A Study on Air-distribution method for the Thermal Environmental Control in the Data Center (데이터센터의 합리적인 환경제어를 위한 공기분배 시스템에 대한 연구)

  • Cho, Jin-Kyun;Cha, Ji-Hyoung;Hong, Min-Ho;Yeon, Chang-Kun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.487-492
    • /
    • 2008
  • The cooling of data centers has emerged as a significant challenge as the density of IT server increases. Server installations, along with the shrinking physical size of servers and storage systems, has resulted in high power density and high heat density. The introduction of high density enclosures into a data center creates the potential for "hot spots" within the room that the cooling system may not be able to address, since traditional designs assume relatively uniform cooling patterns within a data center. The cooling system for data center consists of a CRAC or CRAH unit and the associated air distribution system. It is the configuration of the distribution system that primarily distinguishes the different types of data center cooling systems, this is the main subject of this paper.

  • PDF

Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor (인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

Heating Performance of a Ground Source Multi-Heat Pump for a Greenhouse (지열원 멀티 열펌프 시스템의 시설원예 적용 난방성능 특성 실증 연구)

  • Kang, Shin-Hyung;Choi, Jong-Min;Moon, Je-Myung;Kwon, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.337-344
    • /
    • 2010
  • Good plant-growth conditions can be achieved by means of using greenhouses. One of the main issues in greenhouse cultivation is energy savings through the development of high efficient heating and cooling system. GSHPs are one of the recommended systems to cope with this pending need. The aim of this study is to investigate the heating performance of ground source multi-heat pump system installed in a greenhouse under part load conditions. Daily average heating COP of the heat pump unit was very high by at least 7.4, because of relatively large condenser, evaporator, and mass flow rate through ground loop heat exchanger. However, the system COP, overall heating coefficient of the performance of the system with heat pump unit and GLHX, decreased drastically due to relatively large power consumption of circulating pump under part load condition. It is suggested that the technology to enhance the performance of the ground source multi-heat pump system for a greenhouse under part load conditions should be developed.

Suggestion of the Worth Evaluation of Cool Air and the Allocation Methodology of Cooling Cost (냉기의 가치평가 및 냉방비 배분방법론 제안)

  • Kim, Deok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.201-208
    • /
    • 2009
  • Our government will make a plan regulating the cooling limit temperature of the summer season to 26 degree and the heating limit temperature of the winter season to 20 degree for energy saving. Where, the key point of this politic pursuit can be the charge system on heating and cooling cost. We have suggested new cost allocation methodology as a worth evaluation method in the precedent study, and preformed the worth evaluation and cost allocation on four kind of warm air produced from a heating system as an example. In this study, we applied the suggested method to four kind of cool air, and preformed the worth evaluation and cost allocation on each cool air. As a result, similarly to the precedent study, the more energy a customer saved, the more cooling unit cost decreased, and the more energy a customer consumed, the more cooling unit cost increased. From this analysis, we hope that the suggested methodology can offer a theoretical basis to the energy charge policy of government, and induce the spontaneous energy saving of consumers.

A Study on the Optimization of Discharge Grille of Outdoor Unit of Air Conditioner (에어컨 실외기 토출그릴 형상 최적화)

  • Choi, Seok-Ho;Oh, Sai-Kee;Kim, Hyun-Jong;Jin, Geun-Ho;Oh, Si-Young;Kim, Byung-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.726-732
    • /
    • 2011
  • The aerodynamic and aeroacoustic performance of discharge grille of outdoor unit of air-conditioner was investigated in this study. Discharge grille is one of outdoor unit's important parts to affect the flow rate and Overall Sound Pressure Level(OSPL). New type of discharge grille was suggested based on the results of numerical simulation. To simulate the flow pattern near the propeller fan, commercial flow solver FLUENT was used. Sliding mesh method was used for rotating propeller fan and initial condition for unsteady model was calculated by Multiple Reference Frame(MRF) method. To minimize the interaction noise between fan blade wake and discharge grille, new discharge grille has radial rib which is aligned with trailing edge of fan blade. And inclined radial rib was adopted for reducing flow rate drop in discharge grille. The optimization of inclined angle of radial grille was performed experimentally.

Refrigerant Amount Detection Technology for System Air-Conditioner Using Design of Experiment (실험계획법을 이용한 시스템에어컨의 냉매량검지 기술개발)

  • Lee, Soo-Young;Takeichi, Hisashi;Tae, Sang-Jin;Yoon, Baek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.26-32
    • /
    • 2010
  • This paper is suggesting a new technology for refrigerant amount detection of a system air-conditioner installed under various installation conditions. System air-conditioner was introduced to domestic market first in 2000. It consists of one or a series of outdoor units and a number of indoor units connected with single pipe line to the outdoor unit. The system can vary the capacity from 2.0 kW to 186 kW. For the system Installed under long and high-elevated condition, about 100 kg of refrigerant is charged in the whole system. In this paper, the new technology RAD (Refrigerant Amount Detection) with edge technology of refrigerant cycle control and measurement of a system air conditioner was developed and investigated for its application for the various installation conditions.

A Case study on the Improvement of Air Conditioning System for Thermal Comfort and Energy Conservation in a Middle-Sized Auditorium (사례연구를 통한 중규모 공연장의 공조시스템 개선 방안에 관한 연구)

  • Na, S.Y.;Rhee, E.K.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.85-96
    • /
    • 2002
  • Recently the number of auditoriums such as theaters, assembly halls, and concert halls is increasing in Korea. Auditoriums have generally large space volume, have a high density of occupancy per unit floor area, compared to other buildings. Since they have relatively high ceilings, some heat may stratify above the occupied zone. The under floor air conditioning system, which is set under seats, is frequently selected in an auditorium, because typical air conditioning system where air is supplied from ceilings often causes drafts and unequal temperature distribution. Therefore, this study aims to suggest basic data for air conditioning system design of a middle-sized auditorium. Features and problems of air conditioning system of an auditorium which has about 500 seats are investigated as a case study. In addition, indoor thermal comfort and cooling energy consumption are analyzed with a CFD program and an energy analysis program.

Proposal of Unit Building Method for Calculating Unit Heating Load of Apartment Houses (공동주택 단위난방부하 계산을 위한 단위동법 제안)

  • Yoo Ho-Seon;Chung Joo-Hyuk;Moon Jung -Hwan;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.68-76
    • /
    • 2007
  • As an alternative approach to evaluate the unit heating load for apartment houses, we newly developed and proposed unit building method. The new method, which calculates the heating load of an apartment building as a whole, conceptually corresponds to integral analysis of building heat loss, while the existing unit apartment method to differential analysis. Four typical building models of Korean-style apartment house and two dynamic load calculation programs were selected to validate the present method under realistically imposed conditions. Eight sets of unit heating load calculated respectively by unit building and unit apartment methods showed excellent agreements regardless of building model and simulation program. It is expected that the unit building method can take the place of the unit apartment method due to fewer modeling assumptions as well as less computational efforts. Additional calculations to investigate the effects of various parameters on unit heating load yield good consistencies with known facts, and re-confirm the validity.

A Suggestion for the Worth Evaluation of Warm Air and the Allocation Methodology of Heating Cost (온기의 가치평가 및 난방비 배분방법론 제안)

  • Kim, Deok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.654-661
    • /
    • 2008
  • Our government will make a plan regulating the cooling limit temperature of the summer season to 26 degree and the heating limit temperature of the winter season to 20 degree for energy saving. Where, the key point of this politic pursuit can be the charge system on heating and cooling cost. Currently, the heating and cooling cost are charged as much as the volume or heat flow rate regardless of the high and low room temperature. However, we have suggested new cost estimating methodology as a worth method in the precedent study, and preformed the worth evaluation and cost allocation of electricity and heat on various cogenerations. In this study, we applied the suggested worth method to four kind of warm air, and preformed the worth evaluation and cost allocation of each warm air. As a result, the more energy a customer saved, the more heating unit cost decreased, and the more energy a customer consumed, the more heating unit cost increased. From this analysis, we hope that the suggested worth methodology can offer a theoretical basis to the politic pursuit of government, and induce the spontaneous energy saving of consumers.

Experimental Study of the Refrigerant Induced Noise for Air Conditioner Using Flow Pattern Map (유동 양식 선도를 이용한 에어컨 실내기의 냉매 소음 저감 분석)

  • Han, Hyung-Suk;Mo, Jin-Yong;Jeong, Weui-Bong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.957-963
    • /
    • 2008
  • The refrigerant-induced noise of the air conditioner is one of the irregular noises which occurs at the indoor unit. Because the air-conditioner makers are always trying to reduce the sound pressure level radiated from indoor unit, reducing the refrigerant-induced noise at low cooling mode is very important problem. But it is very difficult to estimate whether the refrigerant-induced noise occurs or not before it becomes problem. In this paper, a method to predict the refrigerant-induced noise is suggested using flow pattern map. It is estimated that the irregular noise from the refrigerant comes from the slug flow in a pipe.

  • PDF