• 제목/요약/키워드: Air/Ground Temperatures

검색결과 76건 처리시간 0.027초

도시의 수목이 기온의 조절에 미치는 영향 (Influences of Urban Trees on the Control of the Temperature)

  • 김수봉;김해동
    • 한국조경학회지
    • /
    • 제30권3호
    • /
    • pp.25-34
    • /
    • 2002
  • The purpose of this paper is to discuss the function of microclimate amelioration of urban trees regarding the environmental benefits of street trees in summer, focusing on the heat pollution-urban heat island, tropical climate day's phenomenon and air pollution. We measured the diurnal variation of air/ground temperatures and humidity within the vegetation canopy with the meteorological tower observation system. Summertime air temperatures within the vegetation canopy layer were 1-2$^{\circ}C$ cooler than in places with no vegetation. Due to lack of evaporation, the ground surface temperatures of footpaths were, at a midafternoon maximum, 8$^{\circ}C$ hotter than those under trees. This means that heat flows from a place with no vegetation to a vegetation canopy layer during the daytime. The heat is consumed as a evaporation latent heat. These results suggest that the extension of vegetation canopy bring about a more pleasant urban climate. Diurnal variation of air/ground temperatures and humidity within the vegetation canopy were measured with the meteorological tower observation system. According to the findings, summertime air temperatures under a vegetation canopy layer were 1-2$^{\circ}C$ cooler than places with no vegetation. Due mainly to lack of evaporation the ground surface temperature of footpaths were up to 8$^{\circ}C$ hotter than under trees during mid-afternoon. This means that heat flows from a place where there is no vegetation to another place where there is a vegetation canopy layer during the daytime. Through the energy redistribution analysis, we ascertain that the major part of solar radiation reaching the vegetation cover is consumed as a evaporation latent heat. This result suggests that the expansion of vegetation cover creates a more pleasant urban climate through the cooling effect in summer. Vegetation plays an important role because of its special properties with energy balance. Depended on their evapotranspiration, vegetation cover and water surfaces diminish the peaks of temperature during the day. The skill to make the best use of the vegetation effect in urban areas is a very important planning device to optimize urban climate. Numerical simulation study to examine the vegetation effects on urban climate will be published in our next research paper.

한국의 지중온도를 이용한 기후변화연구 (Climate change in Korea inferred from subsurface temperatures)

  • 이영민;김형찬;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.442-444
    • /
    • 2006
  • On long time scale and over large areas ground surface temperatures (GSTs) track surface air temperatures (SATs). Additionally, GST changes penetrate into the subsurface and are recorded as transient temperature perturbation to the background thermal filed. Therefore, climate change can be reconstructed from borehole temperature measurements We present GST hi story reconstructed from temperature measurements in a borehole at Pocheon The result shows that GST cold period in the late 19th century and then increased by about 2K to 1990. GST history matches well with surface air temperatures measured from 1907 to 2001 at the Seoul Meteorological Station and GST history reconstructed from temperature measurements in three boreholes at Ulsan.

  • PDF

Numerical Prediction of Aviation Fuel Temperatures in Unmanned Air Vehicles

  • Baek, Nak-Gon;Lim, Jin-Shik
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권4호
    • /
    • pp.379-384
    • /
    • 2011
  • This paper performs numerical prediction of fuel temperature in the fuel tanks of unmanned air vehicles for both ground static non-operating and in flight transient conditions. The calculation is carried out using a modified Dufort-Frankel scheme. For this calculation, it is assumed that a non-operating vehicle on the ground is subjected to repeating daily cycles of ambient temperature with solar radiation and wind under 1%, with a 20% probability of hot day conditions. The energy conservation equation is used as the governing equation to calculate heat transfer between the fuel tank surface and the ambient environment. Results of the present analysis may be used as the estimated initial values of fuel temperatures in a vehicle's fuel tank for the purpose of analyzing transient fuel temperatures during various flight missions. This research also demonstrates that the fuel temperature of the front tank is higher than that of the rear tank, and that the difference between the two temperatures increases in the later phases of flight due to the consumption of fuel.

도시녹지의 기온 및 지온 완화효과에 관한 연구 (A Study on the Effect of Air Temperature and Ground Temperature Mitigation from Several Arrangements of Urban Green)

  • 이은엽;문석기;심상렬
    • 한국조경학회지
    • /
    • 제24권1호
    • /
    • pp.65-78
    • /
    • 1996
  • To study the temperature mitigation effects from urban green, several arrangements of green spaces were selected and air/ground temperatures were measured in Chongju city area. The results of this study can be summarized as follows; 1. It was found that the natural ground materials effect more affirmatively on the air and ground temperature than artificial ones do. The best results were recorded from the grass surface presenting highest mitigation effect and lowest daily temperature deviation. 2. Temperature mitigation effects of Tree-Shade on ground are different from season, ground material, and crown-size. Them most effects were found in interlocking block, the least in grass surface among recorded 2 seasons and 3 materials. In case of air temperature, the effects were more or less decreased in most cases. 3. From the survey, it was confirmed that the smaller urban greens can do its role of temperature mitigation as larger ones does. In case of this study, the effect was recorded about 2.3$^{\circ}C$.

  • PDF

에너지슬래브 지중열교환기의 성능 분석 (Performance Analysis of Energy-Slab Ground-Coupled Heat Exchanger)

  • 최종민;손병후
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.487-496
    • /
    • 2012
  • Recently, utilization of building foundations as ground-coupled heat exchangers has attracted much attention because they reduce the cost and enhance the heat transfer. The objective of this study is to evaluate the performance of energy-slab ground-coupled heat exchanger installed in a commercial building. In order to demonstrate the energy transfer characteristics of the energy-slab, experiments were conducted from October 2010 to September 2011. The 1-year measurement results showed that the mean EWTs of brine returning from the energy-slab were $9.6^{\circ}C$ in heating season and $24.9^{\circ}C$ in cooling season, which were in a range of design target temperatures. In addition, the geothermal heat pump system with the energy-slab showed on-off operation according to the setting temperatures of secondary fluid in water storage tank. The results also showed that the energy-slab extracted heat of 198.6 kW from the ground and injected heat of 318.9 kW to the ground, respectively.

지표수 열교환기 적용 지열 히트펌프 시스템의 냉방 성능 (Cooling Performance of Geothermal Heat Pump Using Surface Water Heat Exchanger)

  • 임효재;공형진;손병후
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.316-326
    • /
    • 2017
  • Commercial buildings and institutions are predominantly cooled, thereby dissipating excess heat to a vertical ground heat exchanger (VGHE), than heat extracted over an annual cycle. Surface waters, such as lakes and ponds, provide a cost-effective means of reducing the VGHE length, and in balancing the thermal loads to the ground. This paper presents the measurement and analysis of the cooling performance of ground-coupled heat pump (GCHP) system, using surface water heat exchanger (SWHE) submerged in an artificial pond. In order to measure the performance of the system, we installed monitoring equipment, including sensors, for assessing the temperature and power consumption, after which the operation parameters were determined. The results from the thermal performance test for the SWHE indicate that the temperatures at the outlet of the SWHE and within the pond were affected by outdoor air temperature. In addition, the results reveal similar variation trends on temperatures; however, the peak temperatures of the SWHE were somewhat greater than those of outdoor air, due to the thermal capacity of the pond. Analyzing the cooling performance over the measurement period, the average coefficient of performance (COP) of heat pump was found to be 5.71, while that for the entire system was 2.99.

시뮬레이션을 통한 에너지파일 적용 지열 히트펌프 시스템의 성능 예측 (Performance Prediction of Geothermal Heat Pump(GHP) System with Energy Piles Using Simulation Approach)

  • 손병후;최종민
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.155-163
    • /
    • 2012
  • The aim of this study is to evaluate the performance of the GHP system with 150 energy piles for a commercial building. In order to demonstrate the feasibility of a sustainable performance of the system, simulations were conducted over 1-year and 20-year periods, respectively. The 1-year simulation results showed that the maximum and minimum temperatures of brine returning from the energy piles were $23.80^{\circ}C$ and $7.90^{\circ}C$, which were in a range of design target temperatures. In addition, after 20 years' operation, these returning temperatures decreased slowly to $23.05^{\circ}C$ and $6.98^{\circ}C$, and finally reached to stable state. The results also showed that the energy piles injected heat of 65.6 MWh to the ground and extracted heat of 96.0 MWh from the ground, respectively. Also, it is expected this GHP system with energy piles can operate with average SPF of more than 4.15 for long term.

터널 라이닝 내부에 설치한 열교환기의 현장모니터링 연구 (Study on long-term monitoring of heat exchanger installed in the tunnel lining)

  • 이철호;박문서;최항석;손병후;정재형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.195.1-195.1
    • /
    • 2011
  • This paper presents an experimental study on a new potential geothermal energy source obtained from tunnel structures. An "energy textile", which is a textile-type ground heat exchanger, was fabricated between a shotcrete layer and a guided drainage geotextile in the tunnel lining system. To examine the long-term thermal behavior of the energy textile, the difference in temperatures of the inlet and outlet fluid circulating through the heat exchange pipe within the energy textile was monitored using a constant-temperature water bath. Daily heat exchange rate of the energy textile during cooling operation was estimated from the measured temperatures of the inlet and outlet fluid through the energy textile. The air and ground temperature was also continuously monitored. The operation of the energy textile as a ground heat exchanger was simulated using a 3D numerical CFD model (Fluent). The thermal conductivity of shotcrete and concrete lining components and temperature variation of air in the tunnel were incorporated in the model. The numerical analysis shows a good agreement with the long-term monitoring result.

  • PDF

지열원 히트펌프 시스템에 적용되고 있는 난방용 적산열량계의 신뢰성 평가에 관한 연구 (A Study on the Reliability of District Heat Measuring Devices for Ground Source Heat Pump Systems)

  • 강희정;이현수;장명훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2018
  • A ground source heat pump system should be equipped with devices to measure the generated heating or cooling heat amount in Korea. Generally, the heat measuring devices have been developed to estimate consumed heat amount in residential or commercial buildings from a central air-conditioning system or a district heating system. In this study, two representive heat measuring devices used for buildings were selected, and the accuracy of them were experimentally estimated at the ground source heat pump operating conditions. The obtained heat amounts from the heat measuring devices were deviated within 4.3% comparing with the precise values calculated from an accredited test facility. Even though the accumulated heat amount values of the heat measuring devices had a small difference comparing with the precise values, the temperatures of heat measuring devices showed greatly different values comparing with the precise temperature. Therefore, it is highly recommended to develop the heat measuring devices which is appropriate for the ground source heat pump systems.

한라산 아고산대의 동결기 기온 및 지온변화 (Variationsin Air and Ground Temperatures During a Frozen Season in the Subalpine Zone of Mt. Halla)

  • 김태호
    • 한국지형학회지
    • /
    • 제20권3호
    • /
    • pp.95-107
    • /
    • 2013
  • 한라산 아고산대 표고 1,710m 지점의 나지에서 동결기를 중심으로 212일간 지상 55cm 높이의 기온과 지중 2cm, 10cm 및 20cm 깊이의 지온을 관측하여 주빙하성 지형형성환경을 조사하였다. 관측기간의 평균기온은 $-0.1^{\circ}C$이며, 깊이별 평균지온은 2cm $1.8^{\circ}C$, 10cm $2.6^{\circ}C$, 20cm $3.2^{\circ}C$이다. 2cm 깊이에서는 1월부터 3월까지 영하의 월평균지온이 관측되었으나 다른 깊이에서는 출현하지 않았다. 동결융해 사이클의 출현횟수는 55cm 높이에서 72회인 반면 지중 2cm 깊이에서 17회, 10cm 깊이에서 8회, 20cm 깊이에서 3회로 지중으로 내려가면서 크게 감소하였다. 지상과 2cm 깊이에서의 동결융해는 일일 주기가 탁월한 반면 10cm와 20cm 깊이에서는 수일 주기로 출현하였다. 또한 2cm 깊이에서 12월 중순~4월 중순, 10cm 깊이에서 2월 말~4월 중순, 20cm 깊이에서 4월 초순~중순에 일평균지온이 대체로 $0^{\circ}C$ 밑으로 내려가는 계절적 동결기가 출현하였다. 관측지점은 1월부터 4월 초순까지 55cm 이상의 눈으로 덮여 있다가 4월 16일에 전부 사라졌다. 12월 하순 2cm 깊이에 형성된 계절적 동토층은 적설의 단열효과로 인하여 3월 말~4월 초에 10cm 깊이에 도달하였다. 4월 7일부터 14일까지 깊이 20cm를 넘는 최대동결심을 보이나 이후 급속하게 융해되어 17일 이후 계절적 동토층은 출현하지 않았다. 융해진행기에도 잔설이 남아 있는 관측지점에는 융해진행기보다 동결진행기에 주빙하 프로세스가 더 탁월하게 진행되며, 일주기성 동결융해 사이클의 발생심도와 최대동결심을 고려하면 한라산 아고산대의 사면물질이동은 주로 동상포행에 의해 발생한다.