• Title/Summary/Keyword: Air clean system

Search Result 287, Processing Time 0.029 seconds

A study on the food clean room system observing the regulations of HACCP (HACCP의 환경 최적화를 위한 식품 클린룸 설계에 관한 연구)

  • Won, Young-Jae;Suh, Kee-Won
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.520-526
    • /
    • 2009
  • This study proposed the optimum design values for the biological clean room system observing the regulations of Hazard Analysis Critical Control Point (HACCP). Even though the standard for industrial clean room system has been well established, the basis for biological food clean room system is the first stage. In order to prevent the contaminations in advance for food storages, processes, and distributions, the criterion of Hazard Analysis Critical Control Point is positively required. This study also suggested the possible ways of how to avoid the hazardous contaminations.

  • PDF

On-Site Measurement of the Inlet Air Evaporative Cooling Performance for a Centrifugal Turbo Compressor (CDA 인입공기 증발냉각을 통한 압축기 성능 개선장치 개발 연구)

  • Kim, Gyu Wan;Park, Jin Ouk;Kim, Heuy Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.873-879
    • /
    • 2014
  • In the present study, water vapor is injected at various positions in a Clean Dry Air (CDA) system such as a system inlet duct, compressor inlet, and compressor outlet by humidified air turbines. The application of evaporative cooling reduces the compression work and enhances the Energy Consumption Index (ECI) per unit volume. The main purpose of this study is to investigate the compressor power performance with different inlet air temperatures and humidity conditions. It is found that the actual power consumption and discharge flow are significantly influenced by the inlet air temperature as well as relative humidity. The results obtained during this study are compared both numerically and experimentally and are found to be in very good agreement.

Managerial Plan of Extended Operation of the Clean-Road System for the Improvement of the Urban Thermal Environment in Daegu (도시열환경개선을 위한 대구 클린 로드 시스템의 확대 운영방안에 관한 연구)

  • Jung, Eung-Ho;Rho, Paik-Ho;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.25 no.11
    • /
    • pp.1589-1595
    • /
    • 2016
  • From December 2014 to November 2015, an automatic weather system (AWS) was installed over a wide road of Daegu to continuously measure meteorological factors and surface temperature. We investigated the effective operating period of the clean-road system using the daily maximum and minimum air and asphalt surface temperatures, with the aim of creating an optimum thermal environment. The clean-road system was installed over a part of the broad way of Dalgubul(Dalgubul-Daero) by Daegu Metropolitan City in 2011. Until now, the clean-road system has been operated from the middle of April to the end of September. We assumed that it was desirable that the clean-road system could be operated when the discomfort index was above 55. In conformity with the conditions, we concluded that the optimum operation period of the clean-road system is from the end of March to about the middle of October.

Development of air supply system(Turbo blower) for 80kW PEM fuel cell (80kW급 고분자 전해질 연료전지의 공기공급계(터보 블로워) 개발)

  • Lee, Hee-Sub;Kim, Chang-Ho;Lee, Yong-Bok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.67-72
    • /
    • 2006
  • Blower as an air supply system is one of the most important BOP (Balance of Plant) system fur FCV(Fuel Cell Vehicle). For generating and blowing compressed air, the motor of air blower consumes maximum 25% of net power and fuel cell demands a clean air. Considering the efficiency of whole FCV, low friction lubrication of high speed rotor is needed. For the purpose of reducing electrical power and supplying clean air to Fuel cell, oil-free air foil bearings are applied at the each side of brushless motor (BLDC) as journal bearings which diameter is 50mm. The normal power of driving motor has 1.7kW with the 30,000rpm operating range and the flow rate of air has maximum 160 SCFM. The impeller of blower was adopted a mixed type of centrifugal and axial which has several advantages for variable operating condition. The performance of turbo-blower and parameters of air foil bearings was investigated analytically and experimentally. From this study, the performance of the blower was confirmed to be suitable far 80kw PEM FC.

  • PDF

A study on the design and construction of operating room (병원 수술실 설계 및 시공에 관한 연구)

  • Jung, Eul-Kyu;Oh, Jung-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.103-110
    • /
    • 2003
  • In the early 1990's the clean room system was a new trend of the operating room. This is the concept using in seminconductor plants. That is what the space around the operating table so clean as it remove contaminations with circulation of interior air. These articles describe the standard of interior construction and drawing details.

A Study on the Development of Oxygen Cluster Ion Generator for Sterilization of Bio Clean Room(BCR) (Bio Clean Room(BCR)의 멸균을 위한 산소 클러스터이온 발생 장치 개발에 관한 연구)

  • Park, Dong-Il;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • Bio Clean Room(BCR) and pharmaceutical product manufacturing facilities require careful assessment of many factors, including HVAC, controls, room finishes, process equipment, room operations, and utilities. Flow of equipment, personnel, and product must also be considered along with system flexibility, redundancy, and maintenance shutdown strategies. It is important to involve designers, operators, commissioning staff, quality control, maintenance, constructors, validation personnel, and the production representative during the conceptual stage of design. Critical variables for room environment and types of controls vary greatly with the clean space's intended purpose. It is particularly important to determine critical parameters with quality assurance to set limits and safety factors for temperature, humidity, room pressure, and other control requirements. In this paper, oxygen cluster ion equipment was utilized in order to enhance the indoor air quality and to prevent the airborne infection of ward in hospital. Moreover, the performance test of the equipment was also performed in order to develop the optimal sterilization system of BCR using the equipment.

초음파 세정 및 건조기술

  • 이강원;윤의중;김철호;이태범;이석태
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.05a
    • /
    • pp.118-122
    • /
    • 2004
  • 본 연구에서는 반도체 세정 챔버 내부에서 회전 척을 사용하는 기판의 세정 공정에서 세정장치와 건조장치를 분리하지 알고 일체화하는 기술을 연구하는 한편, 초음파 세정기술을 이용하여, 세정에 사용되는 약액을 절감하는 방법도 연구하였다. UWA(Ultrasonic Water and Clean Air) system은 초음파 진동부, 초순수 공급부 그리고 clean air공급부를 모듈화 하였다. UWA system으로 공급된 초순수에 70~130kHz범위의 초음파가 더하여지고 반도체 기판 위에 분사되면 기판 위의 미세 파티클을 세정하는 효과를 갖는다. 세정 후 연속적으로 clean air를 분사하여 기판 위의 수분을 완전히 제거한다. Particle 세정 작업을 실시한 후 표면을 검사하여 정밀세정 능력을 확인하였다.

  • PDF

A Study on Improvenment of Livingroom Smoke-control System using the FDS (화재 시뮬레이션(FDS)을 이용한 거실제연설비 개선에 관한 연구)

  • Kim, Mi-Seon;Baek, Eun-Seon
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.26-34
    • /
    • 2017
  • The purpose of this study is to identify and improve the performance of the adjacent room ventilation system in living room ventilation facilities, and compare and analyze the smoke control regulations of the NFPA code and the national fire safety standard (NFSC). The analysis method was fire dynamics simulation (FDS) and was used to analyze the, variations of the air supply amount, width of the boundary, change in indoor combustion and wind velocity of the incoming air. It was found to be advantageous to secure the clean layer when the amount of air supplied is less than the amount of discharged air in the fire room. However, in the supply room, it is more effective to secure the clean layer when the amount of supplied air is larger than the amount of discharged air, as a longer boundary width gives rise to better performance. In addition, it is necessary to consider the amount of air supplied and discharged as a function of the kind of flammable material. Moreover, decreasing the air inlet wind speed and amount of incoming air is advantageous for securing the clean layer of the fire room.