• 제목/요약/키워드: Air Volume Concentration

검색결과 355건 처리시간 0.029초

Air Pollution Protection onboard by Seawater and Electrolyte

  • An Suk-Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.93-101
    • /
    • 2006
  • This research makes a new attempt to apply the activated seawater by electrolysis in the development of two-stage wet scrubber system to control the exhaust gas of large marine diesel engines. First, with using only seawater that is naturally alkaline (pH typically around 8.1). the $SO_2\;and\;SO_3$ are absorbed by relatively high solubility compared to other components of exhaust pollutants, and PM (Particulate Matter) is removed through direct contact with sprayed seawater droplets. Besides, the electrolyzed alkaline seawater by electrolysis, which contains mainly NaOH together with alkali metal ions $(i.e.\;Na^+,\;Mg^{2+},\;Ca^{2+})$, is used as the absorption medium of NOx and $CO_2$. Especially, to increase NOx absorption rate into the alkaline seawater. nitric oxide (NO) is adequately oxidized to nitrogen dioxide $(NO_2)$ in the acidic seawater, which means both volume fractions are adjusted to identical proportion. The results found that the strong acidic seawater was a valid oxidizer from NO to $NO_2$ and the strong alkaline seawater was effective in $CO_2$ absorption In the scrubber test, the SOx reduction of nearly $100\%$ could be achieved and also led to a sufficientPM reduction. Hence, the author believes that applying seawater and its electrolyte would bring the marine air pollution control system to an economical measure. Additionally it is well known that NOx and SOx concentration has a considerable influence on the $N_2O$ emission of green house gas. Although the $N_2O$ concentration exhausted from diesel engines is not as high, the green house gas effect is around 300 times greater than an equivalent volume of $CO_2$. Therefore, we investigated the $N_2O$ removal efficiency with using the electrolyzed seawater too. Finally this research would also plan to treat the effluent by applying electro-dialysis and electro-flotation technique s in the future.

보건용 마스크의 분진포집효율, 흡기저항 및 CO2 농도 (Dust Collection Efficiency, Inhalation Pressure, and CO2 Concentration in Health Masks)

  • 한돈희;김일순
    • 한국환경보건학회지
    • /
    • 제46권1호
    • /
    • pp.78-87
    • /
    • 2020
  • Objectives: To identify the degree of physical burden, a determination was undertaken of dust collection efficiency, inhalation pressure, and CO2 concentration related to health masks certified by the Ministry of Food and Drug Safety (MFDS). Methods: Twenty health masks were purchased on the market. Dust collection efficiency and inhalation pressure were determined in the same manner as in MFDS certification testing, respectively using TSI Model 8130 (TSI, U.S.) and ART Plus (Korea). CO2 concentrations for 20 subjects using a CO2 analyzer (G100, G150, Geotechnical Instrument Ltd., UK) were measured with a similar method as a total inward leakage test. In addition to CO2 levels, dead space volumes in the masks was determined for predicting concentrations of CO2 in inhalation air. Results: Most of the dust collection efficiencies found for the 20 masks were far higher than the standard. Four KF94s met KF99 and four KF80s even met KF94. Most inhalation pressures were also much lower than the standard, with many almost one-half of the standard. The mean and standard deviation of CO2 concentration in the mask were 2.9±0.44%. Considering dead volume, the prediction for CO2 concentration in the inhalation air was 4,395±1,266 ppm. Conclusions: For healthy men and women, the dust collection efficiency and inhalation pressure of health masks were not at a level that would affect their health. Although CO2 levels in the inhalation air were predicted not to affect health, research on the physiological effects of health masks on Koreans is needed for more precise research.

분진 발생 작업장의 분진 발생 실태 및 영향인자에 관한 연구 (Study on the level of dust concentration with affecting factors at a dust emissing workshops)

  • 김희만;김돈균
    • 한국산업보건학회지
    • /
    • 제3권2호
    • /
    • pp.227-239
    • /
    • 1993
  • The author selected 77 dust emissing processes from 71 types of industries which placed in Sasang Industrial Complex in Pusan. The level of total dust was measured as areal concentration and personal exposure concentration by low volume air sampler and personal air sampler, respectively. Collected samples were classified into 5 groups (chemicals and rubber product, metal product, sawmills and wood, foundries and others). Respirable particulate and total dust of areal and personal exposure were analyzed. The results were as follows; 1. All of the respirable dust concentration and total dust of areal and personal concentration were log-normally distributed. 2. Geometric mean of respirable particulate of personal exposure concentration measured $0.55mg/m^3$ in the first group, $0.86mg/m^3$ in the second group, $0.39mg/m^3$ in the third group, $0.81mg/m^3$ in the forth group and $0.52mg/m^3$ in the fifith group. The exceed rates over TLV (thehold limit values) of total dust were 31.3% in the first group, 31.3% in the second group, 70% in the third group, 80% in the forth group and 13.3% in the fifth group. 3. There were singnificant difference between areal and personal exposure concentration and personal exposure concentration was higher than that of area. 4. In the case of high ratio of respirable particulate to total dust, pneumoconiosis incidence was high even though the workshop was opened and emissing dust concentration was low. These findings suggest that it is desirable to measure respirable particulate in environmental assessment of dust emissing workshops.

  • PDF

태백시 소각로 내 NOx 제거를 위한 전산유체역학(CFD) simulation 연구 (Study on Computational Fluid Dynamics(CFD) Simulation for De-NOx in the incinerator at Taebaek city)

  • 김지현;박영구
    • 한국응용과학기술학회지
    • /
    • 제30권2호
    • /
    • pp.320-332
    • /
    • 2013
  • 소각로 내 공기 주입은 연소가스의 체류시간, 미연분 제거 및 출구가스 온도 제어 등의 많은 영향을 끼친다. 이에 따라 2차 연소용 공기량을 변화시켜 충분한 체류시간을 확보하고 $850^{\circ}C$ 이상의 출구가스 온도를 유지하며, 높은 turbulent를 관리함으로써 안정적인 소각로 운영이 되어야만 한다. 본 연구에서는 현재 운영 중인 소각장의 소각로를 설계하고, 평균 일일 소각량을 바탕으로 1차 공기량을 산정한 후 2차 공기량을 변화하여 CFD 프로그램(Fluent)을 통해 이론적인 공기유동을 규명하였다. 또한 산정된 공기량을 바탕으로 실제 운영 중인 소각장에 적용함으로써 최적의 연소조건을 도출하였다. CFD simulation 결과 1.2차 공기비는 75:25가 최적의 결과로 나타났으며, 2차 공기 분사노즐 전 후면 유속 비는 1:3에서 가장 우수한 결과로 나타났다. 또한, 실제 운영 중인 소각로에 적용한 결과 적절한 소각로 출구온도는 질소산화물 제거 효율 및 일산화탄소 발생농도에 영향을 미치는 것으로 나타났다.

서울지역의 시정 장애 요인에 관한 연구 (On the Origin of Visibility Degradation in Seoul)

  • 윤순창;이강웅
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.229-236
    • /
    • 1998
  • Visibility is a good indicator of comprehensive alto quality. The prevailing visibility in Seoul is no better than the past although the average concentration of SO2 and TSP (total suspended particulate) has decreased quite significantly in the past decade, owing to the government efforts to reduce the emission. Then, a question arises why visibility has not been improved. In order to answer this question we have investigated which components of air pollutants are most responsible for the visibility degradation in Seoul. Analysis on the visibility vs the aerosol sixte distribution measured by an optical particle counter shows that the particles of the size interval between 0.5mm and 2.5mm are most responsible for the visibility degradation. Among the criteria air Pollutants, NOB concentration is found to be moot responsible, rather than PM10. ton analysis of the particulate collected by a high volume sampler shows that the nitrate component increases more significantly than other ions when visibility becomes very poor. Therefore, we conclude that the major causes of visibility degradation in Seoul are the increase of NOB, nitrates and the particles of the size range between 0.5mm and 2.5mm.

  • PDF

장대형 터널 내 제트 팬 위치에 따른 환기해석 (Ventilation Analysis according to Jet Fan Location in Long Tunnel)

  • 강신형;변주석;이진호
    • 설비공학논문집
    • /
    • 제19권5호
    • /
    • pp.386-393
    • /
    • 2007
  • This paper studies the ventilation characteristics according to the jet fan location at the long road tunnel using the CFD software 'FLUENT' which is based on the finite volume method. The tunnel model used in the analysis has a length of 1600m, a cross sectional area of $120m^3$, and is composed of 3 lanes and one way. The velocity profile, the distribution of CO concentration and the ventilation flow rate within the tunnel are analyzed, respectively. In the analysis, it is found that the dependence of the ventilation flow rate upon the jet fan location is small, but the CO concentration in the tunnel is at the lowest when the jet fans are installed near the tunnel outlet. An air stream right below the jet fan is almost inactive due to the strong stream injection near the jet fan. Thus, the pollution level below the jet fan must be higher than the other area.

장기간 (1989 ~ 2012) 측정자료를 이용한 용인-수원지역에서의 PM10 및 PM2.5의 오염특성 분석 (질량농도 중심) (PM10 and PM2.5 Characterization based on Mass Concentration Long-term (1989 ~ 2012) Database in Yongin-Suwon Area)

  • 임효지;이태정;김동술
    • 한국대기환경학회지
    • /
    • 제31권3호
    • /
    • pp.209-222
    • /
    • 2015
  • Fine and coarse PM had been collected by LVCI (low volume cascade impactor) and HVAS (high volume air sampler) during January 1989 to April 2012 at Kyung Hee University, Global Campus located on the boarder of Yongin and Suwon. The database of PM mass concentration was constructed and then intensively and extensively investigated to understand monthly, seasonal, and annual patterns of each PM behavior. Especially the study separated all the PM data into the 5 Period Zones, which were classified on the basis of social, political, and environmental issues that might be influencing local ambient air quality during the monitoring period. The overall $PM_{10}$ level had been continuously decreased until 2005 and after then was staggering due to rapidly increasing $PM_{2.5}$ level in $PM_{10}$. The annual average of $PM_{2.5}$ concentration varied from $34.3{\mu}g/m^3$ to $59.0{\mu}g/m^3$, which were much higher than the 2015 ambient air quality standard. The $PM_{2.5}$ level was strongly associated with haze events, while both $PM_{10}$ and $PM_{2.5}$ levels were associated with Yellow storm events. Daily concentrations of $PM_{2.5}$ were ranged $13.1{\sim}212.9{\mu}g/m^3$ in haze days and $33.6{\sim}124.6{\mu}g/m^3$ in Asian dust days. The study also intensively investigated annual and seasonal patterns of $PM_{2.5}/PM_{10}$ ratios.

동축 이중 확산화염의 매연 생성 특성 (Soot Formation in a Double-Concentric Diffusion Flame)

  • 정종수;이교우;고범승;강경태
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1355-1362
    • /
    • 1999
  • An experimental study on a double-concentric diffusion flame(DDF) has been carried on in order to Investigate the characteristics of soot formation compared to a normal coflow diffusion flame(NDF). Laser extinction technique has been used for an ethylene($C_2H_4$) and air flame with various flow rates. Soot formation In the double-concentric diffusion flame was enhanced by the inner inverse diffusion flame due to the increase in flame temperature and also suppressed due to the nitrogen-dilution from the inner air. Soot concentration at the flame axis of DDF was higher than that of the NDF, mainly because of the increase of temperature by inner flame. However, the maximum soot volume fraction of DDF was lower than NDF at the outer side of the flame, mainly due to the effect of nitrogen-dilution from the inner air.

탈기법과 초음파 처리법을 연계한 LPG 지하공동저장소 주변 오염지하수 내 TOC 제거 (The Air-stripping Process Conjugated with the Ultrasonic Treatment to Remove TOC in Groundwater around the LPG Underground Storage Cavern)

  • 한이경;전성천;김단우;전소영;이민희
    • 자원환경지질
    • /
    • 제55권5호
    • /
    • pp.511-519
    • /
    • 2022
  • 본 연구에서는 국내에서 운영 중인 대형 LPG(Liquefied petroleum gas: 액화석유가스) 지하공동저장소 주변 오염지하수 내 TOC(total organic carbon: 전유기탄소)를 효과적으로 제거할 수 있는 탈기법(air-stripping) 기반의 정화공정을 개발하기 위해, 국내 LPG 지하저장소 주변 두 종류의 오염 지하수 시료(초기 TOC 농도는 각각 608 mg/L와 153 mg/L)를 대상으로 TOC 제거 실내 실험을 하였다. 다양한 air-stripping 조건(공기주입량 변화, 온도 변화, 초음파 처리 연계 등)에서 처리수의 TOC 제거효율을 비교함으로써, 최적의 TOC 제거효율을 가지는 air-stripping 기반의 지하수 정화공정을 개발하고자 하였다. Air-stripping의 공기 주입량 변화 실험 결과, 공기주입량이 2 L/min에서 11 L/min로 많아질수록, stripping 시간이 1시간에서 24시간으로 길어질수록, 오염지하수의 TOC 제거율은 증가하였지만, 처리 후 지하수의 TOC 농도는 방류수 수질 기준(100 mg/L 이하)보다 높았다. 정성분석 결과 실험에 사용한 LPG 지하저장소 주변 오염지하수의 TOC 주요 성분은 메탄올과 프로판으로 나타났으며, 메탄올의 경우 물과의 친화성에 의해 air-stripping 효과가 프로판보다 낮아, 장시간의 stripping이 필요한 것으로 판단되었다. 상온(20℃)에서 공기주입량 4 L/min로 24시간 air-stripping 후 오염 지하수의 TOC 제거효율은 59.1%였으나, 온도를 30℃와 40℃로 상승시켰을 때 제거효율은 각각 80.0%와 82.8%로 증가하여, 온도 증가에 따라 TOC 제거효율도 증가하였다. 다만 오염지하수의 온도를 40℃로 유지하여도 24시간 이상 air-stripping을 해야 처리수의 TOC 농도가 방류수 수질 기준을 만족하였다. Air-stripping의 TOC 제거효율을 높이기 위해, 초음파 처리 과정을 병행한 경우, 공기주입량 9 L/min 조건으로 air-stripping을 적용한 결과 5시간 만에 87.8%의 높은 제거효율을 나타내어(처리 후 TOC 농도: 72.4 mg/L) 방류수 수질 기준(100 mg/L)을 만족하였다. 초기 TOC 농도가 낮은 오염지하수의 경우에도 초음파 처리와 air-stripping을 동일한 조건으로 병행한 경우, TOC 제거효율은 89.7%(처리 후 TOC농도: 18.9 mg/L)를 나타내었다. 연구 결과로부터 TOC로 오염된 대형 LPG 지하공동저장소 주변 지하수에 대하여 초음파 처리와 air-stripping을 연계한 정화법을 적용하는 경우, 비교적 짧은 시간(6시간 이하)에 효과적으로 지하수 내 TOC를 제거할 수 있음을 알 수 있었다.

Characteristics of Gas- and Particle-phase Acids and $NH_3$ at Urban and Rural Sites in Korea

  • Ma Chang-Jin;Kim Hui-Kang;Kang Gong-Unn;Tohno Susumu;Kasahara Mikio
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제20권E1호
    • /
    • pp.15-28
    • /
    • 2004
  • To study the characteristics of ammonia and the related compounds, atmospheric aerosols and gases were collected using a triple filter pack sampler, a low volume air sampler, and a three-stage Anderson air sampler in Seoul and Kangwha Island, Korea from Dec. 1996 to Oct. 1997. Ammonia concentrations showed approximately two times higher in summer than in winter at both sites. The highest $HNO_3$ levels were generally observed in summertime at two sampling sites. The average mass concentration of $PM_{2.5}$ in heavily industrialized Seoul was about three times higher than that of Kangwha. In winter, the sum of $NH_4^+$ and its counter ions (such as $Cl^-,\;NO_3^-$, and $SO_4^{2-}$) comprised $30-41\%$ of $PM_{2.5}$ mass concentration at each sampling site. Temperature dependence of particulate nitrate was examined at the urban sampling site. The formation of the nitrate in the fine mode was dependent not only on the amount of precursors but also on the variation of temperature. $(NH_4)_2SO_4$ and $NH_4HSO_4$ coexisted with $NH_4NO_3$ and $NH_4Cl$ at each site. According to the summertime backward trajectory analysis, $NO_3^-$ showed higher level with air parcels transported from northeast Asian continent. On the other hand, the concentration of $SO_4^{2-}$ showed significantly higher level when air masses originated from Pacific Ocean, southern part of Japan, and Korea.