• Title/Summary/Keyword: Air conditioning volume

Search Result 349, Processing Time 0.021 seconds

The Experimental Study on the Efficiency of Ventilation of Korean Paper (Hanji) (한지(韓紙)의 환기성능에 관한 실험적 연구)

  • 이종원;임정명
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.482-489
    • /
    • 2004
  • The purpose of this study is to reevaluate the performance of Hanji as a architectural material. Recent studies report that one of the causes of the Sick-HouseㆍSick-Building Syndrome is due to the contaminants from interior materials and the lack of ventilation. In this study, the properties of Hanji are investigated. The major focuses of this research are (1) how efficient the Hanji is for ventilation of the house and (2) whether the usage of Hanji brings required ventilation volume to the house. According to the test results, differential pressure in the air and the amount of ventilation showed linear relationship. Test results differ from various kinds of Hanji. Since houses usually have double window system, Hanji can be used to the windows system, especially for inner part of double window system. It is suggested that the combination of Hanji windows for the inner part and glass windows for outer part is very effective, and offers a solution to improvement of indoor air quality and the lack of ventilation with passive ventilation that has less energy consumption.

An Experimental Study on Multi-Fault Detection and Diagnosis Analysis of HVAC System (HVAC 시스템의 중복고장 검출을 위한 실험적 연구)

  • Cho Sung-Hwan;Hong Young-Ju;Yang Hooncheul;Ahn Byung-Cheon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.932-941
    • /
    • 2004
  • The objective of this study is to detect the multi-fault of HVAC system using a new pattern classification technique. To classify the effect of single-fault in determining the pattern, supply air temperature, OA-damper, supply fan, and air flowrate were chosen as experimental parameters. The combination of supply temperature, flow rate, supply fan and OA-damper were chosen as multi-fault conditions. Three kinds of patterns were introduced in the analysis of multi-fault problem. To solve multi-fault problem, the new pattern classification technique using residual ratio analysis was introduced to detect the multi-fault as well as single-fault. The residual ratio could diagnose single-fault or multi-fault into several patterns.

Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • Kim, N.H.;Kim, J.S.;Lee, Y.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Natural Convection in a Rectangular Enclosure with Localized Heating from Below (사각공간내에서의 부분바닥가열에 의한 자연대류에 관한 연구)

  • Han, H.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.287-297
    • /
    • 1995
  • In this study, the geometry consists of a two-dimensional rectangular enclosure with localized heating from below. The size and the location of the heater on the floor has been varied, and one of the vertical walls remains at a low temperature simulating a cold window. The governing equations for momentum, energy and continuity, which are coupled with turbulent equations have been solved using a finite volume method. A low Reynolds number $k-{\varepsilon}$ model has been incorporated to solve the turbulent kinetic energy and the dissipation rate. The heat transfer characteristics and the thermal environmental characteristics of the room have been obtained for various system parameters in a room with a partially heated floor.

  • PDF

An Experimental Study on the Low-Temperature Behavior of Stratified Fluids in the Square Cavity (저온에서 정방형 공간내 성층화된 유체의 열적거동에 관한 실험적 연구)

  • 강한용;이동석;김병철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.381-387
    • /
    • 2000
  • An experimental study on the stratified fluids was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in the square cavity. The same volume of water and silicon oil was filled in it. The experiments were performed with the variations of initial temperatures and cooling surface temperatures. And the effect of vertical or horizontal cooling surface positions in the square cavity was investigated. When the cooling surface temperatures were $-4^{\circ}C$ , the supercooling phenomena were observed for both cases of cooling surface positions in the full region regardless of the initial temperature of fluid. In the square cavity with horizontal cooling surfaces, the lower the initial temperatures were, the longer the supercooling durations were, and with vertical cooling surface the lower the initial temperatures were, the shorter the supercooling durations were.

  • PDF

Effects of Gas Pulsation in Piping Lines on Compressor Performance in a Double-Acting Reciprocating Compressor (복동식 왕복동 압축기의 연결 배관계 가스 맥동이 압축기 성능에 미치는 영향)

  • 김현진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.448-456
    • /
    • 2000
  • For piping line systems associated with a double-acting reciprocating compressor, an analytical study has been made on the gas pulsation in piping lines and its effects on the compressor performance. The transfer matrix which relates mass flow rate to the gas pulsation downstream of the compressor valve can be obtained by an acoustic model for piping line systems which include snubber and after-cooler with the aid of four pole theory Since mass flow rate is affected by the pressure pulsation in the pressure plenum, while the latter being determined by the former, iteration in the calculation should be made for convergence. The gas pulsation in pipings is found to have an adverse effect on the compressor's performance, and the magnitude of the gas pulsation can be lowered by increasing snubber volume.

  • PDF

Performance Test of Low Temperature Waste Heat Recovery Heat Exchanger Using Self-excited Oscillating Heat Pipe (자려 진동형 히트 파이프를 이용한 저온 폐열 회수 열교환기의 성능 실험)

  • 이욱현;이종현;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.853-859
    • /
    • 2000
  • In this study, low temperature waste heat recovery heat exchanger was developed using a principle of self-excited oscillating heat pipe. The heat exchanger of serpentine type was composed of extruded flat aluminum tube with 6 channels (3 nm$\times$ 2.75nm) and louvered fin. The heat transfer area density of heat exchanger was $331.9 m^2/m^3$. Working fluid is R141b and charge ratio was 40% by volume. Heat transfer rate and the effectiveness of heat exchanger was primary concern of this study. As a result, the effectiveness of heat exchanger was about 0.4-0.67, and recovered waste heat rate was about 4.5 kW per one unit of heat exchanger.

  • PDF

The Effects of Additives on the Thermal Properties of a Clathrate Compound (II) -The Case of Ethylene Glycol- (포접화합물의 열물성에 미치는 첨가제의 효과 (II) -TMA 물계 포접화합물에 Ethylene Glycol을 첨가한 경우-)

  • 정낙규;김진흥;김창오;김광일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.499-505
    • /
    • 2004
  • The objective of this study is to investigate the effect of supercooling repression on the TMA clathrate by adding ethylene glycol. For this purpose, phase change temperature, supercooling, specific heat, latent heat and rate of volume change were measured and evaluated experimentally for heat source temperatures of -6$^{\circ}C$, -7$^{\circ}C$, -8$^{\circ}C$. The results show that supercooling was decreased. Thus the experimental results are expected to be used for the increase of coefficient of performance of low temperature thermal storage system in the building.