• Title/Summary/Keyword: Air Compressor

Search Result 1,025, Processing Time 0.029 seconds

Experimental Reduction of the Noise Radiated by Rotary Compressor (로터리 컴프레서 방사소음의 실험적 저감)

  • 박상영;이상현;이수일;이장무
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.189-195
    • /
    • 1999
  • The noise radiated by the rotary compressor for a room air-conditioner was investigated experimentally. Noise characteristics and structural eigen modes of the compressor were identified through sound tests and modal tests each other. From these tests. we found that the accumulator has a big contribution to the noise radiation. So, various structural modifications for the accumulator were performed and these modification methods were found efficient to the noise reduction from verification tests.

  • PDF

Identification of Connection Stiffnesses of Bolted Structures Using a Substructural Sensitvitity Analysis (부분구조 기반 민감도 해석을 이용한 볼트겹합 구조물의 결합강성 추정)

  • 서세영;방극호;김찬묵;이두호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.7
    • /
    • pp.287-294
    • /
    • 2001
  • The identification of connection stiffnesses of bolted structures is presented using FRT-based substructural sensitivity analysis. The substructural design sensitivity formula is derived and plugged into the optimization module of MATLAB to identify connection stiffnesses of an air-conditioner compressor or passenger Car. The air-conditioner composed of a compressor and a bracket, is analysed by using the FRT-based substructural(FBS) method to obtain FTRs an FE model is generated for the bracket, and the impact hammer test is performed for the compressor, Obtained FRTs are combined to calculate the reaction force at the connection point and the system response. By minimizing the difference between a target FRT and calculated one the connection element properties of the air-conditioner syste are identified It is shown that the proposed identification method is effective for a real problem.

  • PDF

A study on the reduction of structure-borne noise from air condensing compressor (공기 압축기 고체음 저감에 대한 연구)

  • Jung, Sung-Jin;Choi, Su-Hyun;Jo, Hyun-Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.407-410
    • /
    • 2007
  • In the ship-building industry, reciprocating air condensing compressors are usually applied in the HVAC system because of their good performance, efficiency and the convenience. However, the inertia force and pressure fluctuation of the compressor may generate unexpected excessive noise and vibration in the near by cabins. This paper presents a theoretical background and appropriate countermeasures on the reduction of structure-borne noise from the compressors.

  • PDF

Development of Brushless DC Motor for 0.5[kW] Air Compressor of Electric Vehicle (전기자동차용 0.5[kW]급 공기압축기의 브러시리스 직류전동기 개발)

  • Han, Man-Seung;Hong, Song-Ryul;Jo, Ju-Hee;Lee, Sang-Hun;Park, Seong-Jun;Kim, Dae-Kyong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.71-78
    • /
    • 2012
  • Recently, it is increased to apply sensorless drive for BLDC (Brushless DC) motor to maximize operating efficiency and fuel efficiency to an electrical component of (H)EV. Especially, Electric vehicle component promotes a fuel efficiency enhancement by the carbon dioxide emissions regulation of a vehicle becoming the principal of the environmental pollution globally, the oil price hike that continued increasingly. We suggested the air compressor which applied BLDC motor for electric vehicle component and compared suggested BLDC motor with the conventional DC motor. The experimental results show that the driving efficiency was increased and was inproved compressive force by suggested BLDC motor.

Transient Performance of a System Heat Pump with the Variation of Compressor Speed and EEV Openings (시스템 히트펌프의 압축기 주파수 및 전자팽창밸브 개도 변화에 따른 과도성능 특성)

  • Lee, Sang-Hyeok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.3
    • /
    • pp.11-18
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system utilizing package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only easy distribution control allowing free combination of indoor units with different models and different capacities, but also wide applications to an intelligent air conditioning. In this study, the transient performance of a system heat pump was analysed with the variation of compressor speed and EEV openings. The superheat was selected as a control parameter of the system, because the variation of it was consistent with each indoor unit capacity.

Analysis of Operation Conditions of a Reheat Cycle Gas Turbine for a Combined Cycle Power Plant (복합화력 발전용 재열사이클 가스터빈의 운전상태 분석)

  • Yoon, Soo-Hyoung;Jeong, Dae-Hwan;Kim, Tong-Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.6 s.39
    • /
    • pp.35-44
    • /
    • 2006
  • Operation conditions of a reheat cycle gas turbine for a combined cycle power plant was analyzed. Based on measured performance parameters of the gas turbine, a performance analysis program predicted component characteristic parameters such as compressor air flow, compressor efficiency, efficiencies of both the high and low pressure turbines, and coolant flows. The predicted air flow and its variation with the inlet guide vane setting were sufficiently accurate. The compressor running characteristic in terms of the relations between air flow, pressure ratio and efficiency was presented. The variations of the efficiencies of both the high and low pressure turbines were also presented. Almost constant flow functions of both turbines were predicted. The current methodology and obtained data can be utilized for performance diagnosis.

A Study on the Balancing of Multi-Stage Reciprocating Air Compressor (다단 압축식 왕복동 공기압축기의 평형설계에 관한 연구)

  • 김형진;박용남;김의간
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.178-183
    • /
    • 2001
  • A multi-stage reciprocating air compressor has many pistons and conneting rods to one crank throw, while a general engine has one connecting rod. Those make its design hard to apply balance weight design method generally using in an engine design, This study introduces a modified balance weight design method in order to calculate the unbalanced inertia properly. Vibration tests on V/W type air compressor have been conducted to prove the usefulness of design program. It is confirmed that the proposed program is applicable to design of balance weight.

  • PDF

Selection of Sound Insulation Structure of Air-conditioner Compressor by Measurement of Sound Power (음향파워 측정에 의한 에어컨 컴프레서의 차음 구조 결정)

  • 이진교;김진섭;모진용;박득용;김봉준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.197-202
    • /
    • 2001
  • The compressor is one of major noise sources in air conditioner outdoor units, especially deteriorating the sound quality. Therefore, the sound insulation materials layered with sound absorption materials are applied around compressors. In this study, the performance of the sound insulators is examined by measuring the insertion losses in power base and the effects of sound absorption materials, method of application and the shape of the insulators are also investigated. The importance of minimizing the opening is revealed well.

  • PDF

An experimental study on the control properties of variable compressors for automotive air-conditioning system (자동차 에어컨용 가변압축기의 제어 특성에 관한 실험적 고찰)

  • Kim, Min Jun;Lee, Geon Ho;Park, Ik Seo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.691-696
    • /
    • 2004
  • Recently, it is required that the automotive air conditioning system must keep the cabin temperature comfortable in spite of engine speed, and Improve the fuel consumption during all the seasons. To satisfy these requirements, the variable displacement swash plate type compressor with control pressure valve is developed. In this study, the effects of two type valves, suction pressure control valve and differential pressure control valve, on the performance of swash plate type compressor has been investigated experimentally.

  • PDF

A Study on the Component Performance for Automotive Air Conditioner (자동차용 에어컨의 단품 성능에 관한 연구)

  • 이대웅;유성연
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.293-303
    • /
    • 2002
  • For successful design of component, performances of one-tank plate type evaporator, gas-liquid separation type condenser, swash plate type compressor and thermostatic expansion valve for automotive air conditioner are investigated experimentally. Heat transfer characteristics in the evaporator are examined by means of air temperature, relative humidity, air volume flow, outlet refrigerant pressure and superheat, and heat transfer characteristics in the condenser are examined by means of air temperature, air velocity and inlet refrigerant pressure. Pressure drops for both evaporator and condenser are measured arid empirical correlations are derived. Volumetric efficiencies and isentropic efficiencies for trio types of compressors with different capacity are measured and compared. Thermostatic expansion valve is tested to investigate the pressure variation according to temperature changes.