• 제목/요약/키워드: Air Conditioning Duct

검색결과 189건 처리시간 0.026초

LDV에 의한 곡관 후류에 연결된 직관에서 난류맥동유동의 유동특성 (Flow Characteristics of a Turbulent Pulsating Flow in a Straight Duct Connected to a Curved Duct by using an LDV)

  • 손현철;이행남;박길문
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.177-186
    • /
    • 2003
  • In the present study, the flow characteristics of developing turbulent flows are investigated at the exit region of a square cross-sectional 180" curved duct with dimensions of 40mm$\times$40mm$\times$4000mm (height $\times$ width $\times$length). Smoke particles produced from mosquito coils were used as seed particles for the LDV measurement. Experiments were carried out to measure axial velocity profiles, shear stress distributions and entrance lengths by using an LDV system and Rotating Machinery Resolver RMR with PHASE software. Experimental results clearly show that the time-averaged Reynolds number does not affect oscillatory flow characteristics because the turbulent components tend to balance the oscillatory components in the fully developed flow region. Also, the velocity profiles are in good agreement with 1/7power law such as the results of steady turbulent flows. The turbulent intensity linearly increases along the walls and is slightly higher, especially in the period of deceleration. On the other hand, the LDV measurements show that shear stress values in slightly higher in the period of deceleration due to the flow characteristics in the exit region. The entrance length where flows become stable appears at the point that is 40 times the length of hydraulic diameter.eter.

단락요철이 회전덕트 내 압력강하에 미치는 영향 (Effects of Discrete Ribs on Pressure Drop in a Rotating Two-Pass Duct)

  • 김경민;이동현;조형희
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.443-450
    • /
    • 2006
  • The present study has been conducted to investigate the effects of rotation on heat/mass transfer and pressure drop characteristics in a two-pass square duct with and without discrete ribs. For stationary cases, the heat/mass transfer on the surfaces with and without discrete ribs is almost the same or reduced. For rotating cases, the gap flow affects differently the heat/mass transfer on leading and trailing surfaces with discrete ribs. On the leading surface of the first pass, the heat/mass transfer is slightly enhanced due to generating strong gap flow. On the trailing surface of the first pass, however, the heat/mass transfer is much decreased because the gap flow disturbs impingement of main flow. The phenomenon, that is, the heat/mass transfer discrepancy between the leading and trailing surfaces is distinctly presented with the increment of rotation number. The friction losses on each surface with discrete ribs are reduced because the blockage ratio decreases for both non-rotating and rotating cases. Therefore, high thermal performance appears in a duct with discrete ribs.

LDV에 의한 정사각 단면 180° 곡덕트에서 난류진동유동의 유동특성 (Characteristics of Developing Turbulent Oscillatory Flows in a 180° Curved Duct with a Square Sectional by using a LDV)

  • 윤석주;이행남;손현철
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.344-353
    • /
    • 2015
  • In the present study the characteristics of turbulent oscillatory flows in a square-sectional $180^{\circ}$curved duct were investigated experimentally. A series of experiments for air flow were conducted to measure axial velocity profiles, secondary flow velocity profiles and pressure distributions. The measurements were made by a Laser Doppler Velocimeter (LDV) system with a data acquisition and processing system which includes Rotating Machinery Resolve (RMR) and PHASE software. The results from the experiment are summarized as follows. (1) The maximum velocity moved toward the outer wall from the region of a bend angle of $30^{\circ}$. The velocity distribution had a positive value extended over the total phase in the region of a bend angle of $150^{\circ}$. (2) Secondary flows were generally proportional to the velocity of the main flow. The intensity of the secondary flow was about 25% as much as that in the axial direction. (3) Pressure distributions were effects of the oscillatory Dean number and respective region.

천정형 정풍량 시스템에어컨의 적용높이에 따른 실내온열환경 특성 (Comparison of the PMV and ADPI according to Adapted Height of Ceiling-type System Air-conditioner in Large space)

  • 성상철;김혁순;진심원;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.590-595
    • /
    • 2009
  • PMV and ADPI were numerically investigated in a large space of various ceiling height with air-conditioning systems of two type. The numerical results showed that it is small that the growth of cooling load according to ceiling height rise in a large space without windows. In case of system air-conditioner of duct type embedded in the ceiling, the air mixing effect in indoor is superior to a case installed 4way cassette type in it. For controling thermal comfort at indoor, a system air-conditioner of duct type embedded in the ceiling is little influenced according to ceiling height rise in a large space considered.

  • PDF

열교환기 내부 유로 종횡비 변화에 따른 국소 열/물질전달 특성 고찰 (Effects of Aspect Ratio on Local Heat/Mass Transfer in Wavy Duct)

  • 장인혁;황상동;조형희
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.569-580
    • /
    • 2005
  • The present study investigates the convective heat/mass transfer characteristics in wavy ducts of a primary surface heat exchanger. The effects of duct aspect ratio and flow velocity on the heat/mass transfer are investigated. Local heat/mass transfer coefficients on the corrugated duct sidewall are determined using a naphthalene sublimation technique. The aspect ratios of the wavy duct are 7.3, 4.7 and 1.8 with the corrugation angle of $145\Omega$. The Reynolds numbers, based on the duct hydraulic diameter, vary from 300 to 3,000. The results show that at the low Re(Re $\leq$ 1000) the secondary vortices called Taylor-Gortler vortices perpendicular to the main flow direction are generated due to effect of duct curvature. By these secondary vortices, non-uniform heat/mass transfer coefficients distributions appear. As the aspect ratio decreases, the number of cells formed by secondary vortices are reduced and secondary vortices and comer vortices mix due to decreased aspect ratio at Re$\leq$1000. At Re >1000, the effects of corner vortices become stronger. The average Sh for the aspect ratio of 7.3 and 4.7 are almost same. But at the small aspect ratio of 1.8, the average Sh decreases due to decreased aspect ratio. More pumping power (pressure loss) is required for the larger aspect ratio due to the higher flow instability.

환기용 덕트내의 전달소음 특성에 관한 연구 (A Study on the Transmitted Noise Characteristics through the Ventilating Duct)

  • 최한림;김경환;최호선;오세기;정백영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.376-380
    • /
    • 2009
  • The transmission noise characteristics through the ventilating duct was conducted numerically using SYSNOISE. A ventilating system is usually composed of mufflers for preventing noise transmission from the ventilator into indoors through the ducts and distributors for transferring air to or from each room. The transmitted noise characteristics of distributors which have different branch angles and of mufflers having different shapes were analyzed numerically. New duct element combining a muffler and a T-shaped distributor was developed for better noise reduction in this paper. New element's performance was shown numerically.

  • PDF

단면의 폭이 감소하는 180^{\circ}$ 곡덕트 내 난류유동의 수치해석적 연구 (Numerical Study on the Turbulent Flow in the 180^{\circ}$ Bends Decreasing Cross-sectional Aspect Ratio)

  • 김원갑;최영돈
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1056-1062
    • /
    • 2002
  • This paper reports the characteristics of the three dimensional turbulent flow in the 180 degree bends with decreasing cross-sectional area by numerical method. Calculated pressure and velocity, Reynolds stress distributions are compared to the experimental data. Turbulence model employed are low Reynolds number k-epsilon model and algebraic stress model. The results show that the main vortex generated from the inlet part of the bend maintained to outlet of the bend because of the contraction of cross-sectional area. The rate of increase of turbulent kinetic energy through the bend are lower than that of mean flow. Secondary flow strength of the flow is lower about 60% than that of square duct flow.

짧은 못형핀의 형상 변화에 따른 열전달 및 마찰손실 특성 (Heat transfer and friction loss characteristics of shaped short pin-fin arrays)

  • 조형희
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.259-267
    • /
    • 1997
  • Average heat transfer coefficients and friction coefficients have been measured from staggered short pin-fin arrays to investigate the effect of fin shapes. Flow entering into the test section is a fully developed duct flow and the Reynolds number ranges from 5,000 to 25,000 based on fin diameter and average approaching velocity. The fin has three different shapes; uniform-diameter circular fin, two stepped-diameter circular fins. Average heat transfer rates change slightly with the fin shapes. However, friction loss(pressure loss) for the stepped-diameter fins is significantly less than that for the uniform-diameter fin. This results indicate that the stepped-diameter fin arrays in duct flow enhance heat transfer rates largely based on unit pumping power.

  • PDF

단면의 폭이 증가하는 $180^\circ$ 곡덕트 내 난류유동의 수치해석적 연구 (Numerical Study on the Turbulent Flow in the $180^\circ$ Bends increasing Cross-sectional Aspect Ratio)

  • 김원갑;김철수;최영돈
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.804-810
    • /
    • 2004
  • This paper reports the characteristics of the three dimensional turbulent flow by numerical method in the 180 degree bends with increasing cross-sectional area. Calculated pressure and velocity, Reynolds stress distributions are compared to the experimental data. Turbulence model employed are low Reynolds number $textsc{k}$-$\varepsilon$ model and algebraic stress model(ASM). The results show that the main vortex generated from the inlet part of the bend maintained to outlet of the bend and vortices are continually developed at the inner wall region. The distribution of turbulent kinetic energy along the bend are increase up to 120$^{\circ}$ because of increment of cross-sectional area. Secondary flow strength of the flow is lower about 60% than that of square duct flow.

원형 덕트용 VAV 댐퍼의 성능 비교 (Comparison of the Performance of the VAV Dampers for the Circular Duct)

  • 권영필
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.699-703
    • /
    • 2012
  • The performance of the typical VAV dampers; blade type, venturi type and blade-orifice type, for the circular duct, is obtained by measuring the volume flow rate as a function of the opening degree. The performance features are discussed by comparing the volume flow rate of each damper. It is shown that the blade-orifice type damper, recently developed, is excellent in its linearity of the performance and that it is worse than the blade type but much better than the venturi type in its flow resistance.