• 제목/요약/키워드: Air Conditioner

검색결과 775건 처리시간 0.032초

Context Aware Services using Multi-Environmental Sensors and Its application for Ubiquitous Home Networks

  • Quang, Bui Dang;Torregoza, John Paul M.;Hwang, Won-Joo
    • 한국멀티미디어학회논문지
    • /
    • 제10권6호
    • /
    • pp.786-798
    • /
    • 2007
  • As we go about our daily lives, people often collect surrounding information and adapt to the situation. Computer development trends show that one wants computers to work like human beings, i.e. computers can sense its context and adapt corresponding to context changes. To implement this expectation, a context aware service layer is needed. In this layer, sensors capture its environment and send this information to the service center. Considering received information as its context, the service center seeks the suitable operation according to the context. Tills paper presents a context aware service which is applied in controlling air-conditioner. The air-conditioner includes sensors which are installed at some special positions in a room. Each of these sensors gathers comfort-influenced information like temperature, humidity and sends them to air-conditioner. The air-conditioner adapts its operation to the environment according to the sensed information. To control the air-conditioner effectively, we use a genetic algorithm which is suitable in adaptation issues. The simulation shows that the room condition can be maintained at a comfortable level by using context-aware services in the operation of the air-conditioning system.

  • PDF

화재 실험을 통한 에어컨 실내기의 화염확산에 관한 현상학적 연구 (A Phenomenological Study on the Flame Spread of Air Conditioner Indoor unit by Fire Tests)

  • 최승복;이승훈;최민기;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.89-96
    • /
    • 2013
  • 본 연구의 목적은 연소 실험을 통하여 에어컨 실내기의 화염확산에 관한 형상을 관찰하여 화재원인 및 발화지점을 확인하기 위함이다. 본 실험은 화염이 주변으로부터 에어컨 상단에 옮겨 붙는다는 것을 가정하여 실내기 상단을 n-햅탄을 적신 천으로 착화시켰으며, 동일한 조건으로 2회의 반복실험을 하였다. 착화 후 559 s와 734 s 사이에 실내기와 연결된 냉매관이 파열되면서 내부에 충입되어 있던 냉매와 함께 윤활유가 커다란 폭음을 내며 고온 고압의 화염이 급격히 분출되었으며 연소 잔류물을 확인한 결과, 증발기 일부와 모터, 금속함 등을 제외한 대부분은 소실되었다. 에어컨 자체에서 발화되었을 경우와 외부 화염에 의해 소훼되었을 경우 배선의 합선흔적 위치는 유사하였다. 따라서 연소 잔류물의 형상만으로 발화원인과 지점을 특정 짖는 것은 불확실하다는 것을 확인하였다.

급기환기량에 따른 공조기의 설정온도 도달특성 분석 연구 (A Study on the Reaching Time of Setting Temperature with Ventilation Air)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.50-57
    • /
    • 2006
  • This study describes to analyze the cooling load characteristics for a room air conditioner as a function of supply ventilation air when an air conditioner is running An experimental apparatus consists of a test room, a room air conditioner, a humidifier, an electrical heater a supply fan and a controller The reaching time to the inside setting temperature of the room air conditioner with is evaluated theoretically and experimentally in a conditioned space cooling loads such as supply ventilation air, lighting, occupancy and infiltration. In the conditions of cooling loads for the supply ventilation air of 9.5 L/s(0.98 ACH). lights. one Person, and infiltration, the reaching time to the inside setting temperature ($27\;^{\circ}C$ dry-bulb) increases up to $35\%$ more than for no supply ventilation air condition. Theoretical modelling of the reaching time shows good agreement with experimental results.

Energyplus를 이용한 고효율 멀티에어컨디셔너의 에너지절감 효과 분석 (A Study on analyze of energy saving rate by retrofitting multi air-conditioner from conventional type to high efficient type using Energyplus)

  • 서정식;김욱중;우정태;최연성;전종욱
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.165.2-165.2
    • /
    • 2010
  • The objective of this study is to analyze the energy saving rate by retrofitting multi air conditioner from conventional type to high efficient type using Energyplus 4.0 which was developed for simulating a building energy by D.O.E. Generally, Multi air conditioner system was installed for both the cooling and the heating in a building. However, it was difficult to estimate the energy saving rate in the case of retrofitting multi air conditioner from conventional type to high efficient type. In the present study, annual energy consumptions of them were evaluated for same building and climate condition.

  • PDF

에어컨 실외기 받침대의 구조진동 특성 (Structural Vibration Characteristics for an Outdoor Units Support of an Air-conditioner)

  • 류봉조;송선호;임채욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.215-217
    • /
    • 2008
  • This paper deals with the structural vibration characteristics for an outdoor units support of an air-conditioner. Even though main noise sources are compressor noise and fluid noise which is caused by the fan, the structural modification of the outdoor units support may affect vibration and noise. In this paper, damping ratios for two kinds of an outdoor units support of an air-conditioner are measured through the modal testing. In order to reduce the structural borne noise due to an outdoor units support of an air-conditioner, four kinds of rubber materials are selected and tested.

  • PDF

실험적 방법을 통한 에어컨 실내기의 소음원 검출에 관한 연구 (A Study on Noise Identification of Indoor Air-conditioner Using Experimental Methods)

  • 이성진;오재응;이정윤;강태호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.87-87
    • /
    • 2004
  • An air-conditioner has various noise sources such as a fan noise, a motor noise, and a vibration induced noise. To reduce these noise effectively, noise sources must be identified. Especially in this paper, the structure borne sound radiated from the motor bracket of the indoor air-conditioner is considered. To do this, the operational deflection shape, which is used for understanding of the behavior of the motor bracket at a particular frequency, is obtained and compared with the sound intensity, which is used for the noise identification. Through this study, the noise sources of indoor air-conditioner are defined and the effective noise reduction method is proposed.

  • PDF

상용차를 위한 무시동 에어컨 압축기용 공진형 DC/DC 컨버터 개발 (Development of the Anti-Start Air Conditioner Compressor Resonant DC/DC Converter for Commercial Vehicle)

  • 한근우;김성곤;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.557-563
    • /
    • 2014
  • This study deals with a resonant converter of an anti-start air conditioner compressor for commercial vehicles. The anti-start air conditioner compressor must generally have a high current, high efficiency, a low volume, and a low weight. To reduce the switching losses and voltage and current stresses of the device, the anti-start air conditioner compressor applies the full-bridge L-C resonant converter topology. Hardware parameters are designed to have a wide voltage range, and the switching frequency range of the L-C resonant converter is determined. Simulation is implemented using PSIM and an experiment is performed to verify the proposed converter.

퍼지 알고리즘을 이용한 시스템 멀티 에어컨의 고장진단 알고리즘 개발 (Fuzzy Algorithm for FDD Technique Development of System Multi-Air Conditioner)

  • 최창식;태상진;김훈모;조금남;문제명;김종엽;권형진
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1220-1228
    • /
    • 2005
  • Fault detection and diagnostic (FDD) systems have the potential to reduce equipment downtime, service costs, and utility costs. In this study, model based algorithm and fuzzy algorithm were used to detect and diagnose various fault at System multi-air conditioner. various fault include the Refrigerant Low charging, Fouling of Indoor Heat Exchanger, Fouling of Outdoor Heat Exchanger A experimental verification was conducted in the 6HP System multi-air conditioner on an 8-floor building. Test results showed diagnosis result about 78 $\~$ 90$\%$ for given faults. This Study lays the foundation fur future work on develope the real-time fault detection and diagnosis system for the System multi-air conditioner.

에어컨 실내기에서 발생하는 충격 소음원의 위치 추정 (Source localization of impact noise on an indoor unit of air-conditioner)

  • 최영철;김양한;이종구;김구영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.324-329
    • /
    • 2003
  • An air-conditioner has various noise sources such as cooling fan noise, pumping noise, flow noise and impact noise. Among these, impact noise is the most unpleasant source. This is because the noise is produced in indoor unit of air-conditioner. To control the noise source effectively, first we must identify the noise sources. When we identify impact noise source, the measurement have to be carried out simultaneously. So we use beamforming method that requires less measurement points than intensity method and acoustic holography. The objective of this paper is to estimate the location of impact source. This objective can be achieved by using minimum variance cepstrum that is able to detect impulse embedded in noise. In this study, modified beamforming method based on cepstrum domain is proposed. Then this method applied to air-conditioner noise sources which produce impact noise.

  • PDF

트리즈를 이용한 에어컨디셔너 프레임구조 설계 (Design of Air-Conditioner Frame Structure Using TRIZ Based Contradiction Analysis)

  • 최하영;정의문;이종수
    • 한국생산제조학회지
    • /
    • 제21권6호
    • /
    • pp.961-967
    • /
    • 2012
  • The metal is frequently used in the air-conditioner frame, which must have the durability from the various external environments, but has difficulties in being manufactured for many complex shapes. On the other hand, the plastic, used as a material of injection molding, enables the realization of various shapes and the mass-production of complex ones and leads low production cost. As the air-conditioner frame becomes increasingly complex and detailed, the plastic material is highlighted as an alternative for the frame. But the product molded by plastic with a complex shape might have a noise problem. Therefore this study attempts to design the product through TRIZ in order to reduce the noise of the air-conditioner with the frame of plastic material.