of low caloric synthetic gas from coal gasification to a gas engine system. A commercial LPG engine is modified to use the low caloric synthetic gas from coal gasification as the gas engine fuel. The modification is focused on the fuel supplying system, which includes air flowrate adjusting orifice, gas mixer, vaporizer, preheater, regulators, and fuel tank. The electrical system and others for the alternative fuel are also redesigned and replaced. From the results of engine performance data, we have demonstrated that the engine modified by using coal gasification gas is well operated from idle to wide open throttle conditions although the engine power is somewhat reduced relative to LPG fueled engine. This paper addresses the need to determine the practical potential for such a concept and to identify further research and development efforts that may be necessary.

  • PDF

바닥복사 난방시스템의 실내 열환경 특성에 대한 실험적 연구 (Experimental Study on the Indoor Thermal Characteristics for Floor Radiant Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.1-12
    • /
    • 2021
  • In this study, the effects of various operational conditions for floor radiant heating system were researched by experiments. Hot water supply set temperature, indoor air set temperature and supply water flowrate were considered as operational conditions. The control method for this system is On-Off control of automatic thermostatic valve. The purpose of this study is to evaluate indoor thermal control characteristics and energy performance, respectively. As a result, if lower supply water temperature is applied, the supply and return temperature difference is reduced and energy consumption of heat supply is also reduced.

식물조직배양용 바이오리액터의 농도제어 시스템 개발 (Development of an Automated Control System for Bioreactor using the Plant Tissue Culture)

  • 정석현;노대현;강창호;강석원;한봉희;이기명;나영선
    • Journal of Plant Biotechnology
    • /
    • 제31권4호
    • /
    • pp.307-312
    • /
    • 2004
  • 식물조직배양용 바이오리액터 8개의 배양액 P보, DO 농도를 on-line으로 계측하고 pH 농도 및 주입공기 량을 제어할 수 있는 시스템을 개발하였다. 시스템 제어용 컴퓨터 프로그램은 나리구근의 성장단계에 맞는 주입공기량을 추종제어방식으로 제어하며, 바이오리액터 내부의 pH 변화를 감지하여 오염을 감시하는 오염경보기능이 포함되어있다. 성장단계에 따라 적절한 주입공기량의 선정을 위하여 시뮬레이션 한 결과 배양초기에는 300 cc/min, 20일 경과 후에는 400 cc/mim, 40일 경과 후에는 500 cc/min, 60일 경과 후에는 600 cc/min, 그리고 80일 경과 후부터는 700 cc/min의 공기를 주입할 경우 바이오리액터내 나리구근의 분포가 고르게 나타났으며, 이 결과를 바이오리액터 배양실험에 이용하였다 배양액의 pH 농도 제어 시스템은 배양 전 기간동안에 제어 목표 값 (5.5$\pm$0.5)로 제어할 수 있었다.

광산 통기 네트워크 연구 (A Study on Mine Ventilation Network)

  • 김수홍;김윤광;김선명;장윤호
    • 터널과지하공간
    • /
    • 제27권4호
    • /
    • pp.217-229
    • /
    • 2017
  • 최근 국내의 탄광들은 오랜 가행으로 작업심도가 깊어지고 운행갱도가 길어지면서 지열에 의한 온도증가로 인하여 작업환경이 더욱 악화되고 있다. 갱내의 작업환경 개선을 위하여 A광업소를 대상으로 통기평가를 하였으며 갱내의 통기 효율을 증가시키기 위하여 통기전용수갱을 건설할 시에 온도 예측 프로그램인 CLIMSIM을 이용하여 온도에 대한 효과를 수치 해석하였다. A광업소의 필요 공기량은 $6,152m^3/min$으로 산출되었으며, 실제 총 입기량은 $4,710m^3/min$로 공기량이 $1,442m^3/min$ 부족한 것으로 나타났다. -395 ML에서 -488 ML까지 93 m 길이의 통기전용수갱을 건설하였을 시에 -488 ML 작업장의 온도가 현재보다 약 $3^{\circ}C$가 감소되었다. 인공신경망을 이용하여 -523 ML 개발시의 $CO_2$ 용출을 예측한 결과 채탄량과 탄층 두께가 증가할수록 $CO_2$의 발생량은 증가하였다. $CO_2$ 발생량에 가장 큰 영향을 주는 인자는 탄층 두께와 채탄량으로 나타났으며 통기량이 증가할수록 이산화탄소의 농도 저하에 큰 영향을 미치는 것으로 나타났다.

희박연소를 이용한 가스터빈 연소기의 저 $NO_{x}$ 특성 (The Low $NO_{x}$ Characteristics of a Lean Premixed Gas Turbine Combustor)

  • 손민규;안국영;김한석;김용모
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.66-70
    • /
    • 2001
  • The combustion characteristics have been investigated to develop the low $NO_{x}$ gas turbine combustor. The lean premixed combustion technology was applied to reduce the $NO_{x}$ emission. Also, the conventional combustor was designed and tested for the baseline of low $NO_{x}$ combustor performance. The test was conducted at the condition of high temperature and ambient pressure. The combustion air which has the temperature of 500K were supplied to the combustor through the air preheater. The temperature and emissions of $NO_{x}$ and CO were measured at the exit of combustor. The premixing chamber can be operated very lean condition of equivalence ratio around 0.35. The $NO_{x}$ was decreased with decreasing the equivalence ration. The CO was decreased with decreasing the equivalence ratio, but the CO was increased with decreasing the equivalence ratio below 0.45. But, at the very lean condition of equivalence ratio below 0.35 both NOx and CO were increased because of the flame unstability. The $NO_{x}$ was decreased slightly and CO was increased with increasing inlet air flowrate. This results can be used to determine the size of combustor. The low $NO_{x}$ combustor has lower values of $NO_{x}$ and CO compared with conventional one. Consequently the performance of combustor shows the possibility of the application to the gas turbine system.

  • PDF

메탄/공기 층류 부분 예혼합화염에서 예혼합 정도에 따른 화염구조와 질소산화물의 배출에 미치는 영향에 관한 연구 (The Study of Effects of Variable Parameters on Flame Structure and NOx Emission in Methane/Air Laminar Partially Premixed Flames)

  • 오정석;정용기;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.362-367
    • /
    • 2003
  • It is shown that the effect of variable parameters on flame structures and NOx emissions in the laminar partially premixed methane-air flames with a co-axial Bunsen burner. Objectives of this paper is to understand the effects of flow variables on NOx emissions and the flame structure with OH chemiluminescence, including reconstructed image by abel inversion processing at each conditions. A fuel flowrate of 200 [cc/min] was fixed and the amount of air was varied from 400 to 1200 [cc/min]. The experimental variables were equivalence ratio(${\Phi}$ fuel split percentage(${\sigma}$ and inner tube recess(x/D). Flow conditions were ranged from $1.36{\sim}4.76$(equivalence ratio), $50{\sim}100$(fuel split percentage) and $0{\sim}20$(inner tube recess). NOx analyzer and ICCD camera with a OH filter were used as a main experimental apparatus. In addition, Abel inversion, which is a kind of tomography and valuable to estimate a two-dimensional structure of co-axial flames from cubical information, was employed for combustion diagnostics. Results from this study indicate that the main effects depend on equivalence ratio and next sigma, x/D for NOx production and OH formation. Throughout Abel inversion, we could affirm the maximum position and the tendency of OH radical intensity by variants at five axial heights above the burner exit.

  • PDF

한강수계 광역상수도 원수관의 지열 영향 조사 (Geothermal Effects on the Underground Water Conveyance Pipe System from Han River)

  • 조용;박진훈;박태진;김영준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.171.2-171.2
    • /
    • 2010
  • Geothermal effects on the underground water conveyance pipe system have been investigated through the multiregional water supply system from Paldang water intake station. To make an investigation of raw water thermal energy, temperature sensors are installed the surface of the pipes of metropolitan area water supply system. In 2009 winter and early spring seasons, the monthly averaged temperatures at Paldang 2 intake stations are $1.94^{\circ}C$ in February, $4.96^{\circ}C$ in March, and $10.56^{\circ}C$ in April. After the transfer in 26.0 km distance of tunnel and buried pipe, the raw water temperatures are raised to $3.13^{\circ}C$, $6.04^{\circ}C$, and $11.39^{\circ}C$ respectively. As the temperature difference between the raw water and the air reduces, the temperature increasement is reduced by $1.19^{\circ}C$ in Feb., $1.08^{\circ}C$ in Mar., and $0.83^{\circ}C$ in Apr. Since the flowrate is over 1,150,000 $m^3$/day, it is estimated that the water exchanges a huge amount of heat over 1.0 Tcal a day with the ground.

  • PDF

코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구 (An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter)

  • 임기원;이완규
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.

OH PLIF를 이용한 부분 예혼합 화염의 화염구조에 관한 실험적 연구 (An Experimental Study on the Flame Structure of Partially Premixed Flame using OH PLIF)

  • 이승영;이종호;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.54-59
    • /
    • 2001
  • OH radical concentration have been measured in a methane-air partially premixed flames using PLIF. Excitation lines were selected $Q_{1}(6)$ branch, (1,0) band. The system is consisted of Nd:YAG laser, dye laser and frequency doubler to make pump beam for OH radical. On the direct photographs, flame height increases as fuel flow rate and equivalence ratio increase. And on the PLIF images, OH radical is distributed from premixed flame front to nonpremixed flame front through the flame structure with all equivalence ratio. OH overall concentrations increase with equivalence ratio. At the stoichiometric equivalence ratio, the peak of OH radical concentration exists strongly near the inner cone. As equivalence ratio is changed to richer, OH radical distribution goes thinly and the peak is increased as longitudinal direction. As the flow goes to the downstream, OH radical concentration decreases and broadens, because OH radical reacts with another species after OH formation at the initial oxidization. This phenomenon resembles radial distribution. At the l00cc fuel flowrate, the radial peak of OH radical exists from x/R=l.0 to 1.5.

  • PDF