• 제목/요약/키워드: Aging Resistance

검색결과 426건 처리시간 0.033초

Au/Ag 이중층 전극 구조를 이용한 페로브스카이트 태양전지 (Au/Ag Bilayer Electrode for Perovskite Solar Cells)

  • 이준영;조성진
    • 한국재료학회지
    • /
    • 제32권1호
    • /
    • pp.51-55
    • /
    • 2022
  • Generally, Au electrodes are the preferred top metal electrodes in most perovskite solar cells (PSCs) because of their appropriate work function for hole transportation and their resistance to metal-halide formation. However, for the commercialization of PSCs, the development of alternative metal electrodes for Au is essential to decrease their fabrication cost. Ag electrodes are considered one of the most suitable alternatives for Au electrodes because they are relatively cheaper and can provide the necessary stability for oxidation. However, Ag electrodes require an aging-induced recovery process and react with halides from perovskite layers. Herein, we propose a bilayer Au/Ag electrode to overcome the limitations of single Au and Ag metal electrodes. The performance of PSCs based on bilayer electrodes is comparable to that of PSCs with Au electrodes. Furthermore, by using the bilayer electrode, we can eliminate the aging process, normally an essential process for Ag electrodes. This study not only demonstrates an effective method to substitute for expensive Au electrodes but also provides a possibility to overcome the limitations of Ag electrodes.

Behavior of structures repaired by hybrid composite patches during the aging of the adhesive

  • Habib Achache;Rachid Zahi;Djaafar Ait Kaci;Ali Benouis
    • Structural Engineering and Mechanics
    • /
    • 제91권2호
    • /
    • pp.135-147
    • /
    • 2024
  • The objective of this study is to analyze, using the finite element method, the durability of damaged and repaired structures under the effect of mechanical loading coupled with environmental conditions (water absorption and/or temperature). The study is based on the hybrid patch repair technique, considering several parameters based on the J integral to observe the behavior of the adhesive in transferring load from a damaged plate to the repair patch. The results clearly show that water absorption and increased temperature cause degradation of the mechanical properties of the adhesive, leading to an increase in its plasticization, which is beneficial for the assembly's strength. However, the degradation of the adhesive's properties due to aging in the repair results in poor load transfer from the damaged area to the patch. The findings of this study allowed the authors to conclude that the [0°]8 sequence consistently offers the best performance, with the lowest J integral values and superior crack resistance. The lowest the J integral for the [0°]8 stacking sequence is typically 3-7% lower than that of the [0/-45/45/90]S and [0/-45/90/45]S sequences at elevated temperatures. At 60℃, the J integral increases by approximately 3-6% compared to 40℃ and 20, depending on the aging duration and stacking sequences.

Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul;Kim, Jae Ho
    • Safety and Health at Work
    • /
    • 제11권4호
    • /
    • pp.405-417
    • /
    • 2020
  • Background: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. Methods: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets' conductor surface and content, insulator weight, and thermal deformation temperature. Results: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 ℃. In relation to the installation year (30 years), insulation resistance decreased from 70 ℃, which is as much as 40 ℃ lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. Conclusion: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 ℃ of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 ℃. It is necessary to manage electrical socket outlets that have been installed for a long time.

고지방·고단순당 식이 섭취 마우스에서 토종보리수 열매의 인슐린 저항성 및 고혈당 개선 효과 (Effects of autumn olive berry on insulin resistance and hyperglycemia in mice fed a high-fat, high-sucrose diet)

  • 최하늘;조애진;김하나;김정인
    • Journal of Nutrition and Health
    • /
    • 제57권1호
    • /
    • pp.16-26
    • /
    • 2024
  • 토종보리수 열매의 항당뇨 효과를 규명하기 위하여, 마우스를 네 군으로 나누어, 기본 식이, 고지방·고단순당 식이, 토종보리수 열매 추출물을 저농도 (0.5%) 및 고농도 (1.0%)로 첨가한 고지방·고단순당 식이를 12주간 제공하였다. 고지방·고단순당 식이를 섭취한 군은 대조군에 비해 체중 및 체중 증가량, 부고환 지방무게가 유의적으로 증가하였으나, 고농도 보리수 열매 추출물의 급여는 부고환 지방무게를 유의적으로 감소시켰다. 고지방·고단순당군은 대조군에 비해 혈당, 인슐린, HOMA-IR값이 유의적으로 증가하였으나, 고농도 보리수 열매 추출물은 인슐린 농도를 감소시켰고, 저농도 및 고농도 추출물은 혈당 및 HOMA-IR값을 감소시켰다. 고지방·고단순당군은 대조군에 비해 IRS-2 및 AMPK 단백질 발현도가 유의적으로 감소하였으나, 고농도 보리수 열매 추출물의 급여는 IRS-2 발현도를 증가시켰고, 저농도 및 고농도 보리수 열매 추출물의 급여는 AMPK 발현도를 증가시켰다. 따라서, 토종보리수 열매는 제2형 당뇨병 동물에서 인슐린 저항성을 개선시켜 고혈당 개선효과를 나타낸 것으로 나타났다. 고지방·고단순당 식이를 섭취한 마우스에서 저농도 및 고농도 토종보리수 열매 추출물의 급여는 혈청 중성지방 농도 및 간조직의 총 지질과 중성지방 함량을 감소시켰고, 고농도추출물의 급여는 혈청 콜레스테롤 농도를 감소시켜, 토종보리수 열매는 지방간과 이상지질혈증 개선효과를 나타내었다.

ASSESSMENT OF PROPERTIES AND DURABILITY OF FLY ASH CONCRETE USED IN KOREAN NUCLEAR POWER PLANTS

  • Cho, Myung-Sug;Noh, Jae-Myoung
    • Nuclear Engineering and Technology
    • /
    • 제44권3호
    • /
    • pp.331-342
    • /
    • 2012
  • Since the opening of the Shin-Kori #1,2 in 2005, fly ash mixed concrete has been used for NPP concrete structures under construction in Korea with the aim of preventing aging and improving durability. In this paper, the quality suitability of fly ash manufactured in Korea is assessed and the basic physical properties of fly ash mixed concrete and its durability against primary causes of aging are verified through experimental methods. Because of the internal structure filling effect from the pozzolanic reaction of fly ash and the resulting improvements in mechanical performance in such areas as strength and salt damage resistance, the durability of fly ash mixed concrete is shown to be superior. It is judged that this result can be applied in measures not only for improving the safety of NPP structures in operation in Korea but also for implementing effective structure life management should extending the life of structures be needed in the future.

동맥계 다채널 용적맥파 특징 파라미터 분석에 관한 연구 (Analysis of multi-channel photoplethysmograph parameter by the changes of arterial characteries)

  • 한순천;김형조;김형태;김정국;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2745-2748
    • /
    • 2003
  • In this paper, we implement the photoplethysmo-graphy system that have three channel pulse wave detects and one channel ECG amplifier. In order to detect the artery state, we measured the pulse waves at different positions, simultaneously. In general, arterial vascular system suffers the decrease of compliance, increase of resistance, and decrease of distensibility through aging. Therefore, we compared and analyzed variation of tile Pulse waves parameter both in time and frequency domains that is concerned with the changes of arterial characteries. And then evaluated the correlation coefficients between the parameters variation and the age group. As the result of experiment, we found that the Parameters have a significant correlation about aging.

  • PDF

고로슬래그미분말 치환 콘크리트의 염화물 침투특성에 관한 연구 (A Study on the Chloride ion Penetration Characteristic of Concrete containing Ground Granulated Blast Furnace Slag)

  • 김현수;지남용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.997-1002
    • /
    • 2001
  • There are two types of chloride in concrete; one is added as concrete materials' chloride when concrete's mixing, and .the other is penetrated from the air and sea water in the sea-shore area. These chlorides penetrate into concrete, and they are accumulated inside the concrete with aging. This study aimed to evaluate the chloride ion penetration resistance of concrete containing GGBFS in the sea-shore area. Therefore, the specimens made with the replacement ratios(0, 0.30, 0.45, 0.60) of GGBFS were put into 3% NaCl solution according to the chloride accelerating test of JCI-SC3, and then investigated the weight changes, compressive strength, chloride ion with the depths of the specimens by aging. The result is that the diffusion coefficient of chloride ion is decreased with the increase of replacement ratios when compared to OPC

  • PDF

폴래머애자의 트래킹 특성에 미치는 염수농도의 영향 (Effect of the Salinity Level on Tracking Characteristics of Polymer Insulators)

  • 한재홍;송일근;김동명;정종욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.74-77
    • /
    • 2001
  • In order to investigate the effect of salinity level on tracking characteristics of polymer insulators for distribution power systems, tracking tests were performed by tracking wheel tester under different salt concentration. In this study, 6 kinds of polymer insulators were tested under 2200 ${\mu}\textrm{s}$/cm and 4000${\mu}\textrm{s}$/cm salinity. The salinity level has a significant effect on the tracking characteristics. Namely, most polymer insulators showed the good tracking resistance in case of low salinity level. But, in case of high salinity level some polymer insulators showed the excessive erosion and tracking. These phenomena may come from the different aging mechanism. It can be concluded that too high salinity level is not desirable in aging test of polymer insulators.

  • PDF

열처리 조건에 따른 티타늄합금의 와이어 방전가공 (Wire electrical discharge machining of titanium alloy according to the heat treatment conditions)

  • 김종업;왕덕현;김원일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.930-933
    • /
    • 2001
  • Titanium Alloys used in this experiment has an good corrosion resistance and specific strength, and is the new material developed for medical supplies living goods. In this study the rolled titanium alloy is done by annealing, solution heat-treatment and aging and then is worked by wire EDM. With changing the process conditions, the process properties of surface hardness, surface roughness, shape of process surface and the analysis of ingredients are measured through experiment repeating main cut and finish cut. It is confirmed to gain good measure values as increasing the number of processing of wire EDM. In this experiment the phenomena of processing is studied and the appropriate process condition is proposed.

  • PDF

외부환경적 가속시혐에 의한 PV모듈의 열화성능 분석 (Analysis of Photovoltaic module's Phenomena of aging with Acceleration Test)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1151-1152
    • /
    • 2006
  • In this paper, we examined 10 domestic samples of three different model using thermal, humidity freeze, thermal-endurance and damp heat test under IEC61215 photovoltaic module environmental endurance test condition. Three was almost no changes on power generation. Insulation resistance capacity was much higher than judgement standard but, showed unstable results depending on environmental test items. On external appearance test, there were two models which showed bubble, humidity penetration, seal melted frame phenomenon. From this results, the degree of aging under the external environment is a main cause that shortens photovoltaic module life time. So it is considered that the efforts for finding optimum condition of manufacturing process should be needed.

  • PDF