• 제목/요약/키워드: Afterload

검색결과 27건 처리시간 0.025초

모터구동형 완전이식 인공심장에서 전류파형의 분석에 의한 심박출량 자동제어 알고리즘의 개발 (A Study On the Automatic Cardiac Output Control Without Pressure Sensors for the motor-driven Totally Implantable TAH Using Motor-Current Waveform Analysis)

  • 최원우;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.130-135
    • /
    • 1992
  • In this paper a new cardiac output control method without pressure sensors is presented for the rotor-driven totally implantable TAH using motor-current wavelet analysis. Theoretical analysis and mock circulation system experiment results show that cardiac output of TAH, which is indeperdent of afterload and sensitively dependent to preload, is well controlled for the independently variable preload.

  • PDF

보행 혈압 측정과 심장 기능의 관계 (Relationship between ambulatory blood pressure monitoring and cardiac function)

  • 송영환
    • Clinical and Experimental Pediatrics
    • /
    • 제52권7호
    • /
    • pp.752-755
    • /
    • 2009
  • It is well known that hemodynamic load is one of the most important determinants of cardiac structure and function. Circadian variations in blood pressure (BP) are usually accompanied by consensual changes in peripheral resistance and/or cardiac output. In recent years, reduction in circadian variations in BP and, in particular, loss of nocturnal decline of BP were observed in hypertensive patients with left ventricular hypertrophy (LVH). The patients with only a slight or no loss of nocturnal decline of BP were considered "non-dippers". Regression of LVH was observed after prolonged antihypertensive therapy. Restoration of the circadian rhythm of BP was also observed. However, the classification of patients into "dippers" and "non-dippers" is arbitrary and poorly standardized and repeatable, and in the recent studies, most hypertensive patients with LVH were "dippers". Therefore, we should be particularly cautious about the conclusions drawn using this index. On the other hand, reduced activity of low-pressure cardiopulmonary baroreceptors and impaired day-to-night modulation of autonomic nervous system activity were observed in patients with only LVH. Therefore, alterations in cardiac structure may impair BP modulation. On the other hand, the reverse can also be trueprimary alterations in BP modulation, through a persistently elevated afterload, can increase cardiac mass. Thus, the interrelationship between cardiac structure and BP modulation is complex. Hence, new and more specific methods of evaluating circadian changes in BP are needed to better clarify the abovementioned reciprocal influences.

Development of the Control System for the Motor-Driven Electromechanical Total Artificial Hearta

  • Kim, Hee-Chan;Lee, Sang-Hun;Kim, Jong-Won-;Kim, Jin-Tae-;Min, Byoung-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.858-863
    • /
    • 1988
  • A micro-processor based control system for a brushless DC motor used in the motor-driven electromechanical total artificial heart was developed. Functionally, the control system is composed of two parts. The first part is the velocity and position controller to assure that the motor follows a predetermined optimal velocity profile with minimal energy consumption, and to guarantee the full stroke length. This part also utilize the passive adaptive control method to be robust against the load disturbance, system parameter variation, and uncertainty which is the environment of artificial heart system. The pump output control is the second part, and this part provides the required responses of the artificial heart to the time-varying physiologic demands. The basic requirements of these responses are preload sensitivity, afterload insensitivity, and the balanced ventricular outputs. The performance and reliability of this control system was evaluated through a series of mock circulation tests and animal implantation, and the results are very encouraging.

  • PDF

역동적 삼차원 재구성기로 측정한 In Vivo 상태의 좌심실의 Emax 와 박출계수 (In Vivo Estimation of Emax and Ejection Fraction Using Dynamic Spatial Reconstructor)

  • 김광호
    • Journal of Chest Surgery
    • /
    • 제21권2호
    • /
    • pp.223-230
    • /
    • 1988
  • Emax, end-systolic pressure-volume relationship, has been established as a new concept which can be representative of ventricular contractility itself since 1970s. Comparing to ejection fraction[EF], Emax is independent of preload and afterload. However Emax has not been proved precisely in non-thoracotomized condition because current methods have limitation in measuring ventricular chamber volume accurately in in viva state. The Dynamic Spatial Reconstructor[DSR], high speed computerized tomography, can measure ventricular chamber volume accurately throughout cardiac cycle in non-thoracotomized state. So Emax and EF of the left ventricle was tried to measure precisely in in vivo condition with DSR. Emax was compared to EF to estimate its ability to evaluate ventricular contractility. 5 mongrel dogs, weighing 15-16kg, were used for measuring Emax and EF of the left ventricle in 3 or 4 different loading conditions using DSR. Emax value in 5 dogs was from 2.62 to 10.49. Each dog has one Emax value regardless of loading conditions. However EF in 5 dogs varies depending on loading conditions. The conclusions are that Emax is useful in in viva state and EF varies depending on loading conditions. So Emax should be tried to use in clinical situation rather than EF because it is always representative of contractility itself regardless loading conditions in in viva state.

  • PDF

적응 학습방식의 신경망을 이용한 좌심실보조장치의 모델링 (Adaptively Trained Artificial Neural Network Identification of Left Ventricular Assist Device)

  • 김상현;김훈모;류정우
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.387-394
    • /
    • 1996
  • This paper presents a Neural Network Identification(NNI) method for modeling of highly complicated nonlinear and time varing human system with a pneumatically driven mock circulatory system of Left Ventricular Assist Device(LVAD). This system consists of electronic circuits and pneumatic driving circuits. The initiation of systole and the pumping duration can be determined by the computer program. The line pressure from a pressure transducer inserted in the pneumatic line was recorded System modeling is completed using the adaptively trained backpropagation learning algorithms with input variables, heart rate(HR), systole-diastole rate(SDR), which can vary state of system. Output parameters are preload, afterload which indicate the systemic dynamic characteristics. Consequently, the neural network shows good approximation of nonlinearity, and characteristics of left Ventricular Assist Device. Our results show that the neural network leads to a significant improvement in the modeling of highly nonlinear Left Ventricular Assist Device.

  • PDF

Energetics of the Heart Model with the Ventricu1ar Assist Device

  • Chung, Chanil-Chung;Lee, Sang-Woo;Han, Dong-Chul;Min, Byoung-Goo
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.43-48
    • /
    • 1996
  • We investigated the energistics of the physiological heart model by comparing predictive indexes of the myocardial oxygen consumption (MOC), such as tension-time index (R), tension-time or force-time inteual (FTI), rate-pressure product (RPP), pressure-work index, and systolic pressure-volume area (PVA) when using the electro-hydraulic left ventricular device (LVAD). We developed the model of LVAD incorporated the closed-loop cardiovascular system with a baroreceptor which can control heart rate and time-varying elastance of left and right ventricles. On considering the benefit of the LVAD, the effects of various operation modes, especially timing of assistance, were evaluated using this coupled computer model. Overall results of the computer simulation shows that our LVAD can unload the ischemic (less contractile) heart by decreasing the MU and increasing coronary flow. Because the pump ejection at the end diastolic phase of the natural heart may increase the afterload of the left ventricle, the control scheme of our LVAD must prohibit ejecting at this time. Since the increment of coronary flow is proportional to the peak aortic pressure after ventricle contraction, the LVAD must eject immediately following the closure of the aortic valve to increase oxygen availability.

  • PDF

인삼이 심장 수축력과 소포체 기능에 미치는 영향(제1보) -흰쥐 심장의 수축력 및 유두근의 Force-Velocity 곡선에 대한 인삼성분의 효과- (The Effect of Ginseng on Heart Contraction and Sarcoplasmic Reticulum Function(I) -The Effect of Ginseng on the Myocardial Contractility and Force-Velocity Curves of Papillary Muscles from Rats)

  • 오우택;김낙두
    • 약학회지
    • /
    • 제27권2호
    • /
    • pp.155-161
    • /
    • 1983
  • The rates of deterioration of contractile forces of isolated hearts from ginseng component treated rats were determined. Rat papillary muscles were also used to study the influence of ginseng on the mechanical performance of heart. Rats weighing 200-300g were administered orally with ginseng ethanol extract (100mg/kg/day), ginseng total saponin (50mg/kg/day) and ginsenoside Rbl (5mg/kg/ day) for a week respectively. The isolated hearts from rats were perfused with Krebs-Henseleit solution by Langendorff perfusion apparatus. The force-velocity relation was clearly seen with the load-generator equipped isotonic shortening recording apparatus. The control group was only able to maintain 60% of their initial contractile forces after 120 minutes of perfusion, whereas ginseng ethanol extract treated group was able to sustain nearly their initial strength even after 120 minutes of perfusion. The similar effects were seen in the hearts treated with total ginseng saponin and ginsenoside Rb$_{1}$. Ginseng ethanol extract did alter mechanical performance of rat ventricular myocardium. It increased both maximum velocity(Vmax) of isotonic shortening and isometric force (P$_{0}$) and showed increased velocity of shortening significantly (P<0,05) at any one afterload.d.

  • PDF

Effect of Korea Red Ginseng on the Symptoms and Hemodynamics in Healthy Elders

  • Jin En-Yuan;Li Ya-Jun;Yang Lian-Xing;Jin Ming;Wei Yu-Lin;Nam Ki Yeul
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 2002년도 학술대회지
    • /
    • pp.27-34
    • /
    • 2002
  • Clinical study on hemodynamics of healthy elders before and after tread mill. Using doubleblind, placebo-controlled study design. Seventy-five 50-70 years old volunteers without organic disease were divided into two groups, Ginseng group and control group. Each subject was received 3 g Korea Red Ginseng (KRG) capsules or placebo per day for 4 weeks. Before and after administration 4 weeks, the symptoms were asked and hemodynamics parameter such as pump function, systolic function, preload and afterload were recorded before and after tread mill 1,5, 10 minutes by the method of thoracic impedance cardiograph. The result showed that Ginseng could improve quality of life, had obvious effect of increasing PEP (pre-ejection period), PEP/LVET (pre-ejection period/left ventricular ejection period), PCWP (wedged pressure pulmonary capillary). The change rate of HR (heart rate), SV (stroke volume) in KRG group were much lowered, while EF (ejection fraction), LVET (left ventricular ejection period), LVEDP (left ventricular end diastolic pressure) was recovered much quickly. The circulation showed Ginseng could improve the quality of life though its promoting circulation function which are increasing both the systolic function and the preload.

  • PDF

Cardiac Response to Head-Out Water Immersion in Man

  • Choi, Jang-Kyu;Park, Won-Kun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제4권3호
    • /
    • pp.253-261
    • /
    • 2000
  • Head-out water immersion induces marked increase in the cardiac stroke volume. The present study was undertaken to characterize the stroke volume change by analyzing the aortic blood flow and left ventricular systolic time intervals. Ten men rested on a siting position in the air and in the water at $34.5^{circ}C$ for 30 min each. Their stroke volume, heart rate, ventricular systolic time intervals, and aortic blood flow indices were assessed by impedance cardiography. During immersion, the stroke volume increased 56%, with a slight (4%) decrease in heart rate, thus cardiac output increased ${\sim}50%.$ The slight increase in R-R interval was due to an equivalent increase in the systolic and diastolic time intervals. The ventricular ejection time was 20% increased, and this was mainly due to a decrease in pre-ejection period (28%). The mean arterial pressure increased 5 mmHg, indicating that the cardiac afterload was slightly elevated by immersion. The left ventricular end-diastolic volume index increased 24%, indicating that the cardiac preload was markedly elevated during immersion. The mean velocity and the indices of peak velocity and peak acceleration of aortic blood flow were all increased by ${\sim}30%,$ indicating that the left ventricular contractile force was enhanced by immersion. These results suggest that the increase in stroke volume during immersion is characterized by an increase in ventricular ejection time and aortic blood flow velocity, which may be primarily attributed to the increased cardiac preload and the muscle length-dependent increase in myocardial contractile force.

  • PDF

말티즈 견에서 발생한 우심실양분증 (Double-chambered Right Ventricle with Intact Ventricular Septum in a Maltese Dog)

  • 강종일;이승곤
    • 한국임상수의학회지
    • /
    • 제31권5호
    • /
    • pp.403-406
    • /
    • 2014
  • 임상증상이 없는 6년령의 3.1 kg 말티즈견이 심잡음의 원인에 대한 추가 검진을 위해서 내원하였다. 흉부 방사선에서는 우심비대가 확인되었다. 심장 초음파에서는 두드러진 우심실비대, 비정상적 근육 다발과 섬유성 결절이 우심실 유출로 아래 누두부에서 발견되었다. 이러한 소견은 우심실양분증의 전형적인 형태학적 소견이다. 비정상 근육다발에서 주폐동맥으로 향하는 와류의 속도는 4.6 m/sec, 삼첨판 역류는 4.4 m/sec, 주폐동맥 혈류는 1.1 m/sec로 각각 측정되었다. 본 환자는 비록 임상증상은 없지만 협착에 의한 과도한 후부하와 그로 인한 심장의 손상을 막기 위해서 현재 atenolol (0.5 mg/kg) 을 복용하고 있다. 본 증례는 한국에서 발생한 견종에서 매우 드문 우심실양분증에 대해서 기술하였습니다.