• Title/Summary/Keyword: Air conditioning control method

Search Result 202, Processing Time 0.024 seconds

A research on the $CO_2$ Peak Point Control according to Ventilation Frequency during Sleeping (취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구)

  • Won, You-Mi;Kim, Dae-Seung;Lee, Woo-Jin;Kim, Dong-Gyu;Kim, Se-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.731-736
    • /
    • 2008
  • There was in a building and with the technical advance for a energy saving the secret efficiency of the building improved together and continuously was come. The indoor air environment brought about the deterioration which is remarkable because of it. But time of most the indoor air environmental matter is one in the element which healthily affects biggest in the moderns who lives from the interior space. Today the plan for the air environmental maintenance which dwelling space is appropriate is demanded, is the actual condition where the method of the ventilation control which is energy saving and efficient is necessary. From the research which it sees, number of ventilation 0.7 time of the aeration which is a domestic legal baseline is excessive is judged from the research which sees, The sleep hour assumes it stays most long the hour when, number of ventilation 0 time 0.1 times 0.4 times $CO_2$ consistency measurements and analyzes number of ventilation conclusive escape. And $CO_2$ peak point control leads it decides a data, effective and it talks an energy saving circulation control method and it does to sleep.

  • PDF

An Experimental Study on the Effect of Fluid Flow and Heat Transfer Characteristics by the Longitudinal Vortices (종방향 와동이 유체유동 및 열전달 특성에 미치는 영향에 관한 실험적 연구)

  • 양장식;김은필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.843-852
    • /
    • 2000
  • The flow characteristics and the heat transfer rate on a surface by interaction of a pair of vortices were studied experimentally. The test facility consisted of a boundary-layer wind tunnel with a vortex introduced into the flow by half-delta winglet protruding from the surface. In order to control the strength of the longitudinal vortices, the angles of attack of the vortex generators were varied from $\pm20\;degree\;to\;\pm45$ degree, but spacings between the vortex generators were fixed to 4 cm. The 3-dimensional mean velocity measurements were made using a five-hole pressure probe. Heat transfer measurements were made using the thermochromatic liquid to provide the local distribution of the heat transfer coefficient. By using the method mentioned above, the following conclusions were obtained from the present experiment. The boundary layer was thinned in the regions where the secondary flow was directed toward the wall and thickened where it was directed away from the wall. The peak augmentation of the local heat transfer coefficient occurred in the downwash region near the point of minimum boundary-layer thickness.

  • PDF

Improvement of the Performance of Solar Cooling Heating Systems(I) - Dynamic Load Calculation Using TRNSYS and an Optimization of Solar Systems - (태양열에 의한 냉방 및 난방시스템의 성능향상(I) - TRNSYS에 의한 동직열부하 계산과 태양열 시스템의 최적화 -)

  • Kang, Y.T.;Kim, H.K.;Ro, S.T.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.6
    • /
    • pp.696-707
    • /
    • 1988
  • This study simulates a typical solar system using the transient simulation program TRNSYS, and calculates the maximum cooling load of the model room of $50m^2$. In this study, energy rate control method is used in calculating a maximum cooling load. On the ground of the maximum cooling load of the model room, the variables that have an effect on the solar collection performance of the solar system are made a selection. Also in this study the trend of the solar collection performance is shown as the variables change. The results show that the variables which have an effect on the collection performance are collector area, collector mass flow rate, collector slope and the volume of storage tank, and the optimal value of Ac/Vt is not constant but varies as the collector area and the collector mass flow rate. Also the results show that for cooling system the optimal value of the collector slope is latitude minus $15^{\circ}$ during the seasonal operations, and twenty percent of the maximum cooling load is saved with the aid of the solar energy.

  • PDF

A Study on Economic benefits for Water Control Device Installed with a Flush Valve on a Toilet (세척밸브 급수제어장치 설치에 따른 경제적 효과 분석)

  • Park, Kang-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.656-661
    • /
    • 2011
  • The amount of water resources that can be used tend to be decreased gradually. In contrast, the rapidly increasing water consumption is a problem that need to be addressed. Renovation and equipment replacement to improve energy efficiency and to reduce expenditure for building usage is required. But the excessive initial investment cost and the prolonged of pay back period may be uneconomical choice. Water usage for cleaning the toilet bowl accounts for 27%of the total water usage. Water-saving valve that can select the amount of water for cleaning toilet bowl can be reduced expenditure. After installing water-saving valve, analysed the economic effects. Water-saving valves compared with flush valves, and researched the amount of water usage. Then analyzed for the economic effects. Water-saving valve was used 5.6 ${\ell}$/time for cleaning toilet bowl. In contrast, flush valve was consumed 8.4 ${\ell}$/time. Water-saving valve's water-saving rate was 33.3%. The initial payback period for Water-saving valve was 459.5 days. By a small investment in water saving valve, the economic benefits can be obtained.

A Development of the On-line Maintenance and Management System for the HVAC Systems and the Evaluation of Its Effects (공조설비 온라인 유지관리시스템 개발 및 효과분석)

  • Lee, Tae-Won;Kim, Yong-Ki;Woo, Nam-Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.11
    • /
    • pp.591-598
    • /
    • 2009
  • The service quality with the various building equipments tends to depend on the individual superintendent's capability and efforts generally and this often lead to poor maintenances and managements of them. N-BMS(Networked Building Management System), proposed in this study, is a new type of building management method, which links principal equipments within many buildings into a communication network and carries out several significant missions such as fault detection, deterioration diagnosis and control the equipments and so on, as well as monitoring which is the main and unique purpose of the conventional BMS. How to construct the N-BMS was considered to keep performance of equipments high and thus to save energy and resource. LCC(Life Cycle Cost) based analysis was also performed in order to verify the effects of some maintenance and management works for the building HVAC systems.

Study on the Measuring Method and Reliability of Top Clearance of Variable Swashplate Type Compressor (가변 사판식 압축기의 탑 클리어런스 측정 방법 및 신뢰성 확보에 관한 연구)

  • Kim, Young-Shin;Na, Seung-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.89-94
    • /
    • 2016
  • In this experimental study, the effects of top clearance on the performance of automotive a/c compressor were studied. Top clearance measuring device was also developed to ensure the reliability using vacuum conditions to secure constant control of top clearance without external environmental influence. Our results revealed that the improvements in compressor performance according to different top clearance values using the same compressor and same operator were about 4.12% at 800 rpm and about 7.8% at 2,000 rpm in 0.243~0.252 mm of top clearance compared to 0.431~0.456 mm of top clearance. To confirm the consistency in measuring top clearance affecting compressor performance, the top clearance measuring device was developed in this study using a vacuum pump. After performing reliable tests repeatedly, the distribution of measuring values under this device was within 0.99~1.83%, indicating that the constant test data in compressor performance was not affected by any other external environment.

Design of Controllers for the Stable Idle Speed in the Internal Combustion Engine

  • Lee, Young-Choon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.54-60
    • /
    • 2001
  • This paper deals with control design method having anticipation delay which is proposed for the discrete nonlinear engine where system dynamics is not accurate. Due to the induction-to-power delay in internal combustion(IC) engine having abrupt torque loss, underdamping and chattering in engine idle speed becomes a serious problem and it could make drivers uncomfortable. For this reason, Three types of the closed-loop controller are developed for the stable engine idle speed control. The inputs of the controllers are an engine idle speed and air conditioning signal. The output of the controllers is an duty cycle to operate the idle speed control valve(ISCV). The proposed controllers will be useful for improving actual vehicles since these shows good test

  • PDF

A Study on Improvement of Controller Performance using Intelligent Control Method

  • Yoo, Seung-Sun;Kim, Moon-Seong;In, Chi-Ho;Kwak, Hoon-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.2031-2034
    • /
    • 2002
  • In this paper, by comparing the performance of HVAC(Heating Ventilating and Air Conditioning) by the typical PI(Proportional Integral) control and the HVAC by the new neural network control, it will show the applicability of neural network control algorithm to HVAC of buildings. These show that neural network system that can respond to changes in temperature and system can replace PI control that has been conventionally used in buildings.

  • PDF

A Study on the smoke control in underground space of the buildings (건축물 지하생활공간의 연기제어 기술개발 및 실물모의실험)

  • Bae, Sang-Hwan;Baik, Ki-Seung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.107-110
    • /
    • 2008
  • This study is aimed to develop fundamental technology on the smoke control method by simulation model and scale model simulation technique in underground space. Thereby, this research aimed to establish design elements and technologies required for smoke control system that is suitable to underground spaces of the high-rise residential-commercial and office buildings in order to minimize the loss of lives and property damage in case of fire.

  • PDF

Analysis of New Intelligent Control Method for Performance Improvement (성능향상을 위한 새로운 지능형 제어방식 고찰)

  • 김문성;곽훈성
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.4
    • /
    • pp.60-67
    • /
    • 2001
  • In this paper, by comparing the performance of HVAC(Heating Ventilating and Air Conditioning) by the typical PI (Proportional-Integral) control and the HVAC by the new neural network control, it will show the applicability of neural network control algorithm to HVAC of buildings. These show that neural network system that can respond to changes in temperature and system can replace PI control that has been conventionally used in buildings.

  • PDF