• Title/Summary/Keyword: Air Mouse

Search Result 73, Processing Time 0.029 seconds

Inflatable Mouse: Volume-adjustable Mouse with Air-pressure-sensitive Input and Haptic Feedback (부풀어지는 마우스: 기압센서를 이용한 입력과 햅틱 피드백을 갖는 부피가 변하는 마우스)

  • Kim, Seok-Tae;Lee, Bo-Ram;Kim, Hyun-Jung;Nam, Tek-Jin;Lee, Woo-Hun
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.323-328
    • /
    • 2008
  • Inflatable Mouse is a volume-adjustable user interface. It can be inflated up to the volume of a familiar mouse, but be deflated and stored flat in a PC card slot of a laptop computer when not in use. Inflatable Mouse functions just like a typical mouse; moreover, it provides new interaction techniques by sensing the air pressure in the balloon of the mouse. It also addresses some issues associated with pressure-sensing interactions such as the lack of bi-directional control and the lack of effective feedback. Moreover, it can be used as both a control tool and a display tool. In this paper, the design of an Inflatable Mouse prototype is described and potential application scenarios such as zooming in/out and fast scrolling using pressure control are explained. We also discuss the potential use of Inflatable Mouse as an emotional communication tool.

  • PDF

Study for Related Mechanism of Anti-Inflammatory Effect Induced by Neddle electrode electrical stimulation in Mouse Air Pouch Model. (Mouse Air Pouch Model에서 침전극 저주파치료로 유도된 소염 작용에 관한 연구)

  • Chung, Jin-Woo;Hwang, Hyun-Sook;Lim, Jong-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.2
    • /
    • pp.111-122
    • /
    • 2002
  • In oriental medicine, manual-acupuncture and electroacupuncture (EA) have been widely utilized to cure several inflammatory diseases such as arthritis. We designed this experiment to find neurochemical mechanism related to electroacupuncture induced anti-inflammatory effect on mouse air pouch model. EA with both low frequency (1 Hz) and high frequency (120 Hz) was treated after induction of inflammation in air pouch using injection of zymosan. To verify the role of opioid system in electroacupuncture-induced anti-inflammatory effect, naloxone (10 mg/kg) was pretreated. In addition, idazoxan (5 mg/kg) was pre-treated to evaluate the possible effect of endogenous adrenergic system in autonomic system on EA induced anti-inflammatory effect. As results of this study, naloxone pretreatment did not change the anti-inflammatory effect evoked by high frequency EA, while low frequency EA(1 Hz) induced anti-inflammatory effect was dramatically suppressed by naloxone pretreatment. These data indicated that endogenous opioid system might be extensively involve in anti-inflammatory effect evoked by not high frequency, but low frequency EA. However, idazoxan pretreatment did not produce any modulatory effect on both low and high frequency EA induced anti-inflammatory effect, suggesting that EA induced anti-inflammatory effect was not mediated by endogenous adrenergic system. In conclusion, these data strongly suggested that EA induced anti-inflammatory effect is mediated by endogenous opioid system, not endogenous adrenergic system.

  • PDF

A Study on the Splitting Methods in Mouse and Bovine Embryos (생쥐 및 소 수정란의 분할방법에 관한 연구)

  • 조남기
    • Korean Journal of Animal Reproduction
    • /
    • v.11 no.2
    • /
    • pp.127-131
    • /
    • 1987
  • This study was carried out to obtain the basic information on splitting and culture of mouse and bovine embryos. Two-, four-, eight-, cell and morula mouse embryos were digested with pronase, splitted in vitro by micro-glass needel with hand, and bovine embryos were splitted by micromanipulator. The splitted embryos were cultured under 5% of CO2 gas in air at 37$^{\circ}C$ for 48-72 hours. The results obtained in this study were summarized as follows: 1. The mouse and cattle were superovulated by 5IU of PMS and HCG, and 2500IU of PMS and 25mg of PGF2$\alpha$, respectively. The average number of embryos after superovulation were 32.5$\pm$8.2 and 7.5$\pm$3:1, respectively. 2. Out of total 122 embryos splitted, the successful splitting rate was 75.0%, 66.7%, 68.4% and 71.4% in 2-, 4-, 8- and morula embryos in mouse, respectively. There was no different splitting rate between mouse(71.4%) and bovine embryos(66.7%) in morula. 3. The successful culture rate of splitted embryos was 68.0% and 67.9% in mouse and bovine embryos, respectively.

  • PDF

Implementation of Arduino Air Mouse for Sniper Simulator Game (저격 시뮬레이터 게임을 위한 아두이노 에어 마우스 구현)

  • Jang, Myeong-Soo;Sim, Young-Hoon;Lee, Woo-Beom
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.2
    • /
    • pp.61-66
    • /
    • 2016
  • With the recent introduction of HMD devices, there is a growing interest in simulator games that are difficult to experience directly like a FPS, racing game. However, because these gaming require a large volume consol and a additive user manipulating devices for the more reality experience, most of these games are very expensive. Therefore, we propose the Arduino Air Mouse for a sniper simulator game, which maximizes realism and can be enjoyed with small volume and low cost devices. The implemented Arduino Air Mouse uses an acceleration sensor and gyro sensor. Specially, after this device was tested in the a sniper simulator game that is applied the ballistics in the Unity3D environment, the implemented game showed more reality.

Sexing of Mouse Embryos by Chromosomal Analysis (염색체 분석에 의한 생쥐 수정란의 성감별)

  • 한용만;김종배;박홍양;정길생;이경광
    • Korean Journal of Animal Reproduction
    • /
    • v.10 no.1
    • /
    • pp.36-41
    • /
    • 1986
  • These experiments were carried out to obtain basic information necessary for sexing embryos by chromosomal analysis. To observe metaphase chromosomes, all embryos developed to blastocysts were cultured in Ho, pp. & Pitts' medium containing 0.001% Colcemid under the gas phase of 5% CO2 in air at 37$^{\circ}C$ for 2 hours. The sex chromosome of mouse embryos shown normal development after culture in medium containing H-Y antiserum (10%, v/v) and complement (20%, v/v) also was confimed by chromosomal analysis. The results obtained in these experiments were summarized as follows: 1. Among 89 mouse blastocysts, the number of embryos identified to have XX and XY chromosome was 22(25%) and 25(28%), respectively and 42(47%) embryos were not identified. 2. Of total 40 mouse balstocysts cultured in medium containing H-Y antiserum and complement, 23(58%) embryos which were able to be discriminated their sex chromosomes were identified to be XX bearing embryos. 3. Sex chromosomes of a number of embryos subjected to chromosomal analysis were not identified. This result may be due to absence or poor quality of metaphase spreads.

  • PDF

Vibrotactile Space Mouse (진동촉각 공간 마우스)

  • Park, Jun-Hyung;Choi, Ye-Rim;Lee, Kwang-Hyung;Back, Jong-Won;Jang, Tae-Jeong
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.337-341
    • /
    • 2008
  • This paper presents a vibrotactile space mouse which use pin-type vibrotactile display modules and a gyroscope chip. This mouse is a new interface device which is not only an input device as an ordinary space mouse but also a tactile output device. It consists of a space mouse which use gyroscope chip and vibrotactile display modules which have been developed in our own laboratory. Lately, by development of vibrotactile display modules which have small size and consume low power, vibrotactile displays are available in small sized embedded systems such as wireless mouses or mobile devices. Also, development of new sensors like miniature size gyroscope by MEMS technology enables manufacturing of a small space mouse which can be used in the air not in a plane. The vibrotactile space mouse proposed in this paper recognizes motion of a hand using the gyroscope chip and transmits the data to PC through Bluetooth. PC application receives the data and moves pointer. Also, 2 by 3 arrays of pin-type vibrotactile actuators are mounted on the front side of the mouse where fingers of a user's hand contact, and those actuators could be used to represent various information such as gray-scale of an image or Braille patterns for visually impared persons.

  • PDF

Tranceplacental Effect of Air Pollutants in Seoul to inducing Micronuclei from Polychromatic Erythrocytes in Mouse Fetal Liver (서울시 대기오염물질이 마우스태자 간조직 세포의 소핵출현에 미치는 經胎盤 효과)

  • 송동빈;김수한;김영환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.111-117
    • /
    • 1990
  • To investigate the transplacental cytogenic effect of air pollutants the authors collected samples from Shinchon, Guro, Banpo and Jungnung-dongs in winter season. The air filters were extracted by mixture of benzene and ethanol, then a certain amount of extracted sustance was injected to pregnant mice at 16th day of gestation. From the fetal liver emulsion polychromatic erythrocytes were collected and stained with Giemsa solution. The cytogenic effect was evaluated by micronucleus test by which numbers of polychromatic erythrocytes containing microunclei (MNPCE) per 1, 000 polychromatic erythrocytes could be counted.

  • PDF

Implementation of non-Wearable Air-Finger Mouse by Infrared Diffused Illumination (적외선 확산 투광에 의한 비장착형 공간 손가락 마우스 구현)

  • Lee, Woo-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.167-173
    • /
    • 2015
  • Extraction of Finger-end points is one of the most process for user multi-commands in the Hand-Gesture interface technology. However, most of previous works use the geometric and morphological method for extracting a finger-end points. Therefore, this paper proposes the method of user finger-end points extraction that is motivated a ultrared diffused illumination, which is used for the user commands in the multi-touch display device. Proposed air-mouse is worked by the quantity state and moving direction of extracted finger-end points. Also, our system includes a basic mouse event, as well as the continuous command function for expending a user multi-gesture. In order to evaluate the performance of the our proposed method, after applying to the web browser application as a command device. As a result, the proposed method showed the average 90% success-rate for the various user-commands.