• Title/Summary/Keyword: Air conditioner outdoor units

Search Result 22, Processing Time 0.024 seconds

Structural Vibration Characteristics for an Outdoor Units Support of an Air-conditioner (에어컨 실외기 받침대의 구조진동 특성)

  • Ryu, Bong-Jo;Song, Seon-Ho;Lim, Chae-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.215-217
    • /
    • 2008
  • This paper deals with the structural vibration characteristics for an outdoor units support of an air-conditioner. Even though main noise sources are compressor noise and fluid noise which is caused by the fan, the structural modification of the outdoor units support may affect vibration and noise. In this paper, damping ratios for two kinds of an outdoor units support of an air-conditioner are measured through the modal testing. In order to reduce the structural borne noise due to an outdoor units support of an air-conditioner, four kinds of rubber materials are selected and tested.

  • PDF

Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.

Effect of Charged Refrigerant Amount on Operating Characteristics and Development of Detecting Program for System Air-Conditioner (시스템에어컨의 냉매충전량에 따른 사이클 운전특성 및 냉매량 판독 프로그램 개발)

  • Tae, Sang-Jin;Kim, Hun-Mo;Mun, Je-Myeong;Kim, Jong-Yeop;Gwon, Hyeong-Jin;Jo, Geum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.427-432
    • /
    • 2005
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in system air-conditioner than in a general single air-conditioner. Experiments were performed for 6 HP outdoor units with 3 indoor units in a psychrometric calorimeter. The experimental amount of charged refrigerant were ranged from 60% to 140% with 10% increasement. Fuzzy algorithm were emploeed for detecting the charged refrigerant amount in a system air-conditioner. The experimental data were used for curve fitting for general ranges for indoor and outdoor temperature conditions. membership function were determined for whole ranges of experimentally measured data and rulebase were defined for each amount of refrigerant charge. Developed program successfully predicted the measured data within 10% resolution range.

  • PDF

Optimal Design of the Pipe Configuration of an Air Conditioner Outdoor Unit Considering Vibration Characteristics (진동특성을 고려한 에어컨 실외기 배관의 최적설계)

  • Kim, Jun-Hyung;Park, Chang-Bae;Choi, Soo-Yong;Min, Je-Hong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.655-660
    • /
    • 2004
  • The pipes in the outdoor unit of an air conditioner are designed to reduce the vibration effect of the compressor. Three-dimensional structure of the pipe could provide various design choices and the resultant vibration characteristics of the outdoor units. A design program has been developed for an eligible parametric study of pipe design and automatic vibration analysis using commercial software, I-DEAS, and its macro. Optimal design of pipe configuration has been performed using the commercial software, iSIGHT. The optimized design shows 70 percents improvement in the vibration characteristics of the outdoor unit of an air conditioner.

  • PDF

Refrigerant Amount Detection Technology for System Air-Conditioner Using Design of Experiment (실험계획법을 이용한 시스템에어컨의 냉매량검지 기술개발)

  • Lee, Soo-Young;Takeichi, Hisashi;Tae, Sang-Jin;Yoon, Baek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.26-32
    • /
    • 2010
  • This paper is suggesting a new technology for refrigerant amount detection of a system air-conditioner installed under various installation conditions. System air-conditioner was introduced to domestic market first in 2000. It consists of one or a series of outdoor units and a number of indoor units connected with single pipe line to the outdoor unit. The system can vary the capacity from 2.0 kW to 186 kW. For the system Installed under long and high-elevated condition, about 100 kg of refrigerant is charged in the whole system. In this paper, the new technology RAD (Refrigerant Amount Detection) with edge technology of refrigerant cycle control and measurement of a system air conditioner was developed and investigated for its application for the various installation conditions.

Evaluation of energy efficiency ratio in the mixed air conditioner system (혼합 공조 시스템의 EER(A) 평가)

  • 김병순;이승홍
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.542-548
    • /
    • 1999
  • Instead of testing split air conditioners, an empirically based calculation procedure may be used to estimate the Energy Efficiency Ratio at ARI A test conditions. Typically, the system involving the indoor unit well sold and the given outdoor unit is called the matched system. All other systems involving a given outdoor unit and other indoor units are called the mixed systems. To estimate the EER(A) for the mixed systems, EER(A) for the matched system must be known, Generally, the EER(A) for the matched system is known. This procedure relies on independent measurements and calculations made on an outdoor unit in conjunction with a matched indoor and a mixed indoor coil. A heat pump simulation model was used to quantify the effects of individual system components on the system performance. The procedure is applicable to all air-conditioning units having rated cooling capacities less than 19,000W and charged with refrigerant 22.

  • PDF

The Effects of the Refrigerant Charge on the Performance of an Air Conditioner with Capillary Tube Expansions (냉매충전량이 모세관 팽창장치를 가진 공기조화기의 성능에 미치는 영향)

  • 최은수;김종배
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.359-364
    • /
    • 2002
  • A popular type of residential air conditioner is the split system which has two separate units: indoor and outdoor units During field installation of the split system, the potential exists for not setting the charge exactly to the manufacturer´s specifications. The objective of this study is to investigate the effects of the refrigerant charge on the performance of the air conditioner. An air conditioner with capillary tube expansions was tested for various refrigerant charges. The results indicated that the more charge resulted in the more flowrate of the refrigerant. The flowrate of the refrigerant was one of the most important factors to understand the e(sects of the charge on the performance of the air conditioner with capillary tube expansions. Under-charge results in wide region of superheated vapor of the refrigerant in the evaporator, while over-charge results in high temperature of the liquid refrigerant in the evaporator.

Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner with high-head and long-line conditions (동시냉난방 시스템 에어컨의 고낙차 장배관 운전 신뢰성 평가)

  • Kim, Tae-An;Lee, Seung-Chan;Tae, Sang-Jin;Jung, Gyoo-Ha;Moon, Je-Myung;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.609-614
    • /
    • 2008
  • The heating and cooling performance of system multi-air conditioner under high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with 22 different working conditions. Experimental results were prepared on the p-h diagram. Also the oil level in the compressor was normally maintained at the safety zone for the system multi-air conditioner with high-head and long-line conditions.

  • PDF

Program Development for Detecting Charged Refrigerant Amount in System Air-Conditioner using Fuzzy Algorithm (퍼지 알고리즘을 이용한 시스템 에어컨의 냉매충전량 감지 프로그램 개발)

  • Tae S. J.;Choi C. S.;Kim H. M.;Cho K.;Moon J. M.;Kim J. Y.;Kwon H. J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.172-179
    • /
    • 2006
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in the system air-conditioner than in a general single air-conditioner. Experiments were performed for a 6 HP outdoor unit with 3 indoor units in a psychrometric calorimeter. The experimental amount of the charged refrigerant was ranged from $60\%\;to\;140\%\;with\;10\%$ increasement. Fuzzy algorithm was employed for detecting the charged refrigerant amount in the system air-conditioner. The experimental data were used for curve-fitting for the general ranges of indoor and outdoor temperature conditions. Membership function was determined for the whole ranges of experimentally measured data and rule-bases were defined for each charged refrigerant amount. Developed program successfully predicted the measured data within $10\%$ resolution range.

Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner for different refrigerant flow rates with high-head and long-line conditions (동시냉난방 시스템 에어컨의 냉매량 변화에 따른 고낙차 장배관 운전 신뢰성 평가)

  • Lee, Seung-Chan;Kim, Tae-An;Tae, Sang-Jin;Jung, Gyoo-Ha;Moon, Je-Myung;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.304-309
    • /
    • 2008
  • The heating and cooling performances of system multi-air conditioner for various refrigerant flow rates with high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, and the two different adjustments of refrigerant flow rates were +20 % and -20 %, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with two different refrigerant flow rates. Especially, the oil level in the compressor was normally maintained at the safety zone. Experimental results were prepared on the p-h diagram.

  • PDF