• Title/Summary/Keyword: Air Particles

Search Result 1,523, Processing Time 0.029 seconds

A study on Removal Method of Humidifier Particles Using Electrostatic Precipitation Technology

  • Inpyo Cha;Taekeon Jung;Hyunjun Yun;Chuljun Choi
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.239-245
    • /
    • 2023
  • In this research, our objective was to investigate the efficacy of electrostatic precipitation in capturing mist particles. We assumed that it could be helpful in multi-functional facilities and similar environments where both humidification and dehumidification are required. We derived the air density of the humidified air based on its properties using Dalton's law. The analysis was performed to evaluate the collection efficiency of capturing mist aerosols of various sizes. As a result, we revealed that under the conditions of a dry-bulb temperature of 26.0℃ and relative humidity of 8%, the system achieved a collection efficiency of 99.999% or more for aerosols larger than 2.5㎛. These results indicate that electrostatic precipitation technology shows great promise as an effective method for capturing mist particles.

Collection Performance of an Electret Cabin Air Filter for Fine Particles (승용차용 정전 필터의 미세 입자 포집 특성)

  • Ji, Jun-Ho;Gang, Seok-Hun;Kim, Dong-Cheol;Hwang, Jeong-Ho;Yun, Ung-Seop;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1650-1658
    • /
    • 2001
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the fractional collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using highly monodisperse particles ranging from 0.02 to 0.6 $\mu\textrm{m}$ in diameter at three different charging states: singly charged, uncharged, and equilibrium charged. The face velocity was varied from 2.4 to 20.4 crus. It was fecund that the fractional efficiency curve fur singly charged particles shows a typical trend that the collection efficiency is minimum at about 0.3 $\mu\textrm{m}$ in diameter. The fractional efficiency of equilibrium charged particles were not severely varied with the particle diameter. The collection efficiency curve fur uncharged particles has a minimum near 0.1 $\mu\textrm{m}$ in diameter. Another experiment was conducted for a cartridge filter to examine the effect of charge depletion on the collection efficiency in a cabin air filter. The result shows that the charge depletion of the cartridge filter can significantly lower the collection efficiency.

Fluid dynamical characteristics of microencapsulated phase change material slurries (미립잠열슬러리의 유체역학적 특성연구)

  • 이효진;이승우;이재구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.549-559
    • /
    • 1999
  • An experimental study was peformed to measure the viscosity of microencapsulated PCM slurries as the functions of its concentration and temperature, and also influence to its fluid dynamics. For the viscosity measurement, a rotary type viscometer, which was equipped with temperature control system, was adopted. The slurry was mixed with water and Sodium Lauryl Sulphate as a surfactant by which its suspended particles were dispersed well without the segregation of particles during the experiment. The viscosity was increased as the concentration of MicroPCM particle added. The surfactant increased 5% of the viscosity over the working fluid without particles. Experiments were proceeded by changing parameters such as PCM particles'concentration as well as the temperature of working fluid. As a result, a model to the functions of temperature for the working fluid and its particle concentration is proposed. The proposed model, for which its standard deviation shows 0.8068, is agreed well with the reference's data. The pressure drop was measured by U-tube manometer, and then the friction factor was obtained. It was noted that the pressure drop was not influenced by the state of PCM phase, that is solid or liquid in its core materials at their same concentration. On the other hand, it was described that the pressure drop of the slurry was much increased over the working fluid without particles. A friction factor was placed on a straight line in all working fluids of the laminar flow regardless of existing particles as we expected.

  • PDF

Simultaneous Measurement of Fluid Velocity and Particle Velocity in a Particle-Containing Fluid Flow (입자가 포함된 유동장에서 유체속도와 입자속도의 동시 측정기법)

  • Jin Dong-Xu;Lee Dae-Young;Lee Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.355-363
    • /
    • 2005
  • A novel method for simultaneously measuring the fluid velocity and the large particle velocity in a particle-containing fluid flow is developed in this study. In this method, the fluid velocity and the large particle velocity are measured by PIV and PTV, respectively. The PIV and PTV images are obtained from the same flow images. Since a PIV result represents the average displacement of all particles in an interrogation area, it will include an error caused by the relative displacement between the large particles and the fluid. In order to reduce the false influence of large particles on the PIV calculation, the mean brightness of small PIV particle images is substituted to the locations of large particles in the PIV images. The simulation results showed that the new method significantly reduces the PIV error caused by the large particles even at the case where the large particles occupy area fraction as large as $20\%$ of the full image.

Performance Determination of Novel Design Eddy Current Separator for Recycling of Non-Ferrous Metal Particles

  • Fenercioglu, Ahmet;Barutcu, Hamit
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.635-643
    • /
    • 2016
  • Improvements were made in the study for the design of the conventional Eddy Current Separator (ECS) used for separating small sized non-ferrous particles in the waste. These improvements include decreasing the air gap between the material and magnetic drum, making the drum position adjustable and placing the splitter closer to the drum. Thus, small particles were separated with high efficiency. The magnetic drum was removed from inside the ECS conveyor belt system as design change and was placed as a separate unit. Hence, the force generated on the test material increased by about 5.5 times while the air gap between the non-ferrous materials and drum decreased from 3 mm to 1 mm. The non-metal material in the waste is separated before the drum in the novel design. Whereas non-ferrous metal particles are separated by falling into the splitter as a result of the force generated as soon as the particles fall on the drum. Every material that passes through the drum can be recycled as a result of moving the splitter closer to the contact point of the drum. In addition, the drum can also be used for the efficient separation of large particles since its position can be adjusted according to the size of the waste material. The performance of the novel design ECS was verified via analytical approaches, finite element analysis (FEA) and experimental studies.

Characteristics of Size-segregated Mass Concentrations of Indoor Aerosol Particles in University Buildings (대학건물 실내 에어로졸입자의 입경별 질량농도 특성)

  • Suh, Jeong-Min;Wang, Bin;Jang, Seong-Ho;Park, Jeong-Ho;Choi, Kum-Chan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.453-461
    • /
    • 2014
  • Objective: Based on the fact that fine particles are more likely to produce negative influences on the health of occupants as well as the quality of indoor air compared to coarse particles, it is critical to determine concentrations of aerosol particles with different sizes. Thus, this study focused on the size distribution and concentrations of aerosol particles in university buildings. Method: Aerosol particles in indoor air were collected from four areas: corridors in buildings(In-CO), lecture rooms(In-RO), laboratories(In-LR), and a cafeteria(In-RE). Samples were also collected from outside for comparison between the concentrations of indoor and outdoor particles. For the collection of the samples, an eight stage non-viable cascade impactor was used. Result: The average concentration of $PM_{10}$ in the samples collected from indoor areas was $34.65-91.08{\mu}g/m^3$,and the average for $PM_{2.5}$ was $22.65-60.40{\mu}g/m^3$. The concentrations of the aerosol particles in the corridors, lecture rooms, and laboratories were relatively higher than the concentrations collected from other areas. Furthermore, in terms of mass median aerodynamic diameter(MMAD), the corridors and lecture rooms had higher numbers due to their characteristics, showing $2.36{\mu}m$ and $2.11{\mu}m$, respectively. Laboratories running an electrolysis experiment showed $1.58{\mu}m$, and the cafeteria with regular maintenance and ventilation had $1.96{\mu}m$. Conclusion: The results showed that the $PM_{10}$ concentrations of all samples did not exceed indoor air quality standards. However, the $PM_{2.5}$ concentration was over the standard and, in particular, the concentration of fine particles collected from the laboratories was relatively higher, which could be an issue for the occupants. Therefore, it is important to improve the quality of the indoor air in university buildings.

Visibility Variations in Korea in the 1980s and 1990s (1980년대와 1990년대 우리나라의 시정 변화)

  • 김영성;이시혜;김진영;문길주;김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.503-514
    • /
    • 2002
  • During the past two decades, primary pollutants in the ambient air have been substantially reduced in Korea by aggressive government efforts such as the switchover to clean fuels and equipment of automobiles with a three-way catalytic converter. However, visibility impairment in Seoul and major metropolitan areas has been a stubborn problem. It is apparent that both directly emitted fine particles mainly from vehicles and secondary fine particles from photochemical reactions could contribute to this visibility impairment. In addition, Korea is located downwind of the prevailing westerlies from China and is influenced by the emissions of air pollutants in China. In order to assess this complicated problem of visibility impairment, the visibility trends for the past 17 years observed at more than 60 stations throughout the country were analyzed. The results showed that visibilities were generally the lowest in the winter morning in comparison with those in the summer afternoon as well as the annual average values. It was believed that primary pollution was principally responsible for visibility impairment in most areas. The visibility in the summer afternoon was lower in clean coastal areas along with a high level of relative humidity due to the inflow of moist air accompanied by sea breeze. Although contributions of secondary particles from photochemical reactions and long-range transport of fine particles to the visibility impairment were probable, their certain evidences were not found.

A Study on Oxidation-Resistance of Iron Nanoparticles Synthesized by Chemical Vapor Condensation Process (화학기상응축법으로 제조된 철 나노분말의 산화저항에 관한 연구)

  • Lee Dong-Won;Yu Ji-Hun;Bae Jeoung-Hyun;Jang Tae-Suk;Kim Byoung-Kee
    • Journal of Powder Materials
    • /
    • v.12 no.3
    • /
    • pp.225-230
    • /
    • 2005
  • In order to prevent the oxide formation on the surface of nano-size iron particles and thereby to improve the oxidation resistance, iron nanoparticles synthesized by a chemical vapor condensation method were directly soaked in hexadecanethiol solution to coat them with a polymer layer. Oxygen content in the polymer-coated iron nanoparticles was significantly lower than that in air-passivated particles possessing iron-core/oxide-shell structure. Accordingly, oxidation resistance of the polymer-coated particles at an elevated temperature below $130^{\circ}C$ in air was $10\~40$ times higher than that of the air- passivated particles.

Trace Metals Characterization of Respirable Dust during Yellow Sand Phenomena in Seoul Area (서울지역의 황사발생시 호흡성 분진 중 미량원소의 특성 평가)

  • 신은상;선우영
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.41-51
    • /
    • 2002
  • This research was carried out using Anderson air sampler which were set up on the roof of the Engineering College of Konkuk University at Hwayang-Dong, Kwangjin-Gu, Seoul from Aug. 1992 to foul. 1999. The results are as follows: The major component of yellow sand is soil particles based upon the observation that particles ranging from $3.3~7.0{\mu}m$ occupy 36~63%. It is certain that the increase of fine particles of respirable dust during yellow sand phenomenon in Seoul area affects the human body. The trace metals from natural sources like Al, Ca, Fe, K, Na, and Si show larger mass median diameter(MMD) values during yellow sand phenomenon than in normal situations while the values of MMD for Mn and Pb rarely changes. Noticeably, the changes in value of MMD of water soluble elements like ${NO_3}^{-}$ and ${SO_4}^{2}$ are 2.3 and 6.6 times higher during the yellow sand phenomenon compared to normal situations, respectively. This fact is regarded as decisive evidence showing that ${NO_3}^{-}$ and ${SO_4}^{2}$ in the air are attached to yellow sand and move together.

Experimental study on feasibility test for removing particles in air scouring membrane backwash water with metal membrane (금속막을 이용한 저압 막 공기병용 역세척수 처리 타당성 연구)

  • Park, No-Suk;Yoon, Sukmin;Moon, Yong-Taik;Lee, Sun-Ju;Park, Sunghyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.251-259
    • /
    • 2015
  • The main objective of this research is to study feasibility for applying metal membrane to remove particles from air scouring membrane backwash water. Also, the research was conducted to investigate the influence of polyamine coagulation on floc growth in membrane backwash water as pretreatment for removal particles. From the results of experiments for evaluating the influence of polyamine coagulation on floc growth, it was investigated that particles in the rage of $2{\sim}50{\mu}m$ grew up to $30{\sim}5,000{\mu}m$. In addition, all six metal membranes showed lower removal efficiency, which was 0.87~13.89%, in the case of no polyamine coagulant. On the other hand, in the case of injecting polyamine coagulant, those did extremely high efficiency in 56~92%. From the SEM(Scanning Electron Microscope) images of filtered wiremesh and metal foam membrane, sieve effects were predominant for liquid solid separation in wiremesh and adsorption and diffusion capture effects were predominant in metal foam membrane.