• 제목/요약/키워드: Air Conditioning Duct

검색결과 189건 처리시간 0.029초

축소-확대 유로에 적용한 횡류형 수직 풍력발전시스템의 개발 (Development of a Cross-flow Type Vertical Wind Power Generation System for Electric Energy Generation Using Convergent-Divergent Duct)

  • 정상훈;정광섭;김철호
    • 설비공학논문집
    • /
    • 제23권8호
    • /
    • pp.543-548
    • /
    • 2011
  • New concept of wind energy conversion system is proposed to increase the energy density at a given working space. The quality of wind for wind power generation is depend on its direction and speed. However, the quality is not good on land because wind direction is changeable all the time and the speed as well. The most popularly operated wind turbine system is an axial-flow free turbine. But its conversion efficiency is less than 30% and even less than 20% considering the operating time. In this research, a cross-flow type wind turbine system is proposed with a convergent-divergent duct system to accelerate the low speed wind at the inlet of the wind turbine. Inlet guide vane is also introduced to the wind turbine system to have continuous power generation under the change of wind direction. In here, the availability of wind energy generation is evaluated with the change of the size of the inlet guide vane and the optimum geometry of the turbine impeller blade was found for the innovative wind power generation system.

Tracepro를 활용한 이중 블라인드 광파이프 채광 시스템의 블라인드 설계 및 시스템 효율 평가 (Tracepro Simulation Design and Evaluation for the Double Blind Light Pipe Daylighting System)

  • 강은철;이의준;유성연
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.515-520
    • /
    • 2012
  • A daylighting system includes three parts; light collector, light transformer and light distributor. A DBLP(Double blind light pipe) daylighting system consists of a double blind light collector, a mirror duct type light transformer and a prism film light pipe distributor. The double blinds for a light collection are used to track the sun's altitude and azimuth movements throughout the day. Behind both sets of blinds is the light transformer, which is based on a rectangular cone shaped light duct. The light transformer was designed to efficiently deliver the light into the light pipe within a 30 degree radial spread for the efficient light into the distributor. In this study, DBLP system efficiency was simulated, evaluated and optimized by Tracepro as a popular ray trace light design simulation program. The results indicated that DBLP system efficiency evaluated a maximum 22.4% in case of Spring/Fall season solar noon time. While the overall average system efficiency in the morning and afternoon is evaluated about 10%.

덕트 내 오염물질 퇴적 방지를 위한 벽면유동 제어에 관한 해석적 연구 (Numerical Investigation on Wall Flow Control for Preventing Contaminants Deposition inside a Duct)

  • 이방욱;이지근
    • 설비공학논문집
    • /
    • 제25권5호
    • /
    • pp.261-268
    • /
    • 2013
  • Technologies for preventing contaminants deposition are a key issue in a modern duct system. When particulate matters deposit inside the exhaust pipes, which are widely used in the Urea-SCR system to reduce $NO_x$ emission from heavy duty diesel engines, many problems arise associated with increased flow resistance and corrosion. Therefore, the development of the urea deposition avoidance technologies is being treated as an important issue of the Urea-SCR system. An analytical study was carried out to investigate the effects of the wall flow around the mixer with the variation of the mixer housing surrounding and supporting the mixer, which is designed to increase the wall flow and then to reduce droplet deposition. The housing angles and the position of the mixer were changed:angles of $0^{\circ}$, $1^{\circ}$, $2^{\circ}$, and $3^{\circ}$, and mixer positions of 0 L, 0.5 L, and 1 L. The axial velocity distributions, maximum velocity, the half-width, and momentum distribution of the wall flow were investigated to examine the effect of the mixer-housing assembly geometry.

CFD를 이용한 승용차 에어컨 덕트의 최적설계 (Optimum Design of an Automotive A/C Duct using by CFD)

  • 김태훈;정수진
    • 한국분무공학회지
    • /
    • 제1권3호
    • /
    • pp.37-50
    • /
    • 1996
  • Computational fluid dynamics was used to optimize an A/C duct. Three dimensional flow analysis in an automotive A/C duct was performed computationally using various turbulence models and compared numerical predictions such as outlet flow split, surface pressure distribution along the duct to experimental data. Additionally, we studied the effect of location variation of 2nd branch on exit flow ratio and could find optimal location of 2nd branch. The design of an A/C duct was modeled and calculated to enhance the airflow distribution in each outlet using the STAR-CD computational fluid dynamics software. In results, modified $k-\varepsilon$ turbulence model allows a successful prediction of static pressure distribution particulary at around strong curvature but little improvement flow split. In the future, adoption of CFD to design an A/C duct with modified $k-\varepsilon$ model will bring benefits of producing more accurate prediction, and also give designers more detail information much more than now.

  • PDF

Heat Transfer and Friction Behaviour in a Channel with an Inclined Perforated Baffle

  • Krishna Putra, Ary Bachtiar;Ahn, Soo-Whan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.70-76
    • /
    • 2008
  • The effects of the inclined perforated baffles on the distributions of the local heat transfer coefficients and friction factors for air flows in a rectangular channel were determined for Reynolds numbers from 23,000 to 57,000. Four different types of the baffle are used. The inclined baffles have the width of 19.8cm, the square diamond type hole having one side length of 2.55cm, and the inclination angle of $5^{\circ}$, whereas the corresponding channel width-to-height ratio was 4.95. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle, and the heat transfer performance of baffle type II (3 hole baffle) has the best value.

CFD를 활용한 태양열 공기가열기 내 사각저항체 설치 조건에 따른 열전달 및 압력강하에 관한 연구 (Research on the Heat Transfer and Pressure Drop by Installation Conditions of Rectangular Obstacle in a Solar Air Heater Based on CFD)

  • 최휘웅;김영복;손창효;윤정인;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제39권1호
    • /
    • pp.77-89
    • /
    • 2019
  • The solar air heater has various performances according to an obstacle installed in the air duct. Many studies on thermal performance have been conducted. But many of these studies were using a kind of rib type obstacle attached at the bottom of absorbing plate, but they are so hard to be manufactured. In this study, characteristics of the heat transfer and pressure drop in the solar air heater with various horizontal rectangular obstacles was investigated by CFD (Computational Fluid Dynamics) analysis. As a result, the heat transfer performance was improved from 1.2 to 3.32 times depending on installation conditions of rectangular obstacle. The pressure drop, however, also increased with increment of heat transfer performance from 2.8 to 180 times only by changing installation conditions of rectangular obstacle. Thus, the performance factor presenting the thermal performance enhancement on the same pressure drop was also confirmed. As a result, the highest value of 0.828 as better performance factor was obtained at the lower height of rectangular obstacle and this value has started to decrease with increment of heat transfer performance. In the end, it could be confirmed that the pressure drop was carried higher than the quantity of improvement of the heat transfer performance when the heat transfer performance was increased by change of installation conditions of rectangular obstacle. Both heat transfer enhancement and pressure drop to be required for system need to be considered before the rectangular obstacles are applied to the solar air heater.

승용차의 제상 및 성에 제거 성능 평가를 위한 수치해석적 연구 (Numerical Study on the Performance Assessment for Defrost and De-Icing Modes)

  • 김윤기;양장식;김경천;지호성
    • 대한기계학회논문집B
    • /
    • 제35권2호
    • /
    • pp.161-168
    • /
    • 2011
  • HVAC(Heating, Ventilating, Air Conditioning) 시스템은 승객실 내부의 열환경을 제어하여 쾌적성을 향상시키거나 전면 유리창에 생성된 성에를 제거하여 운전자의 가시영역을 확보하는 등 차량의 성능과 관련된 매우 중요한 기능을 담당한다. 본 연구에서는 CFX 를 사용하여 HVAC 시스템의 기능 중 제상 덕트의 성능과 관련된 수치해석적 연구를 수행하였다. 제상덕트의 해석결과, 출구에서의 유량배분특성 및 유동구조는 일반적인 설계주안점에 부합된 양호한 결과를 얻었다. 외부온도 $-18^{\circ}C$ 하에서 물의 잠열인 $3.37{\times}10^5$[J/kg]을 고려한 상변화 과정을 수치적으로 모사하기 위하여 열용량법을 사용하였고, 시간에 따른 제상패턴 해석을 위해 얼음과 유리의 고체도메인에 대한 추가적인 격자 생성 작업이 필요하였다. 유동해석 결과, 전면유리 근처의 유동구조, 유적선, 온도장 해석결과는 본 연구에서 수행한 제상덕트 모델이 우수한 성능으로 제상기능을 수행할 수 있음을 보였으며, 수치해석적 결과는 실험적 결과와 비교하여 제상패턴이 잘 일치함을 확인하였다. 또한 전면유리 상의 4 개의 지점에서 얻어진 온도, 물분율, 엔탈피의 시간에 따른 변화를 통해 상변화 과정을 정량적으로 파악하였다.

다양한 덕트유동해석에 사용된 AIRVIEW의 정확성 비교에 관한 연구 (Study on the Accuracy Comparison of AIRVIEW used for various duct flows)

  • 권용일;염동석;한화택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.383-388
    • /
    • 2008
  • We are now developing a CFD program, AIRVIEW, with several numerical models and the SIMPLER solving method for constructing flow field and thermal comfort. This study is carried out for evaluating an accuracy of AIRVIEW. Comparisons of accuracy are carried out using Phoenics Version 3.4. In this study, we compare the turbulent kinetic energy distribution and local turbulent Re number obtained with Phoenics with those results simulated by AIRVIEW for three kinds of duct. It is observed from comparison of results that the turbulent kinetic energy values are significant due to the large velocity gradients in the region of flow. Numerical results for turbulent kinetic energy distribution and local turbulent Re number are that a good degree of agreement is found.

  • PDF

90$^{\circ}$분기덕트에서 분기부의 내 .외벽의 속도분포 (The Velocity distributions of Dividing Region to Internal Wall and External Wall in 90$^{\circ}$ Dividing Duct)

  • 이행남;박길문;손현철;이덕구;이종구;김대욱
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.35-39
    • /
    • 2002
  • The flow characteristics in a bifurcated duct are investigated experimentally. Physical properties such as mean velocity vectors, mean vorticity and total pressure distributions are obtained for three different Reynolds numbers(578, 620, 688) using PIV measurements and CFD analysis. Also, dividing duct $90^{\circ}$ were selected for study. The results of this study would be useful to the engineer in designing the flow systems for heating, ventilation, air conditioning and wastewater purification plants.

  • PDF

노후하수관 워터젯분사장치의 분사조건에 따른 열전달특성에 관한 연구 (A Study on the Heat Transfer Characteristics of Water-Jet-Impingement)

  • 노홍구;임경빈;노종호;이영기;이성철;고준빈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1190-1194
    • /
    • 2008
  • The study aims to analyzed and identify the heat transfer characteristics of water-jet-impingement with use of 3-D numerical-analysis in order to design the old water duct. The temperature comparison processes were done with various duct flows. In addition, the optimal conditions of water-jet-impingement were proposed as jet-pressure, the temperature on the beat plane, and so on.

  • PDF