• Title/Summary/Keyword: Air change rate

Search Result 766, Processing Time 0.03 seconds

A study on the burn-in test to accomplish high quality cockpit air of an ultra-sonic aircraft in the early stage of production (생산 초기 초음속 항공기 조종석의 고품질 공기 확보를 위한 burn-in test 연구)

  • Shin, Jae Hyuk;Park, Sung Jae;Seo, Dong Yeon;Jeong, Suheon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.871-876
    • /
    • 2016
  • Abnormal odor similar with burning smell often appears at the cockpit in the beginning of ultra-sonic aircraft without air filter due to the heating of production materials remained at the bleed air duct. Sources of the odor should be removed by burn-in test before test flight in order to prevent pilot confuses order with emergency such as fire of engine. However, the present method cannot prevent abnormal odor completely at the high altitude flight because maximum temperature of flight is higher than it of burn-in-test. This paper suggests burn-in test improved based on the analysis of thermal conditions of high altitude flight. It is verified that the existing burn-in test cannot cover thermal conditions of high altitude flight due to the discontinuous flow control, high change rate of temperature per unit time and difference between limit temperature of condenser and turbine. In order to overcome the limitations of current methods, the new burn-in test with continuous flow control are suggested. The continuous flow control are achieved by ram air inlet control. The effect of suggested method are verified by ground tests and flight tests. The results show the bleed air temperature can cover the temperature of high altitude flight and prevent abnormal odor at the flight test.

Discussion on Optimal Shape for Wave Power Converter Using Oscillating Water Column (진동수주형 파력발전구조물의 최적형상에 대한 검토)

  • Lee, Kwang-Ho;Park, Jung-Hyun;Baek, Dong-Jin;Cho, Sung;Kim, Do-Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.5
    • /
    • pp.345-357
    • /
    • 2011
  • Recently, as part of diversifying energy sources and earth environmental issues, technology development of new renewable energy using wave energy is actively promoted and commercialized around Europe and Japan etc. In particular, OWC(Oscillating Water Column) wave power generation system using air flow induced by vertical movement of the water surface by waves in an air-chamber within caisson is known as the most efficient wave energy absorption device and therefore, is one of the wave power generation apparatus the closest to commercialization. This study examines air flow velocity, which operates turbine(Wells turbine) directly in oscillating water column type wave power generation structure from two-and three-dimensional numerical experiments and discusses optimal shape of oscillating water column type wave power generation structure by estimating the maximum flow rate of air according to change in shape. The three-dimensional numerical wave flume was applied in interpretation for this study which is the model for the immiscible two-phase flow based on the Navier-Stokes Equation. From this, it turned out that size of optimal shape appears differently according to the incident wave period and air flow is maximized at the period where minimum reflection ratio occurs.

Comparison of color and water extracts of Caragana sinica flowers dried at different air temperatures (열풍건조 온도를 달리한 골담초 꽃의 색과 추출물 특성)

  • Hye-Jung Choi;Kwang-Sup Youn;Hun-Sik Chung
    • Food Science and Preservation
    • /
    • v.30 no.5
    • /
    • pp.868-874
    • /
    • 2023
  • This study aimed to investigate the drying characteristics of Caragana sinica Rehder flowers, which are basic data necessary for increasing utilization. The flowers were harvested in mid-April and dried at different hot-air temperatures (50-90℃), and the physicochemical properties of the dried flowers were analyzed. It was found that the drying rate was proportional to the air temperature. The visual color of dried flowers was relatively strong in green when dried at 50℃, while browning was relatively severe when dried at 90℃. The greenness (-a* value) of the mechanical color of the powder decreased with increasing temperature, and the yellowness (b* value) decreased with increasing temperature above 70℃. The soluble solids of the hot water extract were maintained at a certain level after increasing up to 70℃, and the pH decreased with increasing temperature. The total polyphenol contents tended to increase with increasing temperature, and DPPH radical scavenging activity did not show a significant change after increasing up to 70℃. These results suggest that the hot-air drying temperature had a significant effect on the physicochemical characteristics of the C. sinica flower. The appropriate hot-air drying temperature was judged to be less than 50℃ for maintaining the unique color, and approximately 70℃ considering the high hot-water extraction yield and antioxidant capacity.

Climate Change Impacts on Optimum Ripening Periods of Rice Plant and Its Counter-Measure in Rice Cultivation (기후변화에 따른 벼 적정 등숙기간의 변동과 대책)

  • Yun Seong-Ho;Lee Jeong-Taek
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2000.11a
    • /
    • pp.28-45
    • /
    • 2000
  • It was unusual crop weather for 1998 and 1999 compared with normal in Korea. The consecutive days of the optimum ripening period for rice plant that had daily mean temperature 21-23C for 40 days after heading, increased with long anomalies in 1998-99. The air temperature during ripening period was much higher than the optimum temperature and lower sunshine hour than normal in the local adaptability tests of newly developed rice lines during those years. In response of rice cultivation to warming and cloudy weather during crop season, the yield shall be decreased. Most scientists agree that the rate of heating is accelerating and temperature change could become increasingly disruptive. Weather patterns should also become more erratic. Agrometeorologists could be analyzed yearly variations of temperature, sunshine hour and rainfall pattern focused on transient agroclimate change for last a decade. Rice agronomists could be established taking advantage of real time agricultural meteorology information system for fertilization, irrigation, pest control and harvest. Also they could be analyzed the characteristics of flowering response of the recommended and newly bred rice cultivars for suitable cropping plan such as cultural patterns and sowing or transplanting date. Rice breeders should be deeply considered introducing the characteristics of basic vegetative type of flowering response like Tonsil rices as prospective rice cultivars corresponding to global warming because of the rices needed higher temperature at ripening stage than Japonica rices, photoperiod sensitive and thermo-sensitive ecotypes

  • PDF

An Experimental Study on Flow Characteristics of Turbulent Pulsating Flow in a Curved Duct by using LDV (LDV에 의한 곡관덕트에서 난류맥동유동의 유동특성에 관한 실험적 연구)

  • Lee, Hong-Gu;Son, Hyun-Chul;Lee, Haeng-Nam;Park, Gil-Moon
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.397-403
    • /
    • 2000
  • In the present study, flow characteristics of turbulent pulsating flow in a square-sectional $180^{\circ}$ curved duct were experimentally investigated. Experimental studies for air flows were conducted to measure axial velocity and wall shear stress distributions and entrance length in a square-sectional $180^{\circ}$ curved duct by using the LDV with the data acquisition and the processing system. The experiment was conducted in seven sections from the inlet (${\phi}=0^{\circ}$) to the outlet (${\phi}=180^{\circ}$) at $30^{\circ}$ intervals of the duct. The results obtained from the experimentation were summarized as follows ; (1) When the ratio of velocity amplitude ($A_1$) was less than one, there was hardly any velocity change in the section except near the wall and any change in axial velocity distributions along the phase. When the ratio of velocity amplitude ($A_1$) was 0.6, the change rate of velocity was slow. (2) Wall shear stress distributions of turbulent pulsating flow were similar to those of turbulent steady flow. The value of the wall shear stress became minimum in the inner wall aid gradually increased toward the outer wall where it became maximum. (3) The entrance length of turbulent pulsating flow reached near the region of bend angle of $90^{\circ}$, like that of turbulent steady flow. The entrance length was changed by the dimensionless angular frequency (${\omega}^+$).

  • PDF

Performance analysis of an experimental plant factory

  • Ryu, Dong-Ki;Kang, Sin-Woo;Chung, Sun-Ok;Hong, Soon-Jung
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.395-403
    • /
    • 2013
  • Plant factory has drawn attention in many countries in the world due to capability of environmental control not only for better yield and quality, but also for increase in functional and medicinal components of the products. In this paper, an experimental plant factory was constructed for various tests under different environmental conditions, and the operations were evaluated. A production room was constructed with adiabatic materials with dimensions of $6,900{\times}3,000{\times}2,500$ mm ($L{\times}W{\times}H$). Four sets of $2,890{\times}600{\times}2,320$ mm ($L{\times}W{\times}H$) production frame unit, each with 9 light-installed beds and an aeroponic fertigation system, resulting in 36 beds, were prepared. Accuracy and response were evaluated for each environmental control component with and without crops. Air temperature, humidity, $CO_2$ concentration, light intensity, frequency, and duty ratio, fertigation rate and scheduling were controllable from a main control computer through wireless communication devices. When the plant factory was operated without crop condition, the response times were 8 minutes for change in temperature from 20 to $15^{\circ}C$ and 20 minutes from 15 to $20^{\circ}C$; 7 minutes for change in humidity from 40 to 65%; and 4 minutes for change in $CO_2$ concentration from 450 to 1000 ppm. When operated for 24 hours with crop cultivation; average, maximum, and minimum values of temperatures were 20.06, 20.8, and $18.8^{\circ}C$; humidity were 66.72, 69.37, and 63.73%; $CO_2$ concentrations were 1017, 1168, and 911 ppm, respectively. Photosynthetic Photon Flux Density was increased as the distance from the light source decreased, but variability was greater at shorter distances. Results of the study would provide useful information for efficient application of the plant factory and to investigate the optimum environment for crop growth through various experiments.

Ex situ acoustic target strength by tilt angle and pulsation of moon jellyfish (Aurelia aurita) using frequency 70 kHz (주파수 70 kHz를 이용한 보름달물해파리의 유영 자세각과 박동에 따른 초음파산란강도)

  • YOON, Eun-A;HWANG, Doo-Jin;HIROSE, Miyuki;SAWADA, Kouichi;FUKUDA, Yoshiaki;MUKAI, Tohru
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • Target strength (TS) information is an important parameter that estimates the detection, distribution, and abundance of Aurelia aurita. In order to investigate the biological TS of jellyfish, some factors such as size (bell diameter), tilt angle, pulsation, and symbion should be known. In the ex situ TS measurements, the tilt angles and pulsation from synchronized swimming behavior of four live A. aurita (bell diameters in the air: 54.2 ~ 94.2 mm) were measured with the acoustic data at 70 kHz. The reduced target strength (RTS) of A. aurita was found to change ranged from 13.4 ~ 16.5 dB according to the incidence angles from $-30^{\circ}$ to $24^{\circ}$. When the change rate of bell diameter in the water was 0.2, the TS value showed a 7.2 dB change. These results could be utilized as an important data to understand the acoustic characteristic scattering of A. aurita.

Comparison of the CO2 Emission Estimation Methods in a LNG Power Plant Based on the Mass Balance Approach (물질수지 방법을 고려한 액화천연가스 발전소에서의 온실기체 배출량 산정 방법 비교)

  • Kim, Hee-Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.235-244
    • /
    • 2013
  • Carbon dioxide emission estimation methods consist of four tiers according to the IPCC guideline. In this study, estimated results by tier 3 and tier 4 were compared with the theoretically calculated $CO_2$ emissions based on the mass balance approach for a gas fired power plant between March and May 2011. It was found that the relative differences were upto 17% between the measured emissions by tier 4 and theoretically estimated emissions, while the results of tier 3 were similar to those from theoretically estimated ones. The comparisons suggested the possibility of misestimation due to replacing missing, abnormal, or invalid data in continuous emissions monitoring system. When using only the data without those missing, abnormal, or invalid data, the relative differences decreased somewhat but still showed consistent differences depending on the stack. It is suggested that this differences might be due to the accuracy of the measurement instruments for the tier 4, especially, for the flow rate measurement instrument.

Evaluation on the Additional CO2 by Mobile Air Conditioning Systems of Korean Light-duty Vehicles (국내 소형자동차의 에어컨 가동에 따른 CO2 배출량 평가)

  • Park, Junhong;Lee, Jongtae;Kim, Sunmoon;Kim, Jeongsoo;Kang, Gunwoo
    • Journal of Climate Change Research
    • /
    • v.3 no.4
    • /
    • pp.259-270
    • /
    • 2012
  • Mobile air conditioning(MAC) systems of light-duty vehicles consume the most energy among auxiliary parts. Vehicle $CO_2$ reduction policies in Korea, US EPA and EU include the strategies to reduce additional $CO_2$ by MAC operation with providing incentive for the high-efficient MAC technologies. It is under development how to estimate MAC $CO_2$ and to differentiate advanced or high-efficient MAC system in US EPA and EU. The additional energy by MAC operation would beaffected by not only driving patterns but also environmental conditions such as temperature and humidity. In this study, we estimated MAC $CO_2$ of Korean light-duty vehicles with various driving cycles and environmental conditions. Test results were corrected to reference conditions for varied temperature and humidity during tests to get the comparable data for test vehicles. The test results showed that high-efficient MAC technologies have potential to reduce MAC $CO_2$ approximately by 50%. Considering the rate of MAC $CO_2$ to vehicle $CO_2$, it is expected that the introduction of high-efficient MAC technologies would considerably reduce vehicle $CO_2$ emission in MAC operation.

Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration (세라믹 막여과의 성능향상을 위한 응집 전처리의 적용)

  • Kang, Joon-Seok;Song, Jiyoung;Park, Seogyeong;Jeong, Ahyoung;Lee, Jeong-Jun;Seo, Inseok;Chae, Seonha;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.