• Title/Summary/Keyword: Air cleaning

Search Result 1,177, Processing Time 0.026 seconds

A study on the state of infection control in dental clinic (치과진료실에서의 감염관리 실태 조사)

  • Kim, Kyung-Mi;Jung, Jae-Yeon;Hwang, Yoon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.3
    • /
    • pp.213-230
    • /
    • 2007
  • The purpose of this study was to examine the state of infection control provided to members of Korean Dental Hygienists Association. The subjects in this study were dental hygienists who attended a symposium on July 1. 2006. after a survey was conducted, the answer sheets from 489 participants were analyzed, and the findings of the study were as follows: 1. Possession of disinfection room was being(72.7%), and person of infection control was zero(52.9%). Number of sterilizer was one(62.2%). 2. As a repetition choice, type of sterilizer was autoclave(97.9%), UV sterilizer(67.4%) and EO gas sterilizer(21.4%). As a repetition choice, infection materials was ethanol(84.1%). 3. Water tube of unit and chair was using of sterilized water(42.9%). Sterilizing of compressed air was no(69.0%). 4. Re-using of disposal was not using(62.5%), re-using disposal was suction tip(28.2%)(repetition choice) 5. In sterilization of instruments, hand-piece was every using time(28.4%), and reamer-file, bur, mirror, pincette, explorer, hand scaler and ultrasonic scaler were high in every using time. 6. Individual protection was high of using, cleaning of hands before treatment was every treatment(87.0%). Type of soap was liquid type in dental clinic(48.2%), infection soap in dental hospital(41.2%) and solid soap in public health center(50.6%). Answered that they need regular oral health education, and 82.9% respondents answered that they need oral health technicians in school. And 87.8% respondents needed individual oral health education for the benefit of better oral health.

  • PDF

Literatural Study on Tae-yeul (태열(胎熱)에 관한 문헌적(文獻的) 고찰(考察))

  • Gu Jin-Suk;Kim Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.235-253
    • /
    • 2001
  • Tae-yeul is the baby's disorder inheritted by its mother during fregnancy. This is due to its mother's overeating hot, fatty food and taking harmful medicine. So internal physical fever is accumulated in mother's body, and it heats up the placenta and the umbilical cord. Generally, this disorder means the skin disease that is occurred from $2{\sim}5$ months to 1 year after birth. It is specialized by the dirty oozing, a severe itching and the rash at its head and face. It is similar in its symptoms such as atopic dermatitis in western medicine. Recently, this disease has the increasing tendency of prevalence rate because of the bad atmosphere and the invironmental pollution. The results were summerised as follows; 1, 2, 3, 4 1. The causes of Tae-yeul are summarized by fragnat woman's contacting a cool air, overating a hot and toxic food and taking emotional shock. 2. The symptoms of Tae-yeul are the edema on upper eyelids, stifling convulsions, flush, the fever of one side body, the asthma of sputum increase, the yawing of the tired mind, the bowl complaint, the red urine and urination disturbance. 3. In the treatment method of Tae-yeul, its mother feed her milk after taking a madicine. So one must expect to be treated slowly. If one tries to treat it with a cool madicine quickly, it can cause vomitting or a serious disorder. 4. In the prescription of Tae-yeul, they used a Moktongsan, a Chiwhnagtang, an Yangyoubang, a Tojuksan, a Whangyunsan, a Juryungtang and a Kamdutang, etc.. For the method of cleaning face or bathing, they used Sasungsan, Whanbaekpijuntang. 5. Tae-yeul including Naesun, Taelyumchang, yousun, etc. is similar to the atopic dermatitis of western medicine in its symptoms.

  • PDF

A Survey on Environmental Safety Focussed on Cleanliness for Hospitalized Patients (병원환경의 안전관리를 위한 기초조사 -청결도를 중심으로-)

  • 박점희
    • Journal of Korean Academy of Nursing
    • /
    • v.7 no.1
    • /
    • pp.99-111
    • /
    • 1977
  • One of the fundamental provisions that a hospital requires is the environmental safety through cleanliness s. The effective management of atmospheric conditions, i. e. air purity, cleanliness of facilities furnitures and bed- linen instruments are direct- environment of hospitalized patients. Meeting physical cleanliness needs of patients, application of aseptic teaching while carrying out nursing measures and the cleanliness of hospital personnel are another categories of concern. This study was carried out, from March through April 1976, to investigate the degree of satisfaction on cleanliness that patients perceived, and to compare with that of nurses on their nursing performances. 44 questionaries categorized into 6 major concern were used. For the survey, 269 patients and 191 nurses of 3 general hospitals in Taegu: kyung-puk University Hospital, Presbyterian Mission Hospital, and Catholic Patima Hospital and 116 senior nursing students from Kyung-Puk University and Presbyterian School of Nursing were randomly sampled. Results are as follows : 1. Mean satisfaction score on cleanliness revealed to be average on patients, on nursing performance for cleanliness revealed to be average in nursing students and relatively high in graduate nurses. 2. Mean score of patients revealed to be significantly lower in comparison with that of nursing. 3. Mean score of nurses revealed to be significantly higher in comparison with that of nursing students. 4. Mean score of patients revealed to be significantly lower in comparison with nursing students. 5. Mean satisfaction score of patient3 in all categories revealed to be the lowest in the rank order . 6. The lowest categorial mean score revealed to be the linen and instrument in all three groups. Recommendations 1. A more satisfactory mean of cleaning (medical asperses of mouth thermometers needs to be developed. 2. Further investigation to clarify the difference between patients and nurses on hospital cleanliness is recommended.

  • PDF

A Study on the Methods of the Decorations Using Module Plants in Interior Spaces (모듈형 식물장식을 활용한 실내공간 장식방법에 대한 연구)

  • Lee, Jong-Ran
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.5
    • /
    • pp.62-69
    • /
    • 2015
  • The purpose of this research is to analyze the methods of the decorations using module plants in interior spaces. This research produced 18 types of the module plant decoration: considering the classifications of module plants(soil, hydroculture, moss), directions of module plants (up, side, down), assembling ways of module plants (horizontal, vertical). Applying these 18 types to the interior space decoration (floor stand, wall attach, ceiling hanging), 54 types were classified. After that, 150 cases of the decoration using module plants in interior spaces were collected and analyzed. In result, the cases were belong to 25 types of 54 types. The important types were the types to be able to decorate wide area of walls or ceilings without occupying floor area: SOIL-UP-VERTICAL, HYDROCULTURE-UP-VERTICAL, MOSS-SIDE-VERTICAL. These types were the decorations with function of bio-filter for air cleaning. Special types were SOIL-SIDE-HORIZONTAL, SOIL-SIDE-VERTICAL with soil developed not to pour and SOIL-DOWN-HORIZONTAL, SOIL-DOWN-VERTICAL with lucks not to pour soil. Plants will be used widely in interior design because of the awareness of eco-friendly design. The strength that module plants are portable, changable, able to exchange parts helps users to maintain plants in interior spaces. For designers, module plants are flexible materials in order to make variety of forms to adjust to interior spaces. The results of this research about methods of the decorations using module plants in interior spaces are useful to designers who want to design interior spaces eco-friendly and user-friendly.

Effect of Cetyltrimethyl Ammonium Bromide on Foam Stability and SiO2Separation for Decontamination Foam Application (거품제염을 위한 실리카 나노입자와 CTAB (Cetyltrimethyl Ammonium Bromide)의 거품안정성 및 분리특성 평가)

  • Choi, Mansoo;Kim, Seung-Eun;Yoon, In-Ho;Jung, Chong-Hun;Choi, Wang-Kyu;Moon, Jei-Kwon;Kim, Seon-Byeong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.173-182
    • /
    • 2018
  • As part of planning for waste minimization, decontamination foam has been considered as a potential application for the cleaning of radioactive contaminant. In this study, we synthesized silica particles to improve foam stability by varying synthesis parameters. Cetyltrimethylammonium bromide (CTAB) was found to influence the stability of the decontamination foam. The reason was that higher interaction between $SiO_2$ nanoparticles and surfactant at the air-water interface in aqueous solution is beneficial for foam stability. CTAB can also be used as an additive for the aggregation of silica nanoparticles. In the separation of $SiO_2$ nanoparticles, CTAB plays a critical role in the nanoparticles flocculation because of the charge neutralization and hydrophobic effects of its hydrocarbon tails.

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

Evaluation of Odor Dispersion from Livestock Building through Field Experiment (현장실험을 통한 축산시설로부터 배출되는 축산악취의 확산 평가)

  • Yeo, Uk-Hyeon;Lee, In-Bok;Ha, Tae-Hwan;Decano, Cristina;Kim, Rack-Woo;Lee, Sang-Yeon;Kim, Jun-Gyu;Choi, Young-Bae;Park, You-Me
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.21-30
    • /
    • 2019
  • Livestock odor is comprised of mixed type of odorous compounds. Among these, ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) are the two known major odor causing substances. Because high odor concentration reduces productivity of livestock and causes damage to the surrounding communities, quantitative analysis is needed to manage the odor inside and outside the livestock facilities. It is also necessary to evaluate odor dispersion according to the distance between the receptors taking into account the influence of odor source and weather condition. Therefore, in this study, we tried to evaluate the internal environment and odor dispersion from experimental pig house considering weather conditions. An experimental farm was specifically selected to eliminate the interference of odors generated by adjacent farms. $NH_3$ and complex odor were quantitatively analyzed using a gas detector and air dilution sensory method. The concentration of $NH_3$ and complex odor in pig house showed a distinct concentration difference according to the cleaning and ventilation conditions. $NH_3$ concentration and complex odor was lower than emission standard in the pig house and at the site boundary. The average $NH_3$ concentration (P1~P3) and the $NH_3$ concentration at the site boundary (S1) were strongly correlated with R=0.77. While the correlation for complex odor inside and at the site boundary had R=0.52. The correlation coefficient between $NH_3$ and the complex odor was 0.80.

Intelligent Home appliances Power Control using Android and Arduino (안드로이드와 아두이노를 이용한 지능형 가전제품 전력 컨트롤)

  • Park, Sung-hyun;Kim, A-Yong;Kim, Wung-Jun;Bae, Keun-Ho;Yoo, Sang-keun;Jung, Hoe-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.854-856
    • /
    • 2014
  • Has been released of make it possible to control the using for smart devices of a wide variety home appliances and electronics in smart appliances in accordance with the one person multi devices. In addition, is increasing rapidly for the number of the product on cleaning robot and refrigerator, air conditioning, TV, etc. these devices are using the implement up DLNA system. And at home and abroad for development and has provided with Iot and Alljoyn such systems. But currently using home appliances or electronic devices of there are a lot of the operating system non installed than the installed products. In addition, smart appliances do not use for user than buying existing electronic products a lot more. In addition, more occur for smart appliances of that do not use for the user on smart appliances rather than buying existing electronics. In this paper, Suggested and implemented for system of control such as smart devices to existed home appliance on not have an operating system, Using mobile device for want users to quantify the data to transfer from arduino board.

  • PDF

A study to detect and leaked personal information on the smartphone. (Web을 이용한 안드로이드 기기 제어 시스템 설계)

  • Kim, Wung-Jun;He, Yi-Lun;Park, Sung-Hyun;Ban, Tae-Hak;Kim, Yong-Un;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.845-847
    • /
    • 2014
  • In recent years, the mobile OS market, enlargement and, at the same time, Android has mounted various smart phones and feature air conditioning, smart TV, cleaning robot, camera, etc. that the number is being spread at a rapid pace. But a lot of devices to control the modules and applications at once, this is not a device for controlling the dissemination of applications all in one place, and in charge of the devices that allow you to manage applications are lacking. Accordingly, in this paper, use the Web Server registered in the appliance can be controlled by management, Web access, is proposing and designing the system. This is the current research is actively in progress in the field of IoT (Internet of Things) would be utilized.

  • PDF

Transmembrane Pressure of Backwashing, Filtration/Relaxation and the Sinusoidal Flux Continuous Operation Modes for Submerged Plate Membrane (역세척, 여과/이완 및 사인파형 연속투과 운전방식에 따른 침지형 평막의 막간차압)

  • Kim, Jae Hyo;Kim, Eun Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.29 no.4
    • /
    • pp.216-222
    • /
    • 2019
  • In this study, permeation experiments were conducted using naturally circulating spherical beads, backwashable plate membrane and the air supplied from the bottom of the MBR. The activated sludge solution was maintained at 8,000 mg/L of MLSS and compared transmembrane pressure (TMP) with respect to FR (filtration and relaxation), FR/BW (filtration and relaxation/backwashing), SFCO (sinusoidal filtration continuous operation) and SFCO/BW (sinusoidal filtration continuous operation/backwashing). As the backwashing flux decreased from 47 to $14L/m^2{\cdot}hr$, the TMP increased generally, but the TMP of FR system increased significantly comparing with SFCO. In addition, the backwashing method reduced more TMP comparing to the cleaning method using spherical beads, and it was confirmed that the operation method using the spherical beads and the backwashing simultaneously is more effective than each method.