• Title/Summary/Keyword: Aggregate Ratio

Search Result 1,126, Processing Time 0.025 seconds

Effect of Recycled Fine Aggregate Quality on Strength Properties of Concrete (순환잔골재 품질에 따른 콘크리트의 강도특성)

  • Jeon, Esther;Yun, Hyun-Do;Jang, Yong-Heon;Choi, Ki-Sun;Bae, Kee-Sun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.609-612
    • /
    • 2008
  • This study investigated effect of recycled fine aggregate quality on strength properties of concrete. Some investigations have been carried out to study the strength properties of recycled aggregate concrete. But these have some limitation due to small-scale test in the laboratory. Therefore concrete using this study were fabricated by ready-mix concrete. Variables were quality of recycled fine aggregate(high and low quality) and replacement ratio of 0%, 30%, 60%, 100%(high quality), 35, 70%(low quality). The change of air content of recycled aggregate concrete were similar to natural aggregate concrete. Replacement ratio of recycled aggregate was not necessarily correlated with compressive strength and modulus of rupture of recycled aggregate concrete.

  • PDF

Evaluation of the Effect of Rust Formation and the Characteristics of Sound Absorption of PSMA Concrete Mixture Using Steel Slag Aggregate (제강 슬래그 골재를 이용한 PSMA 혼합물의 녹물 발생 영향 및 흡음 특성 평가)

  • Kim, Hyeok-Jung;Jang, Dong-Bok;Kim, Han-Na
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.594-601
    • /
    • 2021
  • In order to expanding of the use of steel slag, a by-product of steel industry, as a road paving construction material, this present study confirmed the possibility of the rust formation of steel slag aggregate and evaluated the durability performance and the noise reduction characteristics of asphalt concrete mixture. As a result of conducting the rust formation test of aggregate, no rust was observed in both aggregate, so it is judged that the possibility of rust formation in the actual road water environment is very low. As a result of performing the moisture resistance test, all mixtures showed a tensile strength ratio exceeding 85%, satisfied the standard as asphalt mixture. In addition, the sound absorption coefficient of the steel slag aggregate mixture was measured to be higher than that of the general aggregate mixture. Accordingly, it is speculated th at th e steel slag aggregate mixture can more effectively respond to road noise reduction than the general mixture.

Mechanical Characteristics of Recycled PET Polymer Concrete with Demolished Concrete Aggregates (PET와 재생골재를 이용한 폴리머콘크리트의 역학적 특성)

  • Jo Byung-Wan;Lee Du-Wha;Park Seung-Kook
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.335-342
    • /
    • 2005
  • In this paper, fundamental properties of Polymer Concrete(PC), made from unsaturated polyester resin based on recycled PET and recycled aggregate were investigated. Mechanical properties include strength, modulus of elasticity, and chemical resistance. Resins based on recycled PET and recycled aggregate offer the possibility of low source cost for forming useful products, and would also help alleviate an environmental problem and save energy. The results of test for resin contents and recycled aggregate ratio we, first, the strength of Polymer Concrete made with resin based on recycled PET and recycled aggregate increases with resin contents relatively, however beyond a certain resin contents the strength does not change appreciably, Second, the relationship between the compressive strength and recycled aggregate ratio at resin $9\%$ has a close correlation linearly whereas there is no correlation between the compressive strength and the flexural strength of RPC with recycled aggregate ratio. Third, the effect of acid resistance at resin $9\%$ was found to be nearly unaffected by HCI, whereas the PC with $100\%$ recycled aggregate showed poor acid resistance. Unlike acid, alkali nearly does not seem to attack the RPC as is evident from the weight change and compressive strength. And last, In case of stress-strain curve of polymer concrete with $100\%$ of natural aggregate and $100\%$ recycled aggregate it is observed the exceptional behavior resulting in different failure mechanisms of the material under compression.

Gradation Curve of Coarse Aggregate by Digital Image Analysis (디지털 이미지 처리 기법을 이용한 굵은골재의 입도분포곡선)

  • Lee, Kwan-Ho;Kim, Young-Jin;Hwang, Tak-Jin;Cho, Jae-Yoon
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.69-78
    • /
    • 2011
  • The purpose of this research is particle shape evaluation of aggregate using Digital Image Process(DIP). DIP is very useful to measure the roughness and particle shape of aggregates. Couple of aggregates, like standard sand, two different crushed stones, and two different marine aggregates, have been employed. Shape factors of two different marine aggregates are ranged 0.35 to 0.54. Crushed stone I is 0.74 which is highly flat, but standard sand is elongated shape. Especially, two marine aggregate showed a big difference of width and length which meaned a long shape. There is any significant difference of elongation ratio and flatness for each aggregate with different measuring system, like direct measurement of vernier calipers and DIP method. Shape conversion coefficient and equivalent diameter for changing 2D image to 3D image by the Digital Image Process(DIP) have been suggested and modified particle size distribution curve has been showed. The measured flatness ratios of each aggregate were 0.30, 0.36, 0.47 and 0.83, respectively. Also, the conversion shape coefficients of each aggregate were determinded as 0.77, 0.78, 0.84 and 0.92. The size of aggregate has been modified by multiplying the shape conversion coefficient and the aggregate size from DIP. The modified gradation curve with modified volume and weight of aggregate has been suggested. Within the limited test results, DIP is one of useful to get the particle shape of aggregate with limitation of measuring errors and to apply the particle distribution curve.

Strength of Recycled Concrete with Furnace Slag Cement under Steam Curing Condition (순환골재 및 고로슬래그 시멘트를 사용한 증기양생 콘크리트의 강도 특성)

  • Lee Myung-Kue;Kim Kwang-Seo;Lee Keun-Ho;Jung Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.613-620
    • /
    • 2005
  • There are some problems in utilizing recycled concrete aggregate go structural use because of the difficulties concerning about quality control and durability. It seems to be possible to utilize recycled concrete aggregate for making concrete products because quality control of concrete products is easier than ready-mixed concrete, but there are little studies about the properties of the steam-cured recycled aggregate concrete. In this study, various tests were performed such as compressive strength, flexural strength, splitting tensile strength, bonding strength and chloride ion penetration test to evaluate the effect of substitution of recycled concrete aggregate. The results of strength test showed that the concrete strength decreased with the increase of the substitution ratio of recycled concrete aggregate, but it was in the reasonable range and almost equal to that of normal concrete below the substitution ratio of $50\%$. On the other hand, strength test of furnace slag cement concrete shows that the strength of recycled concrete with furnace slag cement under curing condition lower than that of recycled concrete with ordinary portland cement under same condition. From the result of this study, it can be concluded that recycled concrete aggregate is able to be utilized for structural use but substitution ratio should be decided with care in each case. The result of this study could be used as the basic data for the structural use of recycled concrete aggregate.

Investigation on the Mechanical Properties of High-Strength Recycled Fine Aggregate Mortar Made of Nanosilica Dispersed by Sonication (나노실리카 혼입률이 실리카퓸 및 고로슬래그 미분말을 혼입한 4성분계 고강도 순환잔골재 모르타르의 역학적 성능에 미치는 영향)

  • Seong-Woo Kim;Rae-Gyo Moon;Eun-Bi Cho;Chul-Woo Chung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.2
    • /
    • pp.97-104
    • /
    • 2023
  • In order to maximize the utilization of recycled fine aggregate, high strength mortar made of 100 % recycled fine aggregate was prepared, and its physical properties were evaluated to determine the possibility of using recycled fine aggregate as structural aggregate. The effect caused by the amount of nanosilica on the physical properties of w/b 0.2 recycled fine aggregate mortar consisting of cement, silica fume, and blast furnace slag. To improve the dispersion of nanosilica inside mortar, an aqueously dispersed nanosilica solution by ultrasonic tip sonication was prepared, and incorporated into the mortar to evaluate changes in mortar flow, porosity and compressive strength depending on nanosilica content. According to the experimental results, mortar flow decreased as the replacement ratio of nano-silica increased. As the replacement ratio of nanosilica increased up to 0.75 %, the porosity decreased and the compressive strength increased, but, at a replacement ratio of 1 %, the porosity increased and the compressive strength decreased. It was confirmed that the nano-silica replacement ratio of 0.75 % was optimum proportion to maximize the mechanical performance of high-strength recycled fine aggregate mortar.

Spalling Characteristics of High Performance Concrete According to Changes in PP Fiber Ratio and Type of Aggregate (PP섬유 혼입율 및 잔골재 종류 변화에 따른 고성능 콘크리트의 폭렬특성)

  • Jung, Hong-Keun;Kim, Won-Ki;Pei, Chang-Chun;Han, Min-Cheol;Yang, Seng-Hwan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.61-64
    • /
    • 2009
  • This study is reviewed fire resistance characteristics of high strength concrete according to changes in PP fiber mixing ratio and type of fine aggregate, and the results can be summarized as follows. As fire resistance characteristics, all plain crushed sands prevented spalling regardless of increase in mixing ratio of PP fiber. Mixtures other than the plain showed satisfactory spalling prevention when 0.05 % or more of PP fiber was mixed. After the fire resistance experiment, the plain showed 5.5 % of mass loss rate when fiber was not mixed and others could not be measured. According to increase in mixing ratio of fiber, river sand with fineness modulus of 2.2 showed most satisfactory result of 34 %${\sim}$42 %. Mass loss rate after fire resistance experiment was most satisfactory at about 10 % in the plain crushed sand without mixing of fiber, and all other mixes with 0.05 % PP fiber or more showed 5${\sim}$10 % loss rate.

  • PDF

A Comparative Study on the Quality of Recycled Aggregate for Concrete by Crushing Method (파쇄 방법에 따른 콘크리트용 순환골재의 품질 비교 연구)

  • Choi, Won-Young;Lee, Sae-Hyun;Kim, Seoung-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.121-129
    • /
    • 2017
  • In this study, the quality of recycled aggregate for concrete was investigated as the number of recycled aggregate crushing cycles, grinder and crusher, peeling and crushing. First, the quality of density, absorption ratio and solid content was improved as the separation distance decreased and the number of crushing increased, depending on the number of crushing of recycled aggregate and the distance between mantle and cone cave. The quality of density, absorption ratio and solid content was improved as the wire mesh used in striking plate and the number of hammers increased, depending on the type of striking plate and the number of hammers.

Porous concrete with optimum fine aggregate and fibre for improved strength

  • Karanth, Savithri S.;Kumar, U. Lohith;Danigond, Naveen
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.305-309
    • /
    • 2019
  • Pervious concrete pavements are the need of the day to avoid urban flooding and to facilitate ground water recharge. However, the strength of pervious or porous concrete is considerably less compared to conventional concrete. In this experimental investigation, an effort is made to improve the strength of pervious concrete by adopting fibres and a small amount of fine aggregate. A porous concrete with cement to aggregate ratio of 1:5 and a water-powder ratio of 0.4 is adopted. 30% of the cement is replaced by cementitious material ground granulated blast furnace slag (GGBS) for better strength and workability. Recron fibres at a dosage of 0.5, 1.0 and 1.5% by weight of cement were included to improve the impact strength. Since concrete pavements are subjected to impact loads, the impact strength was also calculated by "Drop ball method" in addition to compressive strength. The effect of fine aggregate and recron fibres on workability, porosity, compressive and impact strength was studied. The investigations have shown that 20% inclusion of fine aggregate and 1.5% recron fibres by weight of cement give better strength with an acceptable range of porosity.

Application of Waste Foundry Sand for Concrete-Based Products of Low Water Ratio (낮은 물비를 갖수용성 합성 절삭유의 재사용을 위한 한외여과 연구는 콘크리트 제품에 대한 폐주물사의 적용)

  • Kim, Jin-Man;Cho, Sung-Hyun;Kwak, Eun-Goo
    • Clean Technology
    • /
    • v.8 no.3
    • /
    • pp.129-139
    • /
    • 2002
  • This is the study for recycling waste foundry sand. Authors studied about main subject of grading of aggregate and three experimental items such as physical properties of waste foundry sand, optimum grading for concrete products of low water ratio, and quality variations of concrete products according to substitution proportion of fine aggregate as waste foundry sand. We were convinced of following results by experimental study. The first was that waste foundry sand was not fit as the aggregate for concrete because of bad qualities such as grading, unit weight, solid volume and passing 0.08 mm seive, so it is proper to composition using with other fine aggregetes. The second was that optimum grading is fineness modulus of 2.77 to 3.28 And the last is that optimum condition about substitution proportion as waste foundry sand is 10% fine aggregate.

  • PDF