• 제목/요약/키워드: Air & gas

검색결과 5,018건 처리시간 0.028초

기체연료엔진의 제어시스템 설계를 위한 엔진 모델링 및 검증 (Engine Modeling and Validation for Control System Design of a Gaseous-fuel Engine)

  • 심한섭;선우명호
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.7-17
    • /
    • 2003
  • Highly accurate control of an air-fuel ratio is very important to reduce exhaust gas emissions of gaseous-fuel engines. In order to achieve this purpose, a precise engine model is required to estimate engine performance from the engine design process which is applied to the design of an engine controller. Engine dynamics are considered to develop a dynamic engine model of a gaseous-fuel engine. An effective air mass ratio is proposed to study variations of the engine dynamics according to the water vapor and the gaseous-fuel in the mixture. The dynamic engine model is validated with the LPG engine under steady and transient operating conditions. The experimental results in the LPG gaseous-fuel engine show that the estimation of the air flow and the air-fuel ratio based upon the effective air mass ratio is more accurate than that of a normal engine model.

Numerical Study on the Air-Cushion Glass Transportation Unit for LCD Panels

  • Im Ik-Tae;Jeon Hyun-Joo;Kim Kwang-Sun
    • 반도체디스플레이기술학회지
    • /
    • 제5권1호
    • /
    • pp.27-31
    • /
    • 2006
  • Non-contact transportation system using air cushion for the manufacturing of large-sized LCD panels was considered. Flow characteristics between air pad and glass plate was analyzed using computational fluid dynamics method to obtain optimized air pad configurations. Effects of the design variables such as hole arrays from which gas is injected, gas-feeding method into the gas supplying channels, and horizontal and vertical pitches of clusters of holes were studied. Optimized air pad unit gave evenly distributed pressure contour on the glass surface and well-suspended levitation height in the experiment.

  • PDF

소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안 (Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station)

  • 박제섭;한동훈
    • 한국산업보건학회지
    • /
    • 제30권4호
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

비전통가스 개발 확대에 따른 국내외 에너지믹스 동향 및 대기환경영향에 관한 연구 (A Study on the trend of Energy Mix and Air Environmental Impact Assessment)

  • 조한나;주현수;박주양
    • 환경영향평가
    • /
    • 제22권6호
    • /
    • pp.639-648
    • /
    • 2013
  • Unconventional natural gas resources are now estimated to be as large as conventional resources. Unconventional natural gas has became an increasingly important source of energy in the world since the start of this century. The factors that drive natural gas demand and supply point more and more to a future in which natural gas plays greater role in the global energy mix. The expansion of using natural gas will be expected in Korea. This research aims to analyze environmental impacts of expansion of unconventional natural gas. This research was carried out for comparative analysis between global energy mix and Korea energy mix, and developed a case that reflect the changed energy mix due to the expansion of unconventional natural gas in Korea. Also this research evaluate the production of air pollutants and the cost of the damage in power generation sector. The results of this research can be summarized as that natural gas portion of future global energy mix (about 25%) is greater than Korea energy mix (about 12%). This research developed a case that replace 10% energy of power generation sector to natural gas in the 6th demand supply program, reflecting the changed energy mix due to the expansion of natural gas use. In that case, air pollutants would be reduced gradually through 2015 to 2027. In detail, carbon dioxide reduces 22 million tons and environmental damage cost reduces 4500 billion won by 2027.

300 kHz 조건에서의 초음파화학적 산화반응에 대한 연속식 가스 주입 효과 (Effect of Gas Sparging on Sonochemical Oxidation in a 300 kHz Sonoreactor)

  • 서지은;손영규
    • 한국물환경학회지
    • /
    • 제34권6호
    • /
    • pp.642-649
    • /
    • 2018
  • The effect of gas sparging on sonochemical oxidation was investigated in a 300 kHz sonoreactor under various liquid height/volume conditions ($5{\sim}30{\lambda}$, 3.4 ~ 9.0 L), determined by the wavelength of the applied frequency. The electrical input power was maintained constant for all cases . Sonochemical activity drastically decreased from $15{\lambda}$ and the liquid height of $10{\lambda}$ was suggested as the optimal height for 300 kHz without gas sparging. In our previous research, the sonochemical activity observed was five-times higher when air sparging was applied for 36 kHz. On the other hand, no enhancement was obtained at 10, 15, 25 and $30{\lambda}$ using air sparging (1, 3, and 6 L/min) for 300 kHz in this study $20{\lambda}$ and optimization of gas sparging was conducted at $20{\lambda}$ using various gases including air, Ar, $O_2$, $N_2$, and mixtures of Ar and $O_2$. It was found that gas sparging using pure Ar or pure $O_2$ resulted in lower sonochemical activity compared to that of air sparging due to the imbalance between the intensity of cavitation phenomena and the generation of oxidizing radical species. Consequently, the gas mixture of $Ar:O_2$ = 80 % : 20 % (DO saturation ${\approx}100%$) was suggested as an optimal gas sparging condition.

건조공기/에폭시 복합절연물의 AC 파괴전압 분석 (Analysis of AC Breakdown Voltage of Composite Insulation for Dry-Air/Epoxy)

  • 허준;이승수;임기조;정해은;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.289-290
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

오일이용 고온공기 연소시 NOx 저감기술 (An Experimental Study on NOx Emission under the High Temperature Air Combustion with Oil)

  • 양제복;김원배
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.81-88
    • /
    • 2002
  • It's well known that with the increase of preheated air temperature NOx is increasing ,while the energy consumption is decreasing. In this study the experimental study was carried out to find out a new method breaking the above-mentioned old concept. From the variation of configuration of gas nozzle and hot test on the temperature distribution and NOx, it was found out that the reduction of NOx was due to the effect of internal gas recirculation, which will be caused by air emitting velocity from burner nozzle.

  • PDF

기체온도 측정을 위한 초음파 계측 (A ultrasonic technique for measuring gas temperature)

  • 최영;윤천한;전흥신
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1998년도 추계 학술발표회 논문집
    • /
    • pp.150-160
    • /
    • 1998
  • Measuring temperature with ultrasonic wave apparatus is desirable in the case of both below 300$0^{\circ}C$ and ideal gas because of the fact that the temperature of gas is the function of only sound velocity. In this study, being used a heatable wind channel and a blower, the variation of temperature is observed in accordance with diverse flow rate(air velocity). The frequency modulation method is used to measure the temperature which is varying in hot air flow till 10$0^{\circ}C$. The length changed in the position of ultrasonic sensors is considered. Also, the effects of air velocity at the same temperature and various facing angles of ultrasonic sensors are considered. As a result of this study, it has been found that the temperature in gas flow is correctly measured regardless of both the distance of ultrasonic sensors and the variation of air velocity, and that there is just a little influence of facing angles.

  • PDF

Thermal Performance of a Finned-tube Heat Exchanger used in Condensing Gas Boiler

  • Kang, Hie-Chan;Lim, Bok-Bin;Lee, Jung-Man;Kim, Moo-Han
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.61-67
    • /
    • 2009
  • In the present study, an experiment was conducted to investigate the heat and mass transfer performance of heat exchangers used in the condensing gas boiler. Two types of spiral circular fin-tube heat exchangers and a plain tube were tested in the flue gas of propane and dry air. Heat and mass transfer coefficients were measured and compared with the previous correlations. The experimental data for the sensible heat transfer of the plain tube reasonably agreed with the previous correlations for dry air and flue gas. However, the mass transfer coefficient of the plain tube was greater than the previous correlations. The pH, $NO_x$, and $SO_x$ data of condensate were provided.

가압유동층연소로에서 석탄의 연소 및 배가스특성 연구 (A Study on Combustion & Flue Gas Characteristics of Coal at Pressurized Fluidized Bed Combustor)

  • 한근희;오동진;류정인;진경태
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.677-686
    • /
    • 2000
  • The characteristics of combustion and of emissions in pressurized fluidized bed combustor are investigated. The pressure of the combustor is fixed at 6 atm, and the combustion temperatures are set to 850, 900, and $950^{\circ}C$. The gas velocities are 0.9, 1.1, and 1.3 m/s. The excess air ratio is varied from 5 to 35%. The coal used in the experiment is Shenhwa coal in China. All experiments are executed at 2m bed height. Consequently, NOx & $N_2O$ concentration in the flue gas is increased with incresing excess air ratio but $SO_2$ concentration is decreased with incresing excess air ratio. CO concentration is maintained below 100ppm at over 15% of excess air ratio.