• 제목/요약/키워드: Air buffer

검색결과 94건 처리시간 0.026초

Pseudomonas carboxydohydrogena에 의한 일산화탄소의 산화 (Oxidation of Carbon Monoxide by Pseudomonas carboxydohydrogena)

  • 김영민
    • 미생물학회지
    • /
    • 제21권1호
    • /
    • pp.27-35
    • /
    • 1983
  • The stoichiometry between the consumption of CO and $O_2$ and the production of $CO_2(2CO+O_2{\rightarrow}2CO_2)$) showed that Pseudomonas carboxydohydrogena grows as a typical aerobic CO oxidizer with CO. The optimal concentration of CO for growth was found to be 30% in gas mixture with air. The initial buffer concentration of the culture medium did not affect the growth of this bacterium. P. carboxydohydrogena is an obligate aerobe and dose not use nitrate as a terminal electron acceptor. The CO dehydrogenase is an inducible and soluble enzyme. The reaction rate and stability were maximal at pH7.5, and the Arrhenius plot revealed an activation energy of 37.7kJ/mol (9.0 Kcal/mol). The crude enzyme used methylene blue, thionin, and toluylene blue as electron acceptors for the oxidation of CO to $Co_2$ under anaerobic conditions. It was found that water must be the source of the second oxygen atom for CO oxidation.

  • PDF

Fabrication and Evaluation of a New High-Temperature pH Sensor for Use in PWR Nuclear Power Plants

  • Jung, Yong-Ju;Yeon, Jei-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권10호
    • /
    • pp.2939-2942
    • /
    • 2010
  • A new high-temperature pH sensor has been successfully developed by reforming the internal reference systems of the pH sensors based on oxygen-ion conducting ceramic membrane. The conventional internal reference system, a mixture of Ni and NiO, has been replaced with partially oxidized Ni powders, where Ni and NiO coexist on the surface of particles, in order to avoid the cumbersome mixing step of Ni and NiO particles. The partially oxidized Ni particles were made by oxidizing Ni under air atmosphere at $600^{\circ}C$ and characterized by X-ray diffraction (XRD) and FTIR spectroscopy. The viability of the pH sensor developed was assessed in boric acid (1000 ppm-B)/ lithium hydroxide (1 to 3 ppm-Li) buffer solutions at $280^{\circ}C$. The pH sensor showed excellent accuracy with a small error less than ${\pm}0.2$ pH units.

저에너지주택의 지열히트펌프시스템 냉·난방 성능분석 (Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House)

  • 백남춘;김성범;신우철
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.387-393
    • /
    • 2016
  • A ground source heat pump system maintains a constant efficiency due to its stable heat source and radiant heat temperature which provide a more effective thermal performance than that of the air source heat pump system. As an eco-friendly renewable energy source, it can reduce electric power and carbon dioxide. In this study, we analyzed one year of data from a web based remote monitoring system to estimate the thermal performance of GSHP with the capacity of 3RT, which is installed in a low energy house located in Daejeon, Korea. This GSHP system is a hybrid system connected to a solar hot water system. Cold and hot water stored in a buffer tank is supplied to six ceiling cassette type fan coil units and a floor panel heating system installed in each room. The results are as follows. First, the GSHP system was operated for ten minutes intermittently in summer in order to decrease the heat load caused by super-insulation. Second, the energy consumption in winter where the system was operated throughout the entire day was 7.5 times higher than that in summer. Moreover, the annual COP of the heating and cooling system was 4.1 in summer and 4.2 in winter, showing little difference. Third, the outlet temperature of the ground heat exchanger in winter decreased from $13^{\circ}C$ in November to $9^{\circ}C$ in February, while that in summer increased from $14^{\circ}C$ to $17^{\circ}C$ showing that the temperature change in winter is greater than that in summer.

Clean Stocker내 새로운 방식의 기류제어에 관한 해석 (Analysis of New Air Control System in Clean Stocker)

  • 최기한;한창우;이상룡
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.121-130
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. Since an important function of a stocker is to keep the contained material clean. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker, The airflow across the product prevent contamination from settling on the product. Up to now, stocker typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, In order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. Open ratios of exits need to be optimized for the same quantities of airflow in each exit. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and Blue Ridge Numerics FEM software, CFDesign, was used fur simulating airflow in stocker. As a result, Open ratios of exits important to provide constant clean airflow can be obtained by the analysis of static pressure regain and was verified by simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

풍혈의 환경 특성과 식물지리적 가치 (Environmental Characteristics of Wind-Hole and Phytogeographical Values)

  • 공우석;이슬기;윤광희;박희나
    • 환경영향평가
    • /
    • 제20권3호
    • /
    • pp.381-395
    • /
    • 2011
  • Present work aims to establish an integrated management system of environmental data base for nine typical wind holes or air holes in Korea. It basically deals with definition, geographical distribution, morphological pattern, physical characteristics and anthropogenic environments of wind hole to propose systematic preservation strategy of their periglacial landscape and flora, which are known to be sensitive to global warming. Wind hole, in which cool air blows out during the summer, but mild air comes out during the winter from a cave or hole, is frequently found on northwest- and north-facing slopes on the terminal point of steep talus, block field, and block stream, and can be categorized into three types, i.e., talus, cave and sink types. Environmental characteristics of nine wind holes are analyzed on the basis of their geology, landform, climate, soil, hydrology, vegetation, road, footpath, land-use, and management system, and relevant DB are prepared. Wind hole areas with unique landscape and ecological values need to be designated as a nature reserve, and zoning of core, buffer, and transitional zones are required for the multi-dimensional preservation of periglacial landscape and ecosystem. Phytogeographical values of glacial relict plants, including mountain cranberry(Vaccinium vitis-idaea) at its global southernmost limit at Bangnaeri wind hole, Hongchon County, Gangwon Province of Korea are discussed in detail as a floristic refugia in connection with climate change during the Pleistocene Epoch and potential in-situ and ex-situ preservation sites in the future.

혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구 (An Experimental Study of The J-T Cryocooler with Mixed Refrigerant)

  • 이경수;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권1호
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

제어 방식에 따른 지열 히트펌프 시스템의 성능 시뮬레이션 (Performance Simulation of Geothermal Heat Pump (GHP) System with Different Control Schemes)

  • 이두영;최재호;민경천;손병후
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.35-41
    • /
    • 2016
  • 지열 히트펌프 시스템에서 히트펌프 등 시스템 구성 요소의 에너지 소비량을 효율적으로 관리하면, 냉난방 성능을 더 높일 수 있다. 본 논문은 외기온도 제어 방식이 지열 시스템의 성능에 미치는 영향을 분석하였다. 또한 분석 결과를 현재 국내에서 주로 적용하는 제어 방식(Control-A)과 비교하였다. 이를 위해 상용 소프트웨어(TRNSYS 17)를 이용하여 가상 지열 시스템의 모델을 구축한 후, 시뮬레이션을 수행하였다. 외기 온도 제어 방식(Control-B)은 버퍼 탱크의 온도를 외기 온도에 따라 제어하기 때문에, 간절기 때 효과적이었다. 기존 제어 방식과 비교했을 때, 외기 온도 제어 방식은 히트펌프 전력 소비량을 7.7%(147 kWh 절감) 그리고 순환펌프 전력 소비량을 7.5%(28.1 kWh 절감) 줄일 수 있었다.

18세기 이후 조선사회의 온돌에 대한 인식변화와 난방효율 증대를 위한 건축적 모색 (A Change of Awareness on the Ondol System and Architectural Seeking for Increasing Heating Efficiency since the 18th Century Joseon Society)

  • 정정남
    • 건축역사연구
    • /
    • 제27권3호
    • /
    • pp.15-26
    • /
    • 2018
  • As a result of reviewing various documents and existing researches, since the late Goryeo period, the most active period in the Ondol(溫突, Korean floor heating system) facilities is the 17th century. The phenomenological reason was recovering the buildings destroyed by the Japanese Invasion of Korea in 1592(壬辰倭亂) & the Manchu War of 1636(丙子胡亂), but the underlying cause was an abnormal climate in which a pair of summer and winter cold continued. In the 17th century, as the Ondol facilities grew rapidly without distinction between regions and classes, the supply and demand of fuel caused economic and natural environmental problems. And a negative and positive view on Ondol was suggested. Since the middle of the 18th century, when the demand and supply of Ondol reached its peak, which could no longer increase, a new awareness of Ondol began to grow. The room was called the Panbang(板房) and the Ondol, depending on the material that made up the floor. It was considered natural to have the Ondol from this time on. The Incan(因間) and Jo(竈) that were made to burn were started to be recorded as a kitchen, regardless of size and function. Changes in social awareness of Ondol have led to concerns about heating efficiency. A variety of architectural explorations were conducted. Such a search was later realized in concrete architectural form. There is a double Ondoll structure, and the column spacing is reduced compared to the previous one. The heat buffer space is formed around the Ondol room, and the double window can control the light and the air going in and out.

겔-스폰지 혼용 시스템에 고정화된 세포를 통한 질산염의 연속적 분해 (Continuous Nitrate Reduction by Gel and Foam Matrix (GFM) Immobilized Cells)

  • 조양희;함태식
    • 한국식품과학회지
    • /
    • 제30권4호
    • /
    • pp.902-907
    • /
    • 1998
  • 본 연구에서는 세포 고정화를 위해 기존의 고정화 방법의 단점을 보완하기 위하여 새롭게 개발된 GFM 시스템에 Paracoccus denitrificans를 고정화하여 물속의 nitrate를 분해하는데 적용하였다. 고정화 조건으로써 스폰지 구멍의 크기 20 P.P.I. (pore per inch)와 겔로서 alginate가 이미 최적의 조건으로서 선택되었다. 고정화 세포의 연속 nitrate 분해능력을 air-lift reactor내에서 측정한 결과, 물속의 nitrate함량이 증가함에 따라 분해능력이 증가함을 나타내었다. 또한 연속운전에서 본 시스템은 기존의 고정화시스템인 bead 겔포괄법과 비교할 때 $1.2{\sim}2.1$배 정도 분해능력이 향상되었다. 최고 nitrate 분해속도는 buffer를 함유한 medium에 있어서 177 mg/L h이었으나 buffer를 첨가하지 않은 경우에 있어서는 33 mg/L h이었다. 또한 저장안정성을 측정한 결과, $5^{\circ}C$에 저장하였을 때 분해능력은 16주간 거의 변화가 없었으며 고정화하지 않은 자유세포나 bead에 고정화된 세포에 비하여 저장안정성이 두드러지게 뛰어났음을 알 수 있었다.

  • PDF

북한 공역의 통일 후 지위 (The Status of North Korean Airspace after Reunification)

  • 권창영
    • 항공우주정책ㆍ법학회지
    • /
    • 제32권1호
    • /
    • pp.287-325
    • /
    • 2017
  • 20세기 이후 항공우주 군사과학기술의 발달과정에 비추어 보면, 국가의 존립과 번영을 위해서 하늘은 매우 중요하다. "하늘을 지배하는 자, 세계를 지배한다!"는 격언이 제공권(制空權)의 필요성을 강조하고 있다. 이 글은 남북의 통일 과정과 통일 이후 공역(空域, airspace)의 지위에 관한 최초의 연구로서, 이를 요약하면 다음과 같다. 첫째, 영공(領空)은 영토와 영해의 상공으로 국경선과 영해선에 의하여 그 수평적 범위가 결정된다. 국경문제에 관하여 역사적 진실규명을 통한 재조정의 시도보다는 현질서의 수용이 가장 합리적이고, 통일전후과정에서 인접 국가의 지지를 받을 수 있으며, 동북아 평화를 위해서 통일한국은 북한과 중국 러시아 사이의 기존 국경협정을 그대로 존중할 필요가 있다. 그러나 현재 북한이 동해 황해에 설정한 직선기선은 국제법상 직선기선이 적용될 수 있는 사정을 갖추지 못하였기 때문에 이를 폐기하고, 통일한국은 국제법에 부합하는 기선을 다시 정하여 그 바깥쪽 12해리의 선까지에 이르는 수역을 영해로 결정하는 것이 바람직하다. 둘째, 비행정보구역(Flight Information Region)은 항공기의 안전하고 효율적인 비행과 항공기의 수색 구조에 필요한 정보를 제공하기 위하여 국제민간항공기구(ICAO)에서 획정한 구역이므로 국제법상 효력이 있다. 현재 한반도 일대에는 남한이 관할하는 인천 FIR과 북한이 관할하는 평양 FIR로 나누어져 있다. 급변사태가 발생하여 북한에서 일시적으로 평양 FIR의 관제권을 행사할 수 없는 경우에는 원칙적으로 남한이 평양 FIR의 관제권을 행사하고, 부득이한 경우에는 ICAO가 일시적으로 이를 행사하는 것이 바람직하다. 통일한국에서는 FIR의 체계적 관리와 통제, 항로개설 관리의 효율성 등을 감안하여, ICAO의 승인을 얻어 평양 FIR을 폐지하고 인천 FIR로 통합하여 운용하는 것이 바람직하다. 셋째, 방공식별구역(Air Defense Identification Zone)은 국가안전보장 목적상항공기의 용이한 식별, 위치 확인 및 통제가 요구되는 공역으로서, 해당 국가가 일방적으로 설정한다. 미국은 1951. 3. 22. 전시포고령에 의하여 한국방공식별구역(KADIZ)을 일방적으로 설정하였는데, 국방부는 2013. 12. 8. 이어도 상공을 포함하는 지역까지 확장한 새로운 KADIZ를 선포하였다. 현재 북한의 군사경계수역은 동해 황해 등 해상경계선으로만 설정되어 있는 점, 중국 러시아와의 관계에서 ADIZ로서 기능을 수행하기에 부족한 점에 비추어 보면, 통일한국이 이를 승계할 의무는 없다. 한반도의 경우에는 종심(縱深)이 짧기 때문에 영공보다 외곽에 ADIZ 경계선을 설정하여야 ADIZ 본래 목적을 달성할 수 있으므로, 통일한국의 인천 FIR과 일치하는 경계선으로 통일한국의 KADIZ를 새로 설정하여 이를 선포하는 것이 타당하다. 다만, 인접국가의 ADIZ와 중첩되거나 경계선을 같이하여 완충지역이 존재하지 않는 경우에는 군사적 긴장감이 고조될 수 있으므로, 동북아 평화를 위해서는 상호간 협상을 통하여 해상에서는 인접국가의 ADIZ 사이에 완충공간을 설정하는 것이 바람직하다.

  • PDF