• 제목/요약/키워드: Air Volume Concentration

검색결과 356건 처리시간 0.024초

공기/연료분무 혼합기의 점화 및 화염전파 해석 (Numerical Analysis of Ignition and Flame Propagation in the Air/Fuel Spray Mixture)

  • 김용모;김성준
    • 대한기계학회논문집
    • /
    • 제19권12호
    • /
    • pp.3352-3359
    • /
    • 1995
  • An Eulerian-Lagrangian method is employed to simulate the ignition process and the flame propagation through the air/fuel spray mixture in a closed constant-volume combustor. The spray mixture is ignited by providing a hot wall at the end of the combustor or by firing the electric spark. The investigated parameters involve the initial droplet size, overall equivalence ratio, initial fuel vapor concentration, distance between the hot wall and the nearest droplet, and the ignition energy. Numerical results clearly show the existence of the optimum spray condition for minimizing the ignition energy and the ignition delay time as well as the critical dependence of ignition upon the distance of the heat source to the nearest droplet.

공단지역에서 대기중 총 부유분진의 입자크기 분포와 화학적 성분에 관한 분석과 연구 (A Study on the Size Distribution and Chemical Composition of total Suspended Particulates at Industrial Region)

  • 박흥재;이성욱;박원우
    • 한국환경과학회지
    • /
    • 제2권3호
    • /
    • pp.201-206
    • /
    • 1993
  • The concentration of Total Suspended Particulates(T.S.P), size distribution of suspended particulates, and soluble anions of T.S.P in atmosphere of industrial region in Busan were investigated. T.S.P was measured by High-Volume Air Sampler and particle size distribution was measured by Anderson Air Sampler. We analyzed the chemical component of the T.S.P by ion Chromatography and measure4 the shape and size of T.S.P by Scanning Electron Micrography The small size of T.S.P mainly exist in industrial region, but the large size of T.S.P mainly exist in residentail area.

  • PDF

저용량 PM2.5 도입부 개발 및 성능평가 (Design and Performance Evaluation of Low-Volume PM2.5 Inlet)

  • Kim Dae-Seong;Hong Sang-Beom;Lee Jae-Hun;Lee Gyu-Won
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.251-252
    • /
    • 2003
  • Most particles capable of reaching the thoracic region of humans are in the size range below 10$\mu$m in diameter. Particles with a diameter smaller than 2.5 $\mu$m are deposited in large amounts in the alveolar region during mouth inhalation. The hazard caused by fine particles depends on their chemical composition and the site within the human respiratory system where they are deposited(Hinds, 1982). Therefore, the concentration of air borne fine particles is an important parameter for the evaluation of the degree of hazard in an atmospheric environment. (omitted)

  • PDF

황사현상시 서울지역 대기분진의 성분에 관한 연구 (A Study on the Metal Ion Components of Airborn Particulates during Yellow Sand Phenomena in Seoul)

  • 신찬기;박태술;김윤신
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.47-62
    • /
    • 1991
  • Yellow Sand Phenomena was observed from April 8 th to 10 th in 1990. During this period particle was collected to investigate the chacteristics of chemical composition of particulate by High Volume Air Sampler and Andersen Air Sa~npler in Seoul. During this period the particle concentration was 350 yg/$m^3$ and the anions, cations, and metal concentrations were increased and the orders of these were $S0_4\;^{-2}>N0_3\;^->Cl^->F^-, Na^+>Ca^{+2}>NH_4\;^+>Mg^{2+}>K^+$, and Fe>Al>Si>Zn>Pb respectively. The principal source of Yellow Sand were identified soil and sea salt. Mn used by the trace element of soil, the persentage of contribution from soil was calculated to be about 81.3% for the particle increased by Yellow Sand Phenomena. Also the principal chemical compounds of particle were estimate metals(Fe, Al, Si, Zn) oxides, $CaSO_4, NaSO_4, MgSO_4, NaC1, MgCl_2$ and $(NH_4)_2SO_4$.

  • PDF

대전 1,2 공단지역의 독성 금속의 확률론적 농도 (Probabilistic Concentration Estimates of Toxic Metals in Taejon 1,2 Industrial Complex)

  • 장미숙;임종명;구부미;이진홍
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 춘계학술대회 논문집
    • /
    • pp.251-253
    • /
    • 2000
  • 본 연구는 대전 1,2 공단 지역을 대상으로 발암 금속 6종(As Be, Cd, Cr, Ni 및 Pb)을 포함한 15종의 독성 금속을 선정하여 유도결합 플라스마 분광법(ICP-MS)을 이용하여 3년간 분석하고 이 농도 자료에 근거하여 각 금속의 확률론적 농도를 평가하고자 한다. 대기중 부유분진은 대전시 대화동(대전 1,2 공단내 대화동 동사무소 건물 옥상)에 high-volume air sampler(Graseby Andersen : SAUB-10H Model, USA)를 약 0.85$\textrm{m}^3$/min으로 운전하여 시료당 공기량이 약 1,200 $\textrm{m}^3$가 유지되도록 포집하였다. (중략)

  • PDF

대향류 에틸렌/공기 비예혼합 화염의 구조 및 Soot 생성 메커니즘 해석 (Numerical Analysis for the Detailed Structure and the Soot Formation Mechanism in Counterflow Ethylene-Air Nonpremixed Flame)

  • 임효준;김후중;김용모
    • 한국자동차공학회논문집
    • /
    • 제7권5호
    • /
    • pp.40-54
    • /
    • 1999
  • The flame structure and soot formation in the counterflow Ethylene-Air nonpremixed flame are numerically analyzed. The present soot reaction mechanism involves nucleation, surface growth, particle coagulation, and oxidation steps. The gas phase chemistry and the soot nucleation, surface growth reactions are coupled by assuming that the nucleation and soot mass growth has the certain relationship with the concentration of benzene and acetylene. In terms of the centerline velocity and the soot volume fraction, the predicted results are compared with the experimental data. The detailed discussion has been made for the sensitivity of model constants and the deficiencies of the present model. Numerical results indicated that the acetylene addition to the soot surface plays the dominant role in the soot mass growth for the counterflow nonpremixed flame.

  • PDF

울산광역시 초등학교 실내공기오염물질의 환경적 특성에 따른 농도 분석 (Analysis of Indoor Air Pollutants from Elementary School Classrooms with Different Environment in Ulsan, Korea)

  • 이치현;이병규;김양호;이지호;오인보
    • 한국대기환경학회지
    • /
    • 제27권1호
    • /
    • pp.97-116
    • /
    • 2011
  • This study analyzed indoor air pollutants from elementary school with different environment. Air sampling and measurement were carried out from classrooms and hallways from three target elementary schools in the fall and winter seasons. The winter average concentrations of $PM_{10}$, $CO_2$, CO, aldehydes and ketones, and benzene were higher than the fall ones. The fall average concentrations of $O_3$ and $NO_2$ were higher than the winter ones. The concentrations of $PM_{10}$ and $CO_2$ at the schools near the heavy traffic areas and having poor ventilation were higher than those from the other elementary school. The average concentration of CO at the school having heavy traffic volume was highest. The concentrations of $O_3$, $NO_2$, aldehydes and ketones, and VOCs at the school near the shipbuilding industries were highest among the three elementary schools.

Determining Potassium Bromate in the Inhalable Aerosol Fraction in Workplace Air with Ion Chromatography

  • Kowalska, Joanna;Lis, Monika;Biesaga, Magdalena
    • Safety and Health at Work
    • /
    • 제12권2호
    • /
    • pp.209-216
    • /
    • 2021
  • Background: The article presents the results of studies performed in order to develop a new method of airborne potassium bromate(V) determination at workplaces. Methods: The method is based on a collection of the inhalable fraction of potassium bromate(V) using the IOM Sampler, then extraction of bromates with deionized water and chromatographic analysis of the obtained solution. The analysis was performed using ion chromatography with conductometric detection. The tests were performed on a Dionex IonPac®AS22 analytic column (250 × 4 mm, 6 ㎛) with AG22 precolumn (50 × 4 mm 11 ㎛). Results: The method provides for potassium bromate(V) determination within the concentration range of 0.043 ÷ 0.88 mg/m3 for an air sample of 0.72 m3 in volume, i.e., 0.1-2 times the exposure limit value as proposed in Poland. The method was validated in accordance with PN-EN 482. The obtained validation data are as follows: measuring range: 3.1-63.4 ㎍/mL, limit of detection (LOD) = 0.018 ㎍/mL and limit of quantification (LOQ) = 0.053 ㎍/mL. The developed method has been tested in the work environment, on laboratory employees having contact with potassium bromate(V). Conclusion: The analytical method allowed the determination of the inhalable fraction of airborne potassium bromate(V) at workplaces and can be used to assess occupational exposure.

메탄올-디젤기관의 스모크 저감에 관한 연구 (A Study on the Smoke Reduction of Methanol-Diesel Engine)

  • 한성빈;문성수
    • 대한기계학회논문집B
    • /
    • 제20권7호
    • /
    • pp.2421-2429
    • /
    • 1996
  • The objective of this research is to apply effect of the pre-mixed combustion quantity and smoke emission in diesel engine. According as air fuel ratio is increased, emission of smoke concentration is linearly reduced. As Injection timing is advanced, smoke concentration is remarkably reduced. It is considered to be the primary cause of the increase in the premixed combustible mixture during long ignition delay period with advancing injection timing. Smoke is increased with increasing engine speed, so it is considered to be the primary cause of the increase of the mass of fuel injected. Smoke is decreased according to the increase of methanol volume ratio. It is considered that the primary cause of the increase in the quantity of pre-mixed combustion.

도시대기 중에 부유하는 미세입자중 음이온의 농도분포 특성 (Characteristics of Anion Concentration Distributions in Airbone Fine Particles in Urban Atmosphere)

  • 천만영;조기철;여현구
    • 한국대기환경학회지
    • /
    • 제13권1호
    • /
    • pp.1-7
    • /
    • 1997
  • Anion concentrations and distributions of airborne fine particles less than 2 $\mu$m in urban atmosphere were determined from Feb. 5 to 16, 1996. The sampling was carried out using 8 stages Hering's low pressure impactor (LPI, aerodynamic cutoff diameters are 0.05, 0.075, 0.11, 0.26, 0.50, 1.0, 2.0, and 4.0$\mu$m) on the top of a five-story building located at Kon-Kuk university in Seoul. Average concentrations if C $l^{[-10]}$ , N $O_3$$^{[-10]}$ and S $O_4$$^{2-}$ were 9.4, 8.4, and 14.5 $\mu\textrm{g}$/㎥, respectively. The distributions of these anion concentrations were bimodal types which showed two peaks in the range of 0.075~0.12 ${\mu}{\textrm}{m}$ and 0.5~1 ${\mu}{\textrm}{m}$ in aerodynamic diameter. These results were 2.5~4.7 times higher than anion concentrations collected by Anderson low volume air sampler.

  • PDF