• 제목/요약/키워드: Air Environment Index

검색결과 284건 처리시간 0.028초

한국형 체감온도지수 개발연구(III) - 체감온도지수 개발을 위한 본실험 - (A Study of the Development of a Korea Wind Chill Temperature Index(III) - Principal Experiment for Development of the Korea Wind Chill Temperature Index -)

  • 박종길;정우식;김병수;윤숙희;이종태;김은별;박길운;김석철;정경석
    • 한국환경과학회지
    • /
    • 제17권10호
    • /
    • pp.1093-1109
    • /
    • 2008
  • This paper aims to provide a fundamental basis for the improvement and verification of existing wind chill temperature index through the observation of skin temperature change of human body with air temperature and wind speed. For this, we control air temperature $5^{\circ}C$ interval from $0^{\circ}C$ to $-20^{\circ}C$ and classify wind speed by 0, 2, 6 and 8 m $s^{-1}$ respectively. The results are as follows; At each combination of air temperature and wind speed, the reduction rate of the mean skin temperature are different. When our body is exposed to the atmosphere, the mean skin temperature decreases at an exponential rate. The duration of the steady state is more than one hour, while it decreases with strong wind speed. Among 4 sites on a face, the skin temperature of forehead is the highest, followed by one of chin, left cheek, right cheek in orders. Especially, since the skin temperature of right cheek is the lowest, we think that it is suitable to use the data set of the right cheek skin temperature for the development of a Korea wind chill temperature index as a worst case.

도심 산지형 공원 능선부 식생유형에 따른 공기이온 평가 - 충주시 탄금대 공원을 대상으로 - (Evaluation of Air Ion According to the Type of Ridge in Urban Park -Focused on Tangeumdae Park in ChungJu-)

  • 김정호;이상훈;윤용한
    • 한국환경생태학회지
    • /
    • 제33권5호
    • /
    • pp.587-595
    • /
    • 2019
  • 도심 산지형 공원 내 식생유형별 요인이 공기이온에 미치는 영향력을 파악하고자 충주시 탄금대 공원을 대상으로 수행하였다. 측정지점은 능선부 내 수종, 흉고직경, 울폐도, 층위구조에 따라 설정하였으며, 기상요소와 공기이온을 측정하였다. 공기이온 측정결과, 양이온 발생량은 평균 $610.90{\pm}50.27ea/cm^3$, 음이온 발생량은 평균 $723.58{\pm}64.25ea/cm^3$, 이온지수는 $1.19{\pm}0.10$이였다. 식생유형에 따른 분석결과는 다음과 같다. 첫째, 공기이온은 수종, 흉고직경, 층위구조에 따라 차이가 발생하였으며, 통계적으로 유의한 것으로 분석되었다. 둘째, 이온지수와 식생유형과의 관계에서 수종, 흉고직경, 울폐도, 층위구조 모두에서 정의 상관관계로 분석되었으며, 양이온의 경우 수종, 흉고직경, 울폐도와 부의 상관관계, 음이온의 경우 수종, 흉고직경, 울폐도, 층위구조에서 정의 상관관계로 분석되었다. 셋째, 능선부 내 이온지수의 영향요인은 기상요인과 식생유형을 비교한 결과 식생유형의 상관계수가 더 높았으며, 세부적으로는 수종 > 층위구조 > 울폐도 > 흉고직경의 순이었다. 본 연구에서는 능선부를 대상으로 공기이온을 평가한 한계점이 존재한다. 이에 향후 공기이온에 대한 연구에서 지형구조, 식생유형을 모두 고려한 분석이 이루어져야할 것이며, 계절에 따른 변화 비교연구가 필요할 것으로 판단되었다.

Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • 센서학회지
    • /
    • 제12권1호
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..

대형 빌딩근무자의 Building Symptom Index(BSI) 평가 (A study on Building Symptom Index of Workers in Large Buildings)

  • 오인숙;박성은;양지연;신동천
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 1999년도 추계학술대회 논문집
    • /
    • pp.295-296
    • /
    • 1999
  • 경제발전과 건축기술의 진보로 인해 건물이 고층화, 대형화되어 실내공간을 이용하는 시간이 늘어나면서 실내공기 오염문제가 대두되고 있다. 특히, 사람은 하루 중 80% 이상의 시간을 실내에서 생활하고 있으므로 실내공기오염이 인체에 미치는 영향은 매우 중요하다고 할 수 있다. (중략)

  • PDF

하층대기의 연직 안정도 지표를 이용한 차량 2부제의 수도권 대기오염도 저감효과 분석 (Evaluation of the Effect of Traffic Control Program on the Ambient Air Quality in Seoul Metropolitan Area Using the Lower Level Stability Index of Atmosphere)

  • 김철희;박일수;이석조;김정수;홍유덕;한진석;진형아
    • 한국대기환경학회지
    • /
    • 제21권2호
    • /
    • pp.243-257
    • /
    • 2005
  • The effects of Traffic Control Program (TCP) on the ambient urban air quality of SO$_{2}$, NO$_{2}$, O$_{3}$, and PM$_{10}$ were evaluated in Seoul metropolitan area by using the lower atmospheric vertical stability index and daily mean wind speeds. The vertical stability index; temperature lapse rate between 1000 hPa and 850 hPa geopotential height fields, were used to identify daily vertical stability index during the 2002 World Cup period where traffic amount was reportedly reduced to half the number of vehicles. The indicated air quality levels of TCP days were then compared with those of the cases observed with analogous vertical stability during the recent 3 years from 2000 to 2002. The result indicates that the effect of TCP on the primary air pollutants are found to be approximately 39$\%$, 23$\%$ and 20$\%$ lower for SO$_{2}$, NO$_{2}$ and PM$_{10}$, respectively. The secondary air pollutant; ozone, showed relatively smaller decreasing rate (13$\%$) of daily mean concentrations (even increased during the night time). The comparison of daily maximum or peak concentrations reveals that the pronounced decreasing effects of TCP on the ambient air quality for both primary and secondary air pollutants, suggesting that TCP is one of the effective strategies to control peak or higher concentrations for most urban scale air pollutants in and around the Seoul metropolitan area.

서식지 적합지수를 이용한 근소만 갯벌 바지락(Ruditapes philippinarum)의 어장적지평가 (Site Assessment Using Habitat Suitability Index for Manila Clam Ruditapes philippinarum in Geunso Bay Tidal Flats)

  • 최용현;홍석진;전승렬;조윤식
    • 한국수산과학회지
    • /
    • 제52권5호
    • /
    • pp.511-518
    • /
    • 2019
  • Evaluating the habitat suitability of potential aquaculture sites for cultured species is critical to the sustainable use of tidal flats. This study evaluated the habitat suitability index (HSI) of 12 sites in a tidal flat aquaculture farm at Geunso Bay, Taean, in June 2016. The parameters used to model the suitability index were Growth (water temperature, chlorophyll ${\alpha}$, hydrodynamics), Survival (sediment-sand, mean size, air exposure), and Environment (DO, salinity). The HSI was calculated using weighted and No weighted geometric means. The results showed high habitat suitability at the bay's entrance (HIS; No weighted, 0.60-0.70; weighted, 0.60). Hydrodynamics, air exposure, sediment-sand and mean size are thought to have a significant impact on habitat selection by Manila clams Ruditapes philippinarum. This study explored the optimum habitat for Manila clams by calculating the HSI, providing basic data for tidal flat management.

도시 가로수의 증산 작용으로 인한 불쾌지수 변화 분석 (Analyzing Change of Discomfort Index for Transpiration of Street Tree)

  • 윤석환;이동근;박채연
    • 한국환경복원기술학회지
    • /
    • 제23권5호
    • /
    • pp.29-43
    • /
    • 2020
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. The cooling effect of street tree is regarded as a effective way to ameliorate the urban heat environment. The effect is largely made up of shadow formation and transpiration. This study aims to identify how the transpiration affects the discomfort index by analyzing comprehensive impact of the transpiration on the air temperature and relative humidity. The changes in the amount of transpiration, air temperature, and relative humidity were estimated for Seogyo-dong area which has a lot of floating population in Seoul, at 2 p.m. in dry day in July and August. On average, the transpiration of the street tree decreased the temperature 0.3℃ and increased the relative humidity 2.6% in an hour. As a result of these changes in temperature and humidity, the discomfort index rose mostly(0.036 on average). It was always get rise especially on the day when the discomfort index was above 80(0.05 on average). However, compared with the significant change in temperature and humidity, the variation of the discomfort index itself was very slight(up to 0.107). Therefore, the effect of transpiration by the street trees might not be effective in the planning to improve the thermal environment(especially on the day when the discomfort index is high). It is necessary to select the species of trees and planting location considering the cooling effect of shade formation synthetically.

슬러지의 성상이 DAF(Dissolved Air Flotation)를 이용한 팽화 슬러지 농축에 미치는 영향 (Effect of Sludge Characteristics on the Thickening of Bulking Sludge using DAF (Dissolved Air Flotation))

  • 김동석;박영식
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.97-103
    • /
    • 2006
  • Excess sludge treatment and disposal currently represent a rising challenge for domestic or wastewater treatment plants due to economic, environmental and regulation factors. Conventional gravity sedimentation process has been widely used in sludge thickening. The operation method of the process is very simple, but the process requires long detention time for sludge thickening, uses polymers, and shows low sludge thickening efficiency. To solve the problems, we studied on DAF (Dissolved Air Flotation) system. We use bulking sludge of a paper manufacturing plant. The effects of parameters such as SVI (Sludge Volume Index), storage time, initial concentration and wet density of excess sludge were examined. The results showed that the more SVI was low, the more sludge was thickened. As storage time goes by, SVI was increased and thickening performance was deteriorated. In order to improve flotation performance at high concentration, high recycling ratio and pressure did not increase the concentration due to thickening limitation. The addition of 0.8 g/L of loess was increased flotation efficiency of 1.41 times.

지하역사 승강장 열환경 개선을 위한 연구 (제2보: 도입외기온도에 따른 승강장 열환경) (The study for thermal environment improvement at subway station platform (Part 2: Thermal environment according to supply outdoor temperature))

  • 김회률;김동규;금종수;정용현;김종열;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.561-564
    • /
    • 2009
  • This study is to examine the possibility of pre-cooling at platform. Through measurement of the thermal environment of Bujeon Subway platforms, review the potential use of ground-water and night purge. The results of this research can improve the thermal environment pre-cooling of the design.

  • PDF