전력케이블내 반도전 재료의 전기적 및 기계적 특성; 체적저항과 Stress-Strain 측정 (Electrical and Mechanical Properties of Semiconductive Shield in Power Cable; Volume Resistivity and Stress-Strain Measurement)

  • 이경용;양종석;최용성;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.45-50
    • /
    • 2005
  • To improve mean-life and reliability of power cable, in this study, we have investigated electrical properties and stress-strain showing by changing the content of carbon black that is semiconductive additives for underground power transmission. Specimens were made of sheet form with the nine of specimens for measurement. Volume resistivity of specimens was measured by volume resistivity meter after 10 minutes in the pre-heated oven of both 25±1 [℃] and 90±1 [℃]. And stress-strain of specimens was measured by TENSOMETER 2000. A speed of measurement was 200[mm/min], ranges of stress and strain were 400[Kgf/㎠] and 600[%]. In addition tests of stress-strain were progressed by aging specimens in air oven. From this experimental results, volume resistivity was high according to increasing the content of carbon black. And yield stress was increased, while strain was decreased according to increasing the content of carbon black. And stress-strain were decreased some after aging because of oxidation reaction of chemical defect. We could know EEA was excellent more than other specimens from above experimental results.

광섬유센서를 이용한 우주환경하에서 복합재료 적층시편의 노화에 따른 열팽창계수변화 측정 (Measurement of CTE Change in a Composite Laminate with Aging under Space Environment using Fiber Optic Sensors)

  • 강상국;강동훈;김천곤;홍창선
    • 한국항공우주학회지
    • /
    • 제31권10호
    • /
    • pp.21-26
    • /
    • 2003
  • 본 논문에서는 광섬유 센서를 사용하여 우주환경하에 노출된 그래파이트/에폭시 복합재 적층판의 열팽창계수의 변화를 측정하였다. 열변형률과 온도를 동시에 측정하기 위해서 두개의 FBG 센서를 사용하였다. 또한 열-진공 챔버를 사용하여 고진공, 자외선, 열적 사이클 등의 인자를 가지는 저궤도(LEO) 우주환경을 모사하였다. 예비실험으로써, 본 실험에서 사용되는 온도범위에 대해 FBG 온도센서를 기준온도계로부터 보정하였고 알루미늄 시편에 부착된 FBG 변형률 센서와 변형률 게이지(ESG)의 비교실험을 통해 FBG 변형률 센서의 사용가능성을 검증하였다. 검증된 FBG센서가 삽입된 그래파이트/에폭시 복합재 평판을 모사된 우주환경에 노출하여 일정한 노화간격마다 열팽창계수 변화를 실시간으로 측정하였다. 실험결과 1000 사이클 노화후의 열팽창계수는 노화전에 비해 대체적으로 큰 변화는 없었지만 전 온도구간에서 약간 감소하는 경향을 보였다. 이러한 현상은 가스방출(outgassing), 수분방출, 모재균열 등에 기인한다.

열분석법에 의한 Mg-8.5Li-4.5Al합금의 시효거동 연구 (A Study on the Aging Behavior of a Mg-8.5Li-4.5Al alloy by Differential Scanning Calorimetry)

  • 김영우;황영하;박태원;김도향;홍준표
    • 열처리공학회지
    • /
    • 제10권4호
    • /
    • pp.255-265
    • /
    • 1997
  • Precipitation and strengthening mechanisms in squeeze cast Mg-8.5wt%Li-4.5wt%Al have been investigated by differential scanning calorimetry(DSC), scanning electron microscopy(SEM), in-situ and ex-situ X-ray diffraction analysis and hardness measurement. Special emphasis was placed on the investigation of the precipitation behavior by the DSC technique. Microstructural and calorimetric analysis showed that ${\theta}$ and ${\delta}$ precipitates in the b.c.c. ${\beta}$ phase matrix, forming two exothermic peaks at the temperature ranges of $130^{\circ}C{\sim}180^{\circ}C$ and $236^{\circ}C{\sim}280^{\circ}C$. ${\theta}$ and ${\delta}$ dissolve into the matrix forming an endothermic peak at the temperature range of $280^{\circ}C{\sim}352^{\circ}C$. The as-cast microstructure consists of ${\alpha}$, ${\beta}$ and ${\delta}$. Peak strength was obtained after aging for 1 hour at $50^{\circ}C$. The aging time required for the peak strength decreased as the aging temperature increases. The hardness decrease during overaging was due to the coarsening of ${\theta}$ precipitates. Microhardness measurement showed that variation of the hardness of ${\beta}$ matrix was more pronounced than that of the ${\alpha}$ phase, indicating that the ${\beta}$ phase is more responsible for the strengthening of the Mg-8.5wt%Li-4.5wt%Al alloy.

  • PDF

전차선 편위 및 높이 측정 시스템 개발에 관한 연구 (A Study on the Development of Catenary stagger and height Measurement System)

  • 송성근;박성모
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.299-304
    • /
    • 2008
  • Catenary and Pantograph are a power supply devices for electric trains and shall be steadily contacted. Rail catenary must be installed precisely and managed for stable train operations. But external factors such as weathers, nature, etc., or aging affect catenary geometry. Changed catenary height causes high voltage spark or instant electric disconnection. Big spark and disconnection damage pantograph shoe and catenary coating and might interrupt rail operations. To prevent a big scale spark or electric disconnection catenary maintenance shall be required with catenary geometry measurement systems. In this paper, we describe the development of catenary height and stagger measurement system. The catenary height and stagger measurement system uses Acuity company's AR4000 Range Finder for distance measurement and AccuRange Line Scanner for degree measurement. This system reports suspicious overhead line sections with excessive height and stagger variance.

  • PDF

고조파가 몰드변압기 수명에 미치는 영향분석 (Effect of Harmonics on the Cast-Resin Transformer Life Cycle)

  • 강창섭;이홍기;이은철;윤덕량
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.118-120
    • /
    • 1996
  • We've been reported recently that increase of installing big power converting equipment which makes harmonics result in damage on transformer for incoming and load. Specially, harmonics that cause overheat and aging is severer in cast-resin transformer a kind of dr type than in oil one. The goal of this paper is to prove the process for aging of transformer that result from harmonics in according to both of theory and actual measurement on site. And we introduce diagnostic methods to estimate aging condition of cast-resin transformer in accordance with simulation.

  • PDF

전기적 방법을 이용한 전력용 콘덴서 열화특성 연구 (A Study on the Aging Characteristics of Power Capacitors using Electrical Methods)

  • 김은식;김영욱;김종서;윤철섭;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 1998
  • Power capacitors are highly reliable equipment due to their completely enclosed configuration. Aging diagnosis system using partial discharge(PD) and acoustic emission(AE) is being highlighted as a research area for degradation of power capacitors. Their dielectric strength can be however reduced due to some stresses such as over-voltage or thermal degradation of the insulation material during their long period of operation. In this paper, it has been developed to express the AE of the EVENT(average amplitude) and HIT(pulse count) according to the source location. And real time measurement of PD signals for aging diagnosis of power capacitors.

  • PDF

Pulse waveform을 이용한 Toner type particles의 Aging 효과 (Effect of aging toner type particles using pulse waveform)

  • 오유미;김경수;김성운;윤해상;박선우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.142-142
    • /
    • 2010
  • This research proposed an advanced Electronic bead (EB) using MMA (Methy methacrylate) and CCA (Charge Control Agent). In the first, this paper presents about measurement method and characterization analysis of EB and nano-silica with pulse waveform in aging. Furthermore; this work presents the positive and negative EB fabrication procedure. As the experimental results, the proposed EB with square waveform is very attractive to Electronic paper driving characterization.

  • PDF

전동차 견인전동기 고장진단시스템 (Fault Diagnosis System for Traction Motor in Electric Multiple Unit)

  • 박현준;장동욱;이길헌;최종선;김정수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.518-521
    • /
    • 2003
  • A new measurement system was developed by fault diagnosis system for traction motor using current signal analysis. The motor current signature analysis method is used for traction motor fault diagnosis. The diagnosis system program is constructed by artificial neural networks algorithm, those results from the program are used to train neural networks. The trained neural networks have the ability to compute adaptive results for non-trained inputs, and to calculate very fast due to original parallel structure of neural networks with high accuracy within destined tolerance. This system suggested that available test for checking, the probable extent of aging, and the rate of which aging is taking place.

  • PDF

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.

전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석 (Properties on the Distribution Pattern of Discharge Signals Generated in the Power Cable)

  • 소순열;홍경진;이우기;이동인;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.13-18
    • /
    • 1998
  • After Computer-based PD measurement was referred in the 1970's, the new technology and a number of digital system have been studied. And the selection of PD patterns, extraction of relevant information for PD recognition are discussed because the number of pulse as a function of discharge magnitude and discharge pulse as a function of the power frequency cycl4e offer the information of the aging insulation. This paper investigates the discharge phase($\phi$) and magnitude(q), as well as the number of discharge(n) with regard to discharge signals generated in power cable. Therefore, according to properties analysis on the distribution of $\phi$ , q and n, it is able to apply in the aging analysis of power cable which visual observation is impossible and distribution change of discharge signals offers much information for risk degree on aging progress of insulation materials.

  • PDF