• 제목/요약/키워드: Air Injection

검색결과 1,199건 처리시간 0.026초

수직상향 기체 주입에 따른 기포 및 액상의 유동분석 (Flow Analysis of Bubble and Liquid Phase by Vertical Upward Gas Injection)

  • 서동표;오율권
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.727-732
    • /
    • 2003
  • In the present study, a PIV measurement and image processing technique were applied in order to investigate the flow characteristics in the gas injected liquid bath. The circulation of liquid was induced by upward bubble flow. Due to the centrifugal force, the flow was well developed near both wall sides than in the center of a bath. The vortex flow irregularly repeated generation and disappearance which helped to accelerate the mixing process. The bubble rise velocity in the bottom region was relatively lower than in the upper region because the energy generated by bubbles' behavior in the region near the nozzle was almost converted into kinetic energy But bubble rise velocity increases with the increase of the axial distance since kinetic energy of rising bubbles is added to buoyancy force. In conclusion, the flow increased bubble rise velocity and the flow of the bottom region became more active.

5 kW급 SOFC 시스템의 연료 개질기를 위한 2-유체 노즐과 3-유체 노즐의 검토 (Examination of 2-Fluid Nozzle and 3-Fluid Nozzle for Fuel Reformer of 5 kW SOFC System)

  • 권화길;이치영;이상용
    • 한국분무공학회지
    • /
    • 제13권1호
    • /
    • pp.16-21
    • /
    • 2008
  • In the present study, the 2-fluid nozzle and 3-fluid nozzle to atomize the diesel and water with air for the fuel reformer of SOFC system were experimentally examined. In the 2-fluid nozzle, the diesel and water were alternately atomized due to bislug flow pattern, and it implies that the mixing of both liquids strongly affects the atomization pattern. On the other hand, in the 3-fluid nozzle, the diesel and water were atomized simultaneously due to the separated injection channels without mixing problem. Therefore, compared to the 2-fluid nozzle, the 3-fluid nozzle is suitable for the stable operation of the fuel reformer. In case of the 3-fluid nozzle, Type A where the air was supplied through the central channel was the most efficient.

  • PDF

엔진 부분 부하 성능 및 변속기 시프트맵을 이용한 차량주행성능 컴퓨터 시뮬레이션 (A Computer Simulation of a Driving Vehicle Performance using an Set of Engine Part Load Performance and a Transmission Shift Map)

  • 이충훈
    • 한국분무공학회지
    • /
    • 제19권2호
    • /
    • pp.64-68
    • /
    • 2014
  • A driving vehicle performance which is driven by FTP-75 mode was simulated by computer. Throttle valve position, engine speed, air mass flow rate, fuel consumption et al. were computer simulated. A set of engine part load performance data, automatic transmission shift map and vehicle specifications were used for the computer simulation. Throttle valve position, engine speed, air mass flow rate et al. measured for evaluating the computer simulation results by driving the vehicle with FTP-75 mode on a chassis dynamometer. GT-Power$^{(R)}$ software was used for the computer simulation of the driving vehicle performance. Experimental fuel consumption rate was measured by using an ECU HILS fuel injection system. The experimental data and simulation results were compared. The computer simulation of the driving vehicle performance predicts the measured data well comparatively.

NOx Emissions in Flameless Combustion of Kerosene-Air Mixture Jets Injected into Hot Burned Gas Stream from Combustion Wall

  • Aida, Naoki;Hayashi, Shigeru;Yamada, Hideshi;Kawakami, Tadashige
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.449-452
    • /
    • 2004
  • “Flameless combustion” of lean to ultra lean mixtures, supported by high-temperature burned gas, can resolve the dilemma between complete combustion versus ultra-low NOx emissions in gas turbine combustors. The characteristics of NOx emissions and combustion in “lean-lean” two-stage combustion were investigated for fuel vapor and droplets / air mixture jets injected from the main injection tube that was placed perpendicular to the combustor wall into the primary hot burned gas prepared by combustion of lean mixtures on a perforated flame holder. The present results clearly show that the ultra-low NOx combustion supported by the reaction of lean mixtures well mixed with the hot burned gas from the primary stage is much more advantageous in achieving ultra-low NOx emissions while maintaining high combustion efficiency.

  • PDF

Study on the Fundamental Technologies of ATREX Engine

  • Sato, Tetsuya;Kobayashi, Hiroaki;Tanatsugu, Nobuhiro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.665-670
    • /
    • 2004
  • This paper reviews the latest studies of the expander cycle Air Turbo Ramjet engine (ATREX) conducted in JAXA. First, a system analysis including the vehicle and trajectory was conducted to optimize the engine cycle and turbo-machine configuration. We selected the precooled turbo-jet cycle for a prototype engine using the near term technologies. Second, a system ground-firing test was conducted to verify a defrosting system for the precooler. Methanol injection with its particles atomization could compensate 80 % of pressure loss caused by the frost. Thirdly, a feasibility of carbon/carbon composites for the engine components was investigated by making complex shapes such as a heat exchanger and a plug nozzle. Basic technologies on the gas leakage, the junction and bonding were also studied. The end of the paper, some basic studies such as wind tunnel tests of a new type air inlet and a plug nozzle are described.

  • PDF

원자로 비상 냉각재 누설에 의한 열성층의 비정상 특성에 관한 연구 (Study of Thermal Stratification into Leaking Flow in the Nuclear Power Plant, Emergency Core Coolant System)

  • 한성민;최영돈;박민수
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.202-210
    • /
    • 2006
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can be occurred due to coolant leaking in the check valve. The thermal stratification produces excessive thormal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, when the turbulence penetration occurs in the branch pipe, the maximum temperature differences of fluid at the pipe cross-sections of the T-branch with thermal stratification are examine.

원관내 난류의 저항감소현상에 대한 수치해석 (Numerical analysis of drag reduction of turbulent flow in a pipe)

  • 홍성진;김광용;최형진
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.733-739
    • /
    • 1999
  • A modified low-Re $k-\varepsilon$ model is used for the calculation of drag-reducing turbulent flow by polymer injection in a pipe. With the viscoelastic model, molecular viscosity in the definition of turbulent viscosity is related to elongations viscosity of the solution to account for the effects of drag reduction. Finite volume method is used for the discretization, and power-law scheme is used as a numerical scheme. Computed dimensionless velocity profiles are in good agreements with the experimental data in case of low drag reductions. However, in case of high drag reductions, they deviate largely from the measurements in the central zone of the flow field.

  • PDF

충돌면 경사각도 변화에 따른 분무특성 (Spray Characteristics Depending Upon Impaction Land Surface Angle Variations)

  • 김재휘;김진환;박권하
    • 한국자동차공학회논문집
    • /
    • 제6권6호
    • /
    • pp.63-71
    • /
    • 1998
  • In a diesel engine the phenomenon of spray impaction on a combustion chamber wall has been taken as an undesirable matter because of the deposition of fuel on the surfaces, and the subsequent slow evaporation and mixing with air resulting in unburned hydrocarbons. Therefore many researches have concentrated on avoiding fuel impaction on surfaces. On the contrary done a number of studies using spray wall impactions in a positive way, which makes the droplets smaller, changes the direction into free spaces far from the wall and also improves mixing with air. In this paper the angle variations of the impaction land sufrace prepared for the injection spray is analysed as a simulative manner. The spray dispersions, vapor distributions and flow fields are compared with impacting angle variation. The results show more angle give more vapor distribution until $15^{\circ}$.

  • PDF

OSKA형 디젤기관 연소실의 충돌면 크기 분석 (The Size Analysis of Raised Lands Prepared for Spray Impaction in OSKA Typed D.I. Diesel Engine Combustion Chamber)

  • 김재휘;홍영표;박권하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권3호
    • /
    • pp.82-90
    • /
    • 1996
  • In a diesel engine the phenomenon of spray impaction on a chamber wall has been taken as an undesirable matter because of the deposition of fuel on the surfaces, and the subsequent slow evaporation and mixing with air resulting in unburned hydrocarbons. Therefore many researches have concentrated on avoiding fuel impingement on surfaces. On the contrary done a number of studies using spray wall impactions in a positive way, which makes the droplets smaller, changes the direction into free spaces far from the wall and also improves mixing with air. In this paper the size of the impaction site prepared for the injection spray which is raised from the bottom in the piston bowl center is analysed as both simulative and experimental manner.

  • PDF

이코노마이저를 채용한 스크류 냉동기에서 R22와 R407C의 부분부하 성능실험 (Part-Load Performance Test of a Screw Chiller with Economizer using R22 and R407C)

  • 장영수;이용철;김영일
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.902-909
    • /
    • 2003
  • Screw compressor type chillers are widely used in refrigeration for capacity over 30 RT. In general, chillers operate under part-load conditions. Therefore, information on characteristics at part-load is very important in view of chiller performance and energy economy. In this study, performance tests of part-load and economizer system using R22 and R407C have been performed for various secondary fluid temperatures. Adoption of an economizer system increased the cooling capacity and improved COP except for lower part-load condition when injection volume ratio is 1.01. For the same cooling capacity condition at part-load, COP of both non-economizer and economizer system showed similar values.