• Title/Summary/Keyword: Air Similarity

Search Result 146, Processing Time 0.022 seconds

A study on Forced Ventilation Rate for Bedroom Indoor Air Quality Improvement (침실 공기질 개선을 위한 강제 환기횟수에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.85-90
    • /
    • 2009
  • The indoor air quality is one of the most important issues of designing ventilation in high rise apartment buildings. This study suggested proper ventilation rate in the apartment bedroom where mechanical ventilation system has installed. Six university students(four male and two female) were participating in the experiment. Experiments were performed in environmental chamber. Experimental conditions were combinations from three ventilation rate 0, 0.4 and 0.7. Measurement items during 8 hours of experimental time were temperature, humidity, carbon dioxide concentrations and questionnaire surveyed aftrer sleeping. The concentration of Carbon Dioxide depending on ventilation rate in the chamber was analyzed for proper ventilation rate. The results of this paper can be summarized as follows. (1) When two persons experiment, 0.7 ventilation rate was in excess of 1000ppm. (2) When one person experiment, 0.7 and 0.4 ventilation rates were satisfied the criteria of IAQ. (3) It compared 0.4 with 0.7 in the ventilation rate, 0.4 ventilation rate could reduced about 80% of the power by fan similarity law.

Cross-sociocultural Comparison of Cognition to Environmental Issues in Countryside with Special Reference to UK and Korea (농촌의 환경문제에 관한 사회 문화적 인식의 비교연구 -한국과 영국을 중심으로-)

  • 이관희
    • Journal of Korean Society of Rural Planning
    • /
    • v.4 no.2
    • /
    • pp.1-7
    • /
    • 1998
  • This research is concerned with a comparative cognition of environmental issues in the countryside between socio-cultural groups. Environmental issues have been con연nod to litter, soil, sewage, wild life, noise, landscape, air, housing development, waste land and pesticides. Socio-cultural groups consisted of urban and countryside people who live in Korea and UK. The method of this study depended upon a standard questionnaire with a semantic scale. The cognition of Korean and British people are significantly different in every respect(p =.0001)except air issues. There is a significant similarity between Korean groups in 10 environmental issues(p > .03). Both Korean groups have generally recognized that their countryside environment has faced serious problems to be solved while British groups have not recognized serious problems in their countryside compared to the Korean groups. To both Korean and British groups the most worrying amongst the 10 environmental issues is the litter problem. In particular, there is a significant difference between British groups in soils(p = .0001), wildlife(p = .0009), air(p = .0001) and waste land(p = .0027). The existing policies (or countryside environment in Korea should be completely reconsidered and in Britain policies towards soils, wild life, air and waste land need to be reviewed. From the results it can be seen that cognition to countryside environment undergoes more cultural influences rather than social ones.

  • PDF

A Study on The Characteristics of the 2-Dimensional Jet (2차원 분류특성에 관한 연구)

  • Kim, Kyung-Hoon;Park, Sang-Kyoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.4
    • /
    • pp.43-51
    • /
    • 1989
  • Free jet was investigated experimentally and numerically in range of Reynolds number from 9900 to 21000. The working fluid was air; the mean velocity components and turbulent quantities were measured by a hot-wire anemometer. In numerical computations, the governing partial differential equations of elliptic type were solved with conventional k- ${\epsilon}$ turbulence model. The measurements show that the jet increased linearly in flow direction, and that similarity for each turbulent quantity such as Reynolds shear stress, or turbulent kinetic energy was revealed in the fully developed region. The computational results show good agreements with experiments.

  • PDF

A computational study on compressible flow of humid air around airfoil (익형 주위의 압축성 습공기 유동에 대한 수치 해석적 연구)

  • ;Zvi Rusak
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.1-7
    • /
    • 2003
  • 습공기에 포함된 수증기가 상(Phase)변화를 일으킬 때 잠열이 발생하고 이 잠열은 익형 주위의 압축성 유동 상태량들을 변화시키므로, 이러한 열 증가가 유동에 끼치는 영향에 대하여 수치해석을 통하여 연구 수행하였다. 수치해석은 Rusak 과 Lee [1]가 최근에 연구 수행한 미교란 방법(small-disturbance approach)에 근거하여 이루어졌다. 고전적 핵 생성 모델과 작은 물방울 성장(droplet growth)모델을 이용한 이 방법에서는 비평형 균질 응축과정에서 일어나는 열 방출을 묘사한다. 응축에 의한 열전달, 압축성 유동의 운동에너지, 그리고 유동의 열적 상태량들 사이에서 일어나는 비선형 상호영향을 조사하고, 또한 주어진 문제를 지배가호 있는 상사 파라미터들을 제시하였다. 계산 결과들은 Euler 방정식을 사용하여 얻은 선행 수치계산들과 비교하여 잘 일치됨을 보였다. 상사법칙은 유동 동역학과 응축 상태량들이 상당히 비슷하게 거동하는 다양한 유동 형태들을 제안한다. 압축성 습공기 유동은 유체기계에 사용되는 익형들의 공력 성능을 증가시키는데 응용될 수 있다.

Study on Low Frequency Characteristics of Rotary Compressor (로터리 압축기 저주파 특성에 관한 연구)

  • Kwon, Byoung-Ha;Park, Sin-Kyu;Hwang, In-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.857-862
    • /
    • 2002
  • Compressor is a major noise source of air-conditioner. Especially, its low frequency band noise below 1000Hz is very important because it will not be attenuated by passing through the cover panel and heat exchanger in air-conditioner. The factors affecting the low frequency band noise are studied by geometric similarity along with several experiments, and the low frequency noise is closely related with the discharge holes of muffler as well as the cavity of lower shell. The low frequency band noise is significantly reduced by proposed designs.

  • PDF

A Study on the Onset of Condensation in a Supersonic Nozzle of Constant Expansion Rate (팽창율이 일정한 초음속 노즐흐름의 응축개시에 관한 연구)

  • 김병지;권순범;이은수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.463-469
    • /
    • 1990
  • A rapid expansion of moist air of condensible gas through a supersonic nozzle gives rise to condensation of nonequilibrium and equilibrium processes. Because most of the effects of condensation on the flow are caused by process of nonequilibrium condensation, it is very important to know the onset. condition of nonequilibrium condensation. In the present study, the relation between the initial relative stagnation humidity and the onset Mach number, for the case of the similarity law suggested by Zierep and Lin. Furthermore, the present theoretical result number is compared with the experimental, numerical and other results.

Study on the Pye(Fei)/Lungs Control Ki(Qi) (폐주기(肺主氣)에 관한 고찰)

  • Song, Ji-Chung;Jung, Hun-Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.4
    • /
    • pp.761-764
    • /
    • 2009
  • The Pye is one of the organs in oriental medicine, which has functions of controlling Ki. The Lungs is also a organ that has a function of respiration, in western medicne. Ki means the air in the first notion. Therefore, the functions of the Lungs and Pye are no differences. However, Ki doesn't mean the air only. Respiration in western medicne has two meanings. One of them is a external respiration, ang the other is a cellular respiration. In that process, the Lungs supervise oxygen and oxidation of protein, carbohydrate and fat and prduce ATP as energy. Two of Functions in Ki are Choodong(推動;Tuidong) and Onhoo(溫煦;Wenxu). Choodong means making energy ang Onhoo means making heat, that indicate a similarity functions of Pye and Lungs from the view of making energy.

Hydrographic Model Test on Prevention against Vortex Occurrence for Vertical Bulb Turbine

  • Yamato, Shoichi;Nakamura, Shogo;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.418-425
    • /
    • 2009
  • A vertical bulb turbine unit with elbow type draft tube has been developed due to avoidance of complicated assembling and long standstill period at overhaul in comparison with conventional horizontal bulb turbine unit. Before designing the prototype vertical bulb unit, a hydrographic model test was carried out to establish the ideal design concept for this innovative generating unit. Froude similarity is not available for vortex occurrence. Consequently, an intake structure without air entraining vortices under all the flow conditions is developed, and it is confirmed that the surge wave at load rejection is not affected harmful influence for other constructions.

The Hydrodynamic Stability of Natural Convection Flows Adjacent to an Inclined Isothermal Surface Submerged in Cold, Pure Water (순수한 찬물속에 잠겨있는 경사진 등온벽면 부근의 자연대류에 관한 수동력학적 안정성)

  • Hwang, Y.K.;Jang, M.R.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.4
    • /
    • pp.268-278
    • /
    • 1990
  • Hydrodynamic stability equations are formulated for natural convection flows adjacent to a heated or cooled, inclined, isothermal surface in pure water at $4^{\circ}C$, where the density variation with temperature becomes nonlinear. The resulting stability equations, when reduced to ordinary differential equations by a similarity transformation, constitute a two-point boundary-value problem, which was solved numerically. It is found from the obtained stability results that the neutral stability curves are systematically shifted to have lower critical Grashof numbers, as the inclination angle of upward-facing plate increases. Also, the nose of the neutral stability curve becomes blunter as the angle increases. It implies that the greater the inclination of the upward-facing plate, the more susceptible of the flow to instability for the wide range of disturbance wave number and frequency.

  • PDF

An Experimental Study on the Flow Characteristics of a Swirl-Jet Diffuser (공장환기용 선회 제트 디퓨저의 유동 특성에 관한 실험 연구)

  • Lee, C.S.;Jurng, J.;Jeong, S.Y.;Hong, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.103-109
    • /
    • 1994
  • An experimental study is performed on the flow characteristics of a swirl-jet diffuser for factory ventilation. Swirl number ranges from 0(nonswirl jet) to 0.6 when the angle of swirl vane is 60 degree. As swirl becomes strong, the maximum velocity in the plane perpendicular to jet axis decreases fast and the uniformity of velocity becomes good, particularly in the ventilated area. The similarity in velocity profiles has been found for axial velocity from even when swirl number equals 0.6. The flow characteristics of the swirl-jet which has the swirl number of 0.6 is thought to be the best among these three swirl numbers for factory ventilation. However, the pressure drop in the diffuser increases as the swirl becomes strong. This should be considered in the design of the total ventilation system including a duct system.

  • PDF