• 제목/요약/키워드: Air Pollution Monitoring Network

검색결과 50건 처리시간 0.028초

대기오염도 실측에 의한 대기오염 자동측정망의 대표성 평가 (Evaluation of the Representativeness of Air Quality Monitoring Network in Seoul through Actual Measurement)

  • 전의찬
    • 환경영향평가
    • /
    • 제5권1호
    • /
    • pp.79-85
    • /
    • 1996
  • Simultaneous monitoring in many locations is necessary to evaluate the air quality and analyze future trend of a city, For this purpose, it is essential to install air pollution monitoring network. The first automatic air pollution monitoring network was introduced Seoul in 1973. As of 1995, 20 monitoring stations are now in operation. Concerning the management of the air pollution monitoring network, there was some argument among the relavant scholars, non-governmental organization(NGO) and the government organization. So far, there was no extensive evaluation and analysis about the network. The purpose of this study was to evaluate the representativeness of air quality monitoring network through actual measurement of the concentration of the air pollutant. The concentration of NOx was extensively measured widely in Seoul area three times using the TEA simple measuring technique. Even the judgement level for the area representativeness was lowered to 80%, Ssangmun-dong monitoring station tend to overestimate the pollutant concentration of the covered area. While, Sinlimdong monitoring station tend to underestimate the pollutant concentration of the covered area.

  • PDF

부산지역 오존 및 이산화질소 농도의 공간분포해석에 따른 대기오염측정망 배치연구 (A Study on Allocation of Air Pollution Monitoring Network by Spatial Distribution Analysis of Ozone and Nitrogen Dioxide Concentrations in Busan)

  • 유은철;박옥현
    • 한국대기환경학회지
    • /
    • 제20권5호
    • /
    • pp.583-591
    • /
    • 2004
  • In this study, methodologies for the rational organization of air pollution monitoring network were examined by understanding the characteristics of temporal and spatial distribution of secondary air pollution, whose significance would increase hereafter. The data on $O_3$ and $NO_2$ concentrations during high ozone period in 1998~1999 recorded at the nine air pollution monitoring station in Busan were analysed using principal component analysis (PCA) and cumulative semivariogram. It was found that the ozone concentration was deeply associated with the daily emission characteristics or the $O_3$ precusors, and nitrogen dioxide concentration largely depends on the emission strength of regional sources. According to the spatial distribution analysis of ozone and nitrogen dioxide in Busan using cumulative semivariograms, the number of monitoring stations for the secondary air pollution can be reduced in east-west direction, but reinforced in north-south direction to explain the spacial variability. More scientific and rational relocation of air pollution monitoring network in Busan would be needed to investigate pollution status accurately and to plan and implement the pollution reduction policies effectively.

GIS를 이용한 도심지 대기오염 측정망 최적위치 선정에 대한 연구 : 서울특별시를 대상으로 (Study on Optimal Location of Air Pollution Monitoring Networks in Urban Area Using GIS : Focused on the case of Seoul City)

  • Kim, Ayoung;Kwon, Changhee
    • 한국재난정보학회 논문집
    • /
    • 제12권4호
    • /
    • pp.358-365
    • /
    • 2016
  • 미세먼지는 실생활과 밀접한 관련이 있으며 특히, 2014년 2월부터 대국민 환경서비스 제공의 일환으로 미세먼지 예보제를 시행중에 있어, 대기오염 측정망을 통한 미세먼지 측정자료의 신뢰성을 확보할 필요성이 대두되었다. 환경부에서는 국가 대기질 파악 및 대기정책수립을 위해 대기오염측정망(11종 506개소)을 운영 중이다. 그러나 현재 측정소 입지 선정 과정과 적합성을 확인 및 점검하는 체계가 미흡하다. 따라서 본 연구에서는 GIS를 활용한 도시 공간분석을 통해 대기오염 측정시설의 적절성 및 입지 형평성 등을 평가하고자 한다. 분석 결과를 통해 향후 서울시 대기오염 측정망 설치 계획에 반영 될 수 있도록 측정망의 최적입지를 도출함을 최종 목적으로 한다.

지하철 역내 가스 검출 원격 모니터링 시스템 구현 (Development of a remote monitoring system for gas detection at the subway station)

  • 박용만;김희식;김규식;이문규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

Applications of Drones for Environmental Monitoring of Pollutant-Emitting Facilities

  • Son, Seung Woo;Yu, Jae Jin;Kim, Dong Woo;Park, Hyun Su;Yoon, Jeong Ho
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • 제2권4호
    • /
    • pp.298-304
    • /
    • 2021
  • This study aimed to determine the applicability of drones and air quality sensors in environmental monitoring of air pollutant emissions by developing and testing two new methods. The first method used orthoimagery for precise monitoring of pollutant-emitting facilities. The second method used atmospheric sensors for monitoring air pollutants in emissions. Results showed that ground sample distance could be established within 5 cm during the creation of orthoimagery for monitoring emissions, which allowed for detailed examination of facilities with naked eyes. For air quality monitoring, drones were flown on a fixed course and measured the air quality in point units, thus enabling mapping of air quality through spatial analysis. Sensors that could measure various substances were used during this process. Data on particulate matter were compared with data from the National Air Pollution Measurement Network to determine its future potential to leverage. However, technical development and applications for environmental monitoring of pollution-emitting facilities are still in their early stages. They could be limited by meteorological conditions and sensitivity of the sensor technology. This research is expected to provide guidelines for environmental monitoring of pollutant-emitting facilities using drones.

대구지역 대기오염자동측정망 위치의 타당성 분석 (Feasibility Study for the Location of Air Quality Monitoring Network in Daegu Area)

  • 최성우;이중범
    • 한국환경과학회지
    • /
    • 제20권1호
    • /
    • pp.81-91
    • /
    • 2011
  • Air quality monitoring networks are very important facilities to manage urban air pollution control and to set up an environmental policy. Since air quality monitoring network of Daegu was allocated from 1980s to mid-90s, there is need to reevaluate it and relocated its site. This study was evaluated the position of Daegu air quality monitoring station by unit environmental sensitivity index, grid emission rate, CAI (Comprehensive Air-quality Index) point. The investigation domain covered an area of 16 $\times$ 24 km centered at the metropolitan area of Daegu with grid spacing of 2 km. The location of alternative air quality monitoring networks was selected through optimization and quintiles analysis of total score. The result showed that all things considered, new air quality monitoring network need to install grid numbers 10, 28, 36, 37, 46. We also recommand three scenarios of alternative air quality monitoring network when considering unit environmental sensitivity index, emission rate and CAI point.

무선네트워크기반 공기질 실시간 모니터링 시스템 (Real-time Air Quality Monitoring System Based on Wireless Network)

  • 백승현;이준영;정상우;박홍배
    • 대한임베디드공학회논문지
    • /
    • 제11권3호
    • /
    • pp.143-151
    • /
    • 2016
  • In this paper, a real-time air quality monitoring system based on wireless network is designed and implemented for industrial park or multiuse facilities. The existing gas detector is high price and hard to apply the remote monitoring system. On the other hand, demand for air quality monitoring is increasing because of industrial gas accident, air pollution, and so on. In Korea, indoor air regulation was established by law. According to indoor air regulation, CO2, CO, and NO2 are important gases as the air quality standard. So we study the gas detector for indoor air quality and the wireless network system. The wireless network consist of sensor network and WCDMA to apply various place. To verify the performance of the implemented gas detector, the gas measurement experiment is performed in laboratory environment by using the realized gas detecting wireless sensor node. And we evaluate the experiment results.

A Commentary on Air Pollution Monitoring Programs in Korea

  • Ghim, Young-Sung;Kim, Jin-Young;Shim, Shang-Gyoo;Moon, Kill-Choo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E1호
    • /
    • pp.21-28
    • /
    • 2002
  • Air quality issues in Korea rapidly changed at the beginning of the 1990s from primary to secondary pollutants starting in Seoul, the capital of Korea. The present frame of national air pollution monitoring networks was established between the end of the 1980s and the beginning of the 1990s. Background monitoring was initiated in the middle of the 1990s in response to increasing public concern about the long-range transport of air pollutants. Apart from the national monitoring, both routine and intensive measurements of fine particles have been made for research purposes since the middle of the 1990s at several background sites. However, air pollution monitoring in urban areas for other purposes was relatively scarce as national monitoring has been concentrated in these areas. Although ozone pollution has become a significant issue in major metropolitan areas every summer, only a little information on ozone precursors is available. During the past few years, the number of national monitoring stations has greatly increased. The government has a plan to gradually expand monitoring items as well as stations. It is anticipated that highly detailed information on both photochemical reactants and products will be available within the next several years. More emphasis will be placed on toxic substances based on risk assessment in monitoring for both research and policy making.

지역 대기질 측정망에 나타난 국내 대기오염도의 최근 동향 -2002년 고농도 사례 및 그 기상 특징 (On the Recent Air Pollution Levels Observed in the Regional Air Monitoring Network -High Air Pollution Concentration Episodes and Their Meteorological Characteristics in 2002)

  • 김철희;박일수;이석조;김정수;진형아;성한규
    • 한국대기환경학회지
    • /
    • 제20권2호
    • /
    • pp.215-224
    • /
    • 2004
  • We report the high concentration episodes for PM$_{10}$, SO$_2$, NO$_2$, and $O_3$ in many urban areas Korea during 2002. The high concentration episodes are identified based on the National Ambient Air Quality Standards and the observations obtained from the Regional Air Monitoring Network composed of approximately 160 air pollution monitoring stations located in a number of major or big cities in South Korea including Seoul, Pusan, Daegu, and Incheon cities. The results show that the twenty cases of high concentration episodes in 2002 consists of both ozone warning episodes (6 cases) and high PM$_{10}$ concentration cases (14 cases), and one half of the latter are found to occur in association with the Yellow Sand (Asian Dust) phenomena. The most outstanding characteristics of the reported episodes are the excessively high levels of maximum PM$_{10}$ concentrations during the Yellow Sand period (i.e., exceeding 3,000$\mu\textrm{g}$/㎥ in April, 2002) and their variable occurrence frequencies across seasons. The high ozone concentration episode days are mainly resulting from both the high photochemical reactions and poor ventilations. The high PM$_{10}$ concentration days during non Yellow Sand periods, however, mostly occurred under the influence of synoptic meteorological conditions such as stagnant or slowly passing high pressure centers, and consequently prevailing weak wind speeds over the Korean peninsula. The overall results of our study thus suggest the importance of both synoptic and local meteorological factors for high concentration levels in the major and/or big cities in Korea.n Korea.

地域代表性과 汚染被害를 考慮한 大氣汚染 測定網 配置技法의 開發에 關한 硏究 (Development of an Air Pollution Monitoring Network Design Method Based on Regional Representativeness and Pollution Damage Impact)

  • 김태형;김정욱
    • 한국대기환경학회지
    • /
    • 제3권1호
    • /
    • pp.47-54
    • /
    • 1987
  • A new method for designing air pollution monitoring newtork is presented in this study. In this method, the magnitudes and the correlation coefficients of predicted concentrations in each grid points are examined and the monitoring stations are assigned to those stations which cover the damage cost the most. This method was applied to the Ulsan-Onsan Industrial Complex. This method turned out to be much more efficient than the method of TM coordinates and the method of concentric circles prescribed in the Standard Methods for Pollution Measurement as well as the existing monitoring system established in the area. The 21 stations selected by the method of TM coordinates could cover only 64.4% of the damage cost in the area, the 16 stations by the method of concentric circles 72.1%, and the existing 21 stations 67.8%, while 11 stations were enough to cover 90% of the damage cost in the area with this method. It also was found that this method required only 24 stations to cover the entire area.

  • PDF