• Title/Summary/Keyword: Aging Measurement

Search Result 468, Processing Time 0.026 seconds

Tree aging observation of XLPE by image processing (화상처리에 의한 XLPE의 트리열화관측)

  • 임장섭;김태성;길촌승
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.551-557
    • /
    • 1995
  • For the observation of treeing, a visual measurement with an optical microscope has been used to explain breakdown mechanism in high-voltage systems. The conventional directed visual method of tree aging observation is difficult to measure in short time processing, and it is impossible to analyze on tree degradation area, progressed direction, tree pattern, etc. By using an image processing technique, the tree features which appear immediately after the tree initiation as well as changes in the configuration of the tree can be easily measured and observed than using the conventional visual methods. In this paper, we have developed a tree observating system by using image processing for tree growth, degradation area and other treeing progress. As an experimental result, it can be concluded that the image processing method is a more effective alternative than directed visual observation method. As a matter of fact, it is possible to record the image of tree propagation immediately after its first appearance and explain the characteristics of tree growth froth the computer processing image.

  • PDF

Preliminary Study to Develop the Korean Medical Pathologic Aging Scale and Korean Medical Pattern Identification for Dementia (한의학 병리적 노화 척도와 치매 한의학적 변증진단 개발 및 신뢰도 평가)

  • Lee, Go eun;Moon, Kwang Su;Kim, Nam Kwen;Chung, sun yong;Jung, In Chul;Kang, Hyung Won
    • The Journal of Korean Medicine
    • /
    • v.38 no.3
    • /
    • pp.111-123
    • /
    • 2017
  • Objectives: To develop and investigate the reliability of the pathologic aging scale based on korean medical theory and korean medical pattern identification for dementia. Methods: We searched the textbook of korean neurophychiatry and Donguibogam and selected items through professional consensus. We compared between dementia(n=40) and normal elderly(n=38) and tested the reliability of two scales. Results: After professional consensus, we drafted the Korean Medical Pathologic Aging Scale(12 items, Likert 3 scale) and Korean Medical Pattern Identification for Dementia(4 patterns, 28 items, Likert 5 scale). On Korean Medical Pathologic Aging Scale, There is no significant difference between two groups. We had good internal consistency(Cronbach's alpha = 0.6) and test-retest reliability(r=0.631) but low inter-rater reliability(r=0.430). On Korean Medical Pattern Identification for Dementia, dementia patients diagnosed with Qi deficiency are significantly more than those in normal group. We had fairly good internal consistency(Cronbach's alpha = 0.574) and excellent test-retest(kappa= .800) and inter-rater reliability(kappa = .733). Conclusions: Korean Medical Pattern Identification for Dementia is appropriate for diagnosing korean medical pattern. But Korean Medical Pathologic Aging Scale isn't appropriate to discriminate dementia from normal elderly because of many subjective items. Therefore objective measurement of sensory dysfunction would be needed to measure pathologic aging based on korean medical theory.

Somatotype Classification for Children's Clothing Bodice Pattern (유아복 길 원형 설계를 위한 체형 분류)

  • Kim, Hyon-Jin;Hong, Jung-Min;Lee, Young-Ju
    • Fashion & Textile Research Journal
    • /
    • v.6 no.1
    • /
    • pp.102-108
    • /
    • 2004
  • The anthropometric measurement and the photometric measurement for have been conducted 358 children from 4 years old to 6 years old to design children's clothing. The characteristics of body type were grasped among total 44 measurement items according to the aging, being extracted seven factors from factor analysis. From cluster analysis among the seven factors the three body types were classified. Type 1 shows low fat body with a small figure and short upper body. The body has a round belly and waist. Type 2 shows the fattest body with an average height. The body has been backed with lower shoulders. Type 3 shows common fat body with a high height and a big figure. The body shows crooked round back with a big upper body and rising shoulders.

A Study on the Remain Life with Aging in 22kV CV cable (22kV 전력케이블의 열화 판정에 관한 연구)

  • Lee, Kwan-Woo;Mok, Young-Soo;Kim, Bo-Kyeong;Park, Bok-Ki;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.19-21
    • /
    • 2003
  • In this paper, we studied on life-decision of underground cable of live-lines state. As all equipments have been wear, underground cables decided design-life on the whole 30 years because underground cable have been occurred aging as time goes. CV cable has been become about 30 years after installation in the South Korea, is come to a important point of time with estimation about life. Study target cable is 22 kV CV cables in this point of view and installation cable is about 10 years before and behind. Measurement method used dc leakage method of live-lines state that applied voltage of 50V in neutral point and data is analyzing result that is measured during 5 years. In this result, insulation resistance could confirm that change according to season and cause is effect of humidity, seasons and load current. Also, according as data is gone aging, insulation resistance by Weibull distribution could confirm functionally its decrease. As a result, the aging speed of cable that water tree is gone could confirm fastness very. Numerical analysis result, cable that water tree is not gone could confirm that life of cable that has passed 10 years remains about $10{\sim}20$ years.

  • PDF

Investigation on Age-hardening characteristic of thixo and rheocast by using Nano/Micro-probe Technology (나노/마이크로 프로브 기술을 통한 틱소/레오 캐스트의 시효경화 특성 조사)

  • Cho, S.H.;Lee, C.S.;Kang, C.G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.322-325
    • /
    • 2006
  • The nano/microstructure and mechanical properties of the eutectic regions in thixo and rheo cast A356 alloy parts were investigated using nano/micro-indentation and mechanical scratching, combined with optical microscopy and atomic force microscope (AFM).Most eutectic Si crystals in the A356 alloy showed a modified morphology as fine-fibers, however Si particles of network in eutectic region was formed quickly with aging time increase in thixo-cast. The aging responses of the eutectic regions in both the thixo and rheo cast A356 alloys aged at $150^{\circ}C$ for different times (0, 2, 4, 8, 10, 16, 24, 36, and 72 h) were investigated. Both Vickers hardness ($H_V$) and indentation ($H_{IT}$) test results showed almost the same trend of aging curves, the peak was obtained at the same aging time of 10 h.

  • PDF

Analysis on the Aging Process of ac-Plasma Display Panel

  • Park, Min-Soo;Park, Deok-Hai;Kim, Bo-Hyun;Ryu, Byung-Gil;Kim, Sung-Tae;Seo, Gi-Weon;Kim, Dae-Young;Park, Seung-Tea;Kim, Jong-Bin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.126-129
    • /
    • 2006
  • AC-plasma display panels were examined before and after the aging process to analyze the effect of the aging process. The gas analysis was done to detect the impurity gases out of the MgO film and phosphor by a residual gas analyzer. There were no differences found in the components. The MgO film was analyzed to find out the effect of an ion bombardment due to discharge. The surface roughness of the MgO film was different from regional groups due to the different degree of ion bombardments. XPS analysis showed that the 8 hour aging process was not sufficient to remove $Mg(OH)_2$ and $MgCO_3$ existed on the MgO surface. Photoluminescence measurement showed the small deterioration of blue and green phosphor.

  • PDF

The Energized Aging Property of Pole Mount Mold transformer by Back-to-back Method (반환부하법에 의한 옥외 주상용 몰드변압기의 과전열화 특정)

  • Hwang, Bo-Guk;Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.484-487
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. In this paper, the proto type mold transformer of 50kVA class is investigated by routine, type, special test. The outdoor energized aging test is investigated by back-to-back method to verify the long time performance of pole mold transformer. The aging process of transformer is analyzed by various diagnosis method such as DC voltage-current test, $tan{\delta}$, Meggar measurement, winding temperature and etc.

  • PDF

Evaluation of Age-Hardening Characteristics of Rheo-Cast A356 Alloy by Nano/Micro Hardness Measurement (나노/마이크로 경도 측정에 의한 레오캐스트 A356 합금의 시효경화특성 평가)

  • Cho S. H.;Youn S. W.;Kang C. G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.471-474
    • /
    • 2005
  • This study investigates the nano/microstructure, the aging response, and the mechanical/tribological properties of the eutectic regions in rheoformed A356 alloy-T5 parts using nano/micro-indentation and mechanical scratching, combined with optical microscopy and atomic force microscope (AFM). Most eutectic Si crystals in the A356 alloy showed a modified morphology as fine-fibers. The loading curve for the eutectic region was more irregular than that of the primary Al region due to the presence of various particles of varying strength. The aging responses of the eutectic regions in the rheoformed A356 alloys aged at $150^{\circ}C$ for different times (0, 2, 4, 8, 10, 16, 24, 36, and 72 h) were investigated. Both Victors hardness $(H_v)$ and indentation $(H_{IT})$ test results showed a similar trend of aging curves, and the peak was obtained at the same aging time of 10 h. A remarkable size-dependence of the tests was found.

  • PDF

Ginsenoside Rg3 promotes inflammation resolution through M2 macrophage polarization

  • Kang, Saeromi;Park, Soo-Jin;Lee, Ae-Yeon;Huang, Jin;Chung, Hae-Young;Im, Dong-Soon
    • Journal of Ginseng Research
    • /
    • v.42 no.1
    • /
    • pp.68-74
    • /
    • 2018
  • Background: Ginsenosides have been reported to have many health benefits, including anti-inflammatory effects, and the resolution of inflammation is now considered to be an active process driven by M2-type macrophages. In order to determine whether ginsenosides modulate macrophage phenotypes to reduce inflammation, 11 ginsenosides were studied with respect to macrophage polarization and the resolution of inflammation. Methods: Mouse peritoneal macrophages were polarized into M1 or M2 phenotypes. Reverse transcription-polymerase chain reaction, Western blotting, and measurement of nitric oxide (NO) and prostaglandin $E_2$ levels were performed in vitro and in a zymosan-induced peritonitis C57BL/6 mouse model. Results: Ginsenoside $Rg_3$ was identified as a proresolving ginseng compound based on the induction of M2 macrophage polarization. Ginsenoside $Rg_3$ not only induced the expression of arginase-1 (a representative M2 marker gene), but also suppressed M1 marker genes, such as inducible NO synthase, and NO levels. The proresolving activity of ginsenoside $Rg_3$ was also observed in vivo in a zymosan-induced peritonitis model. Ginsenoside $Rg_3$ accelerated the resolution process when administered at peak inflammatory response into the peritoneal cavity. Conclusion: These results suggest that ginsenoside $Rg_3$ induces the M2 polarization of macrophages and accelerates the resolution of inflammation. This finding opens a new avenue in ginseng pharmacology.

Characterization of Acetylene Plasma-Polymer Films: Recovery of Surface Hydrophobicity by Aging

  • Kim, Jeong-Ho;Kim, Tae-Hyung;Oh, Jung-Geun;Noh, Seok-Hwan;Lee, Jeong-Soo;Park, Kyu-Ho;Ha, Sam-Chul;Kang, Heon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2589-2594
    • /
    • 2009
  • Aging phenomena of plasma polymer films were studied by using the surface analysis techniques of contact angle measurement, X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (TOFSIMS), and atomic force microscopy (AFM). The polymer films were grown on an aluminum substrate by using a plasma polymerization method from a gas mixture of acetylene and helium, and the films were subsequently modified to have a hydrophilic surface by oxygen plasma treatment. Aging of the polymer films was examined by exposing the samples to water and air environments. The aging process increased the hydrophobicity of the surface, as revealed by an increase in the advancing contact angle of water. XPS analysis showed that the population of oxygen-containing polar groups increased due to the uptake of oxygen during the aging, whereas TOF-SIMS analysis revealed a decrease in the polar group population in the uppermost surface layer. The results suggest that the change in surface property from hydrophilic to hydrophobic nature results from the restructuring of polymer chains near the surface, rather than compositional change of the surface. Oxidative degradation may enhance the mobility and the restructuring process of polymer chains.