• Title/Summary/Keyword: Air Quantity

Search Result 509, Processing Time 0.028 seconds

Growth and Bulb Characteristics of Extremely Early-Maturing Onion by Air Temperature Variation at Different Altitudes (해발고도별 기온변화에 따른 극조생 양파의 생육 및 구특성)

  • Song, Eun Young;Moon, Kyung Hwan;Wi, Seung Hwan;Oh, Soonja
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.4
    • /
    • pp.321-329
    • /
    • 2018
  • A study was carried out to determine the influence of climatic environments on the growth characteristics and bulb quality of extremely early-maturing type onion grown at different altitudes, such as 60m, 200m, 350m and 700m above sea level (ASL). The mean air temperature during the growing season of extremely early-maturing type onion (October 18 to April 27) was $10.8^{\circ}C$, $9.6^{\circ}C$, $8.1^{\circ}C$ and $6.1^{\circ}C$ at 60m, 200m, 350m and 700m ASL. The mean air temperature during the bulb growth period (March 16 to April 14) was recorded $10.5^{\circ}C$, $9.4^{\circ}C$, $7.9^{\circ}C$ and $6.0^{\circ}C$ at 60m, 200m, 350m and 700 m ASL. Plant height, neck diameter, leaf number, leaf area, top fresh weight and top dry weight were significantly increased in growing of extremely early-maturing type onion at 60m ASL. Bulb/neck diameter ratio increased rapidly under the same temperature regime. The diameter and weight of the bulb were also the largest at 60m ASL during the bulb growth period (daily mean temperature of $12.5^{\circ}C$). At 60m ASL, there was the highest bulb size like a height, diameter and weight of bulb related directly on onion yield in the bulb growth period from March 16 to April 14. In contrast, yield and bulb quality were considerably decreased at 700m ASL during the bulb growth stage (daily mean temperature of $8.4^{\circ}C$). The quantity of extremely early-maturing type onion has gradually decreased as the daily average temperature drops below $12.5^{\circ}C$ during the bulb growth stage (March 16 to April 14). As a result, the lower temperature (daily mean temperature below $12.5^{\circ}C$) during the bulb growth stage significantly decreased the size and quantity of bulb in direction proportion.

Analysis of Environment Factors in Pleurotus eryngii Cultivation House (새송이버섯 재배사의 환경요인 분석)

  • Yoon, Yong-Cheol;Suh, Won-Myung;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.12 no.4
    • /
    • pp.200-206
    • /
    • 2003
  • Pleurotus eryngii(King oyster) is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality Eryngii all the year round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. At the commercial mushroom cultivation house(A,B), this study was carried out to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. this experiment was conducted for about two-month from Nov. 11, 2002 to Dec. 30, 2002 in Eryngii. cultivation house-A, B. Ambient temperature during the experiment period was not predominantly different from that of a normal year. The capacity of the hot water boiler and the piping systems were not enough. Maximum air temperature difference between the upper and lower growth stage during a heating time zone was about 2~3$^{\circ}C$. The max. and min. relative humidity were ranged approximately 60~100%, and average relative humidity was ranged approximately 80~100%. And $CO_2$concentration increased until maximum 1,600~1,800 ppm with the passing growing period. The illuminance in cultivation house was widely distributed from 20lx to 160 lx in accordance with position, and it was maintained lower than the recommended illuminance range 100~200 lx. The average yield per bottle was about 67~85g. But the optimal productivity will be evaluated by considering the quality and quantity of mushroom production, energy requirements, facility construction and management cost, etc.

Energy Expenditure in Crossbred Cattle Fed Paddy Straw of Different Form

  • Bhatta, Raghavendra;Kumar, Vijay;Sridhar, Manpal;Singh, Khub
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.12
    • /
    • pp.1755-1760
    • /
    • 2006
  • Studies were carried out at the National Institute of Animal Nutrition and Physiology, India to determine the effect of feeding chopped paddy straw (Oryza sativa) on the energy expenditure in crossbred cattle. Four crossbred cattle male, aged 5-6 years and weighing about 450 kg were used for this study. Three experimental trials, one each for the feeding of un-chopped paddy straw offered ad libitum (UCA), chopped paddy straw fed at restricted level (CR) and chopped paddy straw offered ad libitum (CA) were conducted. The quantity of un-chopped paddy straw consumed during UCA was assumed as the voluntary intake by the cattle and the same quantity was offered after chopping during CR. Each trial comprised of 21 d preliminary feeding period and 5 d of observation recording period. Expired gas was collected in Douglas bags using a face-mask and three-way valve at 6 hourly intervals i.e., at 09.30, 15.30, 21.30, and 03.30 h throughout the observation period. Expired gas and ambient air inspired by the animals were analyzed for the oxygen content through paramagnetic oxygen analyzer. Energy expenditure (EE) by the animals was calculated by determining the volume of oxygen consumed per minute (STP) and multiplying by 4.825. Paddy straw used in all the three trials contained (g/kg DM) 90.0 CP, 786 OM, 700 NDF, 489 ADF, 357 Cellulose and 60.0 ADL. Metabolizable energy (ME) was 6.9 MJ/kg DM. Dry matter intake (DMI) both in UCA and CR was about 6.8 kg, except that it was chopped in CR. Chopping has resulted in 32% improvement (9 kg) in DMI of CA as compared to that of UCA. Although ME intake was similar in UCA and CR (47.2 MJ/day), energy expenditure (EE) was higher in UCA (23.3 MJ) when compared to that of CR (19.5 MJ). The ME intake (63.3 MJ) as well as EE (27.1 MJ) was highest in CA. Energy expenditure when expressed as MJ/kg DMI was 3.48, 2.90 and 3.12; whereas as per cent of ME intake it was 50, 41 and 44 in UCA, CR and CA respectively. Our study has unequivocally confirmed that chopping of poor quality roughages like paddy straw has definite advantages not only in terms of improving the intake by decreasing the time taken for ingestion but also in reducing the energy cost of eating.

Comparison of TVOCs emission characterization of paint and putty according to the amendment of test specimen preparation method (시험편 제작방법 변경에 따른 페인트, 퍼티의 TVOCs의 방출 특성 비교)

  • Park, Joon-Man;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.109-118
    • /
    • 2010
  • Amended at the Law of indoor air quality management open a court according to the test method and excess standard of the fluid building material were changed. It used the paint and the putty in the fluid building material from this research and comparison of amended and original method it led and in about change direction of amended standard with change of the emission rate who is caused by in the amended test method and excess standard it examined. The reduction emission rate about 45% decreases in the change of test period of the paint, there was not an effect of the emission rate whom it follows in change of dry time. Also change of the emission rate whom it follows in change of application quantity the product which above $5\;mg/m^2h$ has the high emission rate the change of the emission rate is big but there was not change of the emission rate from the products of that others. The putty the emission rate about 61% decreases in case in the change of test period, there was not an effect of the emission rate whom it follows at dry time. The emission rate about 164% increased with increase of application quantity. It tried to compare two test methods, it compared in the paint and putty all current test method it was relaxed the possibility of knowing the thing there was a standard.

The Study of Reuse, Putting the Bulking Agent into Food Waste and Livestock Feces (음식물쓰레기와 축산폐기물에서 Bulking agent의 재이용에 관한 연구)

  • Kim, S.B;Choi, H.G;O, G.J;Yang, C.O;Lee, S.G
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.3
    • /
    • pp.127-135
    • /
    • 2001
  • Achieved to grasp possibility to use compost that make food waste and sawdust (bulking agent) by raw material in this research droopingly to bulking agent calamity. To be kept by aerobic experiment method to 4 composting device that air is supplied Food Waste + Sawdust, Livestock Feces + Sawdust, Food Waste + Compost, Livestock Feces + Compost free medical care and investigated composting sledding and temperature, pH, the moisture rate, heavy metals item etc. Judged that food waste of the moisture rate mix experiment result food waste input (food waste and sawdust composting done material mean) compost happened after resources anger as bulking agent food waste and Livestock Feces quantity is 72~77%, because axis dries to promote optimum composting progress appearing by 64~65%, thing which use need and was difficult to set salt 1% that is by-product compost standard when use compost as bulking agent of food waste but by dilution effect of Livestock Feces quantity using compost being expose that preservation is available by standard low because salt content density of done compost becomes found possibility that can solve salt content problem.

  • PDF

Analysis of Environment Factors in Pleurotus eryngii Cultivation House of Permanent Frame Type Structure (영구형 큰느타리버섯 재배사의 환경요인 분석)

  • Yoon Yong-Cheol;Suh Won-Myung;Lee In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.125-137
    • /
    • 2006
  • Pleurotus eryngii is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality Eryngii all the yew round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. At the commercial mushroom cultivation houses of permanent frame type (A, B), this study was carried out to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. This experiment was conducted for about two-year ken Nov. 2003 to Dec. 2005 in cultivation house. Ambient temperature during the experiment period was not predominantly different from that of a normal year. The capacity of the hot water boiler and the piping systems were not enough. Because the capacity of electric heater and air circulation were not enough, air temperatures in cultivation house before improvement of system were maintained somewhat lower than setting temperature, and maximum air temperature difference between the upper and lower growth stage during a heating time period was about 5.1. But the air temperatures after system improvement were maintained within the limits range of setting temperature without happening stagnant of air. Air temperature distribution was generally distributed uniform. Relative humidity in cultivation house before , improvement was widely ranged about $44{\sim}100%$. But as the relative humidity after improvement was ranged approximately $80{\sim}100%$, it was maintained within the range of relative humidity recommended. And $CO_2$ concentration was maintained about $400{\sim}3,300mg{\cdot}L^{-1}$ range. The illuminance in cultivation house was widely distributed in accordance with position, and it was maintained lower than the recommended illuminance range $100{\sim}200lx$. The acidity of midium was some lower range than the recommend acidity range of pH $5.5{\sim}6.5$. The yield was relatively ununiform. In case of bottle capacity of 1,300cc, the mushroom of the lowest grade was less than 3%. The consumption electric energy was quite different according to the cultivation season. The electric energy consumed during heating season was much more than that of cooling season.

Effects of the Odor Abatement System in a Naturally Ventilated Growing Finishing Pig House (자연환기식 육성.비육돈사의 악취탈취장치 적용효과)

  • Lee, S.H.;Yun, N.K.;Kim, K.W.;Yum, S.H.;Cho, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • Ammonia gas is one of the malodorous gases from swine production facilities, such as manure storage tank, manure fermentation facilities, and livestock houses, etc. Ammonia gas from swine house is being emitted at relatively low concentrations throughout the year. Therefore, livestock facilities were continuously ventilated to supply fresh air for respiration of the animals internal the livestock facilities. The swine facilities need very high ventilation rate to control the inside environmental conditions. The deodorization system of the livestock facilities must be developed considering the ventilation rates. The odor abatement system was installed in order to improve the internal environment of the naturally ventilated growing-finishing pig house. The system which distributes the deodorized air into inner space of the swine house by using plastic duct was installed. Since the internal environment, effected by the operation of the odor abatement system, is monitored by closing the winch curtain installed on the side wall of the pig house, the experiment was practiced at the season when the internal environment becomes aggravated, winter. The effects on the improvement in the internal environment of swine house by operating the odor abatement system are as follows ; 1. By re-distributing the air which was deodorized by the odor abatement system installed in the pig house, the result showed that the concentration of ammonia gas is decreased approximately 33.3% compared with that before operating odor abatement system. 2. The effect on the pig house's ammonia gas reduction was found that the ventilation rate was less than $0.5m^3$/min head. The effect of the operation of the odor abatement system showed to be scarce when the ventilation rate increases because of the influx of external fresh air makes the quantity of diluted air more than those of the odor abatement system. 3. The perishment rate of the pigs which were brooded until slaughtering decreased about 3.8% by operating the odor abatement system in the growing-finishing pig house. Also, after operating the odor abatement system, the stinging of the eyes, suspension dust, etc were decreased when going into swine house for management.

  • PDF

An Experimental Study on the Two Stage-Ignition of Cool Flame and Hot Flame in HCCI Engine According to Fuel Composition (연료조성에 따른 HCCI 엔진의 냉염 및 열염의 2단연소 특성에 관한 실험적 연구)

  • Kim, Hyung-Min;Ryu, Jea-Duk;Lee, Ki-Hyung;Lee, Chang-Sik
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.13-19
    • /
    • 2003
  • As the environmental pollution becomes serious global problem, the regulation of emission exhausted from automobiles is strengthen. Therefore, it is very important to know how to reduce the NOx and PM simultaneously in diesel engines, which has lot of merits such as high thermal efficiency, low fuel consumption and durability. By this reason, the new concept called as Homogeneous Charge Compression Ignition(HCCI) engines are spotlighted because this concept reduced NOx and P.M. simultaneously. However, it is well known that HCCI engines increased HC and CO. Thus, the investigation of combustion characteristics which consists cool and hot flames for HCCI engines were needed to obtain the optimal combustion condition. In this study, combustion characteristics for direct inject type HCCI engine such as quantity of cool flame and hot flame, ignition timing and ignition delay were investigated to clarify the effects of these parameters on performance. The results revealed that diesel combustion showed the two-stage ignition of cool flame and hot flame, the rate of cool flame increase and hot flame decrease with increasing intake air temperature. On the other hand, the gasoline combustion is the single-stage ignition and ignition timing is near the TDC. In addition mixed fuel combustion showed different phenomenon, which depends on the ratio of gasoline component. Ignition timing of mixed fuel is retarded near the TDC and the ignition delay is increased according to ratio of gasoline.

  • PDF

A Study on $CO_2$ Emission Estimation linked Port Action (항만 연계활동에 기초한 이산화탄소 배출량 추정)

  • Kim, Hwan-Seong;Jo, Min-Ji
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.173-174
    • /
    • 2010
  • As the quantity of goods transported, port industry and inland transport industry have developing to transport 630million ton goods annually. And the inland transport industry consists of ground transport for almost 80% of total transported goods. But, ground transport causes some serious problems especially the emission of greenhouse gases from trucks. According to issue "global warming", many regulations and agreements with countries in the world are becoming necessary and it is being fulfilled now. It is sure that Korea will have duty to reduce CO2 emission from 2013. Thus inland transport must cut off CO2 emission level. Therefore this paper will address that the calculation of CO2 emission under route of transportation container from six major container ports in Korea. And then, it will predict CO2 emission of inland transport industry according to increasing container traffic rate at ports.

  • PDF

Fugitive Emission Characteristics of HFC-134a from Waste Kimchi Refrigerator (폐김치냉장고에서의 HFC-134a 탈루배출 특성에 대한 연구)

  • Kim, Eui-Kun;Kim, Seungdo;Lee, Young Phyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • In 1995 Kimchi refrigerator was developed at first, and has used HFC-134a as refrigerant. Kimchi refrigerator has been made 1,044,694 on the basis of 2010, disposed about 160,000 per year. Although mobile air conditioning, commercial refrigerator, general refrigerator is regarded as a major source of HFC-134a, little information is available for its emission characteristics of HFC-134a. This paper addresses the fugitive emission factors of Kimchi refrigerator at use-phase and disposal-phase. The residual quantities of Korean-made fifty three waste Kimchi refrigerators were weighed using a commercial recover of refrigerants to determine the emission factors at the disposal-phase. On the other hand, the emission factors at use-phase were estimated from the residual quantities and operating times. The average residual rate of forty three scarp Kimchi refrigerators is determined to be $74.6{\pm}5.2%$. The emission factor at the use-phase is estimated to be $3.5{\pm}0.8%/yr$ as a result of using average age of 11.7 years and the average residual rate determined here. The emission factor at the disposal-phase is determined to be 31.3% after adopting 58% of the recycling rate of refrigerant reported by Recycling Center. We estimate 3.1 g/yr for the average emission quantity of HFC-134a per operating refrigerator, while 22.5 g for that per waste Kimchi refrigerator. Since the chemical compositions of refrigerant of waste Kimchi refrigerator were the same as those of new refrigerant, it is expected that the HFC-134a recovered from waste Kimchi refrigerator can be reused for refrigerant.