• Title/Summary/Keyword: Ag+ solution

Search Result 661, Processing Time 0.027 seconds

The Effect of Heat-treatment on Brazing Characteristics of WC-9%Co/SUJ2 Steel (WC-9%Co와 SUJ2강의 접합특성에 미치는 열처리의 영향)

  • 정하윤;김종철;박경채
    • Journal of Welding and Joining
    • /
    • v.15 no.5
    • /
    • pp.56-63
    • /
    • 1997
  • In The study, the bonding of WC-9%Co to SUJ2 steel using Ag-Cu-Zn-Cd insert metal has performed to investigate the bonding properties by heat-treatment. Bonding was brazed for 5-30min at 95$0^{\circ}C$, performed solution treatment for 5 min at 85$0^{\circ}C$ and sustained subsequently oil quenching. To investigate the effect of heat-treatment, tempering was executed at $600^{\circ}C$ for 30 min after oil quenching. Mechnical properties and chemical compositions on the brazed bonding interface were investigated by means of microstructural observation, 4-point bending test and EDS and XRD measurements. The results obtained were as follows. 1) The bonding strength of WC-9%Co/SUJ2 joints by Ag-Cu-Zn-Cd insert metal obtained about 78, 117 and 72MPa after brazing for 5, 20 and 30 min at 95$0^{\circ}C$. And the highest bonding strength obtained about 131MPa after brazing for10 min at 95$0^{\circ}C$ 2) Higher bonding strength of 288MPa was obtained in the joint that brazed for 10 min at 95$0^{\circ}C$, and carried out tempering for 30 min at $600^{\circ}C$ subsequently. 3) Fracture of joint brazed by Ag-Cu-Zn-Cd insert metal for 5, 10, 20 and 30 min created WC-9%Co/SUJ2 interface. The joint that brazed for 10 min at 95$0^{\circ}C$ and then tempered for 30 min at $600^{\circ}C$ was fractured at the site of WC-9%Co.

  • PDF

Electrochemical Reduction Behavior of Bilirubin (Bilirubin의 전기화학적 환원거동)

  • Bae Zun Ung;Lee Heung Lark;Jung Mi Sik;Park Tae Myung
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.374-378
    • /
    • 1991
  • The electrochemical reduction behavior of Bilirubin (BR) in phosphate buffer (pH 7.8) solution was studied by DC polarography, differential pulse polarography, cyclic voltammetry and controlled potential coulometry. In DC polarogram, two reduction waves of BR were found. The half wave potentials of two reduction waves were -1.32 and -1.51 volts vs. Ag/AaCl respectively. The current type of 1st reduction wave was diffusion-controlled and the 2$^{nd}$ reduction wave was diffusion current containing a little kinetic current. The electrochemical reduction process of BR at each reduction step was all irreversible. The prewave appeared at lower concentration than 3.4 ${\times}$ 10$^{-4}$M, this prewave was identified as adsorption prewave. And the number of electron transfered in reduction steps, n$_{app}$ was two for the 1st reduction step and one for the 2$^{nd}$ reduction step.

  • PDF

The effect of repeated porcelain firings on corrosion resistance of different dental alloys

  • Tuncdemir, Ali Riza;Karahan, Ismail;Polat, Serdar;Malkoc, Meral Arslan;Dalkiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.44-50
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effects of repeated porcelain firing process on the corrosion rates of the dental alloys. MATERIALS AND METHODS. Cr-Co, Cr-Ni and Pd-Ag alloys were used for this study. Each metal supported porcelain consisted of 30 specimens of 10 for 7, 9 and 11 firing each. Disc-shaped specimens 10 mm diameter and 3 mm thickness were formed by melting alloys with a propane-oxygen flame and casted with a centrifuge casting machine and then with the porcelain veneer fired onto the metal alloys. Corrosion tests were performed in quintuplicate for each alloy (after repeated porcelain firing) in Fusayama artificial saliva solution (pH = 5) in a low thermal-expansion borosilicate glass cell. Tamhane and Sheffe test was used to compare corrosion differences in the results after repeated firings and among 7, 9 and 11 firing for each alloy. The probability level for statistical significance was set at ${\alpha}$=0.05. RESULTS. The corrosion resistance was higher (30 mV), in case of 7 times firing (Commercial). On the other hand, it was lower in case of 11 times firing (5 mV) (P<.05). Conclusion. Repeated firings decreased corrosion resistance of Pd-Ag, Cr-Co and Cr-Ni alloys. The Pd-Ag alloy exhibited little corrosion in in vitro tests. The Cr-Ni alloy exhibited higher corrosion resistance than Cr-Co alloys in in vitro tests.

The Relationship of Leptin (+19) AG, Leptin (2548) GA, and Leptin Receptor Gln223Arg Gene Polymorphisms with Obesity and Metabolic Syndrome in Obese Children and Adolescents

  • Bilge, Serap;Yilmaz, Resul;Karaslan, Erhan;Ozer, Samet;Ates, Omer;Ensari, Emel;Demir, Osman
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.3
    • /
    • pp.306-315
    • /
    • 2021
  • Purpose: Obesity is defined as the abnormal or excessive accumulation of fat over acceptable limits. Leptin is a metabolic hormone present in the circulation in amounts proportional to fat mass. Leptin reduces food intake and increases energy expenditure, thus regulating body weight and homeostasis. Various polymorphisms are present in the leptin gene and its receptor. These polymorphisms may be associated with obesity. This study aimed to show the association of leptin (+19) AG, leptin (2548) GA, and Gln223Arg leptin receptor polymorphisms with obesity and metabolic syndrome in Turkish children aged 6-17 years, and to conduct further investigations regarding the genetic etiology of obesity. Methods: A total of 174 patients diagnosed with obesity and 150 healthy children who were treated at Tokat Gaziosmanpasa Medical School Hospital between September 2014 and March 2015 were included in this study. The ages of the children were between 6 and 17 years, and anthropometric and laboratory results were recorded. Genotyping of leptin (+19) AG, leptin (2548) GA, and leptin receptor Gln223Arg polymorphisms was performed by polymerase chain reaction. Results: An association between leptin receptor Gln223Arg gene polymorphism and obesity was detected. Conclusion: Further studies are needed to determine the role of genetic etiologies and to indicate the role of leptin signal transmission impairment in the pathogenesis of obesity. We hope that gene therapy can soon provide a solution for obesity.

ON THE EXISTENCE OF POSITIVE SOLUTION FOR A CLASS OF NONLINEAR ELLIPTIC SYSTEM WITH MULTIPLE PARAMETERS AND SINGULAR WEIGHTS

  • Rasouli, S.H.
    • Communications of the Korean Mathematical Society
    • /
    • v.27 no.3
    • /
    • pp.557-564
    • /
    • 2012
  • This study concerns the existence of positive solution for the following nonlinear system $$\{-div(|x|^{-ap}|{\nabla}u|^{p-2}{\nabla}u)=|x|^{-(a+1)p+c_1}({\alpha}_1f(v)+{\beta}_1h(u)),x{\in}{\Omega},\\-div(|x|^{-bq}|{\nabla}v|q^{-2}{\nabla}v)=|x|^{-(b+1)q+c_2}({\alpha}_2g(u)+{\beta}_2k(v)),x{\in}{\Omega},\\u=v=0,x{\in}{\partial}{\Omega}$$, where ${\Omega}$ is a bounded smooth domain of $\mathbb{R}^N$ with $0{\in}{\Omega}$, 1 < $p,q$ < N, $0{{\leq}}a<\frac{N-p}{p}$, $0{{\leq}}b<\frac{N-q}{q}$ and $c_1$, $c_2$, ${\alpha}_1$, ${\alpha}_2$, ${\beta}_1$, ${\beta}_2$ are positive parameters. Here $f,g,h,k$ : $[0,{\infty}){\rightarrow}[0,{\infty})$ are nondecresing continuous functions and $$\lim_{s{\rightarrow}{\infty}}\frac{f(Ag(s)^{\frac{1}{q-1}})}{s^{p-1}}=0$$ for every A > 0. We discuss the existence of positive solution when $f,g,h$ and $k$ satisfy certain additional conditions. We use the method of sub-super solutions to establish our results.

The Hydrogenation Behaviors of V-xAl (x=1, 5wt.%) Composites by Mechanical Alloying (기계적 합금화법으로 제조한 V-xAl (x=1, 5wt.%) 복합재료의 수소화 반응 거동)

  • Kim, Kyeong-Il;Hong, Tae-Whan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.458-464
    • /
    • 2011
  • Recently, one of the hydrogen production methods has attracted using dense metallic membrane. It has high hydrogen permeation and selectivity which hardly could adopt industrial product because of high cost, hydrogen embrittlment and thermal stability. Meanwhile, vanadium has high hydrogen solubility and it use to instead of Pd-Ag amorphous membrane. Aluminum carried out blocking hydrogen diffusion on grain boundary therefore protecting hydrogen embrittlement. Most of dense metallic membrane is solution diffusion mechanism. The solution diffusion mechanism was very similar hydrogen storing steps such as steps of metal hydride. Thus, V-Al composites were fabricated to use hydrogen induced mechanical alloying. The fabricated V-Al composites were characterized by XRD, SEM, EDS and simultaneous TG/DSC analyses. The hydrogenation behaviors were evaluated using a Sievert's type automatic PCT apparatus. The hydrogenation behaviors of V-Al composites was evaluated too low hydrogen stored capacity and fast hydrogenation kinetics. In PCI results, V-Al composites had low hydrogen solubility, in spite of that, hydrogen kinetics was calculated very fast and hydrogen absorption/desorption contents were same capacity.

Antimicrobial Activity of Fabrics Treated with Colloidal Silver Solutions Made by Electrolysis and Reduction (제조 방법이 다른 은 콜로이드 용액 처리 직물의 항균효과)

  • Chung Haewon;Kim Boyeon;Yang Heeju
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.6
    • /
    • pp.805-813
    • /
    • 2005
  • In recent years, greatly increased incidences of diseases made people more concerned about their hygienic environment. Since clothes are the closest environment to man, many methods have beef proposed to impart antimicrobial properties to the textiles. Benefits associated with incorporating antimicrobial properties in textiles include protection to the wearer from microbiological attack, and prevention of odor from perspiration. Silver has been known to kill 650 different disease organisms, however, nano-sized silver particles are known as skin friendly and does not cause skin irritation. In this study, we have examined the antimicrobial effects of cotton or polyester fabric, on which nano-sized silver particles were treated. Colloidal silver solution made by electrolysis of $99.9\%$ silver stick was more effective than that by reduction of $AgNO_3.\;0.7\%$ concentration of colloidal silver solution by electrolysis is helpful to give reduction of $99.9\%$ S. aureus and K. pneumoniae on a cotton fabric without the decrease of whiteness. Since the structures of fiber and fabric effect on their antimicrobial property, PET filament fabric didn't have sufficient antimicrobial properly. The fabrics treated with up to $5\%$ colloidal silver solution didn't have the properly of antistatic and electromagnetic shield.

The Prevention of Carryover in the Automated System With Fixed Tips (자동 분주기 Fixed Tip의 Carryover 방지를 위한 개선 방안)

  • Hwang, Bo-Ra;Au, Doo-Hee;Bae, Jin-Su;Park, Jong-O;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.181-184
    • /
    • 2009
  • Purpose: Automated system that immunoassay examination are used widely. However, sample to sample carryover can cause that the next patient sample is false positive. Materials and Methods: We test HBs Ag, HBs Ab, HBc Ab(IgG) with Automated pipetting system (Tecan). It was placed with very high concentrations followed by saline solution. During this experiment, The fixed tip of Automated system wash With 0.25 moL/L NaOH. The Measurement results of saline solution confirm the occurrence of carryover. Results: Results of saline solution with 0.25 moL/L NaOH cleaning process was measured 100% negative, And results of patient serum with 0.25 moL/L NaOH cleaning process is similar reported results. Conclusion: As Results, 0.25 moL/L NaOH cleaning process was avoid carryover in experiment, And we know results of the hepatitis test did not affected by this solution we recommend 0.25 moL/L NaOH cleaning process as the Prevention of carryover in the automated system with fixed Tips.

  • PDF

ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF DENTAL AMALGAM IN ARTIFICIAL SALIVA (인공타액에서 아말감의 부식거동에 관한 전기화학적 연구)

  • Kim, Yeoung-Nam;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.221-235
    • /
    • 1988
  • The purpose of this study was to observe characteristic properties through the polarization curves and EMPA images from 4 different types of amalgam obtained by using the potentiostats (EG & G PARC) & EPMA (Jeol JSM-35), to investigate the degree of corrosion of each phase of amalgam on the oxidation peak, and to identify corrosion products from the corroded amalgam by use of X-ray diffractometer(Rigaku). After each amlgam alloy and Hg were triturated as the direction of the manufacturer by means of the mechanical amalgamator(Shofu), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10mm in height and was condensed by means of routine manner. The specimen was removed from the mold and stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution(pH6.8~7.0) and artificial saliva (pH6.8~7.0) at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen in electrolyte and the potential scan was begun at the potential of 100mV cathodic from the corrosion potential. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.64$cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). EPMA images on the determined oxidation peaks of each amalgam in artificial saliva were observed. X-ray diffraction patterns of each sample were recorded before and after polarization in artificial saliva (Aristaloy, Caulk Spherical, Dispersalloy and Tytin: at +770mV, +585mV, +8.10m V and +680m V respectively) by use of a recording diffractometer. Nickel filtered Cu $K_{{\alpha}_1}$ radiation was used and sample was scanned at $4^{\circ}(2{\theta})/min.$ from $25^{\circ}$ to $80^{\circ}$. The following results were obtained. 1. Oxidation peak potential in artificial saliva shifted to more anodic direction than that in saline solution. 2. The corrosion potential of high copper amalgam was more anodic than the potential of low copper amalgam. 3. The current density was lower in artificial saliva than in saline solution. 4. One of the corrosion products, AgCl was identified by X-ray diffraction analysis. 5. ${\gamma}_2$ phase was the most susceptible to corrosion and e phase was stable in low copper amalgam and ${\eta}$' phase and Ag-Cu eutectic were susceptible to corrosion in high copper amalgam.

  • PDF

Separation and Concentration of Trace Mercury [Hg(II)] in Water Sample by Coprecipitation Flotation Technique (공침-부선기술에 의한 수용액 시료 중 흔적량 수은 [Hg(II)]의 분리 및 농축)

  • Lee Kang-Seok;Choi Hee-Seon;Kim Seon-Tae;Kim Young-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.355-361
    • /
    • 1991
  • The separative preconcentration of trace mercury[Hg(II)] in a water sample was studied by a coprecipitation flotation technique. The trace Hg(II) was precipitated together with Ce(OH)$_3$ by adding 3.0 ml of 0.1M Ce$^{3+}$ solution to 1,000 ml of water sample and adjusting pH to 11.0 with 1.0M NaOH solution. The hydrophobic precipitate[Ce(OH)$_3$-Hg(OH)$_2$], which was formed by adding 2.0 ml of 0.1${\%}$ ethanolic sodium oleate solution, were floated on the surface with an aid of tiny nitrogen gas bubbles. The floated materials were quatitatively collected in a suction flask and dissolved with 5.0 ml of 2.0M HNO$_3$. The solution was marked to 25.00 ml with a deionized water. The content of Hg(II) was determined by cold vapor atomic absorption spectrophotometry. Any interferences of concomitants such as Ag$^+$, Br$^-$, I$^- $, etc. were not observed on the whole procedure. The analytical result showed that Hg(II) found in the wastewater of Seochang Campus, Korea University was 1.98 ng/ml with the relative standard deviation of 3.6${\%}$. And recoveries of Hg(II) in the wastewater into which 1.0 ng/ml and 2.0 ng/ml were added were 95${\%}$ and 91${\%}$, respectively. From such results, this procedure could be concluded to be tolerably accurate and reproducible for the determination of trace mercury in a water sample.

  • PDF