• 제목/요약/키워드: Air conditioner control

검색결과 182건 처리시간 0.024초

약계자 영역에서 PMSM 드라이브의 최대 토크제어 (Maximum Torque Control of PMSM Drive in Field weakening Region)

  • 이홍균;이정철;김종관;정동화
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.44-49
    • /
    • 2003
  • Permanent magnet synchronous motor(PMSM) is widely used in many applications such as an electric vehicle. compressor drives of air conditioner and machine tool spindle drives. PMSM drive system have become a popular choice in various application, due to their excellent power to weight ratio. This paper is proposed maximum torque control for field weakening operation of PMSM drive. At low speeds, the reluctance torque is used to maximize the output for a given current level. This is achieved maximum torque per ampere(MTPA) by selecting an optimal value of the direct stator current component. At high speeds, the system reaches a point at which the inverter will not be able to supply the desired voltage. In this case it is necessary to make use of an increased value the direct current component. The proposed control algorithm is applied to PMSM drive system, the operating characteristics controlled by maximum torque control are examined in detail by simulation.

도시철도차량용 국내 표준모델의 주제어 S/W개발(2) (Development of Control Software for KOREA Standard EMU)

  • 안태기;한성호;백종현;이수길;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.302-309
    • /
    • 1999
  • This paper is intended to provide a method to design control software fur the TCMS, train control and monitoring system. The TCMS with this control software will be applied KOREA Standard EMU. The control software is designed by SCADE Case tool to concern safety and reliability. The function for the EMU is implemented in software easily programmed, using a functional block, graphic programming language. the control software has modular design and each module is tested with SCADE simulator. This time we focus a HVAC(heater, ventilation and air conditioner controller) control module, present a design method and a simulation method for that module.

  • PDF

HFC-134a 자동차용 공조시스템의 열역학적 사이클 특성에 관한 연구 (A Study of Thermodynamic Cyclic Characteristics of HFC-134a Automotive Air-Conditioner System)

  • 이규현;원종필
    • 한국자동차공학회논문집
    • /
    • 제2권1호
    • /
    • pp.51-64
    • /
    • 1994
  • Analytical study on the thermodynamical cyclic behabiour and characteristics of HFC-l34a refrigerant for automotive air conditionser system for the replacement of existing CFC-12 has been carried out in this paper through development of system performance simulation program, expecially in the view point of system design considerations. The results indicate that HFC-l34a system will give a greater refrigerating capacity than CFC-12 if appropriate engineering measures such as proper codensers, flow controllers, etc., taken for certain operating conditions. The results, however, also show that the operating power for compression process increases over entire temperature range as a result of decreasing volumetric efficiency due to larger specific volume and increased discharging pressure. The present study results indicate that proper selection of condensing and evaporating temperature plus refrigerant control is very important performance factor to have better COP in the HFC-134a system design.

  • PDF

데이터센터의 합리적인 환경제어를 위한 장비 발열기준에 대한 연구 (A Study on a Heat-load of IT Equipments for the Thermal Environment Control in the Data Center)

  • 조진균;홍민호;정차수;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.938-943
    • /
    • 2006
  • The primary purpose of a computer room of data center and associated infrastructure is to support the operation of critical IT equipment. Traditionally, most owners of large critical data centers have been more than willing to accept a reasonable amount of computer room worker discomfort if necessary to support critical IT systems. All electrical equipment produces heat, which must be removed to prevent the equipment temperature from rising to an unacceptable level. Most information technology equipment and other equipment found in a data center or network room is air-cooled. Sizing a cooling system requires an understanding of the amount of heat produced by the equipment contained in the enclosed space, along with the heat produced by the other heat sources typically encountered.

  • PDF

온도, 습도, 기류를 이용한 하절기 VRF 시스템의 쾌적 제어 알고리즘 개발 (Development of Comfort Control Logic for VRF System in Summer Season by using 3 Environment Factors(Temperature, Humidity and Air flow))

  • 김종민;최재붕;이상원;조두호;이필호;김영진
    • 설비공학논문집
    • /
    • 제23권9호
    • /
    • pp.610-619
    • /
    • 2011
  • This paper investigates the simplified comfort index and control logic for VRF (Variable Refrigerant Flow) system by using 3 environmental factors such as temperature, humidity and air flow. Indoor test under thermal load was conducted to explore relationship of each environment factors that is related to simplified comfort index. Simplified comfort function that has 3 environmental variables was proposed based on survey results. Each factor is measured and comfort preference was surveyed by more than 30 subjects in the indoor comfort test. Moreover, control logic for VRF system was developed and then simulated by using thermal load calculation method and verified with test. The proposed comfort function was in good agreement with survey results, and also verification test trend of comfort change and maintenance are quite similar with survey. Furthermore, through the additional test data analysis some differences of comfort according to position of people staying in the test room were additionally investigated by air flow. People being under an exit of air in the indoor air-conditioner feel more comfortable condition and speed of response to comfort change is relatively fast.

에어컨부하 직접제어시스템 실증시험 및 운용방안에 관한 연구 (The Study on the Field test and Operational Method of a Direct Load Control System for Air conditioner)

  • 강원구;김충환;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2825-2827
    • /
    • 2000
  • In electric power industry. load balance has been one of the most fundamental and important management goals. Therefore. the strategy to achieve high quality load management now includes load balance besides the stabilization of electricity supply and quality management of electricity. Amongst many techniques of load management. direct load management has been actively studied and utilized to increase power facility and peak load suppression. Higher peak load situation is appeared during summer than during winter in Korea. and approximately 20% of the peak load is due to the load for air-conditioning. To cope with this peak load problem during summer KEPCO is performing a research project to develop a system to remotely control air-conditioning load using wireless communication. Currently, applicable facilities are limited to small-scale air-conditioning facility that has less than 2KW power capacity. This paper described the 1st year of efforts made in the study.

  • PDF

시험공간에 대한 냉방부하 실증실험 및 계산 (Verification Experiment and Calculation of Cooling Load for a Test Space)

  • 유호선;현석균;김용식;홍희기
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.641-651
    • /
    • 2003
  • In order to assess the reliability of a building energy simulation program (TRNSYS) from the standpoint of user, a set of verification experiment and calculation of cooling load for a test space is carried out. This work is a complement of the previous study that dealt with heating load for the same space. The test space is kept airtight to eliminate the source of uncertainties in modeling. A window-mounted, on/off controlled air-conditioner is used for cooling, whose performance has been established a priori. The calculation encompasses two models for evaluating cooling load in TRNSYS: energy rate control and temperature level control. Comparison of the total cooling loads obtained from different sets of experimental data enables to validate the measurements. The experimental result shows that the latent load is fairly large even in the absence of apparent air change in the space, which needs to be clarified. Each of hourly and daily accumulated sensible loads is compared between the experiment and two calculation models. Despite an inconsistency associated with solar irradiation, both of the models agree favorably with the experiment within a tolerance, illustrating their capability of properly predicting space thermal loads.

인간 적응형 가전기기를 위한 거주자 심박동 기반 신체활동량 추정 (Metabolic Rate Estimation for ECG-based Human Adaptive Appliance in Smart Homes)

  • 김현희;이경창;이석
    • 제어로봇시스템학회논문지
    • /
    • 제20권5호
    • /
    • pp.486-494
    • /
    • 2014
  • Intelligent homes consist of ubiquitous sensors, home networks, and a context-aware computing system. These homes are expected to offer many services such as intelligent air-conditioning, lighting control, health monitoring, and home security. In order to realize these services, many researchers have worked on various research topics including smart sensors with low power consumption, home network protocols, resident and location detection, context-awareness, and scenario and service control. This paper presents the real-time metabolic rate estimation method that is based on measured heart rate for human adaptive appliance (air-conditioner, lighting etc.). This estimation results can provide valuable information to control smart appliances so that they can adjust themselves according to the status of residents. The heart rate based method has been experimentally compared with the location-based method on a test bed.

PMSM 드라이브의 효율 최적화 벡터제어 (Efficiency Optimization Control of PMSM)

  • 이홍균;이정철;정택기;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1143-1145
    • /
    • 2002
  • IPMSM (Interior Permanent Magnet Synchronous Motor) is widely used in many applications such as an electric vehicle, compressor drives of air conditioner and machine tool spindle drives. In order to maximize the efficiency in such applications, this paper is proposed the optimal control method of the armature current. The controllable electrical loss which consists of the copper loss and the iron loss can be minimized by the optimal control of the armature current. The minimization of loss is possible to realize efficiency optimization control for the proposed IPMSM. The proposed control algorithm is applied to IPMSM drive system, the operating characteristics controlled by efficiency optimization control are examined in detail by simulation.

  • PDF

동기 리럭턴스 전동기의 약계자 영역을 고려한 효율 최적화 제어 (Efficiency Optimization Control for Field-Weakening Region of Synchronous Reluctance)

  • 이정철;이흥균;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1169-1171
    • /
    • 2001
  • Synchronous reluctance motors(SynRM) for the application such as an electric vehicle, compressor drives of air conditioner and machine tool spindle drives require a wide field-weakening speed range. In order to improve the efficiency performance in such applications, this paper has examined the loss and the efficiency characteristics of SynRM mainly in the field-weakening speed region over the base speed. The control strategy in order to offer a efficiency optimization operation is shown and the copper and iron losses driven the equivalent circuit model of the machine is minimized. The usefulness of the proposed efficiency optimization control is verified through the SynRM durve system.

  • PDF