• Title/Summary/Keyword: Air Monitoring

Search Result 1,518, Processing Time 0.027 seconds

Evaluation of the Representativeness of Air Quality Monitoring Network in Seoul through Actual Measurement (대기오염도 실측에 의한 대기오염 자동측정망의 대표성 평가)

  • Jeon, Eui-Chan
    • Journal of Environmental Impact Assessment
    • /
    • v.5 no.1
    • /
    • pp.79-85
    • /
    • 1996
  • Simultaneous monitoring in many locations is necessary to evaluate the air quality and analyze future trend of a city, For this purpose, it is essential to install air pollution monitoring network. The first automatic air pollution monitoring network was introduced Seoul in 1973. As of 1995, 20 monitoring stations are now in operation. Concerning the management of the air pollution monitoring network, there was some argument among the relavant scholars, non-governmental organization(NGO) and the government organization. So far, there was no extensive evaluation and analysis about the network. The purpose of this study was to evaluate the representativeness of air quality monitoring network through actual measurement of the concentration of the air pollutant. The concentration of NOx was extensively measured widely in Seoul area three times using the TEA simple measuring technique. Even the judgement level for the area representativeness was lowered to 80%, Ssangmun-dong monitoring station tend to overestimate the pollutant concentration of the covered area. While, Sinlimdong monitoring station tend to underestimate the pollutant concentration of the covered area.

  • PDF

Optimization of Air Quality Monitoring Networks in Busan Using a GIS-based Decision Support System (GIS기반 의사결정지원시스템을 이용한 부산 대기질 측정망의 최적화)

  • Yoo, Eun-Chul;Park, Ok-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.526-538
    • /
    • 2007
  • Since air quality monitoring data sets are important base for developing of air quality management strategies including policy making and policy performance assessment, the environmental protection authorities need to organize and operate monitoring network properly. Air quality monitoring network of Busan, consisting of 18 stations, was allocated under unscientific and irrational principles. Thus the current state of air quality monitoring networks was reassessed the effect and appropriateness of monitoring objectives such as population protection and sources surveillance. In the process of the reassessment, a GIS-based decision support system was constructed and used to simulate air quality over complex terrain and to conduct optimization analysis for air quality monitoring network with multi-objective. The maximization of protection capability for population appears to be the most effective and principal objective among various objectives. The relocation of current monitoring stations through optimization analysis of multi-objective appears to be better than the network building for maximization of population protection capability. The decision support system developed in this study on the basis of GIS-based database appear to be useful for the environmental protection authorities to plan and manage air quality monitoring network over complex terrain.

Feasibility Study for the Location of Air Quality Monitoring Network in Daegu Area (대구지역 대기오염자동측정망 위치의 타당성 분석)

  • Choi, Sung-Woo;Lee, Jung-Beom
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.81-91
    • /
    • 2011
  • Air quality monitoring networks are very important facilities to manage urban air pollution control and to set up an environmental policy. Since air quality monitoring network of Daegu was allocated from 1980s to mid-90s, there is need to reevaluate it and relocated its site. This study was evaluated the position of Daegu air quality monitoring station by unit environmental sensitivity index, grid emission rate, CAI (Comprehensive Air-quality Index) point. The investigation domain covered an area of 16 $\times$ 24 km centered at the metropolitan area of Daegu with grid spacing of 2 km. The location of alternative air quality monitoring networks was selected through optimization and quintiles analysis of total score. The result showed that all things considered, new air quality monitoring network need to install grid numbers 10, 28, 36, 37, 46. We also recommand three scenarios of alternative air quality monitoring network when considering unit environmental sensitivity index, emission rate and CAI point.

Applications of Drones for Environmental Monitoring of Pollutant-Emitting Facilities

  • Son, Seung Woo;Yu, Jae Jin;Kim, Dong Woo;Park, Hyun Su;Yoon, Jeong Ho
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • v.2 no.4
    • /
    • pp.298-304
    • /
    • 2021
  • This study aimed to determine the applicability of drones and air quality sensors in environmental monitoring of air pollutant emissions by developing and testing two new methods. The first method used orthoimagery for precise monitoring of pollutant-emitting facilities. The second method used atmospheric sensors for monitoring air pollutants in emissions. Results showed that ground sample distance could be established within 5 cm during the creation of orthoimagery for monitoring emissions, which allowed for detailed examination of facilities with naked eyes. For air quality monitoring, drones were flown on a fixed course and measured the air quality in point units, thus enabling mapping of air quality through spatial analysis. Sensors that could measure various substances were used during this process. Data on particulate matter were compared with data from the National Air Pollution Measurement Network to determine its future potential to leverage. However, technical development and applications for environmental monitoring of pollution-emitting facilities are still in their early stages. They could be limited by meteorological conditions and sensitivity of the sensor technology. This research is expected to provide guidelines for environmental monitoring of pollutant-emitting facilities using drones.

Evaluation and Complement of the Representativeness of Air Quality Monitoring Stations Using Passive Air Samplers (수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방완에 대한 기초연구)

  • 우정현;김선태;김정욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.6
    • /
    • pp.415-426
    • /
    • 1997
  • Some arguments have been about over the representativeness of government-run air quality monitoring stations among scholars and non-governmental organizations (NGOs). However, it is not a simple problem to move monitoring stations because of continuity of data and high cost. So it is necessary to complement the monitoring data if it do not represent the ambient air quality properly. The purpose of this study was to evaluate the representativeness of some monitoring stations using passive $NO_2$ samplers and to find a complementary method from linear regression. Two stations were chosen for the evaluation: Shinlim Station was one of the most controversial stations in Seoul and Banpo Station had the best reputation. Air qualities were surveyed at seven points around each monitoring station with consideration of land use and distance. The ratios of the average $NO_2$ levels of the areas to these at the monitoring stations were 1.59 for Shinlim Station and 1.03 for Banpo Station. The differences between the average $NO_2$ levels and those at the monitoring stations were 10.75 ppb for Shilim Station and 0.34 ppb for Banpo Station. The correlation coefficients between the two levels were 0.7668 for Shinlim and 0.7662 for Banpo. The average coefficients of determination $(R^2)$ were 0.61 for Shinlim and 0.61 for Banpo. The Shinlim Station could not represent the air quality of Shinlim-Dong good because it is located in a green area at an outskirt of Shinlim-Dong. But the Banpo Station located in a central residential area of Banpo-Dong showed a fair representativeness. However, air quality turned out to be different with land use such as residential area, green area or road: the air quality data from a monitoring station located at a certain land use should not be interpreted as representing the air quality at any sites around the station. Equations to predict the average $NO_2$ levels of each area from the data from the monitoring stations were presented based on linear regression.

  • PDF

Evaluation of Air Pollution Monitoring Networks in Seoul Metropolitan Area using Multivariate Analysis (다변량분석법을 활용한 수도권지역의 대기오염측정망 평가)

  • Choi, Im-Jo;Jo, Wan-Keun;Sin, Seung-Ho
    • Journal of Environmental Science International
    • /
    • v.25 no.5
    • /
    • pp.673-681
    • /
    • 2016
  • The adequacy of urban air quality monitoring networks in the largest metropolitan city, Seoul was evaluated using multivariate analysis for $SO_2$, $NO_2$, CO, PM10, and $O_3$. Through cluster analysis for 5 air pollutants concentrations, existing monitoring stations are seen to be clustered mostly by geographical locations of the eight zones in Seoul. And the stations included in the same cluster are redundantly monitoring air pollutants exhibiting similar atmospheric behavior, thus it can be seen that they are being operated inefficiently. Because monitoring stations groups representing redudancy were different depending on measurement items and several pollutants are being measured at the same time in each air monitoring station, it is seemed to be not easy to integrate or transmigrate stations. But it may be proposed as follows : the redundant stations can be integrated or transmigrated based on ozone of which measures are increasing in recent years and alternatively the remaining pollutants other than the pollutant exhibiting similar atmospheric behavior with nearby station's can be measured. So it is considered to be able to operate air quality monitoring networks effectively and economically in order to improve air quality.

MEMS/Nano-technologies for Smart Air Environmental Monitoring Sensors

  • Park, Inkyu;Yang, Daejong;Kang, Kyungnam
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.281-286
    • /
    • 2015
  • The importance of air quality monitoring is rapidly increasing. Even though state-of-the-art air quality monitoring technologies such as mass spectrometry, gas chromatography, and optical measurement enable high-fidelity measurement of air pollutants, they cannot be widely used for portable or personalized platforms because of their high cost and complexity. Recently, personalized and localized environmental monitoring, rather than global and averaged environmental monitoring, has drawn greater attention with the advancement of mobile telecommunication technologies. Here, micro- and nano-technologies enable highly integrated and ultra-compact sensors to meet the needs of personalized environmental monitoring. In this paper, several examples of MEMS-based gas sensors for compact and personalized air quality monitoring are explained. Additionally, the principles and usage of functional nanomaterials are discussed for highly sensitive and selective gas sensors.

A Low Power Wireless Communication-based Air Pollutants Measuring System (저전력 무선통신 기반 대기오염 측정시스템)

  • Kang, Jeong Gee;Lee, Bong Hwan
    • Journal of Information Technology Applications and Management
    • /
    • v.28 no.6
    • /
    • pp.87-95
    • /
    • 2021
  • Recently interest for air pollution is gradually increasing. However, according to the environmental assessment of air quality, the level of air pollution in the nation is quite serious, and air pollutants measuring facilities are also not enough. In this paper, a secure air pollutants sensor system based low power wireless communication is designed and implemented. The proposed system is composed of three parts: air pollutants measuring sensors module, LoRa-based data transmission module, and monitoring module. In the air pollutants measuring module, the MSP430 board with six big air pollutants measuring sensors are used. The air pollutants sensing data is transmitted to the control server in the monitoring system using LoRa transmission module. The received sensing data is stored in the database of the monitoring system, and visualized in real-time on the map of the sensor locations. The implemented air pollutant sensor system can be used for measuring the level of air quality conveniently in our daily lives.

Method for Evaluating Optimal Air Monitoring Sites for SO2 in Ulsan (울산광역시 아황산가스(SO2)의 최적관측소 평가방법)

  • Lim, Junghyun;Yoon, Sanghoo
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1073-1080
    • /
    • 2017
  • Manufacturing and technology industries produce large amounts of air pollutants. Ulsan Metropolitan City, South Korea, is well-known for its large industrial complexes; in particular, the concentration of $SO_2$ here is the highest in the country. We assessed $SO_2$ monitoring sites based on conditional and joint entropy, because this is a common method for determining an optimal air monitoring network. Monthly $SO_2$ concentrations from 12 air monitoring sites were collected, and the distribution of spatial locations was determined by kriging. Mean absolute error, Root Mean Squared Error (RMSE), bias and correlation coefficients were employed to evaluate the considered algorithms. An optimal air monitoring network for Ulsan was suggested based on the improvement of RMSE.

A study on BEMS-linked Indoor Air Quality Monitoring Server using Industrial IoT

  • Park, Taejoon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.65-69
    • /
    • 2018
  • In this paper, we propose an interworking architecture for building indoor air quality monitoring server (BEMS) using IIoT (Industrial Internet of Things). The proposed monitoring server adopts IIoT-based standard protocol so that interaction with BEMS installed in existing buildings can be performed easily. It can effectively communicate with indoor air quality measurement sensor installed in the building based on IIoT, Indoor air quality monitoring is possible. We implemented a proposed monitoring server, and confirmed the availability and monitoring of data from sensors in the building.