• Title/Summary/Keyword: Air End

Search Result 840, Processing Time 0.03 seconds

PFC Bridge Converter for Voltage-controlled Adjustable-speed PMBLDCM Drive

  • Singh, Sanjeev;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.215-225
    • /
    • 2011
  • In this paper, a buck DC-DC bridge converter is used as a power factor correction (PFC) converter for feeding a voltage source inverter (VSI) based permanent magnet brushless DC motor (PMBLDCM) drive. The front end of the PFC converter is a diode bridge rectifier (DBR) fed from single phase AC mains. The PMBLDCM is used to drive the compressor of an air conditioner through a three-phase voltage source inverter (VSI) fed from a variable voltage DC link. The speed of the air conditioner is controlled to conserve energy using a new concept of voltage control at a DC link proportional to the desired speed of the PMBLDC motor. Therefore, VSI operates only as an electronic commutator of the PMBLDCM. The current of the PMBLDCM is controlled by setting the reference voltage at the DC link as a ramp. The proposed PMBLDCM drive with voltage control-based PFC converter was designed and modeled. The performance is simulated in Matlab-Simulink environment for an air conditioner compressor load driven through a 3.75 kW, 1500 rpm PMBLDC motor. To validate the effectiveness of the proposed speed control scheme, the evaluation results demonstrate improved efficiency of the complete drive with the PFC feature in a wide range of speed and input AC voltage.

A Novel Development of Distributed Intelligent Control Module Based on the LonWorks Fieldbus for Air Handling Units in the Healing, Ventilating and Air Conditioning (LonWork fieldbus 기반을 가진 HVAC 공기조화기용 고성능 지능형제어모듈 개발)

  • 홍원표
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.115-121
    • /
    • 2004
  • In this paper, a new distributed intelligent control module based on LonWoks fieldbus for air handling unit(AHU) of heating, ventilating and air-conditioning(HVAC) is proposed to replace with a conventional direct digital control(DDC) system with 32 bit microprocessor. The proposed control architecture has a excellent features such as highly compact and flexible function design, a low priced smart front-end and reliable performance with various functions. This also addresses issues in control network configuration, logical design of field devices by S/W tool, Internet networking and electronic element installation. Experimental results for showing the system performance are also included in this paper.

A Study on the Clamping Force of an Automotive Air-conditioning Hose according to the Friction Coefficient (마찰계수를 고려한 자동차용 에어컨 호스의 체결력에 관한 연구)

  • Baek, Jae-Kwon;Kim, Byung-Tak
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.39-46
    • /
    • 2011
  • The automotive air conditioning hose is used for connecting the components of air conditioner in a vehicle. The hose is usually manufactured by the swaging process to connect the rubber hose with the metal fitting at the end of the hose. In case that the clamping force is small, the refrigerant gas in the hose can leak locally under the severe operating circumstances. The practical test of clamping force is performed by means of the measurement of separation force. In this study, the swaging process of a hose is simulated with the finite element method, to investigate the effect of friction coefficient on the clamping force. The contact condition is used in consideration of real manufacturing process, and the material properties for the Mooney-Rivlin model is obtained by the experimental results. The result interpretations are focused on the contact forces, which is displayed graphically with respect to friction coefficient, on the surfaces between the hose and the metal fittings.

Influence of Initial Water Content, Specific Surface, Air Drying and Freezing-thawing Action on the Liquid Limit of Soils (초기함수비, 비표면적, 풍건 및 동결.융해작용이 흙의 액성한계에 미치는 영향)

  • 류능환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.5
    • /
    • pp.116-124
    • /
    • 1996
  • The purpose of The work described in this paper is to clear up the initial moisture content, specific surface, air drying and freezing-thawing process on liquid limit of clayey soils distributed widely at estuary of three main rivers in the west coast. To this end, a series of tests were conducted on clayey soils samples with natural state and treated state. From the test results, the liquid limit was decreased with decrement of initial moisture content, air drying process, and freezing-thawing cycles and increased with increment of specific surface. The specific surface which influenced on the liquid limit is over $25 m^2$m$^2$/g, and their relationships are well formulated. Air drying process is expected to improve the engineering properties of the soils such the pro-water properties were changed to anti-water proper-ties through lowering of water holding as resulted to incline from A-7-5 to A-5 on the soil classificaction plastic chart. The freezing-thawing process decreased 20% of liquid limit, especially under the first cycle of the behavious, as a result of above mentioned reasons, phase change of soil-water system brought the decrement of specific surface and affected to the liquid limit.

  • PDF

A Review on the Atmospheric Concentrations of Polycyclic Aromatic Hydrocarbons (PAHs) in Asia Since 2000 - Part II: Data from Developing Countries

  • Suvarapu, Lakshmi Narayana;Seo, Young-Kyo;Cha, Yoon-Chang;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.3
    • /
    • pp.169-191
    • /
    • 2012
  • This review paper describes the ambient air PAH concentrations in different developing Asian countries, including China, Afghanistan, India, Malaysia, Turkey, Vietnam, Sri Lanka, Thailand and Cambodia. In this study, more than 75 research papers published in the English literature were reviewed with respect to the seasonal and locational concentrations of PAHs in each of 9 different Asian countries. This study compared, discussed and tabulated the PAH concentrations in developing Asian countries over a one decade (2000-2011) period. The PAH concentrations measured in developing countries highlights the necessity to improve the air quality in those countries. Compared to the developed nations in Asia, developing countries are almost one decade away from implementing environmental policies, such as Euro standards. This review discusses the reasons for the high PAH concentrations in developing nations particularly in China and India. Based on the literature available, some suggestions are made to reduce the concentrations of PAHs in the ambient air of developing nations. The total data obtained from the literature survey is tabulated and presented as supplementary information at the end of the manuscript.

Thermal Regime of a Cold Talus Slope in Uiseong Binggye-ri Ice Valley, Korea (의성 빙계리 얼음골의 저온 현상에 관한 연구)

  • Seo, Kwang-Su;Hwang, Soo-Jin
    • Journal of Environmental Science International
    • /
    • v.27 no.3
    • /
    • pp.155-165
    • /
    • 2018
  • Observations were conducted in Uiseong Binggye-ri Ice Valley of Korea, where a low temperature talus is located. The talus temperature at Ice Hole near the lower end of the talus remained at $0^{\circ}C$ until summer or autumn and averaged $-0.3^{\circ}C$ over 2 years. The talus temperature at Warm Hole was much higher than the external air temperature during autumn and winter. The outflow of warm air at Warm Hole begins in the late summer of fall. The direction of airflow through the talus surface was determined by the relationship between talus temperature and external air temperature. Annual variations in talus temperature and air exchange between the talus and the external environment can be divided into four periods. It was found that the airflow directions at Warm Hole and Ice Hole were not necessarily opposites. The outflows from the talus at Ice Hole and Warm Hole can occur simultaneously.

An Approach to the Design Parameter of Air-Cored Superconducting Synchronous Generator (공심형 초전도 동기발전기의 설계변수에 대한 연구)

  • Jo, Young-Sik;Hong, Jung-Pyo;Lee, Ju;Sohn, Myung-Hwan;Kwon, Young-Kil;Ryu, Kang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.3
    • /
    • pp.101-106
    • /
    • 2001
  • Air-cored superconducting synchronous generator(ASSG) is characterized by an air-cored machine with its rotor iron and stator iron teeth removed. For this reason, in the case of the shape optimum design of ASSG, other design variables different from an iron-cored machine should be considered, which will lead to substantial improvement on the performance. The major design variables that are considered by using Three-dimensional Finite element Method(3D FEM) in this paper are : 1) field coil width, 2) axial length of magnetic shield, and 3) armature winding method. End-ring of armature winding is considered in the calculation of EMF. When it comes to field coil width, as field coil width enlarges, its effective field increases but the maximum field on the superconductor decreases. this determines the critical current density. this study presents an effective field coil width, axial length of magnetic shield, and armature winding method, and also the analysis is verified by the experimental results.

  • PDF

Surveillance-based Risk Assessment Model between Urban Air Mobility and Obstacles (도심 항공 모빌리티와 장애물 간의 감시장비 기반 충돌 위험도 평가모형)

  • Kim, Dongsin;Lee, Keumjin
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.30 no.3
    • /
    • pp.19-27
    • /
    • 2022
  • Urban Air Mobility is expected to resolve some problems in urban transportation such as traffic congestion and air pollution. Various studies for a large-scale commercialization of UAM are being actively conducted. To that end, the UAM Traffic Management system aims at securing a safety and an efficiency of UAM operations. In this study, a risk assessment model is proposed to evaluate the risk of collision between a vehicle and surrounding obstacles. The proposed model is conceived from the past studies for determining a proper separation distance between parallel runways for their independent operations. The model calculates the risk that the surveillance system fails to meet a target level of safety for a given buffer zone size between a designed route and surrounding obstacles. The model is applied to one of the routes proposed in K-UAM roadmap to evaluate its performances.

A Study on the Improvement of Aviation Safety in Jeju Southern Air Corridor(AKARA-FUKUE Corridor) (제주남단 항공회랑(AKARA-FUKUE Corridor)의 항공안전 개선에 관한 연구)

  • Ahn, Hee-Bok;Hwang, Ho-Won
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.29 no.2
    • /
    • pp.55-66
    • /
    • 2021
  • ICAO recommended that airspace monitoring and periodic safety assessments in each Contracting State ensure the stability of the airspace, since reducing the aircraft lateral and vertical separation intervals would rather increase the risk of collision. The target level of safety of the AKARA-FUKUE Corridor at the southern end of Jeju was 247×10-9. In simple comparison, this means that the risk of an aircraft collision in this area (international safety standards, 5.0×10-9) is about 50 times higher. The scope of this study is to organize the concept of terms, analyze the air traffic volume, the current status of navigational safety facility usage fees, and investigations of an aircraft collision risk in Jeju southern air corridor. Analyzing government policies and overseas evaluations, revising some of the existing contents, presenting some of the additional contents of new routes, and changing the instrument procedure for Korean-Chinese routes, change of arrive/departure route between Incheon Airport and Shanghai Airport, reduce the risk of aircraft collisions. We hope to restore airspace sovereignty, contribute to policies for the government to take the lead in solving this problem, and expect stability and operational efficiency in air traffic.

Improving the Distribution of Temperature by a Double Air Duct in the Air-Heated Plastic Greenhouse (시설내 온도분포 균일화를 위한 온풍난방기용 2중 덕트개발)

  • 김태영;김기덕;조일환;남은영;남윤일;우영회;문보흠
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.162-166
    • /
    • 2004
  • Air temperature variation along the length of the air duct in an air-heated plastic greenhouse was large, 13 ~ 15$^{\circ}C$ between the front and the rear side of a greenhouse. To reduce this temperature variation, a new PE-film air duct having a small duct inside a large duct (double duct) was developed. This double duct was consisted of an inner duct with air outlets at a 0.15 m interval and an outer duct with air outlets at a 2.5 m interval. Diameters of the air outlet holes were 7, 15, and 35 cm from the front to the end of the inner duct film, while identical 10 cm holes were used on the outer duct film. As a result, air temperature was $46^{\circ}C$ at the beginning side and $47^{\circ}C$ at the ending side, while the conventional single duct had $53^{\circ}C$ at the beginning point and $38^{\circ}C$ at the ending point with a variation of $15^{\circ}C$. Height of a cucumber crop grown in a greenhouse with the new double air duct system was 65.5 cm, 14% increase as compared to that in a greenhouse with a conventional air duct system. Total fruit yield per l0a greenhouse in a greenhouse with the new double air duct system was 4,616 kg, which was 17% greater than that in a greenhouse with a conventional air duct system. Amount of heating oil consumption during March 3 to April 24, 2002 was 3,233 L per l0a greenhouse with the new double air duct system, which was 13% less than that with a conventional air duct system.