• 제목/요약/키워드: Air change effectiveness

검색결과 78건 처리시간 0.029초

현장 적용 아이스슬러리 시스템의 열교환기 성능 실험 (The Heat Exchangers Performance Experiment for a Field Application Ice Slurry Cooling System)

  • 이상훈;유호선;이윤표
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1002-1007
    • /
    • 2009
  • The research are performed to check the characteristics of the ice slurry transport system for the district cooling. The system are installed at the 1st floored building which is as large as the $1204\;m^2$ ($86\;m{\times}14\;m$). Three kinds of heat exchanger are selected, such as, plate, spiral and shell & tube type, to apply to the ice slurry systems. Experiment was done in the two cases. The first case, circulation water flow fixed at the design conditions for the state to change the flow of the supply of ice slurry. The second case, Ice slurry flow fixed at the design conditions for the state to change the flow of circulation water. Both side of Energy balance was calculated. The performance of plate heat exchanger is higher than others and it's enthalpy effectiveness is higher too.

  • PDF

군작전 효율화를 위한 셀룰라망 연동구조 설계 (An Architecture Design of Military Operation System Utilizing Cellular Networks)

  • 김재철;김인택;박종범;정창욱
    • 한국군사과학기술학회지
    • /
    • 제14권1호
    • /
    • pp.74-83
    • /
    • 2011
  • In this paper, we propose an architecture design of military operation system utilizing cellular networks. The main contribution of this paper is to provide a cost-effective military operation solution for ground forces, which is based on IT(information technology). By employing the cellular phones of officers' and non-commissioned officers' as the tools of operational communication, the proposed system can be constructed in the minimum duration and be built on the four components: command and control system, gateway, security system, and terminal(cell phone). This system is most effective for the warfare of limited area, but the effectiveness does not decrease under the total war covering the whole land of Korea. For the environmental change of near future, expanded architecture is also provided to utilize the functionalities of smart phones.

군작전 효율화를 위한 셀룰라망 연동구조 설계 (An Architecture Design of Military Operation System Utilizing Cellular Networks)

  • 김재철;김인택
    • 안보군사학연구
    • /
    • 통권9호
    • /
    • pp.257-282
    • /
    • 2011
  • In this paper, we propose an architecture design of military operation system utilizing cellular networks. The main contribution of this paper is to provide a cost-effective military operation solution for ground forces, which is based on IT(information technology). By employing the cellular phones of officers' and non-commissioned officers' as the tools of operational communication, the proposed system can be constructed in the minimum duration and be built on the four components: command and control system, gateway, security system, and terminal(cell phone). This system is most effective for the warfare of limited area, but the effectiveness does not decrease under the total war covering the whole land of Korea. For the environmental change of near future, expanded architecture is also provided to utilize the functionalities of smart phones.

  • PDF

모터의 특성을 고려한 CFD 해석에 의한 축류홴 성능해석 (ANALYSIS ON CHARACTERISTICS OF AN AXIAL FLOW FAN THROUGH CFD ANALYSIS INCORPORATED WITH MOTOR CHARACTERISTICS)

  • 김주한;허남건;김욱
    • 한국전산유체공학회지
    • /
    • 제15권4호
    • /
    • pp.109-114
    • /
    • 2010
  • In a fan design, CFD analysis, which is very useful for mechanical design relating to the heat and fluid dynamics, is one of the most popular tools. However, since the CFD analysis is conventionally carried out with the constant fan speed condition, the speed change, induced by the air flow rate and motor characteristics, is hardly modeled. And, consequently, the remarkable difference exist between analysis and experimental results. In this paper, we has proposed a method of setting the varying fan speed as a boundary condition considering air flow rate and motor torque-speed characteristics. The effectiveness of the proposed method is verified by comparison with experimental results.

기포 캐비테이션의 거동 해석 및 수중익 캐비테이션의 소음 제어 (Analysis of bubble cavitation and control of cavitation noise of hydrofoils)

  • 강관형;안종우;송인행;김기섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.335-341
    • /
    • 2001
  • The bubble cavitation and cloud cavitation are the major sources of cavitation-induced sound and vibration. A numerical method which predicts the trajectory and volume change of a cavity is developed, to predict the cavitation noise of a body. It is shown, by using the numerical method, that the cavitation inception and events rate is strongly dependent on the screening effect caused by the pressure gradient around a body, which is confirmed experimentally. Additionally, the effectiveness of a cavitation control method utilizing air injection is investigated experimentally. It is demonstrated that the noise level of the cloud cavitation can be significantly reduced by the air-injection method.

  • PDF

공동주택에서 각 실 문의 개폐에 따른 환기 특성 연구 (A Study on the Effect of Open and Closed Room Doors on Apartment Ventilation Characteristics)

  • 최임규;김영일;정광섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.469-474
    • /
    • 2008
  • The objective of this study is to propose basic design guidelines for more effective air ventilation system in apartments. It is well known that ventilation depends on whether the room doors are open or closed as well as people's living patterns. This study considers 84 ㎡-sized apartment which has extended living room without balcony. Ventilation of bathroom and kitchen is not considered. The height of the building, external air pressure and air infiltration through the windows are also neglected. The regulation on indoor air quality made it mandatory that the air change per hour be more than 0.7. Four models are suggested to study the effect of open and closed doors. Models 1 and 3 are open door types and models 2 and 4 are closed door types. The open types have 50 mm hole near the top of the door to substitute exhaust outlet. The ventilation effectiveness was evaluated by 3-dimensional numerical simulation using finite volume method by a commercial software. This work compares air flow, temperature of air, age of air and the efficiency of ventilation of apartments with wooden doors of bedroom 1 and 2, which are open or closed.

  • PDF

폐음향 경계조건을 갖는 가스터빈 연소기의 연소불안정 해석 (A Combustion Instability Analysis of a Gas Turbine Combustor Having Closed Acoustic Boundaries at Both Ends)

  • 차동진;신동명
    • 설비공학논문집
    • /
    • 제22권3호
    • /
    • pp.156-164
    • /
    • 2010
  • Combustion instability is a major issue in design of gas turbine combustors for efficient operation with low emissions. Combustion instability is induced by the interaction of the unsteady heat release of the combustion process and the change in the acoustic pressure in the combustion chamber. In an effort to develop a technique to predict self-excited combustion instability of gas turbine combustors, a new stability analysis method based on the transfer matrix method is developed. The method views the combustion system as a one-dimensional acoustic system with a side branch and describes the heat source as the input to the system. This approach makes it possible to use not only the advantages of the transfer matrix method but also well established classic control theories. The approach is applied to a gas turbine combustion system, which shows the validity and effectiveness of the approach.

유동 방향이 간접 증발식 냉각기 성능에 미치는 영향 (Effects of flow direction on the performance of an indirect evaporative cooler)

  • 추현선;이관수;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.743-748
    • /
    • 2006
  • Ren et al. analyzed the performance of the indirect evaporative cooler according to the direction of the flow considering evaporation water flow and wetness. However the effect of NTU of each channel on the performance of the indirect evaporative cooler according to the direction of the flow was not analyzed exactly. In this study the effect of the direction of the flow on the Indirect evaporative cooling performance changing NTU of each channel are investigated theoretically. The cooling process of the indirect evaporative cooler by flow direction is modeled into a set of linear differential equations and solved to obtain the exact solutions to the temperatures of the hot fluid, the moist air, and evaporation water. Based on the exact solution in the case of different NTU of each channel, we study the change of the distribution of the temperature according to each flow direction and at the same time analyze the effect of the flow direction on the cooling performance.

  • PDF

저비용항공 진입에 따른 항공과 고속철도수단 선택에 관한 연구 (A study on Air and High Speed Rail modal According to the Introduction of Low Cost Carrier Air Service)

  • 임삼진;임강원;이영인;김경희
    • 대한교통학회지
    • /
    • 제26권4호
    • /
    • pp.51-61
    • /
    • 2008
  • 2004년을 기준으로 전국 15개 지방공항 가운데 제주와 김포, 김해공항을 제외한 나머지 공항 들은 해마다 수십억 원의 적자를 내고 있는 실정이다. 지방공항들의 실패원인으로 수요예측 오류의 문제가 대두되어 왔다. 이에 소형 항공기를 이용해 정기서비스를 제공하는 저비용항공의 진입을 통해 소비자의 편의를 증진시키고 지방공항을 활성화해야 한다는 주장이 사회적인 공감을 얻고 있다. 따라서, 본 연구에서는 (1) 기존항공과 고속철도와 저비용항공 3자 사이의 고속교통통행수단 선택모형을 제시하고 (2) SP조사를 통하여 서울-대구간 저비용항공의 이용수요를 추정하고, (3) 추정모형을 설정하여 정책수단별 효과 분석을 실시하였다. 분석 결과, (1)서울-대구간 고속교통수단 선택에 있어서 저비용항공의 진입은 요금과 가격이 유의미한 영향을 미치는 것으로 나타났으며, (2)저비용항공의 요금이 KTX에 비해 훨씬 저렴한 38,000원 수준으로 정해질 경우에도 총통행시간이 KTX와 시간이 동일하게 소요되는 지역의 경우 저비용항공의 선택확률은 0.1 정도로 작게 나타나 통행수단 전환효과는 그리 크지 않을 것으로 분석되었다. (3)향후 서울-대구간 저비용항공 취항시의 요금은 38,000원${\sim}$44,000원 사이에서 결정되어야 할 것으로 보이며, 그 이상의 요금으로 결정될 경우 큰 수요를 기대하기 어려울 것으로 판단된다.

대향류 핀삽입형 재생증발식 냉방기의 냉방성능 (Cooling Performance of a Counterflow Regenerative Evaporative Cooler with Finned Channels)

  • 문현기;이대영
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.462-469
    • /
    • 2008
  • A regenerative evaporative cooler has been fabricated and tested for the evaluation of cooling performance. The regenerative evaporative cooler is a kind of indirect evaporative cooler comprised of multiple pairs of dry and wet channels. The air flowing through the dry channels is cooled without any change in the humidity and at the outlet of the dry channel a part of air is redirected to the wet channel where the evaporative cooling takes place. The regenerative evaporative cooler fabricated in this study consists of the multiple pairs of finned channels in counterflow arrangement. The fins and heat transfer plates were made of aluminum and brazed for good thermal connection. Thin porous layer coating was applied to the internal surface of the wet channel to improve surface wettability. The regenerative evaporative cooler was placed in a climate chamber and tested at various operation condition. The cooling performance is found greatly influenced by the evaporation water flow rate. To improve the cooling performance, the evaporation water flow rate needs to be minimized as far as the even distribution of the evaporation water is secured. At the inlet condition of $32^{\circ}C$ and 50%RH, the outlet temperature was measured at $22^{\circ}C$ which is well below the inlet wet-bulb temperature of $23.7^{\circ}C$.