• 제목/요약/키워드: Air Operation

검색결과 2,748건 처리시간 0.034초

재생연료의 MILD연소기술 (MILD Combustion Technology for Recycled Fuel)

  • 심성훈;정상현;이상섭
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.205.2-205.2
    • /
    • 2010
  • Optimum operation conditions of low-NOx MILD combustion for gaseous and solid fuels have been investigated by experimental and computer simulation. Loop reactor type MILD combustor without air pre-heater has been used in the present work. The results show that the balance of injection velocities of fuel and surrounding air is major factor for maintaining MILD combustion mode. Temperature difference between lower and upper part can be reduced less than 20 degree of Celsius. It was found that NOx emission in MILD combustion also can be remarkably reduced to more than 85% in comparison with conventional premixed combustion, and reduced to more than 50% in case of nitrogen and carbon dioxide carrying dried waste water sludge and pulverized coal in comparison with the same of air carrying. It was also found that carbon monoxide emission increase was not appeared at the time of changeover to MILD combustion mode from premixed or air carrying combustion at optimum operation condition.

  • PDF

소형항공기의 고밀도 운용방안 연구 (The Study on Small Aircraft Transportation System in Higher Volume Opreations)

  • 김현수;유병선;강자영
    • 한국항공운항학회지
    • /
    • 제19권2호
    • /
    • pp.37-44
    • /
    • 2011
  • This paper summarizes the HVO concept and procedures, presents a summary of the research and results, and outlines areas where future HVO is required. This concept enables people to get their destinations through shortest paths with advanced air traffic control system and equipments. The concept's key feature is that pilots maintain their own separation from other aircraft using air-to-air datalink and on-board software which are needed for supporting flight information present on the high Way in the sky display and airborne internet. By assigning Self-Controlled Area which assume pilot have separation responsibility, controllers evaluated SATS HVO concept as a successful method on the view of reduced workload and increased traffic level on high volume operation.

공기 냉각 시스템의 홴 소음 예측 기법 (Fan Noise Prediction Method of Air Cooling System)

  • 이찬;길현권
    • 한국소음진동공학회논문집
    • /
    • 제18권9호
    • /
    • pp.952-960
    • /
    • 2008
  • Fan noise prediction method is presented for air conditioning, automobile and electronic cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(flow network modeling). Fan noise prediction method comprises two models for the discrete frequency noise due to rotating steady aerodynamic lift and blade interaction and for the broadband noise due to turbulent boundary layer and wake vortex shedding. Based on the fan operation point predicted from the FNM analysis results and fan design parameters, the present far noise model predicts overall sound pressure level and spectrum. The predictions for the flow distribution, the fan operation and the noise level in air cooling system by the present method are well agreed with 3-D CFD and actual noise test results.

자갈축열 태양열 온실의 공기유동 및 축열 성능 (Air Flow and Heat Storage Performance of Solar-Heated Greenhouse with Rock Bed Storage)

  • 이석건;이종원;이현우
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.275-280
    • /
    • 2001
  • The purpose of this study was to investigate the air flow characteristics of the rock bed storage for solar-heated greenhouse design. Heat storage material was gravels and experiments were performed under constant inside temperature condition. The experimental parameters were operation method and air flow rate of fan. It was resulted that the temperature and amount of heat stored in rock-bed increased as the increase of air flow velocity and were more influenced by operation of inlet fan than outlet fan.

  • PDF

소아 장중첩증에 대한 복강경 수술의 경험 (Laparoscopic Surgery for Intussusception in Children)

  • 윤두환;남소현
    • Advances in pediatric surgery
    • /
    • 제19권2호
    • /
    • pp.66-72
    • /
    • 2013
  • Intussusception is common cause of intestinal obstruction in children. Most of intussusceptions can be treated with non-operative reduction using air or barium. However, about 10% patients need operative treatment due to failure of reduction, peritonitis, and recurrence after reduction. We introduce our experience of laparoscopic surgery for intussusception. From April 2010 to March 2013, we reviewed 57 children who diagnosed intussusception. Twelve patients underwent an operation. The cause of operation was 7 of failure of air reduction and 5 of recurrence after air reduction. Median age was 21.5 months (range: 5.0~57.7 months) and 11 children (91.7%) underwent successful laparoscopic reduction. Median operating time was 50 minutes (range: 30~20 minutes) and median hospital days was 4.5 days (range: 3~8 days). One patient had a leading point as a heterotopic pancreas and underwent bowel resection through conversion. There was neither intra-operative nor postoperative complication. Laparoscopic reduction for intussusception can bring an excellent cosmetic effect with high success rate.

원주시 소각시설의 입지와 주변지역의 대기질예측에 관한 연구 - 입지여건의 평가를 중심으로 (Evaluation of Air Quality and Site Feasibility for the Construction of the Incineration Facilities in Won Ju City)

  • 송동웅;김기현
    • 한국환경과학회지
    • /
    • 제9권1호
    • /
    • pp.65-74
    • /
    • 2000
  • In this study, we investigated the site feasibility for the construction of the incineration facilities in Won Ju City. To assess the environmental impact of its construction, we examined the current status of air quality in the selected candidate sites and predicted the extent of air quality change upon its operation through modification of stack type. If the stack height is assumed to be 70 m, the concentrations of $SO_2$ and dioxin in the surrounding area were predicted to increase by 0.05 ppb and 0.09 pg/$m^3$, respectively. The impact of its operation was assessed and compared among different sites. According to this analysis, more impact was expected from the residential area for the Dan-Gye site than from agricultural areas of the Kwan-Sul and Sa-Je site.

  • PDF

지중매설관의 특성이 토양 - 공기 열교환기 성능에 미치는 영향 (Effects of Earth-Tube Characteristics on the Soil-Air Heat Exchanger Performances)

  • 김영복
    • Journal of Biosystems Engineering
    • /
    • 제22권4호
    • /
    • pp.459-468
    • /
    • 1997
  • To optimize the design and operation of a soil- air heat exchanger system, the effects of variables characterizing system design and operation on the performance of the system were analyzed by a theoretical model which included the three-dimensional transient heat conduction equation. The solution of the theoretical model was acquired by a computer program that uses Finite Difference Methods and Gauss-Seidel iteration computation, in which the time discretization scheme was an implicit difference appoximation. The computer program was validated first by comparison of the results for different grid sizes. Air outlet temperature, energy gain, and heat exchange efficiency of the system were analyzed based upon the tube diameter, tube length, tube thickness, and tube thermal diffusivity.

  • PDF

냉방기기별 경제성 평가 (Economic Evaluation of Various Cooling Systems)

  • 김영일;조금남
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.214-219
    • /
    • 2008
  • In this study, medium capacity EHP and GHP for air-conditioning a building with a floor area of $1,200\;m^2$ are compared economically. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. For the initial cost, equipment, construction, installation, electric facility, financial subsidy and tax cut are considered. Basic electricity, energy(electricity and gas), space charge, labor, insurance and repair are considered for the operation cost. Under the assumptions made in this study, overall cost of EHP is less than that of GHP. However, different outcome may result if different assumptions are made. This study is useful for performing an economic evaluation of various air-conditioning systems.

  • PDF